• 제목/요약/키워드: short-circuit

검색결과 1,674건 처리시간 0.034초

스패터 양을 이용한 아크 안정성 판별에 관한 연구 (A study on determining arc stability using weight of spatter)

  • 강성구;문형순;나석주
    • Journal of Welding and Joining
    • /
    • 제15권6호
    • /
    • pp.41-48
    • /
    • 1997
  • For analyzing the characteristics of arc welding processes, an algorithm is necessary to determine the metal transfer mode, arc stability and weld quality. In this study, the weight of spatter during welding was selected for determining the arc stability, which is very relevant to the occurrence of spatter. Weld spatter occurs mainly at the moment when the short circuit is formed and also when it is broken causing the arc to restrike. Based on this fact, the arc stability can be determined by finding the suitable parameters of welding current and arc voltage which influence the weight of spatter. Through various welding experiments, the peak current, the arcing time, the short circuit time, the current and its slope at the start of short circuit were found mainly to influence the weight of spatter. For the convenient usage, an index was proposed by combining all these parameters. It was found that the index is very effective for determining the arc stability.

  • PDF

선박용 전기추진시스템의 단락상정사례의 전력특성 분석 (Power Characteristic Analysis of Assumed Short Circuit Instance of Electric Ship Propulsion System)

  • 전원;왕용필;정종화;류승각;정상용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.323-329
    • /
    • 2008
  • This paper deals with modeling and characteristic analysis of a large-powered electric ship propulsion system. Particularly, system modeling in accordance with the required shipping performance, building-up the equivalent circuit and the power analysis based on load flow have been performed. In addition, abnormal operating condition of short-circuit network is considered for investigating the safety of system components under the over-load condition. Furthermore, protective device like circuit breaker has been specified in order to make the entire system operate normally in case of short-circuit emergency.

IEC60947-2에 따른 누전차단기의 순시단락시험 과도현상에 대한 연구 (The Transient Analysis of Instant Short-Circuit Test Equipment For Earth Leakage Circuit Breaker)

  • 류행수;김명석;한규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.357-359
    • /
    • 2003
  • This paper is for the transient analysis of instant short-circuit test equipment according to the test of tripping limits and characteristics under IEC 60947-2. The in-rush current is harmful to almost equipments and the exact testing is not made because of it. LGIS has a instant short-circuit test equipment, but it is not suitable for carrying out instant short-circuit test on ELB(Earth Leakage Circuit breaker) by reason of that. Now, I am going to show a solution for that problem. After applying this method, manufacturer is going to acquire the exact testing result according to the IEC standard. Moreover, Testing laboratory will be trusted by clients.

  • PDF

개방회로, 단락회로 특성시험 및 부하시험을 이용한 30 kVA 초전도 발전기의 특성해석 (A Study on 30 kVA Super-Conducting Generator Performance using Open Circuit, Short Circuit Characteristics, and Load Tests)

  • 하경덕;황돈하;박도영;김용주;권영길;류강식
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권2호
    • /
    • pp.85-92
    • /
    • 2000
  • 30 kVA rotating-field type Super-Conducting Generator is built and tested with intensive FE(Finite Element) analysis. The generator is driven by VVVF inverter-fed induction motor. Open Circuit Characteristic(OCC) and Short Circuit Characteristic(SCC) are presented in this paper. Also, the test result under the light load(up to 3.6 kW) are given. From the design stage, 2-D FE analysis coupled with the external circuit has been performed. The external circuit includes the end winding resistance and reactance as well as two dampers. When compared with the test data, the FE analysis results show a very good agreement.

  • PDF

Study on Application of Superconducting Fault Current Limiter Considering Risk of Circuit Breaker Short-Circuit Capacity in a Loop Network System

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1789-1794
    • /
    • 2014
  • This paper suggests an application method for a superconducting fault current limiter (SFCL) using an evaluation index to estimate the risk regarding the short-circuit capacity of the circuit breaker (CB). Recently, power distribution systems have become more complex to ensure that supply continuously keeps pace with the growth of demand. However, the mesh or loop network power systems suffer from a problem in which the fault current exceeds the short-circuit capacity of the CBs when a fault occurs. Most case studies on the application of the SFCL have focused on its development and performance in limiting fault current. In this study, an analysis of the application method of an SFCL considering the risk of the CB's short-circuit capacitor was carried out in situations when a fault occurs in a loop network power system, where each line connected with the fault point carries a different current that is above or below the short-circuit capacitor of the CB. A loop network power system using PSCAD/EMTDC was modeled to investigate the risk ratio of the CB and the effect of the SFCL on the reduction of fault current through various case studies. Through the risk evaluations of the simulation results, the estimation of the risk ratio is adequate to apply the SFCL and demonstrate the fault current limiting effect.

