• Title/Summary/Keyword: shear strength characteristic

Search Result 187, Processing Time 0.03 seconds

Strength and Deformation Characteristic of Two-Phase Mixture Soil (폐기물을 포함한 이종혼합토의 강도·변형특성)

  • Lee, Ki-Ho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.2
    • /
    • pp.33-39
    • /
    • 2001
  • In order to utilize mass of oyster shells for a partial substitute material for reclamation, the shear characteristics of two-phase mixture soil with oyster shells were investigated with $\overline{CU}$ test. From various experiments, it was found that the increase of mixed ratio of oyster shells causes the shear strength of mixed soil. And this phenomenon not only depends on friction due to confining pressure such as pure clay but also is influenced by shaping skeleton of oyster shells. Also, it was discovered that there were many influences by clay-oyster shell mixture from the study of the secant modulus and dilatancy characteristics of mixed soil. In addition, variation of oyster shell skeleton during shearing stage is examined applying modifying coefficient concept.

  • PDF

A Study on the Mechanical Characteristics of Compression Member Confined the Cast Frame Using Continuous Fiber Mesh (연속섬유 거푸집으로 보강된 압축부재의 역학적 특성에 관한 연구)

  • Ko, Hune-Bum
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.4
    • /
    • pp.99-104
    • /
    • 2002
  • Recently, the continuous fiber materials has become more important materials to repair and to reinforce concrete structural members. Continuous fiber meshes are effective for shear and confining reinforcement and provide excellent durability when combined with high strength mortar The purpose of this study is to verify the relationship between concrete strength and the ductility of inner concrete confined laterally by continuous fiber meshes. For this study, Experimental studies were conducted by compressive members using the cast frame of high strength mortar and continuous fiber meshes. Therefore, the result shows that compressive strength and ductility has improved according to the amount of the fiber meshes, and that the lateral confined effect of members with 3- or 4-axis mesh arrangement is bigger than that of members with 2-axis mesh. These data have to be used to verify the characteristic of concrete structure members reinforced continuous fiber mesh.

Characteristic Analysis of Shear Strength of Rock Slope Discontinuity in Yangsan Fault System (양산단층대 암반비탈면에 분포하는 불연속면의 전단강도 특성분석)

  • Lee, Hak-Ju;Kim, Chang-Ho;Hwang, Woong-Ki;Kim, Tae-Hyung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.3
    • /
    • pp.11-22
    • /
    • 2019
  • This study was conducted to identify the causes of the unusually high number of rock slope failures during an expressway construction in Yangsan fault system. The shear strength (cohesion and internal friction angle) of 128 slopes of discontinuities including bedding, joint, and fault planes were re-evaluated through the examination of face mapping and back analysis. The re-evaluated values were analyzed and then compared with the existing data and values used in the design. As a result, the re-evaluated cohesion and friction angles were very low compared to the existing data and the values applied in the design. This incongruity was pointed as the primary reason for the rock slopes failures during the construction. This may be related to the inherent features of clastic sedimentary rocks in the study area, and the discontinuities in the sedimentary rocks in this region played a significant role. Especially, bedding discontinuity showed a big difference compared to the existing data. The shear strength depended on the type of discontinuity in case of clay filled in discontinuity. However, shear strength was independent on the type of discontinuity in case of shattered materials filled in discontinuity.

Hysteretic Behavior of R/C Shear Wall with Various Lateral Reinforcements in Boundary Columns for Cyclic Lateral Load (경계부재내 횡보강근 배근방법에 따른 R/C전단벽의 반복하중에 대한 이력거동)

  • Seo, Soo-Yeon;Oh, Tae-Gun;Kim, Kyeong-Tae;Yoon, Seong-Joe
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.357-366
    • /
    • 2010
  • This paper presents experimental results about shear wall with various lateral reinforcement details in boundary elements. The research objective is to study the structural behavior of shear wall with boundary column confined by rectangular spiral hoops and headed cross ties developed to improve workability in the fabrication of boundary columns. These two details can be fabricated in a factory and put together on-site after being delivered so that the construction work may be reduced. Main parameters in the experimental study were the types of hoop and cross tie: rectangular spiral hoop and headed cross tie vs. standard hoop and cross tie with hook. Four half scaled shear wall specimens with babel shape were made and tested by applying horizontal cyclic load under constant axial force, 10% of nominal compressive strength of concrete. Based on the test result, it was shown that the shear wall with rectangular spiral hoop and headed cross tie in boundary columns has structural capacity compatible with conventional shear wall. The specimen SW-Hh which has bigger hoop bar and higher volumetric ratio of transverse reinforcements than other showed improved energy dissipating characteristic but it presented a rapid reduction of strength after peak point. The results indicates that, it is necessary to consider volumetric ratio of transverse reinforcements as well as hoop space in designing of shear wall with boundary columns for improved strength and ductility.

Effect of Aspect Ratio and Diagonal Reinforcement on Shear Performance of Concrete Coupling Beams Reinforced with High-Strength Steel Bars (세장비 및 대각철근 유무에 따른 고강도 철근보강 콘크리트 연결보의 전단성능)

  • Kim, Sun-Woo;Jang, Seok-Joon;Yun, Hyun-Do;Seo, Soo-Yeon;Chun, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.1
    • /
    • pp.43-51
    • /
    • 2017
  • As per current seismic design codes, diagonally reinforced coupling beams are restricted to coupling beams having aspect ratio below 4. However, a grouped diagonally reinforcement detail makes distribution of steel bars in the beam much harder, furthermore it may result in poor construction quality. This paper describes the experimental results of concrete coupling beam reinforced with high-strength steel bars (SD500 & SD600 grades). In order to improve workability for fabricating coupling beams, a headed large diameter steel bar was used in this study. Two full-scale coupling beams were fabricated and tested with variables of reinforcement details and aspect ratio. To reflect real behavior characteristic of the beam coupling shear walls, a rigid steel frame system with linked joints was set on the reaction floor. As a test result, it was noted that cracking and yielding of reinforcement were initially progressed at the coupling beam-to-shear wall joint, and were progressed to the mid-span of the coupling beam, based on the steel strain and failure modes. It was found that the coupling beams have sufficient deformation capacity for drift ratio of shear wall corresponding to the design displacement in FEMA 450-1. In this study, the headed horizontal steel bar was also efficient for coupling beams to exhibit shear performance required by seismic design codes. For detailed design for coupling beam reinforced with high-strength steel, however, research about the effect of variable aspect ratios on the structural behavior of coupling beam is suggested.

