• Title/Summary/Keyword: short through ratio

Search Result 301, Processing Time 0.027 seconds

A Novel Vertical Directional Coupler Switch with Switching Operation-Induced, Extinction Ratio-Adjusted, and Extinction Ratio-Enhanced Sections

  • Cho, Sung-Chan;Hong, Hyun-Ha;Yang, Choong-Reol;Choi, Jee-Yon;Kang, Min-Ho;Hwang, Hyun-Yong;Choi, Young-Woo;Kim, Hae-Geun;Jung, Byung-Min;Kim, Boo-Gyoun
    • ETRI Journal
    • /
    • v.24 no.2
    • /
    • pp.109-116
    • /
    • 2002
  • We propose a novel very short (< $300{\mu}m$) vertical directional coupler switch with high extinction ratios larger than 30 dB. The device consists of a switching operation induced section (SOIS), an extinction ratio adjusted section (ERAS), and an extinction ratio enhanced section (ERES). These are achieved by changing the refractive index of one core. The switching operation is induced by changing the refractive index of one core in the SOIS. The improvement of extinction ratios larger than 30 dB for both the cross and bar states is made by controlling the asymmetry of the refractive indices of both cores in the ERES. Through the ERAS, different extinction ratios between the cross and bar states at the end of the SOIS are changed to the same value. For this reason, the optimum asymmetry of the refractive indices of the cores for the maximum extinction ratios and the lengths of ERES are the same for cross and bar states. Design guidelines for high extinction ratios with large tolerances are presented.

  • PDF

Study on the Synthesis of Wool-blending Fiber Bundle and New Signs of the Curve

  • Ren Yonghua;Yu Jianyong
    • Fibers and Polymers
    • /
    • v.6 no.4
    • /
    • pp.339-342
    • /
    • 2005
  • In this paper, a hand-operating method (tiled test method) of the wool-blending sample is made out, and make use of the method, the test of wool-blending bundle in different blending ratio is accomplished. According to the test data, the synthesis method of the stretch curve is worked out and the synthesis software for the typical stretch curve of wool-blending bundle is designed. Through laboratory hand-operating method, the blending fasciculus applying to fiber bundle test can be obtained in a short time. Calculation for sampling is accomplished in the article. We bring up 9 new signs to describe the characteristics of the curve behind peak for the first time: elongation behind peak (HE), elongation percentage behind peak (HEP), relative elongation rate behind peak (RHE), total break work $(W_a)$, break work behind peak (HW), break work coefficient behind peak (HWC), elongation percentage of half-load behind peak (HEL), load percentage of half-elongation behind peak (HLE), break efficiency behind peak (HEC).

Transesterification of Vegetable Oils in Pulsed-Corona Plasma Discharge Process

  • Hyun, Young-Jin;Mok, Young-Sun;Jang, Doo-Il
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.81-87
    • /
    • 2012
  • The biodiesel production characteristics in a pulsed-corona plasma reactor has been investigated through parametric tests. Transesterification of rapeseed oil together with camelina oil was done with the change of such variables as voltage of power, molar ratio, KOH catalyst and temperature. The energetic electrons emitted from pulsed-corona plasma has contributed to the enhancement of yield on rapeseed oil in short time (15 min). The higher yield on camelina oil was observed in 5 min. The optimal parameters were shown as the voltage of 23 kV, the molar ratio of 5/1, the content of KOH catalyst of 0.6 wt% and the temperature of $28^{\circ}C$ under the rotating rate of spark gap of 900 rpm.

