• 제목/요약/키워드: shielding rate

검색결과 264건 처리시간 0.019초

니켈나노파우더 함침기법을 이용한 탄소복합소재의 전자파차폐 효과에 관한 연구 (Carbon Composite Material Using Nickel Nano-Powder Impregnation Research on Electromagnetic Shielding Effect)

  • 서광수;곽이구
    • 한국기계가공학회지
    • /
    • 제19권12호
    • /
    • pp.49-55
    • /
    • 2020
  • In order to improve the electromagnetic shielding rate of Carbon Fiber (CF), it was produced using the nickel nano-powder impregnating method. Using two types of nickel powder having thicknesses of 50 ㎛ and 100 ㎛, and a thermoplastic elastomer resin, a compound containing 10-20% nickel content was mixed and then manufactured through an extruder. The CF coated with the compound was woven and manufactured using a 1-ply specimen. The final nickel content of the specimen was verified using TGA and the distribution of nickel powder on the CF surface was verified using SEM. The metal shows a high shielding rate in the low-frequency band, but the shielding rate decreases at higher-frequency bands. The CF improves at the higher frequency band, and metals reflect electromagnetic waves while carbon absorbs electromagnetic waves. The study of shielding materials, which are stronger and lighter than metal, by using CF lighter than metal and enabling the shielding rate from low-frequency band to high-frequency band, confirmed that the larger the area coated with nickel nano-powder, the better the electromagnetic shielding performance. In particular, CF coated with a thickness of 100 ㎛ has a shielding rate similar to that of copper and can also be used for EV/HEV automotive cables and other applications in the future.

방사선방어 앞치마 성능 평가 (Performance Evaluation of Radiation Protection Apron's)

  • 강종구;강병삼
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권5호
    • /
    • pp.373-377
    • /
    • 2019
  • Radiation exposure is on the rise as the working hours of radiation workers increase. Accordingly, the importance of protection products for decreasing the dose of exposure has risen, and excellent X-ray shielding ability and light weight are required. The purpose of this study is to compare the Pb which use currently and other elements in order to reduce the exposure of workers to the most effective protection products. For experiment, we used the general X-ray equipment and angiography equipment, and obtained the Pb and apron's shielding rate. When the shielding rate of Pb and apron was compared in general X-ray equipment, the shielding rate was 95.1% for Pb 0.5 mm, 96.1% for apron 0.5 mmPb and 95.6% for Bi+W 0.5 mmPb. When compared the shielding rate of each aprons in angiography equipment, 0.5 mmPb apron was the highest as 96.4% and Bi+W 0.25 mmPb apron was the lowest as 90.2% at the 50 cm distance. The shielding rate of 0.5 mmPb apron was the highest as 95.7% and Bi+W 0.25 mmPb apron was the lowest as 85.9% at the 100 cm distance. As a result of evaluating the apron efficiency through this study, 0.5 mmPb apron showed the best shielding rate, but it was the heaviest apron. 0.35 mmPb apron and Bi+W 0.25 mmPb apron weighed light but had low shielding rate. Through the results of this experiment, it is recommended that radiation workers reduce radiation exposure by using more efficient protection products.

붕규산유리 및 비정질 붕소강 섬유를 혼입한 콘크리트의 역학적 성능 및 중성자 차폐성능 평가 (Mechanical Properties and Neutron Shielding Rate of Concrete with Borosilicate-Glasses and Amorphous Boron Steel Fiber)

  • 이준철
    • 한국건설순환자원학회논문집
    • /
    • 제4권3호
    • /
    • pp.269-275
    • /
    • 2016
  • 본 연구에서는 붕규산 유리와 비정질 붕소강 섬유를 혼입한 콘크리트의 역학적 성능 및 중성자 차폐성능을 평가하였다. 잔골재를 붕규산 유리로 치환한 콘크리트와 비정질 붕소강 섬유를 보강한 콘크리트를 제조하여 압축강도, 정탄성계수, 압축인성, 휨강도, 휨인성, 중성자 차폐성능을 평가하였다. 실험결과, Plain 콘크리트와 대비하여 붕규산 유리를 혼입한 콘크리트의 경우 압축강도 및 휨강도는 저하되었으나, 중성자 차폐성능은 향상되는 것으로 나타났다. 비정질 붕소강 섬유를 혼입한 콘크리트의 경우 Plain 콘크리트와 대비하여 압축인성 및 휨인성이 증진되었으며 중성자 차폐성능도 향상되는 것으로 나타났다.

