• 제목/요약/키워드: shear strength criterion

검색결과 127건 처리시간 0.024초

Interactive strut-and-tie-model for shear strength prediction of RC pile caps

  • Chetchotisak, Panatchai;Yindeesuk, Sukit;Teerawong, Jaruek
    • Computers and Concrete
    • /
    • 제20권3호
    • /
    • pp.329-338
    • /
    • 2017
  • A new simple and practical strut-and-tie model (STM) for predicting the shear strength of RC pile caps is proposed in this paper. Two approaches are adopted to take into account the concrete softening effect. In the first approach, a concrete efficiency factor based on compression field theory is employed to determine the effective strength of a concrete strut, assumed to control the shear strength of the whole member. The second adopted Kupfer and Gerstle's biaxial failure criterion of concrete to derive the simple nominal shear strength of pile caps containing the interaction between strut and tie capacity. The validation of these two methods is investigated using 110 RC pile cap test results and other STMs available in the literature. It was found that the failure criterion approach appears to provide more accurate and consistent predictions, and hence is chosen to be the proposed STM. Finally, the predictions of the proposed STM are also compared with those obtained by using seven other STMs from codes of practice and the literature, and were found to give better accuracy and consistency.

The multi-axial strength performance of composited structural B-C-W members subjected to shear forces

  • Zhu, Limeng;Zhang, Chunwei;Guan, Xiaoming;Uy, Brian;Sun, Li;Wang, Baolin
    • Steel and Composite Structures
    • /
    • 제27권1호
    • /
    • pp.75-87
    • /
    • 2018
  • This paper presents a new method to compute the shear strength of composited structural B-C-W members. These B-C-W members, defined as concrete-filled steel box beams, columns and shear walls, consist of a slender rectangular steel plate box filled with concrete and inserted steel plates connecting the two long-side steel plates. These structural elements are intended to be used in structural members of super-tall buildings and nuclear safety-related structures. The concrete confined by the steel plate acts to be in a multi-axial stressed state: therefore, its shear strength was calculated on the basis of a concrete's failure criterion model. The shear strength of the steel plates on the long sides of the structural element was computed using the von Mises plastic strength theory without taking into account the buckling of the steel plate. The spacing and strength of the inserted plates to induce plate yielding before buckling was determined using elastic plate theory. Therefore, a predictive method to compute the shear strength of composited structural B-C-W members without considering the shear span ratio was obtained. A coefficient considering the influence of the shear span ratio was introduced into the formula to compute the anti-lateral bearing capacity of composited structural B-C-W members. Comparisons were made between the numerical results and the test results along with this method to predict the anti-lateral bearing capacity of concrete-filled steel box walls. Nonlinear static analysis of concrete-filled steel box walls was also conducted by using ABAQUS and the results agreed well with the experimental data.

암석 절리의 3차원 거칠기 특성화와 수정 전단강도 관계식의 제안 (Characterization of the Three Dimensional Roughness of Rock Joints and Proposal of a Modified Shear Strength Criterion)

  • 장보안;김태호;장현식
    • 지질공학
    • /
    • 제20권3호
    • /
    • pp.319-327
    • /
    • 2010
  • 19개의 절리면에 대해 레이저 스캐너를 이용하여 형상을 측정한 후, 각 절리면의 30개 단면에 대하여 절리 거칠기 계수(Joint Roughness Coefficient)를 계산하였다. JRC 값은 단면의 위치에 따라 매우 큰 차이를 보이고 있으나 3개의 단면에서 측정된 JRC의 평균값은 절리면 전체의 JRC 평균값을 잘 대표할 수 있을 것으로 판단된다. 9개의 절리면에 대해서 석고를 이용한 복제 시료를 제작하여 절리면 전단시험을 실시하였다. 최대마찰각(${\phi}_p$)은 JRC의 평균값과 ${\phi}_p=41.037+1.046JRC$의 직선의 관계를 보인다. 그러나 절리면 전단시험에서 측정된 전단강도는 절리면에서 측정된 JRC의 평균값을 사용하여 Barton의 관계식에서 추정된 전단강도보다 상당한 오차를 보여, 절리면 전단시험에서 역산된 $JRC_R$과 JRC의 관계를 $JRC_R=f{\cdot}JRC$로 정의하고 회귀분석하여 수정계수 $f=3.15JRC^{-0.5}$를 도출하였고, 이 수정계수를 적용하여 Barton의 전단강도 관계식을 ${\tau}={\sigma}_n{\cdot}tan(3.15JRC^{0.5}{\bullet}{\log}_{10}\frac{JCS}{{\sigma}_n}+{\phi}_b)$로 수정하여 제안하였다. 이 관계식은 강도가 비교적 낮고 연성의 특성을 보이는 풍화암이나 연암의 절리면 전단강도 추정에 적용될 것으로 기대된다.

