• Title/Summary/Keyword: side

검색결과 25,120건 처리시간 0.045초

Bell's Palsy 환자의 건측-환측 안면부 피부온도차이에 관한 연구 (Differences Between Facial Skin Temperature of the Paralyzed Side and Those of the Normal Side in Bell's Palsy Patients)

  • 남동현;고형균;박영배
    • 대한한의학회지
    • /
    • 제28권1호통권69호
    • /
    • pp.126-136
    • /
    • 2007
  • Objectives : Bell's palsy in an acute peripheral facial nerve paralysis that usually affects only one side of the face. The seventh cranial nerve carries predominantly motor fibers, but also supplies some autonomic innervation, sensation to park of the ear, and taste to the anterior two thirds of the tongue. The aim of this study is to provide evidence of differences between facial skin temperature of the paralyzed side and normal side in Bell's palsy patients. Methods : the author studied 68 patients with Bell's palsy whose facial nerve function had been documented by the House-Brackmann grading system. We measured skin temperature of the forehead, zygoma, lower lip, temple and lower jaw area of the paralyzed side and those of the normal side. Results : there were significant facial skin temperature differences between the forehead area of paralyzed side and that of normal side of GrII(P<0.05) and III(P<0.05). The result also showed that the facial skin temperature difference according to the aflection period vanished when air temperature was calibrated (F=1.700, P=0.178). Conclusions : Thermography is a useful diagnostic tool in Bell's palsy if the air temperature is low enough to cool the facial skin temperature and the forehead area is evaluated as the sampling zone.

  • PDF

수입 의료용 압박스타킹의 압력 측정치 비교 (The Comparison on the Compression Measurement Value of Medical Compression Stockings)

  • 도월희;김남순
    • 한국의류학회지
    • /
    • 제37권8호
    • /
    • pp.1060-1074
    • /
    • 2013
  • This study measured and analyzed pressure at each measurement part of imported compression stockings sold in Korea to provide basic information to establish a pressure standard and grade ranking. This study used 40 medical compression stockings imported from 6 countries. Pressure measurements were taken at 11 points: front side and back side of ankle, end-point of the gastrocnemius muscle, front, inner side, back, and outer side of calf, back side of below knew girth, inner side, and outer side of mid-thigh girth, and inner side of thigh girth. AMI 3037-10 and AMI 3037-2 were used for measurements taken inside an environmental chamber at a temperature of $21^{\circ}C$ and a relative humidity (RH) of 65%. For the measurements, 11 air pack sensors were attached to a wooden model leg (Hohenstein) and three measurements were taken at each measurement point in three minutes. The average of these measurements was used for analysis. The findings of this study were as follows. As for the front side of the ankle, of the 40 products, 14 products (6 USA, 2 Swiss, 3 Italian, and 2 Taiwanese) were within the pressure range indicated on the product label; however, no German products fell within the pressure range. A total of 8 products (5 USA, 1 Swiss, 1 Italian, and 1 German) were gradient compression type; however, no Japanese or Taiwanese product were of this type. The majority of products had the highest pressure at the end-point of the gastrocnemius muscle. Only 3 products, 1 USA (Jobst Opaque 30-40mmHg), 1 Swiss (Sigvaris Cotton 34-46mmHg) and 1 Italian (Jobstocking 25-32mmHg), had measurements that met the indicated standard pressure, were a gradient compression type, and met the overall standard for compression stockings.

농촌마을 소하천변 식생복원을 위한 자생식물 선정에 관한 연구 (Research on the Utilization of the Native Plants in Restoration of Stream-Side in Rural Areas)

