• 제목/요약/키워드: shear strengths

검색결과 694건 처리시간 0.025초

Mechanical characteristics of hollow shear connectors under direct shear force

  • Uenaka, Kojiro;Higashiyama, Hiroshi
    • Steel and Composite Structures
    • /
    • 제18권2호
    • /
    • pp.467-480
    • /
    • 2015
  • The steel-concrete composite decks have high fatigue durability and deformability in comparison with ordinary RC slabs. Withal, the steel-concrete composite deck is mostly heavier than the RC slabs. We have proposed herein a new type of steel-concrete composite deck which is lighter than the typical steel-concrete composite decks. This can be achieved by arranging hollow sectional members as shear connectors, namely, half-pipe or channel shear connectors. The present study aims to experimentally investigate mechanical characteristics of the half-pipe shear connectors under the direct shear force. The shear bond capacity and deformability of the half-pipe shear connectors are strongly affected by the thickness-to-diameter ratio. Additionally, the shear strengths of the hollow shear connectors (i.e. the half-pipe and the channel shear connectors) are compared. Furthermore, shear capacities of the hollow shear connectors equivalent to headed stud connectors are also discussed.

PC 합성보의 수평접합면 전단력 전달성능 평가 및 설계법 분석 (Evaluation of Design Method and Shear Transfer Capacity on the Horizontal Interface of PC Composite Beams)

  • 문정호;오영훈
    • 콘크리트학회논문집
    • /
    • 제25권1호
    • /
    • pp.81-90
    • /
    • 2013
  • 이 연구에서는 합성보의 수평 접합면에 대한 수평전단력 저항성능을 평가하기 위하여 6개의 접합면 전단성능 실험체를 대상으로 접합면의 표면상태, 전단철근의 보강량과 상세 등의 구조변수에 대한 수평전단강도를 평가하였다. 휨압축파괴를 나타낸 SF-291B를 제외한 모든 실험체는 실험계획에서 의도한 대로 접합면의 수평전단력에 의한 전단파괴를 나타내었다. 설계기준식의 수평전단력 전달 또는 전단마찰 설계법으로 산정한 접합면 전단강도는 실험체의 수평전단 파괴를 초래한 접합면의 수평전단내력을 양호한 수준으로 평가하는 것으로 나타났으며, PCI 설계기준에서 제시한 전단철근의 배근상세와 정착길이는 접합면에서 요구되는 수평전단성능을 확보할 수 있다고 판단된다.

철근콘크리트 보-기둥 접합부의 전단강도 평가 (Shear Strength Estimate of Reinforced Concrete Beam-Column Joints)

  • 채희대;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.389-392
    • /
    • 2004
  • An accurate and rational analytical proposal for determining the shear strengths of interior beam-column joints is presented in this paper. The proposed equation is derived using a compatiblity aided truss model theory. The accuracy of the proposed equation was checked by comparing calculated shear strength of joints with experimental results reported papers in literature. The comparison showed that the proposed equation predicted the experimental shear strength of joints with reasonable agreement.

  • PDF

섬유보강 철근콘크리트 보의 전단강도 평가 (Shear Strength of Reinforced Concrete Beams Strengthened by Fiber Reinforced Polymer)

  • 황현복;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.401-404
    • /
    • 2004
  • In recent years, the use of fiber reinforced polymer (FRP) composites to repair or strengthen existing reinforced concrete (RC) structures is increasing In order to evaluate the shear strengths of RC structures strengthened by FRP composites, it is needed to understand the shear failure modes of these structures. This paper presents a rational equation to distinguish the shear fail modes of RC structures strengthened by FRP composites using the compatibility aided truss models.