절리암반사면의 안정해석 방법에 관한 비교연구 (A Comarative study on slope stability modeling of highly fractured rock slopes)

  • 유충식;김선빈;양기호;정하승
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.434-443
    • /
    • 2009
  • Slope stability analysis is an essential part of rock slope design. For highly fractured rock, the limit equilibrium method (LEM) based slope stability analysis with a circular failure surface is often carried out assuming the rock mass behaves more or less as a continuum. This paper examines first, the applicability of the finite-element method (FEM) based shear strength reduction (SSR) technique for highly fractured rock slope, and second the use of Mohr-Coulomb (MC) failure criterion in conjunction with generalized Hoek-Brown (HB) failure criterion. The numerical results on a number of cases are compared in terms of the factor of safety (FS). The results indicated that the FEM-based SSR technique yields almost the same FSs from LEM, and that the MC and HB failure criteria yield almost identical FSs when the strength parameters for MC failure criterion are obtained based on the modified HB failure criterion if and only if value of the Hoek-Brown constant $m_i$ is smaller than 10 and slope angle is smaller than 1:1, otherwise MC failure criteria over-estimate the factor of safety.

  • PDF

Deterioration in strength of studs based on two-parameter fatigue failure criterion

  • Wang, Bing;Huang, Qiao;Liu, Xiaoling
    • Steel and Composite Structures
    • /
    • 제23권2호
    • /
    • pp.239-250
    • /
    • 2017
  • In the concept of two-parameter fatigue failure criterion, the material fatigue failure is determined by the damage degree and the current stress level. Based on this viewpoint, a residual strength degradation model for stud shear connectors under fatigue loads is proposed in this study. First, existing residual strength degradation models and test data are summarized. Next, three series of 11 push-out specimen tests according to the standard push-out test method in Eurocode-4 are performed: the static strength test, the fatigue endurance test and the residual strength test. By introducing the "two-parameter fatigue failure criterion," a residual strength calculation model after cyclic loading is derived, considering the nonlinear fatigue damage and the current stress condition. The parameters are achieved by fitting the data from this study and some literature data. Finally, through verification using several literature reports, the results show that the model can better describe the strength degradation law of stud connectors.

Torsion strength of single-box multi-cell concrete box girder subjected to combined action of shear and torsion

  • Wang, Qian;Qiu, Wenliang;Zhang, Zhe
    • Structural Engineering and Mechanics
    • /
    • 제55권5호
    • /
    • pp.953-964
    • /
    • 2015
  • A model has been proposed that can predict the ultimate torsional strength of single-box multi-cell reinforced concrete box girder under combined loading of bending, shear and torsion. Compared with the single-cell box girder, this model takes the influence of inner webs on the distribution of shear flow into account. According to the softening truss theory and thin walled tube theory, a failure criterion is presented and a ultimate torsional strength calculating procedure is established for single-box multi-cell reinforced concrete box girder under combined actions, which considers the effect of tensile stress among the concrete cracks, Mohr stress compatibility and the softened constitutive law of concrete. In this paper the computer program is also compiled to speed up the calculation. The model has been validated by comparing the predicted and experimental members loaded under torsion combined with different ratios of bending and shear. The theoretical torsional strength was in good agreement with the experimental results.

