• 제목/요약/키워드: shoe insole

검색결과 44건 처리시간 0.019초

신발장착형 보행분석 트래커의 사용자경험 분석 (User Experience Analysis of a Shoe-mounted Gait Analysis Tracker)

  • 김시연;정다희;이주영;권지현;임대영;정원영
    • 한국의류산업학회지
    • /
    • 제23권3호
    • /
    • pp.390-405
    • /
    • 2021
  • Gait analysis trackers have been developed to monitor daily gait patterns to improve users' running performance and reduce the risk of injuries. A variety of gait analysis trackers are available on the market(e.g., foot pods, insoles). Depending on the type of gait analysis tracker, users' discomfort or satisfaction as well as required properties may differ. Hence, the purpose of this study was to compare and analyze user experience of three different types of commercial shoe-mounted gait analysis trackers and their mobile applications in a laboratory environment using questionnaires based on actual experiences of each product. Ten males and ten females who regularly enjoy walking and running exercises participated in the experiment. After the participants set up the tracker and application themselves without support from researchers, ten to thirty minutes' exercise was permitted on each product. Following this, the participants answered questionnaires containing evaluation variables on the device and mobile application, as well as satisfaction, intention to use, recommendation, and purchase. In addition, they were asked questions about the attractive features and shortcomings of each device and application. The results showed that the PRO-SPECS® smart insole was preferred over the others for ease of use, perceived durability, psychological burden of the design, and usefulness of the information provided by the application. Along with the results of questionnaire, this study also discussed strategies and recommendations for future product design and development.

유산소 운동능력 향상을 위한 중량물 부가 신발의 기능성 평가 (The Evaluation of an additional Weight Shoe's Function developed for the Improvement of Aerobic Capacity)

  • 곽창수;김희석
    • 한국운동역학회지
    • /
    • 제14권3호
    • /
    • pp.67-82
    • /
    • 2004
  • The purpose of this study was to evaluate the function and the safety of an additional weight shoe developed for the improvement of aerobic capacity, and to improve some problems found by subject's test for an additional weight shoe. The subjects employed for this study were 10 college students. 4 video cameras, AMTI force platform and Pedar insole pressure distribution measurement device were used to analyze foot motions. The results of the study were as follows: 1 The initial achilles tendon angle and initial rearfoot pronation angle of an additional weight shoe during walking were 183.7 deg and 2.33 deg, respectively, and smaller than a barefoot condition. Maximum achilles tendon angle and the angular displacement of achilles tendon angle were 185.35 deg and 4.21 deg respectively, and smaller than barefoot condition. Thus rearfoot stability variables were within the permission value for safety. 2. Maximal anterior posterior ground reaction force of additional weight shoe was appeared to be 1.01-1.2 B.W., and was bigger than a barefoot condition. The time to MAPGRF of an additional weight shoe was longer than a barefoot condition. Maximal vertical ground reaction force of additional weight shoe was appeared to be 2.3-2.7 B.W., and was bigger than a barefoot condition in propulsive force region. But A barefoot condition was bigger in braking force region. The time to MVGRF of an additional weight shoe was longer than a barefoot condition. 3. Regional peak pressure was bigger in medial region than in lateral region in contrast to conventional running shoes. The instant of regional peak pressure was M1-M2-M7-M4-M6-M5 -M3, and differed form conventional running shoes. Regional Impulse was shown to be abnormal patterns. There were no evidences that an additional weight shoe would have function and safety problems through the analysis of rearfoot control and ground reaction force during walking. However, There appeared to have small problem in pressure distribution. It was considered that it would be possible to redesign the inner geometry. This study could not find out safety on human body and exercise effects because of short term research period. Therefore long term study on subject's test would be necessary in the future study.

