• 제목/요약/키워드: shift parameter

검색결과 209건 처리시간 0.027초

Current Sharing Method Based on Optimal Phase Shift Control for Interleaved Three-Phase Half Bridge LLC Converter with Floating Y-Connection

  • Shi, Lin;Liu, Bangyin;Duan, Shanxu
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.934-943
    • /
    • 2019
  • A current balance problem exists in multi-phase LLC converters due to the resonant parameter tolerance. This paper presents a current balancing method for interleaved three-phase half bridge LLC converters. This method regulates the phase shift angle of the driving signals between the three phases based on a converter with a floating Y-connection. The floating midpoint voltage has different influences on each phase current and makes the three-phase current balance performance better than midpoint non-floating systems. Phase shift control between modules can further regulate the midpoint voltage. Then three phase current sharing is realized without adding extra components. The current distributions in a midpoint non-floating system and a midpoint floating system are compared. Then the principle and implementation of the proposed control strategy are analyzed in detail. A 3kW prototype is built to verify the validity and feasibility of the proposed method.

통합 수증기 개질 시스템의 작동 조건에 대한 수치적 연구 (Parametric Study of an Integrated Steam Methane Reformer with Top-Fired Combustor)

  • 노정훈;정혜미;김동희;엄석기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.156.1-156.1
    • /
    • 2011
  • It is of great importance to predict operating parameter characteristics of an integrated fuel processor by the increased life-time and system performance. In this study, computational analysis is performed to gain fundamental insights on transport phenomena and chemical reactions in reformer which consists of preheating, steam reforming, and water gas shift reaction beds. Also, a top-fired burner locates inside of the reforming system. The combustor is providing thermal energy necessary for the steam reforming bed which is a endothermic catalytic reactor. Two-dimensional numerical model of the integrated fuel processing system is introduced for the analysis of heat and mass transport phenomena as well as surface kinetics and catalytic process. A kinetic model was developed and then computational results were compared with the experimental data available in the literature. Subsequently, parameter study using the validated steam methane reforming model was conducted by considering operating parameters, i.e. steam to carbon ratio and temperature.

  • PDF

생산설비의 유지보수서비스와 제품의 불량률을 고려한 최적 생산주기 연구 (Determining an Optimal Production Time for EPQ Model with Preventive Maintenance and Defective Rate)

  • 김미경;박민재
    • 품질경영학회지
    • /
    • 제47권1호
    • /
    • pp.87-96
    • /
    • 2019
  • Purpose: The purpose of this paper is to determine an optimal production time for economic production quantity model with preventive maintenance and random defective rate as the function of a machinery deteriorates. Methods: If a machinery shifts from "in-control" state to "out-of-control" state, a proportion of defective items being produced increases. It is assumed that time to state shift is a random variable and follows an arbitrary distribution. The elapsed time until process shift decreases stochastically as a production cycle repeats and quasi-renewal process is used to implement for production facilities to deteriorate. Results: When the exponential parameter for exponential distribution increases, the optimal production time increases. When Weibull distribution is considered, the optimal production time is closely affected by the shape parameter of Weibull distribution. Conclusion: A mathematical model is suggested to find optimal production time and optimal number of production cycles and numerical examples are implemented to validate the patterns for changes of optimal times under different parameters assumptions. The real application is implemented using the proposed approach.

질량 추정기 기반 수동 변속 상용차용 요 모멘트 제어 알고리즘 (Yaw Moment Control Algorithm based on Estimated Vehicle Mass for Manual-Shift Commercial Vehicles)

  • 김자유;차현수;박관우;이경수
    • 자동차안전학회지
    • /
    • 제14권2호
    • /
    • pp.7-13
    • /
    • 2022
  • This paper presents a yaw moment control based on estimated mass for manual-shift commercial vehicles. In yaw moment controller, parameter uncertantiy of vehicle mass is important because the desired yaw moment depends on vehicle parameter. However, in the case of commercial vehicle, the weight of the loaded vehicle is more than twice as much as compared to the unloaded vehicle. The proposed algorithm estimates the vehicle mass by using the longitudinal dynamic and gear shifting characteristics. The estimated mass is used to adaptively modify the vehicle parameters. In addition, this paper estimates the chamber pressure of a pneumatic brake and generates the target yaw moment through on/off valve control. MATLAB/Simulink and Trucksim were performed under sine with dwell test. The results demonstrate that the proposed algorithm improves the lateral and rollover stability.