  • 강방훈;이상화
    • 농촌계획
    • /
    • 제12권4호
    • /
    • pp.83-88
    • /
    • 2006
  • Recently, management and restoration efforts using the plants promote the disturbed habitats such as a set-asides or field boundaries. But, side effects are coming out because of using the exotic plants in restoration process. This study was conducted to select the native plant species used for restoration through the vegetation survey and plant community analysis at small stream-side in rural villages. We surveyed at two small stream-sides in open field and high land area in 2005 as a case study. Total 126 species was found at small stream side in open field area. As the result of important value' calculation, Persicaria thunbergii 23.0%, Humulus japonicus 18.6%, Phragmites communis 4.4%, Bromus japonicus 4.2%, and Rosa multiflora 3.4% were in the order of important value. Total 92 species were found at small stream side in high land area. As the result of important value' calculation, Dactylis glomerata 16.1%, Artemisia princeps var. orientalis 11.0%, Persicaria thunbergii 10.9%, Humulus japonicus 9.3%, Phragmites japonica 5.2% and Phragmites communis 3.5% were in the order of important value. We selected some plant species to use in restoration after due consideration of problems of exotic plant and high coverage and density species, and ecological process; Persicaria thunberii, Phragmites communis, Bromus japonicus, Rosa multiflora, Equisetum arvense, Digtaria sanguinalis, Impatiens textori, and Artemisia princeps var. orientalis in open field stream-side, and Artemisia princeps var. orientalis, Persicaria thunbergii, Phragmites japonica, Phragmites communis, Artemisia selengensis, Panicum bisulcatum, Rorippa indica, and Equisetum arvense at hghland stream-side. We will verify the selected native plants and plan the utilization of the native plants in restoration at stream-side in rural village.

횡월류위어의 형상에 따른 유량자수 추정 (An Estimation of Discharge Coefficients with the Variations of Side Weir Shape)

  • 송재우;박성식;김지호
    • 한국수자원학회논문집
    • /
    • 제40권1호
    • /
    • pp.51-62
    • /
    • 2007
  • 횡월류위어의 월류량을 산정하기 위해서는 횡월류위어의 흐름특성을 분석하고 유량계수를 산정하는 것이 필요하다. 본 연구에서는 수리실험을 통하여 직사각형, 삼각형 횡월류위어에 대하여 본류의 Froude 수, 횡월류위어의 폭, 위어정각 등의 형상변화에 따른 유량계수를 산정하였다. 횡월류위어의 유량계수는 횡월류위어의 형상 및 기하학적 조건과 본류의 Froude수에 따라 변하는 것으로 나타났다. 다중 회귀분석을 통하여 직사각형과 삼각형 횡월류위어의 유량계수식을 제시하였으며, 측정된 월류량과의 비교 분석을 통해 적용성을 확인하였다.

수심을 고려한 사이드 스캔 소나 자료의 보정 및 해저면 분류를 위한 영상분할 (Depth-based Correction of Side Scan Sonal Image Data and Segmentation for Seafloor Classification)

  • 서상일;김학일;이광훈;김대철
    • 대한원격탐사학회지
    • /
    • 제13권2호
    • /
    • pp.133-150
    • /
    • 1997
  • 본 논문의 목적은 사이드 스캔 소나 자료를 이용하여 해저면의 지질을 분류하는 알고리 즘을 제안하는 것이다. 사이드 스캔 소나 시스템에서 획득된 수치 자료에 대하여 탐사선의 항해 자료를 근거로 모자이킹을 수행하고 2차원 영상 자료를 생성하여, 평활화(Smoothing)와 같은 영 상 처리기법을 적용하여 보간을 수행하였다. 그리고, 모자익 영상의 텍스쳐 특성을 이용하여 영상 분할(Segmentation)을 실시하였다. 토우-휘시(Tow-fish)의 좌우현 센서의 특성 차이로 발생하는 좌우현음압의 차이와 센서에서 먼 곳에서 온 신호일 수록 음압이 작기 때문에 음압 자료의 보정 이 필수적이다. 본 논문에서는 토우-휘시 고도별 평균을 이용한 보정치로 음압 자료를 보정하였 고, 보정된 음압 자료로 모자익한 결과와 보정하지 않은 음압 자료를 보정하였고, 보정된 음압 자 료로 모자익한 결과와 보정하지 않은 음압 자료로 모자익한 결과를 비교하여 음압 보정된 영상의 질이 향상됨을 확인하였다. 영상의 분할 방법은 그레이 레벨 동시발생 행렬(Gray Level Co-occurrence Matrix)을 이용한 텍스쳐 특성을 기초로 그레이 레벨 최대 발생 특징식을 제안하 고, 그 결과를 제시하였다.