99mTc의 에너지 스펙트럼 변화에 따른 납 앞치마의 차폐 효과 평가 (Evaluation of the Shielding Effect of Lead Apron according to the Energy Spectrum Change of 99mTc)

  • 윤창용;지영식
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.889-896
    • /
    • 2023
  • 핵의학과에서 가장 많이 사용되는 99mTc를 점선원과 산란팬텀을 이용하여 에너지스펙트럼 변화를 분석하고 변화된 감마선 에너지에 따른 납 앞치마의 차폐효과를 평가하였다. 산란팬텀의 감마선 에너지 스펙트럼은 점선원보다 광전피크 영역은 감소하고 컴프턴 산란영역은 증가하였다. 감마선원 형태 변화에 따른 에너지 영역별 계수치는 점선원의 계수치보다 20 cm 거리에서 최대 66.1 %의 감소율을 보였으며 컴프턴 산란 영역에서는 산란팬텀의의 계수치가 점선원의 계수치보다 최대 40 cm 거리에서 122.2 % 증가하는 결과를 보였다. 감마카메라를 이용한 선원과 산란팬텀의 거리에 따른 차폐율 차이에서 광전피크 영역은 유사한 결과를 보였으나 컴프턴 산란영역에서는 20 cm거리에서 산란팬텀의 차폐율이 점선원의 차폐율보다 29.2% 증가하였으며 거리가 증가함에 따라 차폐율 차이는 감소하였다. 방사선 선량계를 이용한 납 앞치마 차폐율 측정에서 산란팬텀의 차폐율은 최대 15.3 %의 차이를 보였으며 거리가 증가할수록 두 선원의 차폐율 차이는 감소하였다. 산란팬텀의 납 앞치마 차폐율이 점선원보다 높고 선원과 가까운 거리일수록 납 앞치마의 효과는 증가하는 결과로 방사성의약품을 주입한 환자를 직접 대면할 때 납 앞치마의 착용은 방사선피폭 저감화에 도움이 될 것으로 판단된다.

일반촬영분야에서의 3D 프린터로 제작한 텅스텐 혼합 필라멘트 차폐체의 성능평가 (Evaluation of Tungsten Blended Filament Shields Made by 3D Printer in Radiography)

  • 윤준;윤명성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.615-621
    • /
    • 2021
  • In the medical field, radiation provides information for the diagnosis and treatment of diseases. As the use of radiation increases and the risk of exposure increases, interest in radiation protection is also rapidly increasing. Lead shielding material is mainly used, which has a risk of lead poisoning and absorption into the body. Tungsten mixed filament shielding sheets were fabricated with a size of 70 × 70 mm and a thickness of 1, 2, and 4 mm by using a 3D printer. In the general shooting experiment, the thickness of the shielding sheet is 1 ~ 5mm, the tube voltage is 60, 80, 100, 120 kVp and the tube current is 20, 40 mAs. In general photography, Tungsten showed better shielding rate compared to Brass, Copper, and Lead protective tools under all irradiation conditions, and in particular, Tungsten 5 mm showed 100% shielding rate. The 3D-printed tungsten mixed filament shielding is expected to be used as a new shield that can replace the existing lead protection tools as it shows a better shielding rate than the existing lead protection tools in Radiography.

Zn-Al 아크 금속용사 피막을 적용한 구리분말 혼입 시멘트 모르타르의 전자파 차폐 성능 평가 (The Shielding Effectiveness of Zn-Al Arc Thermal Metal Film Coated Cement-Mortar Using Copper Powder)

  • 최현준;최현국;김형철;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.124-125
    • /
    • 2017
  • In this study, the shielding effectiveness of the Zn-Al arc thermal metal film coated cement-mortar mixed with copper powder by reflection, absorption, multi-reflection loss in 2.25~2.65 GHz was reviewed. By enhancing the mixing ratio of copper powder, the shielding effectiveness by absorption and multi-reflection loss was increased, but shielding rate(%) based on 80 dB showed below 20%. The Zn-Al arc thermal metal film coated on specimen, the shielding rate increased 3.5 times by reflection loss.

  • PDF

몬테칼로 방법을 이용한 방사성 불소에 대한 L-블럭형 방호장비의 차폐율 및 공간의 선량분포 계산 (Calculation of Shielding Rate and Dose Distribution of Space of L-Block-Type Protective Equipment for Radioactive Fluorine using the Monte Carlo Method)

  • 한동현
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.813-819
    • /
    • 2021
  • 본 연구에서는 방사성 불소의 인체 내 주입 시 방사선 방호목적으로 사용되는 L-블럭형 방호장비의 차폐율과 주변공간의 선량분포를 몬테칼로 방법을 이용해 계산하였다. L-블럭형 차폐장치의 몸체 및 윈도우 부위의 차폐율은 99.99 %였다. 1 m거리에서 계산한 선량분포는 XZ평면의 135°, 45°, 225°, 315°, 180°에서 상대적으로 높게 나타났고, 0°, 90°, 270°에서는 매우 낮게 계산되었다. YZ평면에서는 135°, 180°, 225°에서 상대적으로 높게 나타났고, 나머지 각도에서는 매우 낮게 계산되었다. AZ와 BZ 평면에서도 YZ평면과 유사한 결과를 나타냈다. 또한 선원의 수평방향과 선원의 상방 45°방향의 선량분포를 통해 225°~315°범위에서 차폐율이 가장 우수함을 확인하였다. 이와 같은 결과가 방사선 작업 종사자들의 방사선 방호에 필요한 기초자료로 활용되기를 기대한다.

