• Title/Summary/Keyword: shear rigidity

Search Result 176, Processing Time 0.027 seconds

Fatigue Strength Evaluation on the IB-Type Spot-welded Lap Joint of 304 Stainless Steel Part 1 : Maximum Principal Stress (304 스테인리스 박강판 IB형 점용접이음재의 피로강도 평가 Part 1 : 최대 주응력에 의한 평가)

  • 손일선;오세빈;배동호
    • Journal of Welding and Joining
    • /
    • v.17 no.6
    • /
    • pp.25-31
    • /
    • 1999
  • Stainless steel sheets are commonly used for vehicles such as the bus and the train. These are mainly fabricated by spot-welding. By the way, its fatigue strength is lower than base metal due to high stress concentration at the nugget. edge of the spot-welding. By the way, its fatigue strength is lower than base metal due to high stress concentration at the nugget edge of the spot-welding point. Especially, it is influenced by welding conditions as well as geometrical factors of spot welded joint. Therefore, it is not too much to say that structural rigidity and strength of spot-welded structures is decided by fatigue strength of spot welded lap joint. Thus, it is necessary to establish a reasonable and systematic long life design criterion for the spot-welded structure. In this study, numerical stress analysis was performed by using 3-dimensional finite element model on IB-type spot-welded lap joint of 304 stainless steel sheet under tension-shear load. Fatigue tests were also conducted on them having various thickness, joint angle, lapped length, and width of the plate. From the results, it was found that fatigue strength of IB-type spot-welded lap joints was influenced by its geometrical factors, however, could be systematically rearranged by maximum principal stress ({TEX}$σ_{1max}${/TEX}) at the nugget edge of the spot-welding point.

  • PDF

Inflammability Characteristics and Wear Comfort Property of Modacrylic Composite Yarn and Knitted Fabrics (난연 모다크릴 복합 방적사 니트소재의 방염성과 착용쾌적특성)

  • Kim, Hyunah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.42 no.3
    • /
    • pp.397-410
    • /
    • 2018
  • This study investigated the flame retardant, anti-static property and wear comfort of knitted fabrics made of two kinds of composite yarns comprised of modacryl, antistatic PET, cotton and excel(R) fibers. A Low Oxygen Index (LOI) above 28 was observed in the modacryl knitted fabric specimens. The flame retardant was superior at the excel(R) fiber (including modacryl knitted fabric) than the one including cotton fiber. Anti-static properties of the modacryl knitted fabrics imbedded by 3wt% of antistatic PET fibers were observed by rubbing with wool fabric attached to the measuring apparatus, which showed a better anti-static property than the excel(R) fiber (including modacryl knitted fabric). Wear comfort indicated that quick perspiration absorption and the fast dry property of excel(R) (including modacryl knitted fabric) was better than one that included cotton fiber. Warmth keepability and breathability of the knitted fabrics indicated good results in the excel(R) (including cotton and the modacryl knitted fabrics). However, the tactile hand property of cotton fiber (including modacryl knitted fabric) was better than excel(R) fiber due to high extensibility and compressibility, and low bending and shear rigidity of the cotton fiber (including modacryl knitted fabrics).

In-Structure Response Spectra of Seismically Isolated Shear Buildings Considering Eccentricity Effect (면진된 전단 거동 구조물의 층응답스펙트럼에 대한 편심효과)

  • Lee, Seung Jae;Kim, Jung Han
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • For important structures such as nuclear power plants, In-Structure Response Spectrum (ISRS) analysis is essential because it evaluates the safety of equipment and components installed in the structure. Because most structures are asymmetric, the response can be affected by eccentricity. In the case of seismically isolated structures, this effect can be greater due to the difference between the center of mass of the structure and the center of rigidity of the isolator layer. Therefore, eccentricity effects must be considered when designing or evaluating the ISRS of seismically isolated structures. This study investigated the change of the ISRS of an isolated structure by assuming accidental eccentricity. The variables that affect the ISRS of the isolated structure were analyzed to see what additional impact they had due to eccentricity. The ISRS of the seismically isolated structure with eccentricity was amplified more than when there was non-eccentricity, and it was boosted more significantly in specific period ranges depending on the isolator's initial stiffness and seismic intensity. Finally, whether the displacement requirement of isolators can be applied to the variation of the ISRS due to eccentricity in the design code was also examined.

Inelastic Time History Analysis of a Five-Story Steel Framed Structure Considering Rigidity of TSD Connection (TSD 접합부의 강성을 고려한 5층 철골골조구조물의 비탄성 시간이력해석)

  • Kang, Suk-Bong;Lee, Jae-Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.3
    • /
    • pp.281-291
    • /
    • 2010
  • In this study, a five-story steel frame was designed in accordance with KBC2005 to evaluate the effects of the beam-column connection on the structural behavior. The connections were designed as fully rigid and semi-rigid. The fiber model was used to describe the moment-curvature relationship of the steel beam and the column, the power model for the moment-rotation angle of the semi-rigid connection and the three-parameter model for the hysteretic behavior of the steel beam, column, and connection. The structure was idealized as separate 2-D frames and as connected 2-D frames. The peak ground accelerations of four earthquake records were modified in a time-history analysis for the levels of the mean return period and for the maximum base-shear force in a pushover analysis. The top story displacement, base-shear force, story drift, demanded ductility ratio for the semi-rigid connection, maximum bending moment of the column, beam, and connection, and distribution of the plastic hinge were examined in the time-history analysis. The frame with the semi-rigid connection yielded a lower base-shear force, less magnitude, and increasing ratio in the bending moment of the column, beam, and connection than the frame with a fully rigid connection. The TSD connection was deemed to have secured the economy and safety of the sample structure that was subjected to seismic excitation for the Korean design level.