Lateral Symmetry of Center of Pressure During Walking in Patients With Unilateral Knee Osteoarthritis

  • Kim, Si-hyun;Park, Kyue-nam
    • 한국전문물리치료학회지
    • /
    • 제28권1호
    • /
    • pp.77-83
    • /
    • 2021
  • Background: Although symmetry of spatio-temporal parameter and center of pressure (COP) shift during walking is associated with knee adduction moment, research on clinical association with knee osteoarthritis (OA)-related knee pain and functional scores is lacking. Objects: The aims were 1) to compare symmetry of gait parameters and COP-shift in patients with unilateral knee OA and pain and matched controls, and 2) to investigate the relationship between symmetry of gait parameters and COP-shift, and clinical measures. Methods: Female subjects (n = 16) had with unilateral radiological knee OA and pain. Healthy controls (n = 15) were age-matched to OA group. Symmetry of foot rotation, step length, stance and swing phase, lateral symmetry of COP and anterior/posterior symmetry of COP during walking was assessed. To assess the clinical variables, pain intensity, pain duration and function using Knee Osteoarthritis Outcome Survey (KOOS) subscales were collected. We compared symmetry between groups using Mann-Whitney U-test or independent t-test. Relationships between clinical measures and symmetry index measured using Spearman's correlation test. Statistical significance was set at α = 0.05. Results: Knee OA group showed significantly greater values of only lateral symmetry of COP (p < 0.01) than healthy group. Values of lateral symmetry of COP had moderate or strong correlation significantly with the intensity of knee pain, pain duration, and scores of all KOOS subscales (p < 0.01). Conclusion: Patients with unilateral knee OA and pain showed more asymmetry of lateral COP-shift during walking compared with matched healthy controls. In addition, larger asymmetry of lateral COP-shift has the moderate or strong association with worse of knee pain, worse in KOOS scores and longer duration of knee pain. Asymmetry of lateral COP-shift during walking may be one of the characteristics of unilateral knee OA as the compensatory strategy response to unilateral OA of the knee.

유도전동기의 파라메터 추정에 관한 연구 (A Study on Estimation of Induction Motor Parameter)

  • 이정민;조지원;강웅석;최규하;김한성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.623-626
    • /
    • 1991
  • Crucial to the success of the vector control scheme without speed sensor is up to computing instantaneous position of the rotor flux. In tracing this flux depending on the machine parameter, variations of those factor lead to the non-linear charlcteristic between I/O value and decrease overall efficiency of the vector control scheme. This paper, using recursive least square method estimating instantaneous value of the machine speed and parameter from the shift of current and voltage, proposes an algorithm for compensating the I/O error of the scheme.

  • PDF

DC/DC 컨버터의 파라미터 변화를 고려한 구간분석법 기반 제어기 설계 (Interval-based Controller Design Considering Parameter Variations for DC/DC Converters)

  • 최성진
    • 제어로봇시스템학회논문지
    • /
    • 제19권10호
    • /
    • pp.879-885
    • /
    • 2013
  • By performing interval analysis on the system transfer function, we propose an improved method of control loop design for a DC/DC converter. In conventional design methods, the effect of system parameter change due to the specified range of operating conditions and production tolerances in power components should be checked a posteriori, because this may result in a transfer function shift and performance degradation. In the proposed method, a possible parameter change is considered a priori in the design step in order that the desired crossover frequency and sufficient phase margin can be achieved even in the worst case condition. As an illustrative example, a buck dc/dc converter is designed by two different methods and performance comparisons are performed to verify the feasibility of the proposed scheme.