Brain CT검사 시 3D프린터 필라멘트에 따른 수정체 차폐 연구 (A Study on the Shielding of Orbit by 3D Printed Filament in Brain CT)

  • 최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.101-108
    • /
    • 2021
  • CT는 인체 내 장기의 해부학적 구조를 정확하게 나타낼 수 있으며, 영상의 분해능이 우수하다. Brain CT 검사 시 수정체의 방사선 감수성이 높아서 피폭의 영향을 많이 받는다. 본 연구는 수정체에 피폭선량을 감소하기 위해 비스무스와 텅스텐 필라멘트 차폐물질을 사용하여 Non-shield와 Shield에 대한 피폭선량의 변화와 차폐율을 비교 하고자 한다. 본 연구에서는 3D printing으로 제작한 비스무스, 텅스텐 필라멘트 차폐물질을 사용하여, 차폐물질 두께와 slice에 따라 피폭되는 선량을 측정하였다. 헤드팬텀을 고정시켜 안구에 Magicmax universal 선량계를 위치시켜 차폐 물질을 놓지 않았을 경우와 그 위에 차폐 물질을 놓았을 때 차폐율을 각각 비교하기 위해 두 물질을 1mm ~ 5mm 두께로 각각 측정하였다. 1 mm 두께의 필라멘트에서 비스무스 필라멘트는 26.8 %, 텅스텐 필라멘트는 43.1 % 차폐율이 나타났다. 따라서 비스무스 필라멘트보다 텅스텐 필라멘트에서 더 큰 차폐효과가 나타났다. 차폐체의 종류, 두께, 슬라이스 간격에 따라 선량을 측정한 결과, 비스무스 필라멘트 보다 텅스텐 필라멘트가 더 큰 차폐효과가 나타났다.

비스무스, 텅스텐 기반 차폐체의 성능 및 유용성 평가 (The Evaluation of Performance and Usability of Bismuth, Tungsten Based Shields)

  • 박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.611-616
    • /
    • 2018
  • Lead apron is harmful to the human body because it is made at heavy metals, and when worn for long periods of time, it causes pain. Therefore, this paper intended to improve the defects of lead apron by using new material shields. For the comparative evaluation of lead and new material shieldes, the shielding rate and weight were measured and tested based on lead 0.5 mmPb. The rate of shielding was 97% based on lead at 0.5 mm thickness, while The new material shield T3 showed similar shielding rates as lead in 8 layers, and in T2 these values were measured in 11 layers. In addition, similar shielding rate was measured in 12 layers at B2, and 8 layers in BF, and 4 layers in $BF_2$. Comparing the weight of cases when commercialized with apron, T3, T2 and B2 were heavier than lead apron. But BF, $BF_2$ were lighter than the lead apron. Based on the results of the experiment, T3 and T2 can be used as an alternative to lead if human or environmental hazards are considered a priority. However, BF and $BF_2$ should be used if the reduction of external exposure is considered a priority.

X선 및 감마선에 대한 apron의 차폐율 측정 (Measurement of Apron Shielding Rate for X-ray and Gamma-ray)

  • 박명환;권덕문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권3호
    • /
    • pp.245-250
    • /
    • 2007
  • 진단용 방사선발생장치에서의 X선 에너지와 $^{99m}Tc$-MDP, $^{18}F$-FDG의 감마선 에너지 대한 apron 0.25, 0.5 mmPb에 대한 차폐율을 측정하였다. X선 에너지는 관전압 $40{\sim}120\;kVp$ 범위 내에서 부가여과판 0, 2 mmAl을 사용 한 경우에 실효에너지가 $26.2{\sim}45.6\;keV$로 측정되었으며, 이때 apron 0.5 mmPb은 0.25 mmPb보다 최대 선질에서 5.5% 정도 차폐율이 증가하였다. 또한 두 종류의 apron은 직접선과 공간선량률에 대하여 90% 이상의 높은 차폐율을 나타내었다. 그리고 $^{99m}Tc$-MDP의 140 keV에서 0.25, 0.5 mmPb apron을 사용할 경우 $30{\sim}53%$ 정도의 차폐효과가 있었으며, $^{18}F$-FDG의 511 keV의 높은 에너지에서는 $1.3{\sim}3.6%$로 apron의 차폐효과가 매우 적었다.

  • PDF