Investigation of Post-seismic Sites Using Local Seismic Tomography in the Korean Peninsula (지진 토모그래피를 이용한 한반도의 과거진원지역의 특성 연구)

  • Kim So-Gu;Bae Hyung-Sub
    • Economic and Environmental Geology
    • /
    • v.39 no.2 s.177
    • /
    • pp.111-128
    • /
    • 2006
  • Three dimensional crustal structure and source features of earthquake hypocenters on the Korean peninsula were investigated using P and S-wave travel time tomography. The main goal of this research was to find Vp/Vs anomalies at earthquake hypocenters as well as those of crustal structure of basins and deep tectonic settings. This allowed fer the extrapolation of more detailed seismotectonic force from the Korean peninsula. The earthquake hypocenters were found to have high Vp/Vs ratio discrepancies (VRD) at the vertical sections. High V/p/Vs ratios were also found in the sedimentary basins and beneath the Chugaryong Rift Zone (CRZ), which was due to mantle plume that subsequently solidified with many fractures and faults which were saturated with connate water. The hypocenters of most earthquakes were found in the upper crust for Youngwol (YE), Kyongju (KE), Hongsung (HE), Kaesong (KSE), Daekwan (DKE), and Daehung (DHE) earthquakes, but near the subcrust or the Moho Discontinuity for Mt. Songni (SE), Sariwon (SRE) and Mt. Jiri (JE) earthquakes. Especially, we found hot springs of the Daekwan, Daehung and Unsan regions coincide with high VRD. Also, this cannot rule out the possibility that there are some partial meltings in the subcrust of this region. High VRD might indicate that many faults and fractures with connate water were dehydrated when earthquakes took place, reducing shear modulus in the hypocenter areas. This is can be explained by due to the fact that a point source which is represented by the moment tensor that may involve changes in volume, shear fracture, and rigidity. High Vp/Vs ratio discrepancies (VRD) were also found beneath Mt. Backdu beneath 40 km, indicating that magma chamber existed beneath Mt. Backdu is reducing shear modulus of S-wave velocity.

Flexural Strengthening of Reinforced Concrete Beams Using Carbon Fiber Mesh (탄소섬유 메쉬를 사용한 철근콘크리트 보의 휨보강)

  • Seo, Soo-Yeon;Yun, Hyun-Do;Choi, Chang-Sik;Choi, Ki-Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.2
    • /
    • pp.181-190
    • /
    • 2005
  • The objective of this work is to study the flexural strengthening effectiveness of Carbon Fiber Mesh (CFM) in reinforced concrete beams. Flexural strengthening for a simply supported reinforced concrete (RC) beam using CFM is developed by bonding CFM to the soffit of the beam. In this experimental program, five medium-sized reinforced concrete beams strengthened with CFM are tested in bending to evaluate reinforcing effects of the CFM. The beams are designed to have high shear capacity so that expected dominant failure mode of specimens is bending. The reinforcing effect of CFM is small at crack initiation, but is considerable in flexural rigidity of the beam after crack initiation. In comparing the behaviors of strengthened and virgin beams each other, it is shown that the strength of RC beams can be enhanced by attaching CFM. A fairly good agreement between the measured values and the calculated ones is obtained at both the cracking strength and yield strength of the strengthened beams.

Degumming Characteristics and Fabric Properties by Papain Degumming (파파인효소의 정련특성과 정련견의 성질)

  • 김정희;남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.29 no.2
    • /
    • pp.58-66
    • /
    • 1987
  • This study was investigated on the effect of degumming of cocoon shell, raw silk yarn and grey silk crepe by use of Papain, comparing with soap, soda and soap-soda. The obtained results may be summarized as follows : 1. Degumming loss, when the pretreatment was done, was completed by Papain more than by alkali. 2. Lousiness result of Papain degummed silk yarn was apt to be improved more than that of alkali degummed one. 3. As a result of tensile property test, elasticity and resilience of Papain degummed crepe were good compared to those of alkali degummed one. 4. Not only bending rigidity of Papain degummed crepe was reduced more than that of alkali degummed one but also hysteresis of bending moment was decreased in papain degummed crepe. 5. Handle of Papain degummed crepe was superior to that of alkali degummed one.

