• Title/Summary/Keyword: shoes insole

Search Result 55, Processing Time 0.018 seconds

The Effects of the Height and the Quality of the Material of Popular Heel-up Insole on the Mean Plantar Foot Pressure during Walking (보행시 보급형 키 높이 인솔의 높이와 재질이 평균 족저압에 미치는 영향)

  • Lee, Joong-Sook;Kim, Doo-Hwan;Jung, Bu-Won;Han, Dong-Wook;Park, Don-Mog
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.479-486
    • /
    • 2011
  • This study determined the effects of the height and the quality of the material of popular heel-up insole on mean plantar foot pressure during walking. Seven healthy college students who are studying at S university in Busan were as participants in this study. After sufficiently explaining about the research to the subjects before the experiment, mean plantar foot pressures were examined using F-Scan Pressure Measure System 5.23 for the gait with shoes inserted insole and the data were compared among the height and the quality of material of insoles. In the result, there was a difference significantly in the mean plantar foot pressure followed the height of insoles both left and right. Especially, mean plantar foot pressure in left indicated significantly lower in 3 cm and 5 cm insoles than in 0 cm and 1 cm insoles. Also mean plantar foot pressure in right showed significantly lower in 3 cm and 5 cm insoles than in 0 cm, and indicated significantly lower in 5 cm insoles than in 1 cm and 3 cm insoles. The mean plantar foot pressure followed the quality of the material of insoles were different significantly. In left, the mean plantar foot pressure of urethane poly-acetyl insole was lower significantly than urethane poly-acetyl inserted air insole, power-gel insole and jelly insole. And the mean plantar foot pressure of urethane poly-acetyl insole was lower significantly than power-gel insole and jelly insole in right. We showed that 3 cm and 5 cm insoles in the height of insoles and Urethane poly-acetyl insole in the quality of material were suitable to reduce a fatigue which is felt in plantar foot during the walking.

Comparison of the Contact Area, Maximum Pressure, Maximum Average Pressure and Maximum Force between Functional Insoles and General Insoles (기능성 인솔과 일반 인솔의 발에 대한 접촉 면적, 최대 압력, 최대 평균압력 및 최대 힘 비교)

  • Lee, Su-Kyoung
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.431-441
    • /
    • 2022
  • Purpose: The purpose of this study was to compare the changes in the contact area, maximum pressure, maximum mean pressure, and maximum force of functional insoles and general insoles when walking. Methods: Foot pressure was measured by the ignition of functional insoles and general insoles on Company N shoes. The foot pressure was measured using a precision pressure distribution meter (Pedar - X mobile system, Novel, Germany). Each insole sensor contained 99 independent cells and was inserted between the foot and the shoe. A wireless Bluetooth-type program was used to measure the pressure detected by the measuring insoles. In order to eliminate adaptation and fatigue caused by wearing the guide during the experiment, sufficient rest was taken between each experiment, and the wearing order was randomly selected. Results: Functional insole significantly increased the forefoot and midfoot (medial, lateral) (p<0.05), while total foot, forefoot, and rearfoot peak pressure significantly decreased (p < 0.05) compared to the general insole. Conclusion: In the functional insole, a high contact area was measured inside, even in the middle of the foot, leading to a proper change in foot pressure. It was confirmed that the contact area was reduced and dispersion occurred well. In addition, it was found that the maximum pressure in the front and back of the entire foot was reduced, so the weight pressure dispersion in the functional insole was evenly distributed, and the maximum average pressure change was similar.

Top shoes foot pressure basis of the comparison analysis combine conical top foundation walking upon ground conditions (보행시 지반조건에 따른 팽이기초를 접목시킨 신발 족저압 분포 비교분석)

  • Kim, Yeon-Deok;Kim, Seg-Jin;Min, Byeong-Heon;Kim, Sang-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.20-28
    • /
    • 2019
  • This study comparatively analyzes general walking shoes on the conical top foundation of the ground condition and the pressure distribution during walking with shoes that are currently under development. Two categories of footwear were used: general footwear and a footwear conical top foundation that is currently under development. Experiments were carried out on hard ground and sandy soil in 15 male twenties that satisfy the conditions of normal foot wearing 260 mm. The pressure during walking was measured using Techstorm's Wireless Insole System, and foot pressure was measured in 7 zones of the foot. Studies have shown different maximum forces, average pressures, and pressure distributions depending on the shoe and ground conditions. This study shows that shoes with general low pressure dispersion effects depending on the feet in hard ground and sand ground are different from shoes with the conical top foundation that is currently under development. It is expected that it will be useful for the development of shoes that can be worn in all hard ground and sandy ground by selecting various rubber materials through further research.