The Strength Characteristic of Oil Contaminated Clayey Soil (유류 오염 점성토의 강도 특성)

  • Kwon, Moo-Nam;Kim, Hyun-Ki;Nam, Hyo-Suk;Goo, Jung-Min
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.183-186
    • /
    • 2003
  • This study was conducted to evaluate effects by adding oil to clay soil and influences of remained oil in soil as time elapsed. Unconfined compression test and direct shear test were performed to analyze strength properties of contaminants in clayey soil. As a results of $q_u$ test for kerosene and diesel contaminated clayey soil indicate that were decreased from near 5% oil content rapidly and the declination of strength were blunt as oil content over 10%. The cohesions(c) and internal friction angle(${\psi}$) of kerosene contaminated clayey soil were not varied as quantities of kerosene in clayey soil increased. In the case of diesel contaminated clayey soil, the cohesions(c) were decreased and the internal friction angle(${\psi}$) were increased.

  • PDF

An Assessment of Safety Zone for Mountain Tunnel Portal Using Strength Reduction Technique (강도감소법을 이용한 산악터널 갱구부의 안전영역 평가)

  • Hong, Chang-Soo;Hwang, Dae-Jin;Lee, Kang-Ho;You, Kwang-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.925-930
    • /
    • 2006
  • During the excavation of a tunnel portal, failure zones around the tunnel heading occur and also the ground supports itself. In a portal, its location and the ground characteristic have a great influence on the stability of the tunnel. Therefore, the failure mechanism of a tunnel heading and how to assess the stability of the tunnel are very important. In this paper, the numerical analyses were executed to evaluate the safety factor using strength reduction technique. The influence area of an excavation was also predicted through a case study in which no-support case and support case with the Pattern P-6 were compared in terms of the ground class and the shear strain.

  • PDF

Characteristic of the Nocturnal Inversion Layer observed by Tethersonde in Daegu (계류기구로 관측한 대구시 야간 안정층 특성에 관한 사례연구)

  • 김희종;윤일희;권병혁;허만천
    • Journal of Environmental Science International
    • /
    • v.11 no.3
    • /
    • pp.155-160
    • /
    • 2002
  • Using measured data at Daegu by tethersonde for the period of 1984∼1987, we have investigated the lower atmospheric boundary layer structure including relationships between inversion layer and meteorological factors(wind and temperature), and the inversion strength and inversion height. The inversion layer was defined from the vertical temperature profile and its strength was analyzed with the wind shear as well as the vertical temperature gradient. From October to January, measured inversion layer isn't destroyed, however, in June, after sun rise, it is destroyed by surface heating and mixed layer is developed from surface. According to Pasquill stability classes, the moderately stable cases dominated. It's the larger vertical temperature gradient the lower SBL height. We have introduced B(bulk turbulence scale) which indicated SBL height. It's larger B, the higher SBL height and vice versa. It was noted that the bulk turbulence scale (B) is appropriate to determine the stable boundary layer height.

The Flexible Characteristic of Reversible and Robust Nanohair Fastener

  • Park, Seung-Ho;Yoon, Young-Seok;Lee, Dong-Woo;Lee, Dong-Ik;You, Kyoung-Hwan;Pang, Chang-Hyun;Suh, Kahp-Yang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.432-432
    • /
    • 2011
  • Dry adhesion caused by Nanoscale contact comes up to important scientific issue. Herein, we introduce bendable nanohairy locking fastener system with high shear strength and mechanically flexible backing. The polymeric patches like velcro are composed of an array of straight nanohairs with 100 nm diameter and $1{\mu}m$ height. To fabricate high aspect vertical nanohairs, we used UV molding method with appropriately flexible and rigid polyurethane acrylate material on PET substrate. Two identical nanohairy patches are easily merged and locked each other induced by van der Waals force. Because nanohairs can be arrayed with high density ${\sim}4{\times}10^8/cm^2$, we can obtain high shear adhesion force on flat surface (~22 N/$cm^2$). Furthermore, we can obtian nanohairy locking system with maximum shear adhesion ~48 N/$cm^2$ of curved surface due to flexibility of PET substrate. We confirm the tendency that shear adhesion force increases, as radius of curvature increases.

  • PDF

Behavior of Coupling Shear Wall with New Openings (개구부 신설에 따른 병렬 전단벽의 거동특성)

  • Choi, Hyun-Ki;Choi, Youn-Cheul;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.5
    • /
    • pp.152-160
    • /
    • 2008
  • Since wall system apartment used the shear wall as main lateral resistance member, installation of openings which causing section loss of walls may cause significant problem to structure. Also, there are few studies for inducing coupling beam or slabs which are occurred by installing openings. Therefore, this study planned isolated 2-story shear walls which are reduced three half-scale specimen to find out walls behavior characteristic. The test results showed that strength reduction caused by loss of effective section of walls and different result of stiffness and energy dissipation regarding to the coupling beam and coupling slabs.