• 제목/요약/키워드: shear wall buildings

검색결과 257건 처리시간 0.02초

표준 8절점 고체요소를 이용한 원전 격납건물 벽체요소의 비선형해석 (Nonlinear Analysis of Nuclear Containment Wall Element using Standard 8-node Solid Element)

  • 이홍표;전영선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.151-158
    • /
    • 2005
  • For the safety analysis of large structures such as nuclear containment buildings, we conventionally prefer to use analytical approach using finite element method rather than empirical test. Therefor, this paper is mainly focused to develop low-order solid finite element model with the elasto-plastic material model for the safety analysis of nuclear containment building. Drucker-Prager failure criteria in uncracked concrete and maximum tensile stress criteria in cracked concrete are used to model the constitutive behavior of concrete. The concrete material model takes into account the aspects of tensile strain, compression strength reduction of concrete and shear transfer to improve the accuracy of the finite element analysis. Finally, numerical simulation to compare the performance of the developed model with experimental results is employed. The numerical results in this study agree very well with the experimental data.

  • PDF

비정형 고층아파트에서의 구조체 분리 간격 (Structural Seperation of Unsymmetric Highrise Apartments)

  • 정하선;현창국;윤영호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1989년도 봄 학술발표회 논문집
    • /
    • pp.56-60
    • /
    • 1989
  • It is well known that the symmetric buildings have higher resistance than the unaymetric ones do under seismic load. However, it is sometimes inevitable to build an unsymmetric structure due to the site conditions or architectural needs. The unsymmetric building has structural disadvantages under seismic load. In such a case the structural seperation joints are often used to avoid those disadvantages. This paper presents a method to determine the width of the seperation joints for unsymmetric, reinforced concrete apartments structured by walls and slabs only. The variables of the study were the ratio of shear-wall stiffness to the building length in the same directron, the building height and the story mass.

  • PDF

The Structural Design of "China Zun" Tower, Beijing

  • Liu, Peng;Cheng, Yu;Zhu, Yan-Song
    • 국제초고층학회논문집
    • /
    • 제5권3호
    • /
    • pp.213-220
    • /
    • 2016
  • The "China Zun" tower in Beijing will rise to 528 meters in height and will be the tallest building in Beijing once built. Inspired by an ancient Chinese vessel, the "Zun", the plan dimensions reduce gradually from the bottom of the tower to the waist and then expand again as it rises to form an aesthetically beautiful and unique geometry. To satisfy the structural requirement for seismic and wind resistance, the structure is a dual system composed of a perimeter mega structure made of composite mega columns, mega braces, and belt trusses, and a reinforced-concrete core with steel plate-embedded walls. Advanced parametric design technology is applied to find the most efficient outer-perimeter structure system. The seismic design basically follows a mixed empirical and performance-based methodology that was verified by a shaking table test and other specimen lab tests. The tower is now half-way through its construction.

전단벽식 고층건물의 내진해석에 관한 연구 (A Study on the Improved Seismic Analysis of Multistory Shear Wall Buildings)

  • 이준교;이근홍;이수곤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.267-272
    • /
    • 1993
  • Currently about 60 contries in the world require earthquake resistant structural design in case of multistory building constructions. In these cases the equivalent lateral force procedure is commonly adopted because of its simplicity and convenience. This procedure, however, is developed based mainly on the first vibration mode response of building structure. The dynamic analysis of tall building shows that the effect of higher modes of vibration on the response of the building can not be neglected. In this paper, the effect of higher modes of vibration on seismic response is evaluated through modal analysis of tall building structures. On the basis of evaluation results, an improved procedure is to be proposed for the extended application of the equivalent lateral force procedure.

