• 제목/요약/키워드: short tooth

검색결과 175건 처리시간 0.026초

Characterization of dental phenotypes and treatment modalities in Korean patients with Parry-Romberg syndrome

  • Yim, Sunjin;Yang, Il-Hyung;Baek, Seung-Hak
    • 대한치과교정학회지
    • /
    • 제50권6호
    • /
    • pp.407-417
    • /
    • 2020
  • Objective: To investigate the dental phenotypes and treatment modalities (Tx-Mod) in Korean patients with Parry-Romberg syndrome (PRS) using longitudinal data. Methods: The samples consisted of 10 PRS patients, who were treated and/or followed-up at Seoul National University Dental Hospital between 1998 and 2019. Using a novel PRS severity index based on the numbers of the atrophy-involved area and asymmetry-involved item, we classified them into mild (n = 3), moderate (n = 2), and severe (n = 5). Dental phenotypes, including congenitally missing tooth (Con-Missing-Tooth), microdontia, tooth with short root (Short-Root), tooth with dilacerated root, and delayed eruption/impacted tooth, were investigated along with Tx-Mod. Results: The side of occurrence of all dental phenotypes showed 100% concordance with the side of PRS involvement. The most two common dental phenotypes were Con-Missing-Tooth and Short-Root (n = 29 and n = 17 in six patients). The sums of the average number of Con-Missing-Tooth and Short-Root increased from mild PRS to moderate PRS and severe PRS cases (1.0, 6.0, and 6.2). In terms of Tx-Mod, growth observation due to mild atrophy, fixed orthodontic treatment, and grafting were used for mild PRS cases. Tx-Mod for moderate PRS cases involved growth observation for surgery due to an early age at the initial visit. For severe PRS cases, diverse Tx-Mod combinations including unilateral functional appliance, fixed orthodontic treatment, growth observation, grafting, and orthognathic surgery were used. Conclusions: The novel PRS severity index may be useful to provide primary data for individualized diagnosis and treatment planning for PRS patients.

성장호르몬결핍이 저신장 소아의 치아발육에 미치는 영향에 대한 융합 분석 (An Convergence Analysis of the Effect of Growth Hormone Deficiency on the Development of Teeth in short stature Children)

  • 손화경;강소희;이희경
    • 한국융합학회논문지
    • /
    • 제12권6호
    • /
    • pp.39-47
    • /
    • 2021
  • 이 연구는 치아발육단계에서 성장호르몬 결핍의 영향을 알아보기 위해서 성장호르몬 결핍이나 특발성 저신장 소아와 정상 소아 간의 차이를 분석하는 것을 목적으로 한다. 영남대학교 의과대학 부속병원 소아청소년과에서 저신장으로 진단받은 소아들을 성장호르몬 결핍인 대상자와 특발성 저신장 소아로 분류하였다. 구강 파노라마와 신체지수를 계측하여 치아발육과의 관계를 분석하였다. 성장호르몬 결핍성 저신장 소아와 특발성 저신장 소아 간의 유의한 차이는 측절치에서만 나타났다. 성장호르몬 결핍성 저신장 소아와 정상 소아 간에는 모든 치아에서 성장호르몬 결핍성 저신장 소아의 발육이 유의하게 늦은 것으로 나타났다. 결론적으로 저신장 소아에서 성장호르몬 결핍성 저신장 소아나 특발성 저신장 소아 모두 신장뿐만 아니라 치아 발육 역시 영향을 받은 것으로 나타났다. 이 연구는 향후 저신장 소아의 교정치료 프로토콜의 기초자료를 제시할 수 있을 것으로 기대한다.

Short root anomaly (SRA) 환아의 교정적 처치 증례 (Orthodontic Treatment of a Child with Short Root Anomaly : a Case Report)

  • 이정은;이제우;신가영;안소연;송지현;라지영
    • 대한소아치과학회지
    • /
    • 제42권4호
    • /
    • pp.319-326
    • /
    • 2015
  • Short root anomaly (SRA)는 매우 드문 질환으로, 교정력에 의한 치근흡수에 있어서 정상적인 치아보다 더 취약하므로 처치시에 어려움이 있다. 또한, 혼합치열기 시기에 나타나는 전반적인 SRA의 경우는 진단 또한 쉽지 않다. 초기 혼합치열기환아에서 방사선 사진만으로 전반적인 SRA를 예측하기 어렵지만, 가족력이나 관련 전신질환, 또는 구강 내 다른 치아이상(tooth anomaly) 등의 요소가 있는 경우, SRA를 염두에 두어야 한다. 본 증례는 전악에 걸쳐SRA를 보이는 초기 혼합치열기 환아의 교정적 처치를 다루었다. 비록 국소적인 치아 상실이 있었으나 적절한 교정적 배열을 통해 더 이상의 과도한 치근흡수 없이 치료를 마무리 하였으며, 비교적 양호한 치료 결과를 얻었기에 이를 보고하고자 한다. 결론적으로, SRA 환자에서도 교정 치료가 가능하며, SRA가 예측되는 혼합치열기 환아에서 치근 흡수나 치아상실과 같은 합병증이 나타나지 않도록 특히 주의를 기울여야 한다.

