Research on Turbulent Skin Friction Reduction with the aid of Direct Numerical Simulation

  • Fukagata, Koji
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.347-354
    • /
    • 2008
  • We introduce a series of studies on turbulent skin friction drag reduction in wall-turbulence. First, an identity equation relating the skin friction drag and the Reynolds shear stress (the FIK identity) is introduced. Based on the implication of the FIK identity, a new analytical suboptimal feedback control law requiring the streamwise wall-shear stress only is introduced and direct numerical simulation (DNS) results of turbulent pipe flow with that control is reported. We also introduce DNS of an anisotropic compliant surface and parameter optimization using an evolutionary optimization technique.

  • PDF

Research on Turbulent Skin Friction Reduction with the aid of Direct Numerical Simulation

  • Fukagata, Koji
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.347-354
    • /
    • 2008
  • We introduce a series of studies on turbulent skin friction drag reduction in wall-turbulence. First, an identity equation relating the skin friction drag and the Reynolds shear stress (the FIK identity) is introduced. Based on the implication of the FIK identity, a new analytical suboptimal feedback control law requiring the streamwise wall-shear stress only is introduced and direct numerical simulation (DNS) results of turbulent pipe flow with that control is reported. We also introduce DNS of an anisotropic compliant surface and parameter optimization using an evolutionary optimization technique.

  • PDF

A Study on the Flow Path Position Design of Waviness Friction Pad for Drag Torque Reduction in Wet Type DCT (파형 습식클러치의 드래그 토크 저감을 위한 파형내 유로 위치 설정 설계 연구)

  • Cho, Junghee;Han, Juneyeol;Kim, Woojung;Jang, Siyoul
    • Tribology and Lubricants
    • /
    • v.33 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Drag torque reduction in a wet clutch pack is a key aspect of the design process of the dual clutch transmission (DCT) system. In order to reduce the drag torque caused by lubricant shear resistance, recently developed wet clutch pack systems of DCT, as well as automatic transmission and other four-wheel drive (4WD) couplings, frequently utilize wavy wet clutch pads. Therefore, wavy shape of friction pad are made on the groove patterns like waffle pattern for the reduction of drag torque. Additionally, the groove patterns are designed with larger channels at several locations on the friction pad to facilitate faster outflow of lubricant. However, channel performance is a function of the waviness of the friction pad at the location of the particular channel. This is because the discharge sectional area varies according to the waviness amplitude at the location of the particular channel. The higher location of the additional channel on the friction pad results in a larger cross-sectional area, which allows for a larger flow discharge rate. This results in reduction of the drag torque caused by the shear resistance of DCTF, because of marginal volume fraction of fluid (VOF) in the space between the friction pad and separator. This study computes the VOF in the space between the friction pad and separator, the hydrodynamic pressure developed, and the shear resistance of friction torque, by using CFD software (FLUENT). In addition, the study investigates the dependence of these parameters on the location and waviness amplitude of the channel pattern on the friction pad. The paper presents design guidelines on the proper location of high waviness amplitude on wavy friction pads.

Estimation of Shear Strength and Rheological Parameters of Fine-Grained Soil Using Direct Shear Test (직접전단실험을 이용한 세립토의 전단강도 및 유변학적 정수 산정)

  • Park, Geun-Woo;Hong, Won-Taek;Lee, Jong-Sub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.2
    • /
    • pp.29-37
    • /
    • 2017
  • As the behavior of the debris flow due to the torrential rains in mountain is affected by shear strength and rheological properties of the fine fraction in the ground, the evaluation of both properties is necessary to estimate the behavior of the debris flow. The objective of this study is to evaluate the shear strength and rheological properties using the direct shear apparatus. The direct shear tests are conducted for two kinds of fine-grained soil specimens, which are in dry state and liquid limit state. From the direct shear tests, shear strengths are measured according to the normal stresses applied on the specimens to evaluate the cohesion and internal friction angle. In addition, reversal shear tests are performed for the fine-grained soil specimens in liquid limit state according to the shear rate to evaluate the residual shear strength. The results of direct shear tests show that the specimen at the liquid limit state has lower internal friction angle and higher cohesion compared to the dry stated, and the residual friction angle and cohesion at the residual state are lower than those at the peak state. In the result of reversal shear test, the residual shear strength is directly proportional to the shear rate and viscosity is calculated as $73.60Pa{\cdot}s$. This study demonstrates that the direct shear apparatus can be effectively used for the evaluation of the shear strength and rheological properties of the fine-grained soils related with the debris flow.

Interface Shear Strength Between Soil and Woven Geotextile (흙-직포간의 접촉면 전단강도 산정)

  • Youn, Choo-Moon;An, Hyun-Ho;Seo, Byoung-Wook;Lee, Seok-Won
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.3
    • /
    • pp.25-30
    • /
    • 2006
  • Large-scale direct shear tests were conducted in order to evaluate both the shear strength of soil itself and the interface shear strength between soil and woven geotextile. Two types of soil (sand and clay) with a woven geotextile were used in the experimental program. Total nine tests were conducted in this study. It has been found from the experimental results that the friction angle of sand itself were $30^{\circ}$. Interface friction angle between woven geotextile and sand showed $26^{\circ}$ indicating an efficiency of 87%. Similarly, interface friction angle between woven geotextile and clay showed $7.7^{\circ}$.