Impact Characteristics of Multi-Density Insoles for DM Shoes (당뇨화 다밀도 안창의 충격특성)

  • 금영광;정임숙;강성재;김영길;김명웅;김영호
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.31-36
    • /
    • 2003
  • Impact characteristics of six DM(Diabetes Mellitus) shoe insole materials (Podian, Plastazote black, Plastazote white, Flexible PU foam, Podialene 200 blue and Podia flex) and three multi-density insoles (AP, OS and PW insoles) were determined in the present study, using a self-designed impact measurement system. The coefficient of restitution, the median frequency and the attenuation index were calculated for each material, based on impact forces and linear accelerations. Podian revealed the superiority in the coefficient of restitution and the attenuation index. The median frequency of the Flexible PU foam was the smallest. Results also showed that the heel region was the most impact-attenuated among other areas in the insole. OS insole showed the better characteristics in the coefficient of restitution and the median frequency. but there was no significant difference in the attenuation index. Similar impact characteristics were found in all areas in PW insole. since it was basically of the same dual-density polyurethane.

Forecasting and Analysis of Customized Shoes Design in Domestic and Overseas Brands (국내외 커스텀 슈즈 디자인 현황 및 전망)

  • Byun, Hee Jean;Byun, Trina Hyunjin
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.382-390
    • /
    • 2016
  • This study has investigated the status and overview of design characteristics of customized shoes, which receives much recognition at domestic and overseas markets. Based on the market research on current consumer lifestyle and needs of the custom-shoes(which is an abbreviation of customized shoes), this study has provided its development directions, views and demands. The design types of custom-shoes have been broadly divide into two: firstly 'style centered custom-shoes'; secondly 'function centered custom-shoes'. Style centered custom-shoes are specifically divided into 3 types; first, formal custom-shoes; second, sports and casual custom-shoes; and lastly, bespoke shoes. Function centered custom-shoes design refers to enhancing the function of personal soleprint which has to be designed by delicately detailed insole and outsole, rather than alignment of exterior parts of the shoes. These are used in professional sports shoes and also include orthopedics footwear and grafted footwear for people who have disabled on foot. Custom footwear market has been highly expanded and has entered value-added market according to increasing interest in foot health and shopping trends on shoes buying like taking shoes as personal expression in accordance with a variety of places and situations. In the near future, custom-shoes can be produced in a couple of days due to the technological advance of 3D scanners and 3D printers. This phenomenon will wants more demands of specific shoes experts such as custom-design consultants or shoes fitting experts, who can overcome limitations of online custom-shoes stores.

Analyzing the Effect of Insole Materials on Vibration and Noise Reduction between Floors (층간소음 방지를 위한 인솔 재질별 진동 및 소음 평가)

  • Seungnam Min;Heeran Lee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.47 no.1
    • /
    • pp.110-122
    • /
    • 2023
  • The COVID-19 pandemic increased people's time at home and caused an 80% increase in noise disputes between floors. The purpose of this study is to propose suitable materials for making indoor shoes (insoles) to minimize noise between floors. Subjects without back pain and leg-related disease (e.g. arthritis, etc.) from three different age groups (childhood, adolescence, and adulthood) were recruited for the study. Five polymer insole materials were considered: Chloroprene Rubber (CR foam), Ethylene Propylene Diene Monomer (EPDM foam), Natural Latex foam, Ethylene Vinyl Acetate (EVA foam), and Polyurethane (PU foam). From these materials, 20 combinations were prepared and randomly tested for noise and vibration. The results revealed a significant difference in noise and vibration levels based on the type of material used and the age of the subject. Nevertheless, all materials under consideration successfully reduced noise and vibration; in particular, type A-C greatly decreased. The CR foam material was especially effective at noise and vibration reduction (p<.01). This study suggests that adding insoles into socks that children wear at home could reduce noise vibration and disputes between floors.

Effect of Heel-heights of Insole on Balance in Healthy Adults (정상성인의 인솔 높이가 균형에 미치는 영향)

  • Oh, Myoung-Hwa;Lee, Jeon-Hyeong;Kwon, Yoo-Jung;Lee, Jong-Dae;Lee, Myoung-Hee;Kim, Kyung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.2
    • /
    • pp.79-86
    • /
    • 2009
  • Purpose:The purpose of this study was to investigated the effect of stability on heel-heights of insole in healthy adults. Methods:Subjects of 39 males measured stability index of the Biodex Stability System(BSS) by wearing shoes of 2cm, 5cm insoles including bare feet. The BSS was consisted of a movable balance platform and the platform was interfaced with computer software that enables the device to serve as an assessment of balance performance. Stability index of the BSS included overall stability index(OSI), anteroposterior stability index(APSI), mediolateral stability index(MLSI). In the BSS, subjects were asked to step on to the platform of the BSS and assume a comfortable position while maintaining slight flexion in the knees, looking straight ahead. Subjects were trained for 10min for adaptation to the heel-height of insole and then they maintained double limb stance for 2min. Biodex platform set to convert Lv.8 into Lv.1 gradually. Results:There were statistically significant differences between heel-heights of insole and stability index of OSI, APSI, and MLSI(p<.05). The result of post-hoc test were as follows; 1)OSI had significant differences between bare feet and 2cm, 5cm. 2)APSI had significant differences between bare feet and 2cm, 5cm. 3)MLSI had significant differences between bare feet and 2cm, 5cm(p<.05). Conclusions:We found that the more heels of insole high, the more stability index increases. In particular, balance index of insole above 5cm more increased and we could acknowledge that the insole above 5cm more effected balance of healthy adults.