마그네틱 픽업 방식의 CPS 신호 해석 회로에 관한 연구 (A Study of the Circuit for CPS Signal Using Magnetic Pickup)

  • 주용완;조봉수;백광렬
    • 제어로봇시스템학회논문지
    • /
    • 제17권1호
    • /
    • pp.1-5
    • /
    • 2011
  • The basic signals for electronic engine control are velocity and degree of the engine cam shaft. The CPS sensor used for this signal and magnetic pick-up type CPS sensor is more popular. It is very important thing analyze this signal correctly. If there are some mistakes at the analysis, like a noise, The engine do not working at the best status, it will generate some noise, emit exhaust fumes and waste more gases. In general way to analysis this signal, you use zero-level detector circuit and in order to reduce the error you must use another sensor like a TDC sensor. In this paper, We proposed the analysis method using electronics circuits for magnetic pick-up type CPS sensor. We designed Comparison level detector circuit, Differential circuit and Full-rectifier circuit for detected the Long tooth and Short tooth level correctly without another sensor. We expected it is useful for more reliable engine control.

근거리선로고장전류 차단시험용 Artificial line (Artificial line for short-line fault test)

  • 박승재;류형기;강영식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1783-1785
    • /
    • 2001
  • With the 4-MJ synthetic testing facilities completed, KERI can perform the circuit breaker testing up to 420 kV, 50 kA ratings. The short-line fault test is one of the necessary test items which are required for the circuit breaker, and in order to perform the short-line fault test KERI(Korea Electrotechnology Institute) has used the "new artificial line" which has small dimension and is easy to generate the saw-tooth wave. This paper describes the following items of the new artificial line. -Description of 4-kinds of artificial lines and determination of the circuit parameter of artificial line. -TRV characteristics of saw-tooth waves for each circuit. -KERI's artificial line.

  • PDF

쥐의 치수자극에 의해 유발되는 자율신경 반응과 악안면 근육활동의 변화 (CHANGES IN AUTONOMIC RESPONSES AND JAW MUSCLE ACTIVITY INDUCED BY TOOTH PULP STIMULATION IN THE RAT)

  • 유미경;박수정
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.657-665
    • /
    • 1999
  • The effects of application of mustard oil (MO), a small-fiber excitant and inflammatory irritant into the rat maxillary molar tooth pulp on arterial blood pressure and heat race, and electromyographic (EMG) activity of the jaw muscles were assessed in the anesthetized rats. In addition, Evans blue extravasation following pulpal MO application was measured. Application of MO into the tooth pulp produced a significant increase in mean arterial pressure and heat rate which gradually returned to baseline level. Application of MO into the tooth pulp induced a significant and short-lasting increase in EMG activity of digastric masseter and tongue muscle. Application of MO into the tooth pulp significantly increased the plasma extravasation of Evans blue dye. However, Application of mineral oil into the tooth pulp did not produce any significant changes in EMG activity of the digastric, masseter and tongue muscles, mean arterial pressure and heart rate, and plasma extravasation of Evans blue dye. These findings indicate that changes in arterial blood pressure, heart rate, jaw muscle activity and plasma extravasation accompanying noxious tooth pulp stimulation call be utilized as indirect measure of orofacial pain and inflammation.

