• 제목/요약/키워드: shear effect

검색결과 4,319건 처리시간 0.036초

섬유혼합 보강토의 전단강도특성 및 마찰특성 연구 (A Study on Shear strength and Friction Properties of Fiber-Mixed Soil as Backfill Material in Reinforced Earth Wall)

  • 조삼덕;김진만;안주환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.651-658
    • /
    • 2002
  • A series of experimental study are performed to evaluate the shear strength and friction properties of fiber-mixed soil as backfill material in reinforced earth wall. In order to evaluate the properties of shear strength the big-size direct shear tests are carried out and on the friction properties, the shear friction tests and the pull-out tests are performed. In the results, when the mixed ratio of the net type fiber is 0.2%, the reinforcement effect was better than the others. Also the reinforcement effect of the net type fiber was larger than that of the line type fiber.

  • PDF

균열 및 비균열 철근콘크리트 기둥의 탄소섬유시트 전단보강효과에 관한 실험적 연구 (Experimental Study on the Shear Strengthening Effect of Cracked or Uncracked RC Columns with Carbon Fiber Sheets)

  • 나정민;이용택;김승훈;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권4호
    • /
    • pp.243-254
    • /
    • 2002
  • This study investigates the structural behavior of cracked or uncracked RC columns retrofitted with CFS and evaluates the shear retrofit performance through experiment. Experimental works were conducted for sixth specimens varied in the adhesion method of CFS, the ratio of shear reinforcement bar, and the existence of crack before retrofitting. Throughout cyclic test, the strength, stiffness, failure modes, and ductility are discussed. The test results show that the retrofitting method with CFS improve the shear strength and ductility. The crack width below 2mm, occurred before retrofitting, didn't reduce the shear strengthening effect.

바텀애시 골재 기반 경량 콘크리트의 전단마찰거동에 대한 기포 혼입률의 영향 (The effect of Foam Volume Ratio on the Shear Friction Behavior of Bottom Ash Based Lightweight Aggregate Concrete)

  • 김종원;양근혁;문주현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.183-184
    • /
    • 2020
  • This study evaluated the effect of foam volume ratio on shear friction behavior of bottom ash based lightweight aggregate concrete (LWA_BA). The LWA_BA with different foam volume ratio ranged between 8 and 25 MPa for compressive strength(fck), 17.3~62.5 kN for shear capacity at first shear crack(Vcr), 31.1~73.8 kN for shear friction capacity(Vn), and 0.01~0.03 mm for slip at maximum peak load(S0). fck decreased with increase in the foam volume ratio, showing that this trend was also observed in Vcr, Vn, and S0.

  • PDF

Comparison of behavior of high-rise residential buildings with and without post-tensioned transfer plate system

  • Byeonguk Ahn;Fahimeh Yavartanoo;Jang-Keun Yoon;Su-Min Kang;Seungjun Kim;Thomas H.-K. Kang
    • Computers and Concrete
    • /
    • 제31권4호
    • /
    • pp.337-348
    • /
    • 2023
  • Shear wall is commonly used as a lateral force resisting system of concrete mid-rise and high-rise buildings, but it brings challenges in providing relatively large space throughout the building height. For this reason, the structure system where the upper structure with bearing, non-bearing and/or shear walls that sits on top of a transfer plate system supported by widely spaced columns at the lower stories is preferred in some regions, particularly in low to moderate seismic regions in Asia. A thick reinforced concrete (RC) plate has often been used as a transfer system, along with RC transfer girders; however, the RC plate becomes very thick for tall buildings. Applying the post-tensioning (PT) technique to RC plates can effectively reduce the thickness and reinforcement as an economical design method. Currently, a simplified model is used for numerical modeling of PT transfer plate, which does not consider the interaction of the plate and the upper structure. To observe the actual behavior of PT transfer plate under seismic loads, it is necessary to model whole parts of the structure and tendons to precisely include the interaction and the secondary effect of PT tendons in the results. This research evaluated the seismic behavior of shear wall-type residential buildings with PT transfer plates for the condition that PT tendons are included or excluded in the modeling. Three-dimensional finite element models were developed, which includes prestressing tendon elements, and response spectrum analyses were carried out to evaluate seismic forces. Two buildings with flat-shape and L-shape plans were considered, and design forces of shear walls and transfer columns for a system with and without PT tendons were compared. The results showed that, in some cases, excluding PT tendons from the model leads to an unrealistic estimation of the demands for shear walls sit on transfer plate and transfer columns due to excluding the secondary effect of PT tendons. Based on the results, generally, the secondary effect reduces shear force demand and axial-flexural demands of transfer columns but increases the shear force demand of shear walls. The results of this study suggested that, in addition to the effect of PT on the resistance of transfer plate, it is necessary to include PT tendons in the modeling to consider its effect on force demand.