모래에서 인장력을 고려한 Mohr-Coulomb 파괴규준 (Mohr-Coulomb Failure Criterion with Tensile Strength in Sand)

  • 김태형;이용수;황웅기;강기민;안영균
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.963-971
    • /
    • 2008
  • Unsaturated soil mechanics has been often used to find out a cause of failure (tensile failure) of retaining walls and hill slopes containing sandy soils. Checking shear strength is a popular method by considering suction stress developed form pore water menisci among the grains and saturated pockets of pore water under negative pressure. Linear Mohr-Coulomb failure criterion is generally adopted as a failure criterion. However, depending on relative density, stress history, and the magnitude of stress, the failure behavior of sand may not follow linear M-C frictional behavior. For stress in the large compressive ranges, say from tens to hundreds of kPa, the linear M-C criterion is an adequate representation for the shear strength behavior of sand. However, less than tens of kPa, the M-C criterion often can not be accurately represented. Depending on failure criterion, the uniaxial tensile strength is different over 100% relative error. For sand behavior under small compression regimes, therefore, such as under low or zero gravity, or under undergoing tensile failure in the crest area of hill slopes or behind retaining walls, it is important to consider the non-linear behavior.

  • PDF

Shearing characteristics of slip zone soils and strain localization analysis of a landslide

  • Liu, Dong;Chen, Xiaoping
    • Geomechanics and Engineering
    • /
    • 제8권1호
    • /
    • pp.33-52
    • /
    • 2015
  • Based on the Mohr-Coulomb failure criterion, a gradient-dependent plastic model that considers the strain-softening behavior is presented in this study. Both triaxial shear tests on conventional specimen and precut-specimen, which were obtained from an ancient landslide, are performed to plot the post-peak stress-strain entire-process curves. According to the test results of the soil strength, which reduces from peak to residual strength, the Mohr-Coulomb criterion that considers strain-softening under gradient plastic theory is deduced, where strength reduction depends on the hardening parameter and the Laplacian thereof. The validity of the model is evaluated by the simulation of the results of triaxial shear test, and the computed and measured curves are consistent and independent of the adopted mesh. Finally, a progressive failure of the ancient landslide, which was triggered by slide of the toe, is simulated using this model, and the effects of the strain-softening process on the landslide stability are discussed.

LE analysis on unsaturated slope stability with introduction of nonlinearity of soil strength

  • Deng, Dong-ping;Lu, Kuan;Li, Liang
    • Geomechanics and Engineering
    • /
    • 제19권2호
    • /
    • pp.179-191
    • /
    • 2019
  • Based on the effective stress principle, a new formula for shear strength of unsaturated soil is derived under the general nonlinear Mohr-Coulomb (M-C) strength criterion to improve the classical strength criterion of unsaturated soil. Meanwhile, the simple irrigation model under steady seepage is adopted to obtain the distribution of the matrix suction or the degree of saturation (DOS) above the groundwater table in the slope. Then, combined with the improved strength criterion of unsaturated soil and the simple irrigation model under steady seepage, the limit equilibrium (LE) solutions for the unsaturated slope stability are established according to the global LE conditions of the entire sliding body with assumption of the stresses on the slip surface. Compared to the classical strength criterion of unsaturated soil, not only the cohesion soil but also the internal friction angle is affected by the matric suction or the DOS in the improved strength criterion. Moreover, the internal friction angle related to the matric suction has the nonlinear characteristics, particularly for a small of the matric suction. Thereafter, the feasibility of the present method is verified by comparison and analysis on some slope examples. Furthermore, stability charts are also drawn to quickly analyze the unsaturated slope stability.

알루미나 튜브의 복합하중 파괴에 미치는 압축응력의 영향 (Effect of Compressive Stress on Multiaxial Loading Fracture of Alumina Tubes)

  • 김기태;서정
    • 한국세라믹학회지
    • /
    • 제28권10호
    • /
    • pp.810-818
    • /
    • 1991
  • Fracture responses of Al2O3 tubes were investigated for various loading paths under combined tension/torsion. The fracture criterion did not depend on loading paths. Fracture angles agreed well with the maximum tensile stress criterion. As the loading condition approaches a shear dominant state, the tensile principal stress at fracture increases compared to the uniaxial fracture strength. By using the Weibull modulus obtained from tension and torsion tests, the Weibull statistical fracture strengths were compared with experimental data. This comparison suggests that fracture may occur at the surface of the specimen when tensile stress is dominant, but within the volume of the specimen when shear stress is dominant. The Weibull fracture strength increased as the loading conition approached a shear dominant state, but underestimated compared to experimental data. Finally, a new fracture criterion was proposed by including the effect of compressive principal stress. The proposed criterion agreed well with experimental data of Al2O3 tubes not only at combined tension/torsion but also at balanced biaxial tension.

  • PDF