  • PDF

Intermittent Administration of Parathyroid Hormone for Orthodontic Tooth Movement in Mongrel Dogs: Preliminary Study

  • Won-Ho Kim;Bo Ram Lee;Hey-Yun Kim;Minji Kim;Jin-Woo Kim
    • Journal of Korean Dental Science
    • /
    • 제16권2호
    • /
    • pp.182-191
    • /
    • 2023
  • Purpose: This study investigated the orthodontic tooth movement after weekly parathyroid hormone (PTH) injection in mongrel dogs and analyzes bone formation activity on the tension and pressure sides of the tooth movement in mongrel dogs. Materials and Methods: Three mongrel dogs were used in this study. The first premolar was extracted and orthodontic force using 150 g of closed coil springs between the canine and second premolar was applied. The low-dose PTH group (PTH_1) and high-dose PTH group (PTH_2) received weekly injections of 1.61 ㎍/kg and 3.23 ㎍/kg of PTH, respectively. The control group received weekly injections of 1 ml of saline. Clinical, histomorphometric analysis were carried out. Result: The orthodontic tooth movement was greatest in the PTH_2 group and the lowest in the control group. Fluorescence staining images showed higher bone remodeling on the tension side of the tooth movement in the PTH_1 and PTH_2 groups. PTH_2 group showed a thicker labeling band than the PTH_1 group. PTH_2 group showed the highest mineral apposition rate and bone formation rate, followed by the PTH_1 group and the control group. Conclusion: Weekly intermittent PTH injection, especially in the short-term and at higher doses with orthodontic force, successfully increased orthodontic tooth movement and bone remodeling in mongrel dogs.

유성기어 감속기에서 전위계수가 기어 강도에 미치는 영향 (The Effect of Addendum Modification Coefficient on Gear Strength to Planetary Gear Reducer)

  • 곽기석;한동섭
    • 한국기계가공학회지
    • /
    • 제10권4호
    • /
    • pp.38-43
    • /
    • 2011
  • Industrial reducer is in general use to Deck Crane. High-precision and high-efficient reducer is minimized the power-loss and energy-loss of a machine. So it contribute the price reduction and life extension. Reducer is usually using the Planetary gear reducer. Planetary gear reducer is composed the sun gear, planet gear, internal gear and casing. Industrial reducer's wear and breakage have a short-life. To solve this problem, it is using the profile-shifted-gear or tooth modification. This study was carried out the effect of addendum modification coefficient on tooth fillet bending strength to planetary reducer. Tooth fillet bending stress is calculate. And all parameter were expressed the function of addendum modification coefficient. And then stress concentration factor of tooth fillet curve was express the function of addendum modification coefficient using comparison between theory and finite element analysis.

전자기 구동장치를 이용한 재료시험기 개발 (Development of a Material Test Machine Using an Electro-Magnetic Actuator)

  • 이세한
    • 한국기계가공학회지
    • /
    • 제13권1호
    • /
    • pp.66-71
    • /
    • 2014
  • In this research, a material test machine is developed which uses a small electro-magnetic actuator and a leverage mechanism. The leverage mechanism amplifies the force from the electro-magnetic actuator. The electro-magnetic part operates more silently and cleanly than a hydraulic part. In a tooth material study, a test machine does not require a large force capacity because it handles only $4mm^2$-sectioned and short-span specimens. Conventional test machines such as those by Instron and the BOSE Enduratec ELF3200 have too high aforce capacity for a tooth material study. A test machine for a tooth material study requires an acting force only on the order of tens of Newtons (N) operating at several Hertz.

상악 구치부의 발치와 동시에 시행하는 상악동저 증강술을 이용한 임프란트 증례 (Sinus floor augmentation at the time of tooth removal)

  • 김민규;진민주;안은주
    • Journal of Periodontal and Implant Science
    • /
    • 제37권3호
    • /
    • pp.647-653
    • /
    • 2007
  • Rapid crestal bone resorption following maxillary tooth loss is further accentuated in the posterior regions because of pneumatization and enlargement of the maxillary sinuses. A treatment rationale that allows preservation and augmentation of vertical available bone at the time of posterior maxil-lary tooth extraction may offer numerous therapeutic benefits which are more short courses of ther-apy and no needs of additional surgical augmentation. The present study comprised 3 patients who had 4 posterior maxillary teeth with no evident bone between the tooth apex and sinus floor, as estimated through preoperative radiographic analysis. Sinus floor augmentation at the time of tooth extraction was chosen for the ltreatment of these patients. After the tooth was carefully extracted, the empty alveolus was thoroughly debrided and a trephine approach was performed. Particulated autogenous bone was gently pushed beyond the empty alveolus to elevate the sinus membrane using an osteotome. The distance between bone crest and si-nus floor was radiographically estimated 4 months after the first procedure. Another procedure was then carried out to place the implants of 11 mm length without another augmentation procedure. All implant were clinically stable, with no sign of infection. The presented surgical procedure performed at the time of extraction of posterior maxillary teeth in close proximity to the sinus floor allowed placement of implants of proper length.