Load Bearing Capacity Evaluation of Continuous IPC Girder Bridge. (IPC 거더 연속교의 실교량 내하력 평가 연구)

  • Han, Man-Yop;Hwang, Eu-Seung;Jin, Kyung-Seok;Kang, Sang-Hoon;Shin, Jae-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.475-478
    • /
    • 2005
  • This study was performed to evaluate about load bearing capacity of continuos IPC Girder Bridge under and after Construction. This is Ichi-1 Bridge that is 2-40m span continuous bridge on a extension road through the Ichun and the Naesa. The result of static loading test to use a 25ton truck after construction, deflection ratio is 0.64 that is $35\%$ and average of response ratio is 0.48$\~$0.89 that is less than theoretical value. The result of dynamic loading test, the number of proper vibrations is 3.06Hz that is like theoretical value 3.61Hz, the modulus of impact is 0.235 that is bigger than specification 0.19. the load bearing capacity is minimum DB-40 that is so big value. In the result, continuos IPC Girder Bridge is safe in short period. we will evaluate long period behavior of continuos IPC Girder Bridge.

  • PDF

An Algorithm for Estimating Ep/No of UWB Signals (UWB 신호의 Ep/No 추정 알고리즘)

  • Im, Sung-Bin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9C
    • /
    • pp.1316-1322
    • /
    • 2004
  • Recently, the UWB (ultra wide-band) wireless communication technology, which provides high data transmission and is capable of linearly trading between throughput and signal-to-noise ratio (SNR), has drawn much attention for short-range wireless networks. Fully exploiting its notable features and minimizing its interference to coexisting other systems require the knowledge of SNR's at receivers In this paper, we propose an algorithm for estimating the pulse energy to noise ratio Ep/No of UWB signal with utilization of outputs from a correlator at a receiver, and evaluate the performance of the proposed algorithm through computer simulation. According to simulation results, the maximum standard deviation is about 1 13 dB with a block size of 500. Except for Ep/No=O and 2 dB cases with a block size of 500, no errors greater than 3 dB were observed in all the remaining experiments. Generally speaking, it improves as the true Ep/No, increases and as the block size increases A notable feature of the proposed algorithm is that it does not reduce the effective throughput because the estimation process does not require sending additional training signal of any specific format.

THE RELATIONSHIP BETWEEN MANDIBULAR ASYMMETRY AND TEMPOROMANDIBULAR JOINT DISC DISPLACEMENT ON MRI (하악 비대칭과 자기공명영상에서의 측두하악관절 원판변위와의 관계)

  • Choi, Young-Yuhn;Huh, Jong-Ki;Song, Yeong-Bok;Gho, Won-Gyung;Kim, Hyung-Gon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.1
    • /
    • pp.35-42
    • /
    • 2003
  • Purpose: This study was aimed to investigate the relationship between the mandibular asymmetry and the internal derangement of temporomandibular joint. Materials and methods: One hundred and sixty eight patients had been assessed through clinical examinations, panoramic radiographs and magnetic resonance imagings (MRIs), were selected. The samples were classified into three subgroups according to the severity of the mandibular asymmetries in the panoramic radiographs and the status of TMJ discs on the MRI were compared among each groups. Results: In an apparent asymmetry group, there was a significant difference in the number of temporomandibular disk displacement without reduction between the long and short side (66.7%, 18/27 joints on the short side) when the ratio of condylar process and coronoid process was used (p<0.05), but there was no statistically significant difference when the ratio of condyle and ramus was used. Conclusion: The probability of the disc displacement without reduction was higher at the side with relatively shorter condylar process on the panoramic radiograph, and also it might be more effective to use ratio of condylar process and coronoid process in the assessment of mandibular asymmetry. Therefore, a careful assessment on the temporomandibular disorders is necessary to diagnose and establish the treatment plans for the patients with a mandibular asymmetry and the panoramic radiograph can be used effectively on that way.

The Effect of Changes in Real Estate Prices on the Soundness of Korean Banks (부동산가격변동이 은행의 건전성에 미치는 영향)

  • Jung, Heonyong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.435-440
    • /
    • 2022
  • This study analyzed the impact of changes in real estate prices on the soundness of Korean banks using multiple regression models. As a result of the analysis, changes in real estate prices significantly increase the banks' non-performing loans through the increase in loans. Among macroeconomic variables, short-term interest rates were found to have a significant effect on all soundness indicators such as BIS capital adequacy ratio, non-performing loans ratio, and liquidity coverage ratio. Among the bank characteristics indicators, the loan growth rate had a significant negative effect on BIS capital adequacy ratio, and the real estate mortgage rate had a significant positive effect. In additional, it was found that non-performing loans ratio and liquidity coverage ratio had a negative effect on BIS capital adequacy ratio.