사이드 플랭크 운동 시 지지면이 배근육 두께에 미치는 효과 (Effect of Support Surface on Abdominal Muscle Thickness during Side Plank Exercise)

  • 오상규;김창욱
    • 대한통합의학회지
    • /
    • 제9권4호
    • /
    • pp.183-190
    • /
    • 2021
  • Purpose : The purpose of this study was to investigate the effect of side planks on the muscle thickness of the core muscles, external oblique, internal oblique, and transverse abdominis, and this study was conducted to compare whether side plank exercise according to the application of various unstable support surfaces increases the thickness by activating the action of the muscles. Methods : The subjects of this study were 30 healthy adults and were randomly and equally assigned to three groups by a random number table. All subjects were divided into three groups according to the application of an unstable support surface during the side plank(Group A = stable support, Group B = one unstable support, Group C = two unstable supports). The side plank exercise was performed 30 minutes a day, 3 times a week for a total of 4 weeks. The muscle thickness of the core muscle was measured before the intervention, 2 weeks, 4 weeks, and 3 times in total. All measured data were comparatively analyzed by repeated measures ANOVA and one-way ANOVA. The statistical significance level was set to .05. Results : The results of this study were as follows : 1. All muscles showed an interaction between training period and group. 2. There was a significant difference between the groups at the 2 weeks and 4 weeks of the internal oblique and transverse abdominis muscle measurements. Conclusion : The thickness of the abdominal muscle increased during the side plank exercise according to the support surface, and the thickness of the abdominal muscle increased the most during the side plank exercise on the unstable support surface. Therefore, it is thought that the addition of an unstable support surface will provide a more effective therapeutic effect on the thickness change of the abdominal muscle during side plank exercise.

Early postoperative treatment of mastectomy scars using a fractional carbon dioxide laser: a randomized, controlled, split-scar, blinded study

  • Shin, Hyun Woo;Suk, Sangwoo;Chae, Seoung Wan;Yoon, Kun Chul;Kim, Junekyu
    • Archives of Plastic Surgery
    • /
    • 제48권4호
    • /
    • pp.347-352
    • /
    • 2021
  • Background Mastectomy leaves unsightly scarring, which can be distressing to patients. Laser therapy for scar prevention has been consistently emphasized in recent studies showing that several types of lasers, including fractional ablation lasers, are effective for reducing scar formation. Nonetheless, there are few studies evaluating the therapeutic efficacy of ablative CO2 fractional lasers (ACFLs). Methods This study had a randomized, comparative, prospective, split-scar design with blinded evaluation of mastectomy scars. Fifteen patients with mastectomy scars were treated using an ACFL. Half of each scar was randomized to "A," while the other side was allocated to group "B." Laser treatment was conducted randomly. Scars were assessed using digital photographs of the scar and Vancouver scar scale (VSS) scores. Histological assessments were also done. Results The mean VSS scores were 2.20±1.28 for the treatment side and 2.96±1.40 for the control side. There was a significant difference in the VSS score between the treatment side and the control side (P=0.002). The mean visual analog scale (VAS) scores were 4.13±1.36 for the treatment side and 4.67±1.53 for the control side. There was a significant difference in VAS score between the treatment side and the control side (P=0.02). Conclusions This study demonstrated that early scar treatment using an ACFL significantly improved the clinical results of the treatment compared to the untreated scar, and this difference was associated with patient satisfaction.

통계적 가중치를 이용한 협력형 소스측 DDoS 공격 탐지 기법 성능 평가 (Assessment of Collaborative Source-Side DDoS Attack Detection using Statistical Weight)

