• Title/Summary/Keyword: shock wave

Search Result 982, Processing Time 0.025 seconds

A Study of the Plume-Induced Shock Wave on Supersonic Afterbodies (초음속 동체후미부에서 발생하는 Plume-Induced Shock Wave에 관한 연구)

  • Lee Young-Ki;Kim Heuy-Dong;Raghunathan Srinivasan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.399-402
    • /
    • 2005
  • The present numerical study describes the flow physics on the interaction between the supersonic freestream and jet plume. The compressible flow past a simplified afterbody model with a sonic nozzle is investigated using mass-averaged Navier-Stokes equations, discretized by a fully implicit finite volume scheme, and the standard $k-{\omega}$ turbulence model. The results obtained through the present study are discussed specifically regarding the effect of the plume pressure ratio, freestream Mach number and base dimensions on the location of the plume-induced shock wave generated on the afterbody by the underexpansion of the jet plume.

  • PDF

Extracorporeal Shock Wave Therapy for the Treatment of Refractory Plantar Fasciitis (난치성 족저 근막염의 체외충격파를 이용한 치료)

  • Choi, Woo-Jin;Lee, Jin-Woo;Kwak, Yoon-Hae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 2007
  • Purpose: The objective of this study was to report the outcomes of patients treated with extracorporeal shock wave therapy (ESWT) for refractory plantar fasciitis of the foot. Materials and Methods: From November 2005 to October 2006, a total of sixty-two patients with refractory plantar fasciitis were treated with extracorporeal shock wave therapy. The main outcome measurements were visual analogue scale (VAS) and Roles and Maudsley score evaluated before treatment and at one and six months after treatment. Results: Roles and Maudsley score was excellent (0%), good (6.4%), fair (35.4%) and poor (58.2%) before treatment which improved to excellent (56.5%), good (38.7%), fair (4.8%) and poor (0%) at final follow-up. VAS scores also significantly improved after ESWT (p<0.05). There was no statistically significant correlation between clinical results and body mass index (BMI) (p=0.102). Conclusion: Extracorporeal shock wave therapy appears to be an effective and safe treatment modality for refractory plantar fasciitis and may help the patient to avoid surgery for refractory heel pain.

  • PDF

Removal of Pancreatic Calcification Stones by Extracorporeal Shock- Wave Lithotripsy under the Entangled Basket and the Endoscopy. (포획한 바스켓과 내시경이 얽힌 환자에서 체외충격파 쇄석술을 적용한 췌관결석의 치료 1예)

  • Son, S.Y.;Lee, W.H.;Lee, H.J.;Um, J.Y.;Chin, J.H.;Kim, K.C.
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.87-90
    • /
    • 1999
  • Treatment of human calculi by extracorporeal shock-wave lithotripsy(ESWL) was introduced for kidney stones in 1980. This technology was then applied to the treatment of bile duct stones and pancreatic stones. Some reports have also shown that disintegration of pancreatic stones by extracorporeal shock-wave lithotripsy is possible with successful subsequent endoscopic extraction of the fragments at home ana abroad. We tried removal of pancreatic calcification stones by endoscopic procedures, but could't be removed because the basket got entagled in the endoscopy. We report one case of this pancreatic calcification stones ; the stones were successfully fragmented and completely removal by extracorporeal shock-wave lithotripsy.

  • PDF

A Study on the Detection of Small Arm Rifle Sound Using the Signal Modelling Method (신호 모델링 기법을 이용한 소총화기 신호 검출에 대한 연구)

  • Shin, Mincheol;Park, Kyusik
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.7
    • /
    • pp.443-451
    • /
    • 2015
  • This paper proposes a signal modelling method that can effectively detect the shock wave(SW) sound and muzzle blast(MB) sound from the gunshot of a small arm rifle. In order to localize a counter sniper in battlefield, an accurate detection of both shock wave sound and muzzle blast sound are the necessary keys in estimating the direction and the distance of the counter sniper. To verify the performance of the proposed algorithm, a real gunshot sound in a domestic military shooting range was recorded and analyzed. From the experimental results, the proposed signal modelling method was found to be superior to the comparative system more than 20% in a shock wave detection and 5% in a muzzle blast detection, respectively.

Innovative Modeling of Explosive Shock Wave Assisted Drug Delivery (고에너지물질에 의한 약물 전달 시스템 연구)

  • Yoh, Jai-Ick;Kim, Ki-Hong;Lee, Kyung-Cheol;Lee, Hyun-Hee;Park, Kyoung-Jin
    • Journal of the Korean Society of Combustion
    • /
    • v.11 no.4
    • /
    • pp.9-13
    • /
    • 2006
  • Recent advances in energetic materials modeling and high-resolution hydrocode simulation enable enhanced computational analysis of bio-medical treatments that utilize high-pressure shock waves. Of particular interest is in designing devices that use such technology in medical treatments. For example, the generated micro shock waves with peak pressure on orders of 10 GPa can be used for treatments such as kidney stone removal, transdermal micro-particle delivery, and cancer cell removal. In this work, we present a new computational methodology for applying the high explosive dynamics to bio-medical treatments by making use of high pressure shock physics and multi-material wave interactions. The preliminary calculations conducted by the in-house code, GIBBS2D, captures various features that are observed from the actual experiments under the similar test conditions. We expect to gain novel insights in applying explosive shock wave physics to the bio-medical science involving drug injection. Our forthcoming papers will illustrate the quantitative comparison of the modeled results against the experimental data.