Shear Tests for Ultra-High Performance Fiber Reinforced Concrete (UHPFRC) Beams with Shear Reinforcement

  • Lim, Woo-Young;Hong, Sung-Gul
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권2호
    • /
    • pp.177-188
    • /
    • 2016
  • One of the primary concerns about the design aspects is that how to deal with the shear reinforcement in the ultra-high performance fiber reinforced concrete (UHPFRC) beam. This study aims to investigate the shear behavior of UHPFRC rectangular cross sectional beams with fiber volume fraction of 1.5 % considering a spacing of shear reinforcement. Shear tests for simply supported UHPFRC beams were performed. Test results showed that the steel fibers substantially improved of the shear resistance of the UHPFRC beams. Also, shear reinforcement had a synergetic effect on enhancement of ductility. Even though the spacing of shear reinforcement exceeds the spacing limit recommended by current design codes (ACI 318-14), shear strength of UHPFRC beam was noticeably greater than current design codes. Therefore, the spacing limit of 0.75d can be allowed for UHPFRC beams.

정규압밀점토의 강성도와 전단강도의 상관관계 (Relationship Between Stiffness And Shear Strength of Normally Consolidated Clays)

  • 박치원;박동선;목영진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.402-413
    • /
    • 2006
  • Strength evaluation of soft soils is a formidable task because of difficulties in sampling, specimen preparation and setting in triaxial cells. In undrained triaxial testing, sampling disturbance, verticality of specimen and bedding effect give a great influence on shear strength measurements. In the other hand, shear wave measurements of specimens are less influenced by these factors. In this research, the bender elements were attached top cap and base pedestal of triaxial cell and shear wave velocities were measured. To initiate a methodology to evaluate shear strength indirectly by measuring shear wave velocity, a relationship between shear strength and shear wave velocity was developed with kaolinite specimens consolidated in the laboratory. Undrained shear strength turns out to increase linearly with shear wave velocity. Stress-strain curves can also be predicted with a hyperbolic model and shear wave measurements.

  • PDF

콘크리트의 전단마찰 내력에 대한 횡보강근 및 압축응력의 영향 (Effect of Shear Reinforcement and Compressive Stress on the Shear Friction Strength of Concrete)

  • 황용하;양근혁
    • 콘크리트학회논문집
    • /
    • 제28권4호
    • /
    • pp.419-426
    • /
    • 2016
  • 이 연구에서는 다양한 콘크리트를 갖는 전단계면에서의 전단마찰거동에 대한 횡보강근 및 압축응력의 영향을 평가하였다. 12개 직접전단실험체로부터 균열진전, 전단하중-상대 미끄러짐 관계, 균열발생시 전단응력, 최대전단내력 및 횡보강근의 전단저항력 등이 측정되었다. 실험결과 동일 전단하중에서 상대 미끄러짐 제어에 대한 횡보강근 배근형상 및 콘크리트 압축강도의 영향은 미미하였다. 작용 압축응력의 증가와 함께 콘크리트의 전단전달력을 증가하는 반면, 횡보강근의 전단전달력은 감소하였는데, 횡보강근의 전단저항은 배근형태에 의해 영향을 받지 않았다. AASHTO-LRFD, Mattock 및 Hwang and Yang의 모델은 콘크리트의 전단마찰내력을 과소평가하였다. 반면, Hwang and Yang의 모델은 실험결과와의 비교에 대한 평균과 표준편차 값이 각각 1.02과 0.23으로서 기존 모델에 비해 다양한 변수의 영향을 적절히 고려하면서 콘크리트의 전단마찰내력을 잘 예측하였다.