  • PDF

Analyses of Shear and Frictional Characteristics in Drilling Process (드릴링 공정의 전단 및 마찰 특성 해석)

  • Kim, Sun-Il;Choi, Won-Sik;Son, Jae-Hwan;Jang, Eun-Suk;Lee, Young-Moon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.22-27
    • /
    • 2012
  • Drilling process is usually the most efficient and economical method of making a hole in a solid body. However, there have been no analytical method to assess drilling process based on the shear and frictional characteristics. In this paper, procedures for analyzing shear and frictional processes of drilling have been established by adopting an equivalent turning system to drilling. A series of drilling experiments were carried out with varying feed, velocity and drill shape factors. Using the results of the experiments, the cutting characteristics including shear in the primary shear zone and friction in the chip-tool contact region of drilling process have been analyzed. The specific cutting energy tends to decrease exponentially with increase of feed rate. In drilling process 35-40% of the total energy is consumed in the friction process. This is greater than that of turning process in cutting of the same work material.

Push-out tests on demountable high-strength friction-grip bolt shear connectors in steel-precast UHPC composite beams for accelerated bridge construction

  • Haibo, Jiang;Haozhen, Fang;Jinpeng, Wu;Zhuangcheng, Fang;Shu, Fang;Gongfa, Chen
    • Steel and Composite Structures
    • /
    • v.45 no.6
    • /
    • pp.797-818
    • /
    • 2022
  • Steel-precast ultra-high-performance concrete (UHPC) composite beams with demountable high-strength friction-grip bolt (HSFGB) shear connectors can be used for accelerated bridge construction (ABC) and achieve excellent structural performance, which is expected to be dismantled and recycled at the end of the service life. However, no investigation focuses on the demountability and reusability of such composite beams, as well as the installation difficulties during construction. To address this issue, this study conducted twelve push-out tests to investigate the effects of assembly condition, bolt grade, bolt-hole clearance, infilling grout and pretension on the crack pattern, failure mode, load-slip/uplift relationship, and the structural performance in terms of ultimate shear strength, friction resistance, shear stiffness and slip capacity. The experimental results demonstrated that the presented composite beams exhibited favorable demountability and reusability, in which no significant reduction in strength (less than 3%) and stiffness (less than 5%), but a slight improvement in ductility was observed for the reassembled specimens. Employing oversized preformed holes could ease the fabrication and installation process, yet led to a considerable degradation in both strength and stiffness. With filling the oversized holes with grout, an effective enhancement of the strength and stiffness can be achieved, while causing a difficulty in the demounting of shear connectors. On the basis of the experimental results, more accurate formulations, which considered the effect of bolt-hole clearance, were proposed to predict the shear strength as well as the load-slip relationship of HSFGBs in steel-precast UHPC composite beams.

Vibration Control of Shear Wall-Frame System using Energy Dissipation Devices (에너지 소산형 감쇠기를 이용한 철근콘크리트 전단벽-골조 시스템의 진동제어)

  • Park, Ji-Hun;Kim, Gil-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.578-581
    • /
    • 2007
  • In this study, the seismic control performance of energy dissipation devices installed in a shear all-frame structure is investigated through nonlinear time history analysis of a 12-story building. Inelastic shear walls are modeled using the multiple vertical line element model (MVLEM) and inelastic columns and girders were modeled using fiber beam elements. For a seismic load increased by 38% compared to the design load, the seismic control performance was analyzed based on the results of a nonlinear time history analysis in terms of the inter-story drift, the story shear and the flexural strain. Friction type dampers was found to performs best if they are installed in the form of a brace adjacent to the shear wall with the friction force of 15 % of the maximum story shear force induced in the original building structure without dampers.

  • PDF

Shear Resistance Capacity of Precast Post-tensioned Concrete Beam-Column Connection (프리캐스트 포스트텐션 콘크리트 보-기둥 접합부의 전단성능)

  • 조경호;이종규;최광호;김상식
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.769-774
    • /
    • 2000
  • The first thing in developing precast post-tensioned concrete frame system verify the shear resistance capacity of the beam-column connection at which the transfer of member forces become discontinuous. Complying with the necessity of such experimental research, shear tests have been performed for six test specimens which were cast and cured at Dong-Ah Concrete Manufacturing Company and post-tensioning at Concrete Laboratory of Inha University. Shear key and magnitude of post-tensioned force are taken test variables. From the test results, it has been observed that the shear resistance of the specimens attained to higher values than those of theoritical calculations based on the shear friction with shear friction coefficient being 0.6.

  • PDF

Analytical Study on Behavior Characteristic of Shear Friction on Reinforced Concrete Shear Wall-Foundation Interface using High-Strength Reinforcing Bar (고강도 전단철근을 사용한 철근콘크리트 전단벽체-기초계면에서의 전단마찰 거동특성에 대한 해석적 연구)

  • Cheon, Ju-Hyun;Lee, Ki-Ho;Baek, Jang-Woon;Park, Hong-Gun;Shin, Hyun-Mock
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.4
    • /
    • pp.473-480
    • /
    • 2016
  • The purpose of this study is to provide analytical method to reasonably evaluate the complicated failure behaviors of shear friction of reinforced concrete shear wall specimens using grade 500 MPa high-strength bars. A total of 16 test specimens with a variety of variables such as aspect ratio, friction coefficient of interface in construction joint, reinforcement details, reinforcement ratio in each direction, material properties were selected and the analysis was performed by using a non-linear finite element analysis program (RCAHEST) applying the modified shear friction constitutive equation in interface based on the concrete design code (KCI, 2012) and CEB-FIP Model code 2010. The mean and coefficient of variation for maximum load from the experiment and analysis results was predicted 1.04 and 17% respectively and properly evaluated failure mode and overall behavior characteristic until failure occur. Based on the results, the analysis program that was applied modified shear friction constitutive equation is judged as having a relatively high reliability for the analysis results.