6.6㎸/200A급 DC 리액터헝 초전도한류기의 단시간운전 및 단락시험 (Short-term Run and Short-circuit Test of 6.6㎸/200A DC reactor Type Superconducting Fault Current Limiter)

  • 안민철;이승제;강형구;배덕권;윤용수;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.10-13
    • /
    • 2003
  • 6.6㎸rms/200Arms DC reactor type superconducting fault current limiter (SFCL) has been developed. This paper deals with the manufacture and short-circuit test of the SFCL. DC reactor was the HTS solenoid coil whose inductance was 84mH. AC/DC power converter was performed as the dual-mode operation. The short-term run(1 sec) and short-circuit test of this SFCL was performed successfully. The experimental results have a similar tendency to the simulation results. In short-circuit test, at 2 cycles after the fault, fault current limitation rate was about 30%.

  • PDF

Three-phase Making Test Method for Common Type Circuit Breaker

  • Ryu, Jung-Hyeon;Choi, Ike-Sun;Kim, Kern-Joong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.778-783
    • /
    • 2012
  • The synthetic short-circuit making test to adequately stress the circuit breaker has been specified as the mandatory test duty in the IEC 62271-100. The purpose of this test is to give the maximum pre-arcing energy during making operation. And this requires the making operation with symmetrical short-circuit current that is established when the breakdown between contact gap occurs near the crest of the applied voltage. Also, if the interrupting chamber of circuit breakers is designed as the type of common enclosure or the operation is made by the gang operated mechanism that three-phase contacts are operated by one common mechanism, three-phase synthetic making test is basically required. Therefore, several testing laboratories have developed and proposed their own test circuits to properly evaluate the breaker performance. With these technical backgrounds, we have developed the new alternative three-phase making circuit.

3상 90 MVA 단시간전류시험 설비 구축 (The construction of 3-phase 90 MVA short-time withstand current testing facilities)

  • 서윤택;김용식;윤학동;김맹현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.700-702
    • /
    • 2005
  • The most electrical apparatus should be able to withstand short-time current and peak current during a specified short time until circuit breakers have interrupted fault current. It defines the short-time withstand ability of electric a apparatus to be remain for a time interval under high fault current conditions. It is specified by both dynamic ability and thermal capability. KERI(Korea Electrotechlology Research Institute) recently constructed the new short-time current and low voltage short circuit testing facilities. This paper shows short- circuit calculation of transformer and describes high current measuring system, and evaluate the result of short-time withstand test used in $3{\phi}$ 90MVA short-time current testing facilities.

  • PDF

중성선 선로 전압강하를 이용한 단락사고 방지용 보호장치 개발 (Development of Prevention Apparatus for Short-Circuit Faults Using the Line Voltage Drop of Neutral Wire)

  • 곽동걸;김진환;이봉섭
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1953-1958
    • /
    • 2012
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with such electric faults, specially short circuit faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30ms(KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problem, this paper proposes a prevention apparatus using the line voltage drop of neutral wire and some semiconductor switching devices. Some experimental tests of the proposed apparatus confirm the validity of the analytical results.

전등 부하 및 전동기 부하시 전기화재예방 제어장치의 동작 특성에 관한 연구 (A Study on Dynamic Characteristics of Electrical Fire Prevention Control Devices with a lamp and a motor load)

  • 이상호;오홍석
    • 한국산업융합학회 논문집
    • /
    • 제5권3호
    • /
    • pp.255-260
    • /
    • 2002
  • Recently, the occurrences of electrical fire have been suppressed by an earth leakage breaker(ELB), a no fuse breaker(NFB) and a fuse in case of an earth leakage, a short circuit and an over current. But it is impossible for the ELB to break the circuit in the case of the failure of pressure contacts on connecting points and the momentary short circuit. Therefore, it is require to study the constructive problem of the ELB. In this paper, we have developed the auxiliary control device, electrical fire prevention control device(EFPCD), of the ELB. And we have tested the operation characteristics of the ELB according to the load(R, L) As a result of this experiment, we could prevent the electrical fire due to the spark and the overheat occurring in the failure of pressure contacts on connecting points and the momentary short circuit.

  • PDF