The Effect of Protective Socks with Functional Insoles on Plantar Foot Pressure in Diabetes Patients

  • Kim, Hyun Soo;Jung, Do Young
    • The Journal of Korean Physical Therapy
    • /
    • 제30권6호
    • /
    • pp.224-228
    • /
    • 2018
  • Purpose: The most common cause of plantar ulceration is an excessive plantar pressure in patients with peripheral neuropathy. Foot orthosis and therapeutic footwear have been used to decrease the plantar pressure and prevent the plantar ulceration in in diabetes patients. We investigated whether protective sock with functional insoles reduce plantar pressure while walking in 17 diabetes patients. Methods: An in-shoe measurement device was used to measure the peak plantar pressure while walking. Peak plantar pressure data were collected while walking under two conditions: 1) wearing diabetic sock and 2) wearing the protective sock with functional insoles. Each subject walked 3 times in 10-m corridor under three conditions, and data were collected in 3 steps in the middle of corridor with in right and left feet, respectively. Pared t-test was used to compare the peak plantar pressures in three plantar areas under these two conditions. Results: The protective sock with functional insoles significantly reduced the peak plantar pressure on the lateral rearfoot, but significantly increased the peak plantar pressure on the middle forefoot, and medial midfoot (p<0.05). However, there were not significant in medial and lateral forefoot, lateral midfoot, and medial rearfoot between diabetic sock and the protective sock conditions (p>0.05). Conclusion: The protective sock with functional insoles reduced plantar pressures in the rearfoot and supported the medial longitudinal arch. However, it is necessary to change the position of metatarsal pad in the insole design of forefoot area to prevent diabetic foot ulceration.

시니어전용 기능성 깔창의 체계적인 개발 및 효과분석 (Systematic Development and Effect Estimation of the Functional Insoles for Seniors)

  • 김용덕;이동형
    • 산업경영시스템학회지
    • /
    • 제38권4호
    • /
    • pp.184-192
    • /
    • 2015
  • Korea has already entered into an aging society. In recent decades, the health problems for seniors has received considerable interest. We often see the elderly who have been struggled from discomfort or illness of the foot. Those foot related problems mainly cause from the use of improper shoes. Recently, shoe makers sell the shoes for seniors, so called comfort shoes, but the shoes are too expensive for seniors to buy easily. In this paper, we develop cheap insoles for seniors as an alternative of the comfort shoes and suggest the systematic process for the insoles development. This systematic process is as follows: 1) Survey the literature about the market of insole, 2) Investigate the standard size of body and foot for the seniors in Korea, 3) Analyze the customer needs by survey, 4) Study the walking pattern by experiments, and 5) Develop the novel insole for the seniors to relieve the inconveniences related with foot. From the newly developed insoles, the company B gains the sales increasing effect approximately 30% over through the increase in consumer satisfaction and company reputation and secures for intellectual property rights. Using the database from Korea Research Institute of Standards and Science, the reliability of developing technology of the functional insole has been obtained. The seniors are also enable to choose an alternative of comfort shoes for foot health. In the future, the insoles developed from this study have wide applications in the medical, cosmetic fields, and leisure sports fields. Accordingly, it seems to require more systematic studies utilizing Walk Analyzer and Foot Pressure Meter.

런닝화의 미드솔 경도가 하지 근육의 피로와 충격력에 미치는 영향 (The Effect of Midsole Hardness of Running Shoe on Fatigue of Lower Extremity Muscles and Impact Force)

  • Kim, Eonho;Lim, Kyuchan;Cho, Seunghyun;Lee, Kikwang
    • 한국운동역학회지
    • /
    • 제29권3호
    • /
    • pp.167-172
    • /
    • 2019
  • Objective: The aim of this study was to investigate the effect of midsole hardness of running shoe on muscle fatigue and impact force during distance running. Method: Ten healthy college recreational runners who were performing distance running at least three times a week participated in this experiment. They were asked to run for 15 minutes in the treadmill at 10 km/h with running shoes having three different types of midsole hardness (Soft, Medium, Hard). EMG signal and insole pressure were collected during the first and last one minute for each running trials. Data were analyzed using a one-way analysis of variance (ANOVA) with repeated measures. Results: Midsole hardness did not affect the consistency of stride length. For the median frequency of the EMG signal, only VL was affected by midsole hardness; that of medium was greater than other midsoles (p<.05). The loading rate of impact forces increased by midsole hardness (p<.01). Conclusion: Although soft midsole could attenuate impact forces at heel contact, it might have a negative effect on the fatigue of muscle which could decelerate the body after heel contact. Therefore, it is necessary to select the optimum hardness of midsole carefully for both reduction impact forces and muscle fatigue.

