• 제목/요약/키워드: shear strength of joints

검색결과 427건 처리시간 0.028초

1050 Al판재의 핀 마찰 교반용접에 의한 실험적 연구 (Weldability and properties of lap joints by pin FSW with 1050 Al sheet)

  • 장석기;박종식;한민수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권4호
    • /
    • pp.394-400
    • /
    • 2007
  • The properties and weldability of lap joints by PFSW with 1050 Al sheet was investigated according to tool shape. dimension and welding condition. Tensile shear test was carried out for lap jointed specimen, and the hardness in the joint regions was examined. Moreover interfacial joining length, metallograph and failure location of the lap-jointed cross section were discussed. Two tool types were a simple cylindrical type and a notched cylindrical type. Under joining conditions such as plunging depth of 2.2mm. rotating speed of 1600rpm and dwelling time of 3s, the tensile shear strength of lap-jointed specimen by the notched type tool was superior to that by simple cylindrical type tool. The maximum tensile shear load of lap jointed specimen was 5807N. Optimal dimensions of the notched type tool were as follows : diameters of the shoulder and pin were $18{\phi}mm$ and $10{\phi}mm$, and pin length was 2.2mm.

복합재 샌드위치 구조의 인써트 조인트의 강도 향상 (Strength Improvement of Insert Joint for Composite Sandwich Structure)

  • 김광수;안재모;장영순;이영무
    • 한국항공우주학회지
    • /
    • 제38권1호
    • /
    • pp.29-34
    • /
    • 2010
  • 본 연구에서는 새롭게 개발된 "강도 향상 인써트"에 대해 조인트 시편을 제작하여 Pull-out 및 전단시험을 수행하여 보통 인써트의 조인트 강도와 비교하고 그 파손 특성을 조사하였다. 이를 통해 새로운 인써트에 대한 성능을 확인하였다. 시험 결과, 새로운 "강도 향상 인써트"는 기존의 보통 인써트에 비해 Pull-out 강도는 2.1배, 전단강도는 2.04배 향상되는 것을 확인하였다. 따라서 향후 높은 인써트 강도를 요구하는 구조에 유용하게 사용될 수 있을 것이다.

시공이음부 계면처리방법에 따른 초고성능 콘크리트의 전단부착성능 평가에 관한 실험적 연구 (An Experimental Study on the Bonding Shear Performance Evaluation of the UHPC According to an Bonding Interface Treatment of the Construction Joint)

  • 장현오;김보석;이한승
    • 한국건축시공학회지
    • /
    • 제16권3호
    • /
    • pp.237-245
    • /
    • 2016
  • 시공이음부 발생에 따른 초고성능 콘크리트의 일체성을 확보하기 위해서는 그 특성을 수반함과 동시에 전단부착성능에 대한 정량적인 계면처리방법이 필요할 것으로 판단된다. 이에, 본 연구는 초고성능 콘크리트 타설 시, 발생하는 시공이음부의 부착성능을 확보하기 위한 일환으로서 시공이음부 계면처리방법에 따른 전단부착성능 평가를 통하여 재료적인 측면에서의 합리적인 계면처리방법을 도출하고자 한다. 초고성능 콘크리트 배합은 180MPa의 배합강도를 사용하였으며, 계면처리방법으로는 MN, AC, GR-10-0, GR-20-0, GR-30-0, SH-30-5, SH-30-10으로써 총 7수준으로 설정하였다. 실험체는 $150{\times}150{\times}150mm$의 Size로 제작 후, 전단부착강도 평가를 위하여 Direct shear test를 실시하였다. 실험결과, 시공이음부 접합면에 대해 계면처리를 실시한 경우 부착성능이 향상되는 것을 확인하였으며, 접합부 단면적이 증가할수록 초고성능 콘크리트의 일체성 확보에 유리할 것으로 판단된다. 또한 콘크리트의 일체성을 확보하기 위해서는 접합면 단면적의 비율 및 요철의 깊이, 개수 등이 적절히 고려되어야 할 것으로 판단된다.

프리캐스트 대헝판 구조물의 접합부에 관한 탄소성해석 (Elasto-Plastic Analysis on Connections of Precast Large Panel Structures)

  • 권택진;박강근;권익노;조강표
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 봄 학술발표회논문집
    • /
    • pp.27-34
    • /
    • 1993
  • Precast large panel structures behave differently form frame and monolithic wall structures under external loads, because of the distinct planes of weakness in the horizontal and vertical joints between panels. These joints may slide and open during shaking, producing large localized changes in the bending and shear stiffness of individual walls. The structural behavior of large precast panel buildings depends on the relative strength and stiffness of the panels and joints. Special modeling are thus required for the analysis of precast panel connections. This study suggests a new analytical modeling and method to obtain the rational estimation of discontinuity and slip movements form the connections of precast large panel structures .

  • PDF

점용접 시편의 피로 수명 해석 (Analysis of Fatigue Life of Spot-Welded Specimens)

  • 주영우;주석재;최병길;염영진;유희
    • 한국자동차공학회논문집
    • /
    • 제7권6호
    • /
    • pp.279-286
    • /
    • 1999
  • Failure of spot-weld joints in car body may cause noise, vibration and safety problems. Systematic procedures for estimating fatigue strength of general spot-weld joints are developed in this paper. Fatigue test results for various spot-welded specimens are analysed using the finite element method. It is found that the maximum principal strain at the nugget boundary on the inner surface governs the fatigue failure of spot-welded joints.