  • PDF

프리캐스트 대헝판 구조물의 접합부에 관한 탄소성해석 (Elasto-Plastic Analysis on Connections of Precast Large Panel Structures)

  • 권택진;박강근;권익노;조강표
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 봄 학술발표회논문집
    • /
    • pp.27-34
    • /
    • 1993
  • Precast large panel structures behave differently form frame and monolithic wall structures under external loads, because of the distinct planes of weakness in the horizontal and vertical joints between panels. These joints may slide and open during shaking, producing large localized changes in the bending and shear stiffness of individual walls. The structural behavior of large precast panel buildings depends on the relative strength and stiffness of the panels and joints. Special modeling are thus required for the analysis of precast panel connections. This study suggests a new analytical modeling and method to obtain the rational estimation of discontinuity and slip movements form the connections of precast large panel structures .

  • PDF

Lateral stability analysis of multistory buildings using the differential transform method

  • Aydin, Suleyman;Bozdogan, Kanat Burak
    • Structural Engineering and Mechanics
    • /
    • 제57권5호
    • /
    • pp.861-876
    • /
    • 2016
  • The determination of the critical buckling load of multistory structures is important since this load is used in second order analysis. It is more realistic to determine the critical buckling load of multistory structures using the whole system instead of independent elements. In this study, a method is proposed for designating the system critical buckling load of torsion-free structures of which the load-bearing system consists of frames and shear walls. In the method presented, the multistory structure is modeled in accordance with the continuous system calculation model and the differential equation governing the stability case is solved using the differential transform method (DTM). At the end of the study, an example problem is solved to show the conformity of the presented method with the finite elements method (FEM).

벽식 아파트 구조에서 연결부재의 거동특성 (The Behavior of Reinforced Concrete Coupling Elements in Wall-Dominant System)

  • 장극관;서대원;천영수
    • 콘크리트학회논문집
    • /
    • 제14권1호
    • /
    • pp.83-91
    • /
    • 2002
  • 현재 국내에서 건설되고 있는 대부분의 아파트는 철근콘크리트 전단벽과 연결부재만으로 구성된 순수벽식 구조형식을 취하고 있다. 그러나 이러한 벽식구조의 거동은 매우 복잡하며 연결부재의 영향을 크게 받는다. 따라서 본 연구에서는 부분구조체 실험을 통하여 국내 벽식구조의 연결부재, 즉 슬래브 및 연결보의 거동을 조사하고, 보강에 따른 효과를 검토하고자 하였다. 실험결과 1) 연결슬래브의 응력은 전폭에 걸쳐서 균일하지 않았고, 2) 벽체와 커플링 작용을 하는 연결슬래브의 유효 폭은 기존의 연구에서 제안한 값과 비교하여 큰 차이가 있는 것으로 나타났으며, 국내의 아파트구조에 적용하기에는 과대평가하는 경향이 있었다. 3) 또한 연결 보에서의 X자형 보강은 에너지소산 및 연성비 증가효과가 있는 것으로 나타났으며, 펀칭현상을 개선하여 안정된 이력거동을 확보하는데 효과적인 것으로 나타났다.

편심코어를 가지는 저층 철근콘크리트 필로티 건물의 내진성능 (Seismic Performance of Low-rise Piloti RC Buildings with Eccentric Core)

  • 김성용;김경남;윤태호
    • 한국산학기술학회논문지
    • /
    • 제21권10호
    • /
    • pp.490-498
    • /
    • 2020
  • 본 논문에서는 편심코아를 가지는 저층 필로티 건물의 내진거동을 해석하고 결과를 분석하였다. 본 논문에서는 저층 필로티 건물의 시공사례 중 KBC2005기준에 준하여 설계된 편심코어를 가지는 건물들의 설계자료를 수집하여, 대표적인 편심 필로티 건물을 프로토타입으로 선정하여 KDS41기준에 준하여 내진거동을 해석하고 결과를 분석하였다. 연구결과 편심코어를 가지는 필로티 건물의 경우 X방향은 소성거동, Y방향은 탄성거동을 하는 것으로 평가 되었다. 연구대상 건물의 층간 변위를 확인한 결과 최대변위 δ=67.51mm로 코어가 평면 중심에 위치하는 경우보다 층간 변위량이 더 큰 것으로 평가 되었다. 해석결과에서 층간 변위 비율은 법적 규준 이내인 것으로 평가되었다. 또한 변위 비율은 1층 필로티 구간이 2~4층 부분보다 확연히 높은 걸로 평가 되었으며, 저층 필로티 구조물의 경우 1층 라멘조 부분이 횡력에 취약한 것으로 평가되었다. 편심코어로 인하여 구조물 전체의 강성중심이 질량중심과 이격되어 있어 코어 반대쪽의 필로티 기둥에서 항복과 소성힌지 발생이 시작되므로 내진설계와 내진보강시 이에 대한 고려가 필요하다. 따라서, 편심코어를 가지는 저층 필로티 건물의 내진설계 및 내진보강시 필로티 구조의 횡변위 감소와 횡력저항능력을 보강할 필요가 있다.