Development and Applications of A Paternity and Kinship Analysis System Based on DNA Data (유전자 분석 자료에 의한 친자 및 혈연관계 분석시스템 개발 및 활용)

  • Koo, Kyo-Chan;Kim, Sun-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6715-6721
    • /
    • 2015
  • Recently, DNA data of missing person, killed person, and missing child continue to increase but most of statistical calculation for paternity confirmation is being done through manual methods or Excel. Therefore, we need development of a software which is able to facilitate both systematic management and effective analysis of Short Tandem Repeat (STR) derived from DNA data. Without extensive testing, through a twenty-month study was developed a web-based system which performs paternity analysis and kinship analysis easily based on the various options. The former uses an existing algorithm for paternity index and the latter does Identity by descent (IBD) formula. Due to our system validated over real datasets in terms of likelihood ratio and probability of paternity, it ensures increased reliability as well as effective management and analysis of DNA data in mass disaster. In addition, it includes advanced features such as an integrated environment, user-centered interface, process automation and so on.

Analysis of fault Current Limiting Characteristics due to Ratio of Inductances between Coil 1 and coil 2 in a Flux-lock Type SFCL (자속구속형 고온초전도 전류제한기의 인덕턴스 변화에 따른 전류제한 특성 분석)

  • Park, Chung-Ryul;Lim, Sung-Hun;Park, Hyoung-Min;Choi, Hyo-Sang;Han, Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.9
    • /
    • pp.856-862
    • /
    • 2005
  • A flux-lock type SFCL consists of two coils, which are wound in parallel each other through an iron core, and a HTSC thin film connected in series with coil 2. If the current of the HTSC thin film exceeds its critical current by the fault accident, the resistance generated of the HTSC thin film, and thereby the fault current can be limited by the impedance of the flux-lock type SFCL. The amplitude of fault current can be set by the impedance of the flux-lock type SFCL. In this paper, we investigated the variance of the limiting current due to the ratio of inductances between coil 1 and coil 2 in the flux-lock type SFCL through the computer simulations and short circuit tests. In addition, both the simulation results and experimental ones were compared each other. From the comparison of both the results, the simulation results agreed well with the experimental ones.

Feasibility Study of UV-Disinfection for Water Reuse of Effluent from Wastewater Treatment Plant (용수재이용을 위한 하수처리 유출수의 UV 소독 효율 연구)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.126-137
    • /
    • 2003
  • The feasibility study of UV-disinfection system was performed for disinfection of effluent from wastewater treatment plant. Three low-pressure UV lamps of 17, 25, and 41 W were examined with various flow rates. Low-pressure UV lamps of 17W were examined with various turbidity, DOM (dissolved organic matter), and SS (suspended solid). The pilot plant was a flow-through type UV-disinfection system, and the range of exposure time varied from 5 to 40 seconds, turbidity from 0 to 40 NTU, DOM from 0 to 30 mg/L, and SS from 10 to 40 mg/L. The 41W lamp demonstrated complete disinfection showing no survival ratio in all the experimental conditions, and generally 17W and 25W lamps also showed high removal ratio over 97%. For the same UV dose (UV intensity times exposure time), high intensity-short exposure conditions showed better disinfection efficiency than low intensity-long exposure conditions. While the effects of turbidity and DOM were not apparent, the effects of SS was significant on the disinfection efficiency which indicates that SS control before UV-disinfection appears to be necessary to increase removal efficiency. Considering characteristics of effluent from existing wastewater treatment plants, cost-effectiveness, stable performance, and minimum maintenance, the flow-through type UV-disinfection system with high intensity and low-pressure lamps was thought to be a competitive disinfection system for wastewater reclamation.