  • PDF

Effect of Wet and Dry Thermal Setting Conditions of Stretch Fabric to Fabric Mechanical Property and Garment Formability (습·건열 열고정 조건이 스트레치 직물의 역학특성과 의류형성성능에 미치는 영향)

  • Kim, Hyun-Ah;Kim, Seung-Jin
    • Fashion & Textile Research Journal
    • /
    • v.20 no.1
    • /
    • pp.83-92
    • /
    • 2018
  • This paper investigated garment formability and fabric mechanical properties of one-way and two-way stretch fabrics according to the thermal treatment methods. One-way and two-way stretch fabrics were woven using 75d and 150d PET/spandex covering yarns and then these were wet thermal treated with four kinds of finishing machines. The fabric mechanical properties of these stretch fabrics specimens were measured and compared with the regular PET fabrics. The stretch ratio of one-way stretch fabric was ranged 12 to 26 percentage, 15 to 45 percentage for 2-way stretch fabrics and 4 to 10 percentage for regular fabrics. Garment formability of stretch fabric was superior than that of regular fabrics, in addition, 2-way stretch fabric was better than one-way. The garment formability of the stretch fabrics treated with CPB and Lava wet thermal machines showed the highest values, and the stretch ratio of these 2-way stretch fabrics was also the highest, which was ranged 20 to 45 percentage. This phenomenon was assumed to be due to high extensibility and bending rigidity with low shear modulus of the 2-way stretch fabric treated with CPB and Lava wet thermal machines. It was shown that the garment formability of stretch fabrics treated without dry thermal treatment was higher than that of dry thermal treated fabrics. It revealed that high stretch fabric was available under the condition of low process tension in the wet and dry thermal treatments of the finishing process, which makes high garment formability.

A Study on the Mechanical Properties of Fabrics for Korean Folk Clothes (Part 3) On the core-spun yarn woven fabrics (한복지의 역학적특성에 관한 연구 (제3보) 코어방적계 한복지)

  • Sung Su-Kwang;Kwon Oh-Kyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.13 no.1 s.29
    • /
    • pp.79-87
    • /
    • 1989
  • In the part 1 and 2, relations were found between fundmental mechanical properties and primary hand values, performance of Korean women's summer and fall & winter fabrics. In this paper, in order to investigate the hand values and mechanical properties such as tensile, shearing, bending, compression, surface and thickness & weight of the core-spun yarn woven fabrics for Korean folk clothes were measured by KES-F system. The experimental results are statistically analyzed in the aspects of the mechanical properties, their effects on the hand values, formation of weared clothes and transformation behavior. The correlation in the hand values are analyzed, too. Furthermore, there mechanical properties are discussed in comparison with those values for kimono fabrics. The main results are summarized as follows: 1. The core-spun yarn woven fabrics for Korean folk clothes have box-shaped silhouette based on higher bending rigidity and shear elasticity. 2. The core-spun yarn woven fabrics for Korean folk clothes are inferior to silk fabrics, superior to polyester fabrics in formation. 3. A drapability and wrinkle recovery of core-spun yarn woven fabrics for Korean folk clothes formation for weared clothes are inferior to polyester fabrics, superior to silk fabrics. 4. A primary factor of mechanical properties contribute to the hand values of core-spun yarn woven fabrics for Korean folk clothes are same as the Korean women's winter fabrics, except for flexibility with soft feeling. 5. As for the hand values of core-spun yarn woven fabrics for Korean folk clothes, stiffness, anti-drape stiffness are superior to those of polyester fabrics. And also, flexibility with soft feeling, scrooping feeling of core-spun yarn woven fabrics have greater values as compared with silk fabrics for Korean folk clothes.

  • PDF

Behavior of semi-rigid steel frames under near- and far-field earthquakes

  • Sharma, Vijay;Shrimali, Mahendra K.;Bharti, Shiv D.;Datta, Tushar K.
    • Steel and Composite Structures
    • /
    • v.34 no.5
    • /
    • pp.625-641
    • /
    • 2020
  • The realistic modeling of the beam-column semi-rigid connection in steel frames attracted the attention of many researchers in the past for the seismic analysis of semi-rigid frames. Comparatively less studies have been made to investigate the behavior of steel frames with semi-rigid connections under different types of earthquake. Herein, the seismic behavior of semi-rigid steel frames is investigated under both far and near-field earthquakes. The semi-rigid connection is modeled by the multilinear plastic link element consisting of rotational springs. The kinematic hysteresis model is used to define the dynamic behavior of the rotational spring, describing the nonlinearity of the semi-rigid connection as defined in SAP2000. The nonlinear time history analysis (NTHA) is performed to obtain response time histories of the frame under scaled earthquakes at three PGA levels denoting the low, medium and high-level earthquakes. The other important parameters varied are the stiffness and strength parameters of the connections, defining the degree of semi-rigidity. For studying the behavior of the semi-rigid frame, a large number of seismic demand parameters are considered. The benchmark for comparison is taken as those of the corresponding rigid frame. Two different frames, namely, a five-story frame and a ten-story frame are considered as the numerical examples. It is shown that semi-rigid frames prove to be effective and beneficial in resisting the seismic forces for near-field earthquakes (PGA ≈ 0.2g), especially in reducing the base shear to a considerable extent for the moderate level of earthquake. Further, the semi-rigid frame with a relatively weaker beam and less connection stiffness may withstand a moderately strong earthquake without having much damage in the beams.