고령층용 국내 개발 및 수입 컴포트화의 족저압 및 착화감 비교 분석 (Comparative Analysis of Plantar Pressure and Comfort Level in Developed-Domestic and Import Comfort Shoes for Elderly)

  • 김재원;최진승;박태현;탁계래;최국렬;이성재
    • 한국정밀공학회지
    • /
    • 제30권4호
    • /
    • pp.442-449
    • /
    • 2013
  • This study was to compare a domestic comfort shoes to the popular import(SAS$^{(R)}$) to gain a better understanding in biomechanical characteristics for shoe design for the elderly. For each shoe type, morphologic dimensions, shock absorption, and flexibility were assessed. From subjects(n = 20, $72.4{\pm}5.5$ years, $67.7{\pm}7.9$ kg), mean peak pressure(MPP) and contact area(CA) at the plantar surface were analyzed. The domestic shoes reflecting anatomic contour of the plantar surfaces of Asians resulted in wider CA(by 30.4 $cm^2$), higher shock absorption(by 2.4%) and stiffness(by 0.5 N/mm) than the import. With the domestic shoes, significantly less MPPs were found at the forefoot(by 42~49%) regions(p < .05) and higher CA was noted additionally at hallux and lessor toes(by 26~63%). More anatomically-contoured insole and favorable mechanical characteristics may help reduce the plantar pressures more effectively and more evenly, especially across the central forefoot and midfoot regions of the plantar surface, especially for the design of the comfort shoes for the elderly.

균형과 보행분석을 위한 스마트 인솔의 신뢰도와 타당도 분석 (The Reliability and Validity of Smart Insole for Balance and Gait Analysis)

  • 이병권;한동욱;김창용;김기영;박대성
    • 대한통합의학회지
    • /
    • 제9권4호
    • /
    • pp.291-298
    • /
    • 2021
  • Purpose: The Pedisole is a newly developed shoe-mounted wearable assessment system for analyzing balance and gait. This study aimed to determine the reliability and validity of the parameters provided by the system for static balance and gait analysis of healthy adults. Methods: This study included 38 healthy adults (22.4±1.9 years) with no history of injury in the lower limbs. All participants were asked to perform balance and gait tasks for undertaking measurements. For analysis of balance, both the smart Pedisole and Pedoscan systems were concurrently used to analyze the path length of the center of pressure (COP) and the weight ratio of the left and right for 10 s. Gait was measured using the smart Pedisole and GaitRite walkway systems simultaneously. The participants walked at a self-selected preferred gait speed. The cadence, stance time, swing time, and step time were used to analyze gait characteristics. Using the paired t-test, the intra-class coefficient correlation (ICC) was calculated for reliability. The Spearman correlation was used to assess the validity of the measurements. In total, data for balance from 36 participants and the gait profiles of 37 participants were evaluated. Results: There were significant differences between the COP path lengths (p<.050) derived from the two systems, and a significant correlation was found for COP path length (r=.382~.523) for static balance. The ICC for COP path length and weight ratio was found to be greater than .687, indicating moderate agreement in balance parameters. The ICC of gait parameters was found to be greater than .697 except for stance time, and there was significant correlation (r=.678~.922) with the GaitRite system. Conclusion: The newly developed smart insole-type Pedisole system and the related application are useful, reliable, and valid tools for balance and gait analysis compared to the gold standard Pedoscan and the GaitRite systems in healthy individuals.

외측 뒤꿈치 당뇨발 환자의 보행 중 발바닥 전단응력 및 압력분포 (Plantar Shear Stress and Normal Pressure in Lateral Heel Diabetic Foot Patients During Walking)

  • 황성재;박선우;이진복;류기홍;김영호
    • 한국정밀공학회지
    • /
    • 제24권1호
    • /
    • pp.118-125
    • /
    • 2007
  • In this study, we analyzed the plantar shear stress and normal pressure in lateral heel diabetic foot patients during walking by using in-shoe local shear stress and plantar pressure measurement systems. The shear force transducer based on the magnetic-resistive principle, was a rigid 3-layer circular disc. Shear transducers were mounted on the locations of four metatarsal heads and heel in the insole. Twelve normal subjects and three diabetic foot patients with diabetic neuropathy in the lateral heel participated in this study. The center of pressure in lateral heel diabetic foot patients moved more medially and directed toward the first, medial to the second metatarsal heads, and the hallux during late stance, making pressure at the medial heel and the second metatarsal head significantly larger than in the normal. Shear stress at the heel changed significantly in early stance and the magnitude of shear stresses in each metatarsal head also changed. Further studies would be very helpful to design foot orthoses in patients with diabetic neuropathy or other diseases.

