• Title/Summary/Keyword: shunt resistance

Search Result 112, Processing Time 0.023 seconds

Characteristics of 15 kVA Superconducting Fault Current Limiters Using Thin Films (15 kVA급 박막형 초전도 전류제한기의 한류특성)

  • 최효상;현옥배;김혜림;황시돌
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.12
    • /
    • pp.1058-1062
    • /
    • 2000
  • We investigated resistive superconducting fault current limites (SFCLs) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 A$\_$peak/, was produced and successfully tested at a 220 V$\_$rms/circuit. From the resistance increase, we estimated that the film temperature increased to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V$\_$rms/.

  • PDF

Two Case of Pulmonary Arteriovenous Fistula Treatment Depending on the Presence of Pulmonary Hypertension (폐동맥고혈압 동반여부에 따른 폐동정맥루의 치료)

  • Huh, Yun Jeong;Kim, Jeong Tae;Choi, Jae Young
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.216-220
    • /
    • 2005
  • Pulmonary arteriovenous fistulas(PAVFs) is a rare disorder that occurs in two to three children per 100,000 population. It is presented as absence of intervening capillary beds between the pulmonary artery and vein with resultant persistent right to left shunt. Other causes include trauma, liver cirrhosis, malignancy and schistosomiasis. It is mostly asymptomatic, but it may present with respiratory difficulty, cyanosis, clubbed fingers induced by right to left shunt or hemoptysis, polycythemia and epistaxis. Major complications, such as brain abscess, brain embolism, paradoxical embolism and subacute infective endocarditis can be devastating, so therapeutic intervention is recommended in all patients. However, removal of low-resistance fistulas can aggrevate pulmonary hypertension, so detection of increased pulmonary pressure is important. We report two patients : One a 42 year-old male with PAVFs treated with coil embolization, and a 42 year-old female who was treated with anticoagulants due to pulmonary hypertension.

A Study on Power Stability Improvement in the Inductive Coupled RFID Transponder System

  • Kim, Gi-Rae;Choi, Young-Kyu
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.2
    • /
    • pp.150-154
    • /
    • 2007
  • Transponders of RFID system are classified as active or passive depending on the type of power supply they use. In passive transponders the data carrier has to obtain its power from the induced voltage. The induced voltage is converted into direct current using a low loss bridge rectifier and then smoothed. In practice, the induced voltage in the transponder coil is variable according to the coupling coefficient k and the load resistance ($R_L$). Therefore, the rectified voltage is unstable and the transponder of RFID is unstable sometimes. In this paper, a voltage-dependent shunt resistor ($R_s$) circuits are designed and inserted in parallel with the load resistance of RFID transponder in order to improve the stability of power.

Transistor Wide-Band Feedback Amplifiers (트랜지스터 광대역궤환증폭기)

  • 이병선;이상배
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.5 no.1
    • /
    • pp.13-25
    • /
    • 1968
  • A detailed analysis of the transistor wide-band feedback amplifiers using the hybrid-$\pi$ equivalent circuit has been made. It is considered both for the low freqnency and for the high frequency. The expressions of the gain, bandwidth. input impedance and output impedance have been presented. It is shown that a series feedback amplifier should be driven from the voltage source and should drive into the low resistance load, and a shunt feedback amplifier should be driven from the current source and should drive into the high resistance load. It is also shown that these stages can be coupled without use of the buffer stage or coupling transformer.

  • PDF

Photovoltaic Properties of Sintered CdS/CdTe Solar Cell (소결체 ITO/CdS/CdTe 태양전지의 광전압특성)

  • 김동섭;조은철;안병태;임호빈
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.11a
    • /
    • pp.216-220
    • /
    • 1994
  • Polycrystalline CdS films have been prepared by coating a slurry, which consisted of CdS, 11w% CdCl$_2$ and appropriate amount of propylene glycol, on glass substrate and glass substrate coated with indium tin oxide(ITO) followed by sintering in a nitrogen atmosphere. CdTe slurries consisting of Te powder and Cd powder were coated on the sintered CdS films and ITO/CdS films and were sintered in nitrogen to prepare sintered CdS/CdTe and ITO/CdS/CdTe solar cells. The value of fill factor increased due to low series resistance and open circuit voltage decreased due to low shunt resistance in the ITO/CdS/CdTe solar cells.

Development of Intelligent Monitoring System for Welding Process Faults Detection in Auto Body Assembly (자동차 차체 제조 공정에서 용접 공정 오류 검출을 위한 지능형 모니터링 시스템 개발)

  • Kim, Tae-Hyung;Yu, Ji-Young;Rhee, Se-Hun;Park, Young-Whan
    • Journal of Welding and Joining
    • /
    • v.28 no.4
    • /
    • pp.81-86
    • /
    • 2010
  • In resistance spot welding, regardless of the optimal condition, bad weld quality was still produced due to complicated manufacturing processes such as electrode wear, misalignment between the electrode and workpiece, poor part fit-up, and etc.. Therefore, the goal of this study was to measure the process signal which contains weld quality information, and to develop the process fault monitoring system. Welding force signal obtained through variety experimental conditions was analyzed and divided into three categories: good, shunt, and poor fit-up group. And then a monitoring algorithm made up of an artificial neural network that could estimate the process fault of each different category based on pattern was developed.