조적벽체의 형상비에 따른 접착형 보강재의 보강효과에 관한 실험적 연구 (An Experimental Study for Reinforcement Effect of Adhesive Stiffeners Depending on the Aspect Ratio of Masonry Wall)

  • 박병태;권기혁
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권4호
    • /
    • pp.13-20
    • /
    • 2017
  • 비보강 조적조 건축물은 재료의 특성상 지진과 같은 횡력에 취약하지만, 국내에는 여전히 많은 조적조 건물이 존재한다. 특히 현재 남아있는 조적조 건축물의 대부분이 20년 이상 노후화됨에 따라 재해감소를 위한 경제성 있는 보강법의 개발이 요구된다. 본 논문에서는 이러한 노후 된 조적조 건축물의 보강법의 하나로 접착형 보강재를 활용한 조적벽체의 외부 보강법을 제시하였으며, 보강효과 검증을 위해 총 6개의 실험체를 형상비(L/H=1.0, 1.3, 2.0)를 변수로 제작하여 정적가력실험을 실시하였다. 실험결과, 보강전 후 조적벽체는 강체회전 및 미끄러짐에 의해 파괴가 발생하였고, 접착형 보강재 부착후 벽체의 최대내력, 최대변위, 소산에너지량은 증가하여 우수한 보강효과를 확인하였다. 또한 기존 유리섬유를 활용한 증가된 전단강도식에 착안하여 비보강 조적벽체에 대한 접착형 보강재의 설계안을 도출하여 적용을 위한 기초자료를 제공하였다.

강재판형 이력댐퍼 연결부재와 RC벽체의 접합상세에 따른 구조거동 (Structural Behavior of Joints between the Hysteretic Steel Damper Connector and RC Wall Depending on Connection Details)

  • 강인석;허무원
    • 콘크리트학회논문집
    • /
    • 제24권6호
    • /
    • pp.737-744
    • /
    • 2012
  • 강재형 댐퍼는 주로 철골구조에서 많이 사용되어 왔으나 최근에 들어 철근콘크리트 건물에도 사용빈도가 증가하는 추세이다. 철근콘크리트 건물에 강재이력댐퍼를 적용하기 위해서는 댐퍼의 접합부재가 댐퍼의 지지능력을 보 및 벽체로 전달하기에 적합한 강도와 강성을 지녀야만 한다. 하지만 균열로 인한 철근콘크리트 요소의 손상은 부득이한 것으로, 댐퍼로부터 지지부재로의 하중전달 메커니즘과 댐퍼 지지부재 이력특성의 규명은 이러한 댐퍼의 거동을 평가하는데 매우 중요하다. 이에 이 연구에서는 EaSy 댐퍼와 같은 강재판형 이력댐퍼의 지지부재와 RC벽체와의 접합상세를 대상으로 실험을 실시하였다. 실험 결과 전단과 관련된 균열의 양과 패턴을 제외하고는 모든 실험체의 파괴패턴은 거의 동일한 것으로 나타났으며, 잘 분산된 균열을 지닌 HD-3 실험체가 에너지소산능력, 강성저하 그리고 강도저하 측면에서 좋은 거동을 보여주었다.