  • PDF

Planar Shock Wave Compaction of Oxidized Copper Nano Powders using High Speed Collision and Its Mechanical Properties (고속 충돌 시 발생하는 평면 충격파를 이용한 산화 나노 분말의 치밀화 및 기계적 특성 평가)

  • Ahn, Dong-Hyun;Kim, Wooyeol;Park, Lee Ju;Kim, Hyoung Seop
    • Journal of Powder Materials
    • /
    • v.21 no.1
    • /
    • pp.39-43
    • /
    • 2014
  • Bulk nanostructured copper was fabricated by a shock compaction method using the planar shock wave generated by a single gas gun system. Nano sized powders, average diameter of 100 nm, were compacted into the capsule and target die, which were designed to eliminate the effect of undesired shock wave, and then impacted with an aluminum alloy target at 400 m/s. Microstructure and mechanical properties of the shock compact specimen were analyzed using an optical microscope (OM), scanning electron microscope (SEM), and micro indentation. Hardness results showed low values (approximately 45~80 Hv) similar or slightly higher than those of conventional coarse grained commercial purity copper. This result indicates the poor quality of bonding between particles. Images from OM and SEM also confirmed that no strong bonding was achieved between them due to the insufficient energy and surface oxygen layer of the powders.

Development of Multi-channel Simultaneous Laser Shock Sensing System for Linear Explosive-induced Pyroshock Propagation Prediction (선형화약 파이로 충격파 전파 예측을 위한 다채널 동시 레이저 충격파 센싱 시스템 개발)

  • Jang, Jae Kyeong;Abbas, Haider;Lee, Jung Ruyl
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.5
    • /
    • pp.46-51
    • /
    • 2015
  • Multi-channel DAQ system was developed to predict propagation characteristic of the shock wave generated by linear explosive. The system can generate shock wave from 1000 points per second using a pulsed laser and simultaneously obtain the shock wave signals using 15 chanel contact sensor. The system is expected to pridict the propagation characteristics of various linear explosive-induced pyroshock because it can be used with a user-defined time delay that corresponds to detonation speed of the linear explosive.

Innovative Modeling of Explosive Shock Wave Assisted Drug Delivery (고에너지물질에 의한 약물 전달 시스템 연구)

  • Yoh, Jai-Ick;Kim, Ki-Hong;Lee, Kyung-Cheol;Lee, Hyun-Hee;Park, Kyoung-Jin
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.213-217
    • /
    • 2006
  • Recent advances in energetic materials modeling and high-resolution hydrocode simulation enable enhanced computational analysis of bio-medical treatments that utilize high-pressure shock waves. Of particular interest is in designing devices that use such technology in medical treatments. For example, the generated micro shock waves with peak pressure on orders of 10 GPa can be used for treatments such as kidney stone removal, trans-dermal micro-particle delivery. and cancer cell removal. In this work, we present a new computational methodology for applying the high explosive dynamics to bio-medical treatments by making use of high pressure shock physics and multi-material wave interactions. The preliminary calculations conducted by the in-house code, GIBBS2D, captures various features that are observed from the actual experiments under the similar test conditions. We expect to gain novel insights in applying explosive shock wave physics to the bio-medical science involving drug injection. Our forthcoming papers will illustrate the quantitative comparison of the modeled results against the experimental data.

  • PDF

Shock Compression of Metal using High Energy Laser and Innovative Applications (고 에너지를 이용한 충격파 발생과 응용)

  • Lee, Hyun-Hee;Yoh, Jai-Ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.353-357
    • /
    • 2007
  • We have been setting up experiments on propagation of shock waves generated by the pulsed laser ablation. One side of a thin metal foil is subjected to laser ablation as a shock wave propagates through the foil. The shock wave, which penetrates through the foil is reflected by an acoustic impedance which causes the metal foil to high-strain rate deform. This short time physics is captured on an ICCD camera. The focus of our research is applying shock wave and deformation of the thin foil from the ablation to accelerating micro-particles to a very high speed.

  • PDF

Evaluation of Thermal Shock Damage of Metal Matrix Composite Using Ultasonics (초음파를 이용한 금속기지 복합재료의 열충격 손상 평가)

  • Kang, Moon-Phil;Lee, Min-Rae;Lee, Joon-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.11 s.242
    • /
    • pp.1480-1487
    • /
    • 2005
  • Metal matrix composites(MMCs) have been rapidly becoming one of the strongest candidates for structural materials fur many high temperature application. However, among the various high temperature environments in which metal matrix composites was applied, thermal shock is known to cause significant degradation in most MMC system. Due to the appreciable difference in coefficient of thermal expansion(CTE) between reinforcement and metal matrix, internal stresses are generated following temperature changes. Infernal stresses affect degradation of mechanical properties of MMC by causing microscopic damage in interface and matrix during thermal cycling. Therefore, the nondestructive evaluation on thermal shock damage behavior of SiC/A16061 composite has been carried out using ultrasonics. For this study, SiC fiber reinforced metal matrix composite specimens fabricated by a squeeze casting technique were thermally cycled in the temperature range 298$\~$673 K up to 1000cyc1es. Three point bending test was conducted to investigate the efffct of thermal shock damage on mechanical properties. The relationship between thermal shock damage behavior and the propagation characteristics of surface wave and SH-ultrasonic wave was discussed by considering the result of SEM observation of fracture surface.