  • 염성웅;김경백
    • KNOM Review
    • /
    • 제23권1호
    • /
    • pp.10-17
    • /
    • 2020
  • 최근 보안이 취약한 IoT 장치를 악용하는 분산 서비스 거부 공격의 위협이 확산됨에 따라 신속하게 공격을 탐지하고 공격자의 위치를 찾기 위해 소스측 서비스 거부 공격 탐지 연구가 활성화되고 있다. 또한, 소스측 탐지의 지역적 한계를 극복하기 위해 개별 사이트에 위치한 소스측 네트워크들의 탐지 결과를 공유하는 협력형 소스측 공격 탐지 기법도 활성화되고 있다. 이 논문에서는 통계적 가중치를 이용하는 협력형 소스측 분산 서비스 거부 공격 탐지 기법의 성능을 평가한다. 통계적 가중치는 개별 소스측 네트워크의 시간대에 해당하는 탐지율과 오탐지율을 기반으로 계산된다. 제안된 기법은 여러 지역에서 발생한 소스측 서비스 거부 공격 탐지 결과들을 수집하고 가중치를 부여하여 결과를 도출하고, 이를 통해 DDoS 공격 발생 여부를 결정한다. 실제 DNS 요청 트래픽을 기반으로 실험한 결과, 제안된 기법은 높은 공격탐지율을 유지하면서, 공격오탐율을 2% 줄일 수 있음을 확인하였다.

AE-MDB 측면 충돌 시험 시 WorldSID 50%ile dummy 상해치에 대한 제어인자 연구 (The Study on control factor of WorldSID 50%ile dummy injury through AE-MDB side crash test)

  • 선홍열;한표경;김재수;김기석;윤일성
    • 자동차안전학회지
    • /
    • 제6권1호
    • /
    • pp.5-9
    • /
    • 2014
  • Over the past ten years, since the introduction of the side crash test regulation in Europe, much research work has been performed internationally to develop new and modified test procedures to improve the level of occupant protection offered by vehicles in side crash test. This research has been co-ordinated and finally contributed to development of an AE-MDB(Advanced European Moving Deformable Barrier) and WorldSID (Worldwide Side Impact Dummy). EuroNCAP(European New Car Assessment Program) has the plan to conduct AE-MDB side crash test using WorldSID from 2015 by replacing Progressive MDB and EuroSID II. Automobile manufacturers need to respond to these changes closely. This paper is to find dominant control factor and analyze it of WorldSID 50%ile dummy injury through AE-MDB side crash test by predicting best and worst condition. And control factors will be validated within EuroNCAP regulations. This paper is analyzed by DFSS(Design for six sigma) which contains 5 control factors and is evaluated by ANOVA with the data as a result of LS-DYNA analysis correlated with crash pulse from 50 kph AE-MDB side crash test using WorldSID 50%ile dummy.

Side Effects of Orthopedic Products in Veterinary Medicine in South Korea

  • Yun, Taesik;Jung, Soo Yeon;Kang, Kyongmook;Yun, Seon-Jong;Koo, Yoonhoi;Park, Jooyoung;Kim, Ill-Hwa;Kang, Hyun-Gu
    • 한국임상수의학회지
    • /
    • 제39권1호
    • /
    • pp.9-15
    • /
    • 2022
  • As more veterinary clinics become specialized with the growth of the companion animal market, an increasing number of veterinary clinics perform orthopedic surgery and use orthopedic products, some of which are defective and have side effects. Thus, the present study aimed to prepare fundamental data for the revision and development of manufacturing standards for these products in order to prevent their side effects. We conducted a survey targeting veterinary clinics as consumers and medical device companies as suppliers. Veterinary clinics were surveyed via offline and online methods; 320 clinics that offered orthopedic surgery and approximately 4,000 veterinary clinics that were registered in the Korean Veterinary Medical Association were targeted, and 153 veterinary clinics responded to the survey. The survey for medical device companies, was performed online, targeting 29 companies; 14 companies responded. The number of side effects of orthopedic products was higher in animal orthopedic products than in those for human use. Many consumers tended to suspect that side effects were caused by product defects. To resolve side effects after using orthopedic products, consumers mostly underwent reoperation. Meanwhile, some severe cases proceeded to legal disputes. Similarly, medical device companies, or the suppliers, responded that most side effects occurred in veterinary orthopedic products and that product defects and mistakes in use were the causes. As for most of the follow-up actions for side effects, these companies either reported the issue to those in charge or analyzed and resolved the issues themselves. Therefore, to develop quality products, suppliers should be provided with clear standards for the production, and information disclosure and a report system for side effects should be particularly established to gain consumers' trust regarding the safety of these products.