• 제목/요약/키워드: short building

검색결과 697건 처리시간 0.025초

하절기 단일건물 주변 외부공간의 장·단파 복사관측과 해석 (The Observation and Interpretation of Long and Short Wave Radiation of the External Environment Surrounding a Single Building in the Summer)

  • 백창현;최동호;이부용;이인규
    • 한국태양에너지학회 논문집
    • /
    • 제39권1호
    • /
    • pp.41-49
    • /
    • 2019
  • In this study, we analyzed the relationship between four elements: long-wave radiation, the direction of the building, BVR (Building View Ratio), and cloud amount. We examined how long-wave radiations surrounding a building influences the perception of heat in the summer. The results are as follows. (1) Long-wave radiation and BVR are highly correlated regardless of geographical direction. (2) Especially, during dawn in a clear day, areas with high BVR observed high levels of long-wave radiation. (3) This correlation suggests that higher BVR in urban areas will result in a greater number of tropical nights.

장주기 지진동을 고려한 건축물 및 비구조요소의 가속도 응답 증폭비 (A Study on the Acceleration Response Amplification Ratio of Buildings and Non-structural Components Considering Long-Period Ground Motions)

  • 오상훈;김주찬
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.1-12
    • /
    • 2023
  • Structures of high-rise buildings are less prone to earthquake damage. This is because the response acceleration of high-rise buildings appears to be small by generally occurring short-period ground motions. However, due to the increased construction volume of high-rise buildings and concerns about large earthquakes, long-period ground motions have begun to be recognized as a risk factor for high-rise buildings. Ground motion observed on each floor of the building is affected by the eigenmode of the building because the ground motion input to the building is amplified in the frequency range corresponding to the building's natural frequency. In addition, long-period components of ground motion are more easily transmitted to the floor or attached components of the building than short-period components. As such, high-rise buildings and non-structural components pose concerns about long-period ground motion. However, the criteria (ASCE 7-22) underestimate the acceleration response of buildings and non-structural components caused by long-period ground motion. Therefore, the characteristics of buildings' acceleration response amplification ratio and non-structural components were reviewed in this study through shake table tests considering long-period ground motions.

Development of New Detachable Connection for Glass Fiber Reinforced Polymer Considering of Short and Long-Term Behavior

  • Park, Don-U;Hwang, Kyung-Ju;Knippers, Jan
    • 한국공간구조학회논문집
    • /
    • 제7권3호
    • /
    • pp.141-151
    • /
    • 2007
  • The appearance of many Glass Fiber Reinforced Plastic (GFRP) constructions look like ordinary steel construction, because GFRP has been imitated by the same way with the traditional steel's cross section as well as connection system. In terms of detachable connection, there was not enough appropriate option of GFRP connection, such as a traditional bolt connection for steel and wood structures. Most of all, from material characteristic of GFRP related to the deficient ductility, the shearstress principle of GFRP s not proper for the material property, which causes ineffective and not economic application of material. With this research problem, the innovative and detachable onnection system, which is more considered with appropriate material characteristic for FRP, is developed. Not only short time but also long time research with various connection variations is carried out.

  • PDF

Earthquake performance of FRP retrofitting of short columns around band-type windows

  • Kocak, Ali
    • Structural Engineering and Mechanics
    • /
    • 제53권1호
    • /
    • pp.1-16
    • /
    • 2015
  • Due to design codes and regulations and the variety of building plans in Turkey, it is very often seen that band-type windows are left for ventilation and lightening of the basements of buildings which are used for various purposes such as workplaces and storage. Therefore when the necessary support measures cannot be given, short columns are subjected to very high shear forces and so damage occurs. One of the precautions to avoid the damage of short column mechanisms in buildings where band-type windows are in the basement is to strengthen the short columns with fiber reinforced polymer (FRP). In this study, the effect of the FRP retrofitting process of the short columns around band-windowed structures, which are found especially in basement areas, is analyzed in accordance with Turkish Seismic Code 2007 (TSC 2007). Three different models which are bare frame, frame with short columns and retrofitted short columns with FRP, are created and analyzed according to TSC 2007 performance analysis methods to understand the effects of band windows in basements and the effect of FRP retrofitting.

The dynamic response of adjacent structures with the shallow foundation of different height and distance on liquefiable saturated sand

  • Jilei Hu;Luoyan Wang;Wenxiang Shen;Fengjun Wei;Rendong Guo;Jing Wang
    • Earthquakes and Structures
    • /
    • 제25권2호
    • /
    • pp.135-148
    • /
    • 2023
  • The structure-soil-structure interaction (SSSI) effect in adjacent structures may affect the liquefaction-induced damage of shallow foundation structures. The existing studies only analysed the independent effects on the structural dynamic response but ignored the coupling effect of height difference and distance of adjacent structures (F) on liquefied foundations on the dynamic response. Therefore, this paper adopts finite element and finite difference coupled dynamic analysis method to discuss the effect of the F on the seismic response of shallow foundation structures. The results show that the effect of the short structure on the acceleration response of the tall structure can be neglected as F increases when the height difference reaches 2 times the height of the short structure. The beneficial effect of SSSI on short structures is weakened under strong seismic excitations, and the effect of the increase of F on the settlement ratio gradually decreases, which causes a larger rotation hazard. When the distance is smaller than the foundation width, the short structure will exceed the rotation critical value and cause structural damage. When the distance is larger than the foundation width, the rotation angle is within the safe range (0.02 rad).