전단철근비와 보의 단면크기에 따른 철근콘크리트 보의 전단강도 특성 연구 (A Characteristic Study on Shear Strength of Reinforced Concrete Beams according to Shear Reinforcement Ratio and Beam Section Size)

  • 노형진;유인근;이호경;백승민;김우석;곽윤근
    • 대한건축학회논문집:구조계
    • /
    • 제35권6호
    • /
    • pp.111-119
    • /
    • 2019
  • The purpose of this study is to investigate the shear strength of reinforced concrete beam according to beam section size and shear reinforcement ratio. A total of nine specimens were tested and designed concrete compressive strength is 24 MPa. The main variables are shear reinforcement ratio and beam section size fixed with shear span to depth ratio (a/d = 2.5), the tensile reinforcement ratio (${\rho}=0.013$) and width to depth ratio (h/b = 1.5). The test specimens were divided into three series of S1 ($225{\times}338mm$), S2 ($270{\times}405mm$) and S3 ($315{\times}473mm$), respectively. The experimental results show that all specimens represent diagonal tensile failure. For $S^*-1$ specimens (d/s=0), the shear strength decreased by 33% and 46% with increasing the beam effective depth, 26% and 33% for $S^*-2$ specimens (d/s=1.5) and 16% and 20% for $S^*-3$ specimens (d/s=2.0) respectively. As the shear reinforcement ratio increases, the decrease range in shear strength decreases. In other words, this means that as the shear reinforcement ratio increases, the size effect of concrete decreases. In the S1 series, the shear strength increased by 39% and 41% as the shear reinforcement ratio increased, 54% and 76% in the S2 series and 66% and 100% in the S3 series, respectively. As the effective depth of beam increases, the increase range of shear strength increases. This means that the effect of shear reinforcement increases as the beam effective depth increases. As a result of comparing experimental values with theoretical values by standard equation and proposed equation, the ratio by Zsutty and Bazant's equation is 1.30 ~ 1.36 and the ratio by KBC1 and KBC2 is 1.55~.163, respectively. Therefore, Zsutty and Bazant's proposed equation is more likely to reflect the experimental data. The current standard for shear reinforcement ratio (i.e., $S_{max}=d/2$) is expected to be somewhat relaxed because the ratio of experimental values to theoretical values was found to be 1.01 ~ 1.44 for most specimens.

A new higher order shear and normal deformation theory for functionally graded beams

  • Meradjah, Mustapha;Kaci, Abdelhakim;Houari, Mohammed Sid Ahmed;Tounsi, Abdelouahed;Mahmoud, S.R.
    • Steel and Composite Structures
    • /
    • 제18권3호
    • /
    • pp.793-809
    • /
    • 2015
  • In this scientific work, constructing of a novel shear deformation beam model including the stretching effect is of concern for flexural and free vibration responses of functionally graded beams. The particularity of this model is that, in addition to considering the transverse shear deformation and the stretching effect, the zero transverse shear stress condition on the beam surface is assured without introducing the shear correction parameter. By employing the Hamilton's principle together with the concept of the neutral axe's position for such beams, the equations of motion are obtained. Some examples are performed to demonstrate the effects of changing gradients, thickness stretching, and thickness to length ratios on the bending and vibration of functionally graded beams.

구조적 손상을 입은 철근콘크리트 보의 전단보강 효과에 관한 연구 (A Study on the Shear Strengthening Effect of Reinforced Concrete Beams with Structural Damage)

  • 신용석;김정훈;김정섭;김광석;조철희
    • 한국건축시공학회지
    • /
    • 제8권5호
    • /
    • pp.43-51
    • /
    • 2008
  • This study examines shear capacity performance and structural characteristics of reinforced concrete beam using carbon fiber sheet(CFS), g)ass fiber sheet(GFS), glass fiber steel plate(GSP) and carbon fiber bar CB) which are reinforcing materials for reinforced concrete beam in order to produce similar condition to repair and reinforce actual structure and aims to provide data available In designing and constructing reinforced concrete structures under the structural damage. This study obtains the following conclusions. After considering the shear experiment results. it was indicated that the CB reinforced test object was the best in the shear capacity improvement and ductility capacity as it was contained in the concrete and was all operated, Also, GFS reinforced test object indicated the reduced flexural capacity but good shear capacity. GSP reinforced test object had bigger reinforcing strength than other reinforcing test objects. On the other hand, it showed the lowest reinforcement effect as compared section thickness of reinforced material because it showed the bigger relativity a section thickness of reinforced material. If the adherence to the concrete is improved, it will seem to show bigger reinforcement effect.