보행시 지반조건에 따른 팽이기초를 접목시킨 신발 족저압 분포 비교분석 (Top shoes foot pressure basis of the comparison analysis combine conical top foundation walking upon ground conditions)

  • 김연덕;김석진;민병헌;김상환
    • 한국산학기술학회논문지
    • /
    • 제20권9호
    • /
    • pp.20-28
    • /
    • 2019
  • 본 논문은 지반 조건에 따라 현재 개발 중인 팽이기초를 접목한 신발과 일반적인 신발인 워킹화의 보행시 압력분포의 비교분석에 대한 연구이다. 일반적인 신발, 현재 개발 중인 팽이기초를 접목한 신발 두 가지 카테고리의 신발이 본 연구에 사용되었으며, 실험 대상은 260mm를 착용하는 정상발의 조건에 만족하는 15명의 20대 남성을 대상으로 단단한 지반, 모래 지반에서의 실험을 실시하였다. 보행 시 압력의 측정은 Techstorm사의 무선 Insole System 을 사용하여 측정하였으며 발의 7 Zone에서 족저압을 측정하였다. 연구 결과 신발과 지반 조건에 따라 다른 최대 힘, 평균 압력, 압력 분포도를 나타냈으며, 본 연구 결과 단단한 지반 및 모래 지반에서 발 부위에 따라 족저압 분산 효과가 일반적인 신발과 현재 개발 중인 팽이기초를 접목한 신발이 서로 상이한 것을 확인할 수 있었다. 향후 보다 지속적인 연구를 통해 다양한 고무 소재를 선택하여 추가적인 실험을 통해 단단한 지반 및 모래 지반에서 모두 착용 가능한 신발의 개발에 유용하게 사용될 것으로 기대된다.

기능성 전문테니스화의 족저압력분포 분석 (A Study of In-sole Plantar Pressure Distribution in Functional Tennis Shoes)

  • 이중숙;김용재;박승범
    • 한국운동역학회지
    • /
    • 제14권3호
    • /
    • pp.99-118
    • /
    • 2004
  • The aim of this study is to evaluate tennis shoes's plantar pressure distribution in tennis prayers and to determine the influence of the shoe on various tennis movements. When investigating the biomechanics of movement in tennis, one of the first things to do is to understand the movement patterns of the sport, specifically how these patterns relate to different tennis shoes. Once these patterns are understood, footwear company can design tennis shoes that match the individual needs of tennis players. Plantar pressure measurement is widely employed to study foot function, the mechanical pathogenesis for foot disease and as a diagnostic and outcome measurement tool for many performance. Measurements were taken of plantar pressure distribution across the foot and using F-Scan(Tekscan Inc.) systems respectively. The F-Scan system for dynamic in-shoe foot pressure measurements has enabled us to assess quantitatively the efficacy of different types of footwear in reducing foot pressures. The Tekscan F-Scan system consists of a flexible, 0.18mm thick sole-shape having 1260 pressure sensors, the sensor insole was trimmed to fit the subjects' right, left shoes. For this study 4 university male, high level tennis players were instructed to hit alternated forehand stroke, backhand stroke, forehand volley, backhand volley, smash, service movement in 4 different tennis shoes. 1. When impact in tennis movement, peak pressure distribution of landing foot displayed D>C>B>A, A displayed the best low pressure distribution. A style's tennis shoes will suggest prayer with high impact. If prayer with high impact feeling during pray in tennis wear A style, it will decrease injury, will have performance improvement. 2. When impact in tennis movement, plantar pattern of pressure distribution in landing foot displayed B>A>C>D in stability performance. During tennis, prayer want to stability movement suggest B style tennis shoes when tennis movement impact keep stability of human body. B style tennis shoes give performance improvement 3. When impact in tennis movement, plantar pattern of center of force(C.O.F.)trajectory in landing foot analyzed this : 1) When stroke movement and volley movement in tennis, prayer better to rearfoot movement. 2) when service movement, prayer midfoot strike movement. 3) when smash movement, prayer have forefoot strike movement.