컴퓨터시뮬레이션에 의한 피난행태예측 및 안전성능평가 방법에 관한 연구(I) (A Study on the Evaluation Method of the Building Safety Performance and the during Building Fires with Computer Prediction of Occupants′ Egress Behavior Simulation)

  • 최원령;이경회
    • 한국화재소방학회논문지
    • /
    • 제3권1호
    • /
    • pp.19-28
    • /
    • 1989
  • It has been recognized that the escape facility planning is very important for effective evacuation of accupants on fire event. The ultimate goal of the escape facility planning is to evacuate occupants rapidly from building fires to the safe areas. In fire event, occupants usually gather, utilize and finally act upon information about state transient of building fire system, which is consisted of components of fire, building and accupant during the ralatively short period of the fire event. That is, occupants' egress behavior is largely dependent upon building fire system. Therefore, comprehensive study for the relationship between building fire system and occupants' egress behavior is needed. This study aims to suggest the pre -occupancy evaluation method of the life safety performance for the architectural design based on prediction of occupants' egress behavior during building fires with computer simulation.

  • PDF

400MHz 대역 신호의 건물내 전달 특성에 관한 연구 (A Study on the Transmission Characteristics of 400MHz Signal in a Building)

  • 차용성;강병권
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2001년도 하계 학술대회 논문집(KISPS SUMMER CONFERENCE 2001
    • /
    • pp.17-20
    • /
    • 2001
  • 논문에서는 마이크로프로세서와 ISM 대역에서 동작하는 RF 모듈을 사용하여 근거리 통신용 송수신 시스템을 구현하였고, 그 성능을 측정하였다. 기저 대역 데이터(random number)를 발생시켜 데이터 전송하고, 수신측에서는 RF 모듈에서 복조된 데이터를 PC를 사용하여 확인하였고, 수신 감도는 스펙트럼으로 측정하였다. 본 실험에서 사용한 RF 모듈은 400MHz 대역에서 동작하며, FM 방식을 사용한다. 본 대학의 산학협동관 건물내에서 측정한 결과 거리에 따른 신호 감쇠와 신호 수신 감도 그리고 비트 오율을 측정할 수 있었으며, 이를 이용하여 건물 내에서의 근거리 통신 성능을 확인하였다.

  • PDF

건물의 단기부하 예측을 위한 기상예측 모델 개발 (Development of Weather Forecast Models for a Short-term Building Load Prediction)

  • 전병기;이경호;김의종
    • 한국태양에너지학회 논문집
    • /
    • 제38권1호
    • /
    • pp.1-11
    • /
    • 2018
  • In this work, we propose weather prediction models to estimate hourly outdoor temperatures and solar irradiance in the next day using forecasting information. Hourly weather data predicted by the proposed models are useful for setting system operating strategies for the next day. The outside temperature prediction model considers 3-hourly temperatures forecasted by Korea Meteorological Administration. Hourly data are obtained by a simple interpolation scheme. The solar irradiance prediction is achieved by constructing a dataset with the observed cloudiness and correspondent solar irradiance during the last two weeks and then by matching the forecasted cloud factor for the next day with the solar irradiance values in the dataset. To verify the usefulness of the weather prediction models in predicting a short-term building load, the predicted data are inputted to a TRNSYS building model, and results are compared with a reference case. Results show that the test case can meet the acceptance error level defined by the ASHRAE guideline showing 8.8% in CVRMSE in spite of some inaccurate predictions for hourly weather data.

Predicting the lateral displacement of tall buildings using an LSTM-based deep learning approach

  • Bubryur Kim;K.R. Sri Preethaa;Zengshun Chen;Yuvaraj Natarajan;Gitanjali Wadhwa;Hong Min Lee
    • Wind and Structures
    • /
    • 제36권6호
    • /
    • pp.379-392
    • /
    • 2023
  • Structural health monitoring is used to ensure the well-being of civil structures by detecting damage and estimating deterioration. Wind flow applies external loads to high-rise buildings, with the horizontal force component of the wind causing structural displacements in high-rise buildings. This study proposes a deep learning-based predictive model for measuring lateral displacement response in high-rise buildings. The proposed long short-term memory model functions as a sequence generator to generate displacements on building floors depending on the displacement statistics collected on the top floor. The model was trained with wind-induced displacement data for the top floor of a high-rise building as input. The outcomes demonstrate that the model can forecast wind-induced displacement on the remaining floors of a building. Further, displacement was predicted for each floor of the high-rise buildings at wind flow angles of 0° and 45°. The proposed model accurately predicted a high-rise building model's story drift and lateral displacement. The outcomes of this proposed work are anticipated to serve as a guide for assessing the overall lateral displacement of high-rise buildings.

Effect of building proximity on external and internal pressures under tornado-like flow

  • Sabareesh, G.R.;Cao, Shuyang;Wang, Jin;Matsui, Masahiro;Tamura, Yukio
    • Wind and Structures
    • /
    • 제26권3호
    • /
    • pp.163-177
    • /
    • 2018
  • Tornadoes are one of the world's deadliest natural phenomena. They are characterized by short life span and danger. It has been observed through post-damage surveys that localities with large numbers of buildings suffer major damage during a tornado attack resulting in huge loss of life and property. Thus,it is important to study interfering buildings exposed to tornado-like vortices. The present study focuses on external and internal pressures developed on building models exposed to translating tornado-like vortices in the presence of an interfering building model. The effects of translating speed and swirl ratio of a tornado-like vortex on external and internal pressures for a principal building in the vicinity of an interfering building are investigated. Results indicate that external and internal pressures are enhanced or reduced depending on the location of the interfering building with respect to the principal building.