  • PDF

Direct shear behavior of concrete filled hollow steel tube shear connector for slim-floor steel beams

  • Hosseinpour, Emad;Baharom, Shahrizan;Badaruzzaman, Wan Hamidon W.;Shariati, Mahdi;Jalali, Abdolrahim
    • Steel and Composite Structures
    • /
    • 제26권4호
    • /
    • pp.485-499
    • /
    • 2018
  • In this paper, a hollow steel tube (HST) shear connector is proposed for use in a slim-floor system. The HST welded to a perforated steel beam web and embedded in concrete slab. A total of 10 push-out tests were conducted under static loading to investigate the mechanical behavior of the proposed HST connector. The variables were the shapes (circular, square and rectangular) and sizes of hollow steel tubes, and the compressive strength of the concrete. The failure mode was recorded as: concrete slab compressive failure under the steel tube and concrete tensile splitting failure, where no failure occurred in the HST. Test results show that the square shape HST in filled via concrete strength 40 MPa carried the highest shear load value, showing three times more than the reference specimens. It also recorded less slip behavior, and less compressive failure mode in concrete underneath the square hollow connector in comparison with the circular and rectangular HST connectors in both concrete strengths. The rectangular HST shows a 20% higher shear resistance with a longer width in the load direction in comparison with that in the smaller dimension. The energy absorption capacity values showed 23% and 18% improvements with the square HST rather than a headed shear stud when embedded in concrete strengths of 25 MPa and 40 MPa, respectively. Moreover, an analytical method was proposed and predicts the shear resistance of the HST shear connectors with a standard deviation of 0.14 considering the shape and size of the connectors.

Shear bond strength of veneering ceramic to coping materials with different pre-surface treatments

  • Tarib, Natasya Ahmad;Anuar, Norsamihah;Ahmad, Marlynda
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.339-344
    • /
    • 2016
  • PURPOSE. Pre-surface treatments of coping materials have been recommended to enhance the bonding to the veneering ceramic. Little is known on the effect on shear bond strength, particularly with new coping material. The aim of this study was to investigate the shear bond strength of veneering ceramic to three coping materials: i) metal alloy (MA), ii) zirconia oxide (ZO), and iii) lithium disilicate (LD) after various pre-surface treatments. MATERIALS AND METHODS. Thirty-two (n = 32) discs were prepared for each coping material. Four pre-surface treatments were prepared for each sub-group (n = 8); a) no treatment or control (C), b) sandblast (SB), c) acid etch (AE), and d) sandblast and acid etch (SBAE). Veneering ceramics were applied to all discs. Shear bond strength was measured with a universal testing machine. Data were analyzed with two-way ANOVA and Tukey's multiple comparisons tests. RESULTS. Mean shear bond strengths were obtained for MA ($19.00{\pm}6.39MPa$), ZO ($24.45{\pm}5.14MPa$) and LD ($13.62{\pm}5.12MPa$). There were statistically significant differences in types of coping material and various pre-surface treatments (P<.05). There was a significant correlation between coping materials and pre-surface treatment to the shear bond strength (P<.05). CONCLUSION. Shear bond strength of veneering ceramic to zirconia oxide was higher than metal alloy and lithium disilicate. The highest shear bond strengths were obtained in sandblast and acid etch treatment for zirconia oxide and lithium disilicate groups, and in acid etch treatment for metal alloy group.

순환골재를 사용한 SFRC 보의 전단성능 (Shear Performance on SFRC Beam Using Recycled Coarse Aggregate)

  • 김성은;정재원;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.189-196
    • /
    • 2018
  • 순환골재를 사용한 철근콘크리트 부재에서 휨강도에 비하여 전단성능 저하가 문제점으로 제기되고 있다. 이를 해결하기 위한 방법으로 강섬유를 콘크리트 보강재로 사용할 수 있다. 본 연구에서는 순환골재를 사용한 SFRC 보의 전단실험을 통하여 강도 및 변형 특성을 파악하고자 하였다. 주요 실험변수는 강섬유 혼입률(0, 0.5%, 1%), 순환골재 치환율(0%, 100%), 전단경간비(a/d = 1, 2) 등이다. 실험결과 실험에 의한 전단강도는 강섬유의 혼입률이 증가할수록 전단경간비가 작아질수록 증가하였다. 강섬유 1% 혼입한 순환골재의 경우 일반 골재에 비해 최대전단내력이 1.77~6.25% 증가한 반면에 강섬유 0~0.5% 혼입한 실험체에서는 일반골재에 비해 순환골재가 24.2%~49.2%의 전단강도가 저하되었다. 이를 볼 때 1% 강섬유 보강에 의하여 순환골재 사용에 따른 강도 저하를 방지하는데 크게 기여하는 것을 알 수 있다.