  • PDF

Seismic repair of exterior R/C beam-to-column joints using two-sided and three-sided jackets

  • Tsonos, Alexander G.
    • Structural Engineering and Mechanics
    • /
    • 제13권1호
    • /
    • pp.17-34
    • /
    • 2002
  • The use of local two-sided and three-sided jacketing for the repair and strengthening of reinforced concrete beam-column joints damaged by severe earthquakes is investigated experimentally and analytically. Two exterior beam-column joint specimens ($O_1$ and $O_2$) were submitted to a series of cyclic lateral loads to simulate severe earthquake damage. The specimens were typical of existing older structures built in the 1960s and 1970s. The specimens were then repaired and strengthened by local two-sided or three-sided jacketing according to UNIDO Manual guidelines. The strengthened specimens ($RO_1$ and $RO_2$) were then subjected to the same displacement history as that imposed on the original specimens. The repaired and strengthened specimens exhibited significantly higher strength, stiffness and better energy dissipation capacity than the original specimens.

고리후프형 띠근을 기진 RCS구조 접합부의 거동에 관한 실험적 연구 (Experimental study on RCS Beam Column Joints With Hooked Cross ties)

  • 박상균;손민성;오정근;오경환;문정호;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.625-628
    • /
    • 2000
  • Recently, composite structural systems have been developed actively due to its structural advantages of combining different materials. The objective of this paper is to investigate the structural behavior of composite connection which consist of steel beams and reinforced concrete columns (RCS). Five 2/3 scale joint specimens with variables mainly consist of shear resisting details, were tested under reversal loads. The results showed that RCS beam-column joints maintain ductility, strength compared to other RCS joints and exhibited excellent energy dissipating capacity when subjected to inelastic deformations under reversal load.

  • PDF

저항점용접과 $CO_2$ 플러그용접의 피로거동 연구 (The comparision of fatigue behavior of $CO_2$ plug weld and resistance spot weld)

  • 정원욱;정연수;강성수
    • 대한기계학회논문집A
    • /
    • 제22권3호
    • /
    • pp.554-561
    • /
    • 1998
  • Vehicle body structures are formed by thousands of spot welds and fatigue failure of vehicle structures occur near the spot welds after driving a long way at a durability test road. It is necessary to know accurately the reason of the fatigue failure of the spot weld in the developing stage in order to reinforce it. Many investigations have been done regarding the strength of spot welded joints, contributing to understand its fatigue strength. In developing process, a fatigue failed spot welded area can be repaired by $CO_2$ welding or another method to continue the test. To know the effect of reinforcing these welds, several methods of welding were analyzed and compared to spot welding. With the results of this test, the appropriate repair method can be used instead of spot welding during the development of new car and best design guide can be given for the strength. In this study, fatigue and static tensile tests are made and microstructure is investigated for the purpose of estimating the strength of welded joints by using spot welded and $CO_2$ plug welded specimens. The tested specimens are of two types : Tensile-shear type(TS) and L-tension type(LT).

Experimental and numerical investigation on exposed RCFST column-base Joint

  • Ben, Mou;Xingchen, Yan;Qiyun, Qiao;Wanqiu, Zhou
    • Steel and Composite Structures
    • /
    • 제45권5호
    • /
    • pp.749-766
    • /
    • 2022
  • This paper investigates the seismic performance of exposed RCFST column-base joints, in which the high-strength steel bars (USD 685) are set through the column and reinforced concrete foundation without any base plate and anchor bolts. Three specimens with different axial force ratios (n = 0, 0.25, and 0.5) were tested under cyclic loadings. Finite element analysis (FEA) models were validated in the basic indexes and failure mode. The hysteresis behavior of the exposed RCFST column-base joints was studied by the parametrical analysis including six parameters: width of column (D), width-thickness ratio (D/t), axial force ratio (n), shear-span ratio (L/D), steel tube strength (fy) and concrete strength (fc). The bending moment of the exposed RCFST column-base joint increased with D, fy and fc. But the D/t and L/D play a little effect on the bending capacity of the new column-base joint. Finally, the calculation formula is proposed to assess the bending moment capacities, and the accuracy and stability of the formula are verified.

Behavior of composite CFST beam-concrete column joints

  • Kim, Seung-Eock;Choi, Ji-Hun;Pham, Thai-Hoan;Truong, Viet-Hung;Kong, Zhengyi;Duong, Nguyen-The;Vu, Quang-Viet
    • Steel and Composite Structures
    • /
    • 제37권1호
    • /
    • pp.75-90
    • /
    • 2020
  • This paper introduces a new composite joint, which is the composite CFST beam- concrete column joint, and it is more convenient for transportation and erection than conventionally welded joints. The main components of this joint include steel H-beams welded with CFST beams, reinforced concrete columns, and reinforced concrete slabs. The steel H-beams and CFST beams are connected with a concrete slab using shear connectors to ensure composite action between them. An experimental investigation was conducted to evaluate the proposed composite joint performance. A three-dimensional (3D) finite element (FE) model was developed and analyzed for this joint using the ABAQUS/explicit. The FE model accuracy was validated by comparing its results with the relevant test results. Additionally, the parameters that consisted of the steel box beam thickness, concrete compressive strength, steel yield strength, and reinforcement ratio in the concrete slab were considered to investigate their influence on the proposed joint performance.