  • PDF

Development of an Embedded Foot Pressure Measurement System Using Time Division Measurement Method (시분할 측정기법을 이용한 임베디드 족압 측정 시스템 설계)

  • 김시경
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.11
    • /
    • pp.1022-1027
    • /
    • 2004
  • In this paper, an embedded foot pressure measurement system is proposed to measure foot pressure based on the embedded Linux system. To measure foot pressure data and to evaluate foot pressure distribution for the different insoles, FSR sensor, A/D converter, iPAQ PDA, and a time division measurement method are employed in the system. Utilizing this system, the foot pressure analysis has been performed for the different four shoes. The number of foot pressure/voltage conversion circuits are drastically decreased by the proposed time division measurement method from 406 to 14. The experimental results for the sandal, slipper, oxford shoes and sneakers demonstrate that the proposed system successfully performs the foot pressure measurement.

Comparative Analysis of Plantar Pressure and Comfort Level in Developed-Domestic and Import Comfort Shoes for Elderly (고령층용 국내 개발 및 수입 컴포트화의 족저압 및 착화감 비교 분석)

  • Kim, Jae-Won;Choi, Jin-Seung;Park, Tae-Hyun;Tack, Gye-Rae;Choi, Kook-Lyeol;Lee, Sung-Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.4
    • /
    • pp.442-449
    • /
    • 2013
  • This study was to compare a domestic comfort shoes to the popular import(SAS$^{(R)}$) to gain a better understanding in biomechanical characteristics for shoe design for the elderly. For each shoe type, morphologic dimensions, shock absorption, and flexibility were assessed. From subjects(n = 20, $72.4{\pm}5.5$ years, $67.7{\pm}7.9$ kg), mean peak pressure(MPP) and contact area(CA) at the plantar surface were analyzed. The domestic shoes reflecting anatomic contour of the plantar surfaces of Asians resulted in wider CA(by 30.4 $cm^2$), higher shock absorption(by 2.4%) and stiffness(by 0.5 N/mm) than the import. With the domestic shoes, significantly less MPPs were found at the forefoot(by 42~49%) regions(p < .05) and higher CA was noted additionally at hallux and lessor toes(by 26~63%). More anatomically-contoured insole and favorable mechanical characteristics may help reduce the plantar pressures more effectively and more evenly, especially across the central forefoot and midfoot regions of the plantar surface, especially for the design of the comfort shoes for the elderly.

The Optimization of the Number and Positions of Foot Pressure Sensors to Develop Smart Shoes

  • Yoo, Sihyun;Gil, Hojong;Kim, Jongbin;Ryu, Jiseon;Yoon, Sukhoon;Park, Sang Kyoon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.395-409
    • /
    • 2017
  • Objective: The purpose of this study was to optimize the number and positions of foot pressure sensors using the reliability analysis of the center of pressure (COP) in smart shoes. Background: Foot pressure can be different according to foot region, and it is important which region of the foot pressure needs to be measured. Method: Thirty adults (age: $20.5{\pm}1.8years$, body weight: $71.4{\pm}6.5kg$, height: $1.76{\pm}0.04m$) participated in this study. The foot pressure data were collected using the insole of Pedar-X system (Novel GmbH, USA) with a sampling frequency of 100Hz during 1.3m/s speed walking on the treadmill (Instrumented treadmill, Bertec, USA). The intraclass correlation coefficients (ICC) were calculated between the COP positions using 4, 5, 6, 7, 8, and 99 sensors, while one-way repeated measure ANOVA was performed between the standard deviation (SD) of the COP positions. Results: The medio-lateral (M/L) COP position using 99 sensors was positively correlated with the M/L COP positions using 6, 7, and 8 sensors; however, it was not correlated with the M/L COP positions using 4 and 5 sensors during landing phase (1~4%) (p<.05). The antero-posterior (A/P) COP position using 99 sensors was positively correlated with the A/P COP positions using 4, 5, 6, 7, and 8 sensors (p<.05). The SD of the COP position using 99 sensors was smaller than the SD of the M/L COP positions using 4, 5, 6, 7, and 8 sensors (p<.05). Conclusion: Based on our findings, it is desirable to arrange at least 6 sensors in smart shoes. Application: The study of optimizing the number and positions of foot pressure sensors would contribute to developing more effective smart shoes using foot pressure technology.