비균열 인장재하 시험체의 압축장 이론에 기반한 전단전달강도 산정모델 (Estimation Model of Shear Transfer Strength for Uncracked Pull-Off Test Specimens based on Compression Field Theory)

  • 김민중;이기열
    • 대한토목학회논문집
    • /
    • 제41권2호
    • /
    • pp.101-111
    • /
    • 2021
  • 전단마찰 시험체는 재하형태에 따라 압축재하와 인장재하 시험으로 구분된다. 인장재하 시험의 경우에는 외력으로 작용하는 수직방향 인장력에 의하여 전단응력 및 수직방향 인장응력이 유발된다. 이 연구에서는 압축장 이론을 이용하여 인장재하 시험체의 전단전달강도를 평가하였으며, 2축-응력 상태의 콘크리트 최대 압축강도의 변화를 고려하기 위하여 수정압축장이론, 연화트러스모델의 구성방정식을 사용하였다. 타당성 검증을 위하여 과거 연구자들에 의해 수행된 직접전단강도 실험값들과 압축장 이론을 이용하여 구한 값들을 비교한 결과, 비균열 인장재하 시험체의 경우 예측값과 실측치가 대체적으로 잘 일치함을 확인하였다. 또한 콘크리트 스트럿의 유효압축강도를 고려한 전단강도 평가식을 제안하고, 기존 문헌에 수록된 실험결과와 비교함으로써 제안식의 적용 가능성을 검증하였다.

치과 도재용 합금과 도재간의 결합력에 관한 연구 (Study of the Bond Strength Between Dental Ceramic Alloys and Porcelain)

  • 윤일중
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.29-37
    • /
    • 1981
  • The bond strengths with ceramco porcelain were compared between precious alloy S, and non-precious alloys V.U. and R. And the changes in bond strengths of non-precious alloys with ceramco porcelain, according to surface preparations by sand blasting, longitudinal grinding, transverse grinding, and high polishing, were studied. The test specimens were prepared by firing porcelain doughnuts on the surface prepared alloy rods, and investing in dental stone. The specimens were subjected to shear loading forces. The conclusions drawn from the investigation are as follows: 1. The bond strengths with ceramco porcelain were higher in the non-precious alloys U and R, than in the precious alloy S. 2. The bond strengths were in descending order for R alloy, U alloy, V alloy, and S alloy. 3. The bond strengths were highest when the R alloy and U alloy were surface prepared by sand blasting. 4. All bond strength values were lowest when the alloy surfaces were prepared by high polishing.

  • PDF

광중합 접착제로 접착된 금속 브라켓의 전단접착강도에 관한 연구 (SHEAR BOND STRENGTH OF METAL BRACKETS BONDED WITH LIGHT-CURED ADHESIVE: AN IN VITRO COMPARATIVE STUDY)

  • 장영일;이승진
    • 대한치과교정학회지
    • /
    • 제22권2호
    • /
    • pp.289-296
    • /
    • 1992
  • The purpose of this study was to evaluate and compare the shear bond strengths and failure sites of metal brackets bonded with chemically cured adhesive and light-cured adhesive. 10 brackets were bonded on prepared enamel surfaces with $Transbond^{circledR}$ (Unitek/3M; U.S.A.) light-cured orthodontic adhesive and another 10 brackets were bonded with $Ortho-one^{\circledR}$ (Bisco:U.S.A.) chemically cured orthodontic adhesive. 24 hours after bonding, the Instron universal testing machine was used to measure the shear bond strengths. The failure sites were examined under streoscopic microscope. The results were as follows: 1 . The mean shear bond strength of metal brackets bonded with light-cured adhesive was lower than that of metal brackets bonded with chemically cured adhesive, but the difference was not statistically significant (p < 0.05). 2. Regardless of the type of adhesives, the brackets were failed primarily at the bracket base-adhesive interface. 3. Bonding of metal brackets with light-cured adhesive is considered to be clinically acceptable.

  • PDF