Water balance change at a transiting subtropical forest in Jeju Island

  • Kim, JiHyun;Jo, Kyungwoo;Kim, Jeongbin;Hong, Jinkyu;Jo, Sungsoo;Chun, Jung Hwa;Park, Chanwoo;Kim, Yeonjoo
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.99-99
    • /
    • 2022
  • Jeju island has a humid subtropical climate and this climate zone is expected to migrate northward toward the main land, Korea Peninsula, as temperature increases are accelerated. Vegetation type has been inevitably shifted along with the climatic change, having more subtropical species native in southeast Asia or even in Africa. With the forest composition shift, it becomes more important than ever to analyze the water balance of the forest wihth the ongoing as well as upcoming climate change. Here, we implemented the Ecosystem Demography Biosphere Model (ED2) by initializing the key variables using forest inventory data (diameter at breast height in 2012). Out of 10,000 parameter sets randomly generated from prior distribution distributions of each parameter (i.e., Monte-Carlo Method), we selected four behavioral parameter sets using remote-sensing data (LAI-MOD15A2H, GPP-MOD17A2H, and ET-MOD16A2, 8-days at 500-m during 2001-2005), and evaluated the performances using eddy-covariance carbon flux data (2012 Mar.-Sep. 30-min) and remote sensing data between 2006-2020. We simulated each of the four RCP scenarios (2.6, 4.5, 6.0, and 8.5) from four climate forcings (GFDL-ESM2M, HadGEM2-ES, IPSL-CM5A-LR, and MIROC5 from ISIMIP2b). Based on those 64 simulation sets, we estimate the changes in water balance resulting from the forest composition shift, and also uncertainty in the estimates and the sensitivity of the estimates to the parameters, climate forcings, and RCP scenarios.

  • PDF

Review on the Determination of Frumkin, Langmuir, and Temkin Adsorption Isotherms at Electrode/Solution Interfaces Using the Phase-Shift Method and Correlation Constants

  • Chun, Jinyoung;Chun, Jang H.
    • Korean Chemical Engineering Research
    • /
    • 제54권6호
    • /
    • pp.734-745
    • /
    • 2016
  • This review article described the electrochemical Frumkin, Langmuir, and Temkin adsorption isotherms of over-potentially deposited hydrogen (OPD H) and deuterium (OPD D) for the cathodic $H_2$ and $D_2$ evolution reactions (HER, DER) at Pt, Ir, Pt-Ir alloy, Pd, Au, and Re/normal ($H_2O$) and heavy water ($D_2O$) solution interfaces. The Frumkin, Langmuir, and Temkin adsorption isotherms of intermediates (OPD H, OPD D, etc.) for sequential reactions (HER, DER, etc.) at electrode/solution interfaces are determined using the phase-shift method and correlation constants, which have been suggested and developed by Chun et al. The basic procedure of the phase-shift method, the Frumkin, Langmuir, and Temkin adsorption isotherms of OPD H and OPD D and related electrode kinetic and thermodynamic parameters, i.e., the fractional surface coverage ($0{\leq}{\theta}{\leq}1$) vs. potential (E) behavior (${\theta}$ vs. E), equilibrium constant (K), interaction parameter (g), standard Gibbs energy (${\Delta}G_{\theta}{^{\circ}}$) of adsorption, and rate (r) of change of ${\Delta}G_{\theta}{^{\circ}}$ with ${\theta}$ ($0{\leq}{\theta}{\leq}1$), at the interfaces are briefly interpreted and summarized. The phase-shift method and correlation constants are useful and effective techniques to determine the Frumkin, Langmuir, and Temkin adsorption isotherms and related electrode kinetic and thermodynamic parameters (${\theta}$ vs. E, K, g, ${\Delta}G_{\theta}{^{\circ}}$, r) at electrode/solution interfaces.

Measurement of electron density of atmospheric pressure Ne plasma jet by laser heterodyne Interferometer with voltage

  • Lim, Jun Sup;Hong, Young June;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.140.1-140.1
    • /
    • 2015
  • Currently, As Plasma application is expanded to the industrial and medical industrial, Low temperature plasma characteristics became important. Especially in Medical industrial, Low temperature plasma directly adapted to human skin, so their plasma parameter is important. One of the plasma parameters is electron density, some kinds of method to measuring electron density are Thomson scattering spectroscopy and Millimeter-wave transmission measurement. But most methods is expensive to composed of experiment system. Heterodyne interferometer system is cheap and simple to setting up, So we tried to measuring electron density by Laser heterodyne interferometer. To measuring electron density at atmospheric pressure, we need to obtain the phase shift signal. And we use a heterodyne interferometer. Our guiding laser is Helium-Neon laser which generated 632 nm laser. We set up to chopper which can make a laser signal like a pulse. Chopper can make a 4 kHz chopping. We used Needle jet as Ne plasma sources. Interference pattern is changed by refractive index of electron density. As this refractive index change, phase shift was occurred. Electron density is changed from Townsend discharge's electron bombardment, so we observed phenomena and calculated phase shift. Finally, we measured electron density by refractive index and electron density relationship. The calculated electron density value is approximately 1015~1016 cm-3. And we studied electron density value with voltage.

  • PDF