Commutation Modeling and Characteristic Analysis of DC Motor using Circuit Parameters (회로정수를 이용한 직류전동기의 정류회로 모델링 및 특성 해석)

  • Kim, Young Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.57-62
    • /
    • 2013
  • Because of high torque and easiness of speed control, Direct Current(DC) motors have been used for a long time. But, its applications are limited in circumstance and performance, since they contained brush and commutator. The commutation characteristic gives effect to life and performance of the DC motor. Naturally, the commutation characteristic analysis is strongly required. In this paper, With the result of finite element analysis, The inductance is calculated each rotor position and applied to the voltage equations coupled with commutation equation. Also, contact resistances of brush/commutator assembly are considered using contact area and brush width converted with commutator segments. The time derivative term in the differential equation is solved in time difference method. This algorithm was applied to 2-pole shunt DC motor. We considered commutation characteristic by changing contact resistance between brush and commutator segment.

Modified Fontan Operation: Physio-anatomic Causes of Low Cardiac Output and Persistent Pleural Effusion (Fontan 수술후 저심장박출증 및 지속성 흉막 삼출액이 발생되는 해부생리학적 원인)

  • Han, Jae-Jin;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.213-221
    • /
    • 1990
  • We have experienced 62 cases of modified Fontan operations in Seoul Nat’l University Hospital from Apr. 1986 to Jul. 1989, They were 38 males and 24 females, and their age was ranged from 16 months to 15.5 years of age. [mean age : 5.73$\pm$2.99 years] There were 16 operative deaths and 2 late deaths, therefore 29% of overall mortality. Their diagnoses were as follows; 28 single ventricle, 11 tricuspid atresia, 6 DORV with LV hypoplasia, 3 pulmonary atresia with hypoplastic RV, 3 TGA with hypoplastic RV, 3 cor\ulcornerGA with hypoplastic LV and PA, 6 AV canal defects with PA, and 2 others. Low cardiac output and pleural effusion were developed frequently, so we divide 40 patients into some groups to analyze the physiologic and anatomic causes of them. By the degree of the LCO, group A was no LCO[mean amount of inotropics used: 0-5 \ulcornerg/kg/min] with 17 cases, B mild LCO [5-10] with 11, C moderate to severe LCO but alive[>10] with 8, D severe LCO to death with 4 cases. For the pleural effusion, group 1 was to be removed the chest tube within 1 week with 8 cases, group II within 3 weeks with 21 cases, group III beyond 3 weeks with 12 cases. We considered their age, diagnosis, pulmonary artery size[PA index], pulmonary artery abnormality, palliative shunt, systemic ventricular type, pulmonary artery wedge pressure, as preoperative factors, and operative methods, and as postoperative factors, CVP, LAP, arrhythmia, thrombosis, atrioventricular valvular insufficiency, etc. In the view of LCO, pulmonary artery size and PCWP were statistically significant [P<0.05], and arrhythmia, A-V valve insufficiency were inclined to the group C and D Pleural effusion was influenced by the pulmonary artery size, pulmonary artery resistance, PCWP, and CVP significantly. [P<0.05] And arrhythmia, residual shunt, and A-V valvular insufficiency were inclined to group II and III, too. As a results, the followings are to be reminded as the important factors at the care of post-Fontan LCO, and persistent pleural effusion [1] pulmonary artery size, [2] pulmonary artery resistance, [3] PCWP, [4] CVP, [5] arrhythmia, [6] residual shunt, [7]A-V valvular insufficiency.

  • PDF

Incident Light Intensity Dependences of Current Voltage Characteristics for Amorphous Silicon pin Solar Cells (비정질실리콘 pin태양전지에서 입사광 세기에 따른 전류 저압특성)

  • Jang, Jin;Park, Min
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.2
    • /
    • pp.236-242
    • /
    • 1986
  • The dependence of the current-voltage characteristics of hydrogenated amorphous silicon pin solar cells on the illumimination light intensity has been investigated. The open circuit voltage increases linearly with increasing the logarithm of light intensity up to AM 1, and nearly saturates above AM 1, indicating the open circuit voltage approaching the built-in potential of the pin solar cell above AM 1. The short circuit current density increase with light intensity in proportion to I**0.85 before and I**0.97 after light exposure. Since the series resistance devreses and shunt resistance increases with light intensily, the fill factor increases with light illumination. To increase the fill factor at high illumination in large area solar cells, t6he grid pattern on the ITO substrates should be made. Long light exposure on the solar cells gives rise to the increase of bulk resistance and defect states, resulting in the decrease of the fil factor and short circuit current density. The potential drop in the bulk of the a-Si:H pin solar cells at short circuit condition increases with decreasing temperature, and increases after long light exposure.

  • PDF

Wideband Colpitts Voltage Controlled Oscillator with Nanosecond Startup Time and 28 % Tuning Bandwidth for Bubble-Type Motion Detector (나노초의 발진 기동 시간과 28 %의 튜닝 대역폭을 가지는 버블형 동작감지기용 광대역 콜피츠 전압제어발진기)

  • Shin, Im-Hyu;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1104-1112
    • /
    • 2013
  • This paper presents a wideband Colpitts voltage controlled oscillator(VCO) with nanosecond startup time and a center frequency of 8.35 GHz for a new bubble-type motion detector that has a bubble-layer detection zone at the specific distance from itself. The VCO circuit consists of two parts; one is a negative resistance part with a HEMT device and Colpitts feedback structure and the other is a resonator part with a varactor diode and shorted shunt microstrip line. The shorted shunt microstrip line and series capacitor are utilized to compensate for the input reactance of the packaged HEMT that changes from capacitive values to inductive values at 8.1 GHz due to parasitic package inductance. By tuning the feedback capacitors which determine negative resistance values, this paper also investigates startup time improvement with the negative resistance variation and tuning bandwidth improvement with the reactance slope variation of the negative resistance part. The VCO measurement shows the tuning bandwidth of 2.3 GHz(28 %), the output power of 4.1~7.5 dBm and the startup time of less than 2 nsec.