Micromirrors supported by S-shape girders were fabricated and their angular deflections were measured using a laser-based system. A micromirror consists of a $50\mum\times50\mum$ aluminum plate, posts and an S-shape girder. Two electrodes were deposited on two corners of the substrate beneath the mirror plate. $50\times50$micromirror array were fabricated using the Al-MEMS process. The electrostatic force caused by the voltage difference between the mirror plate and one of the electrodes causes the mirror plate to tilt until the girder touches the substrate. Bial voltage of the mirror plate is between 25~35V and signal pulse voltage on both electrodes is $\pm5V$. A laser-based system capable of real-time two-dimensional angular deflection measurement of the micromirror was developed. The operation of the system is based on measuring the displacement of a HeNe laser beam reflecting off the micromirror. The resonant frequency of the micromirror is 50kHz when the girder touches the substrate and it is 25 when the micromirror goes back to flat position, since the moving mass is about twice of the former case. The measurement results also revealed that the micromirror slants to the other direction even after the girder touches the substrate.
This paper proposes a compact-sized surface myoelectric sensor for myoelectric hand prosthesis. To fit the surface myoelectric sensor in the socket of the myoelectric hand prosthesis, the sensor should be a compact size. The surface myoelectric sensor is composed of a skin interface and a single processing circuit that are mounted on a single package. Since the skin interface has one reference and two input electrodes, and the reference electrode is located in middle of two input electrodes, we propose two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material used for the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering conduction velocity and median frequency of the myoelectric signal, we select the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22 mm. The signal processing circuit consists of a differential amplifier with band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value circuit. We evaluate the proposed sensor from the output characteristics according to the IED and the shape of the reference electrode. From the experimental results we show the surface myoelectric sensor with the 18mm IED and the bar-shaped reference electrode is suitable for the myoelectric hand prosthesis.
This paper presents the potential interferences in various grounding electrode systems. The ground potential rise and potential interference coefficients were calculated as a function of the configuration and size of grounding electrodes and the distance between grounding electrodes. The potential rise and potential interference coefficient strongly depend on the distance between grounding electrodes, the shape and size of grounding electrodes.
Recently, there are many equipment of electricity, electronics, and communication which need to grounding in the building. When the electric current flows into a certain grounding system in the same building, the potential rise of other grounding system is possible to be affected by its potential rise. This potential interference was affected by the surface potential, it is deeply related whit the electrode shape. In this paper, basic formula is deduced on the basis of both electrodes surface potential of grounding electrode in a source of the potential interference and groundidng electrode which receive the potential interference. Therefore the degree of potential interference as multiple groundidng electrode can be verified the simulated results by means of the simple model in advance. This is for investigating the grounding resistance of grounding electrodes, the experiment was performed with model-scale of the grounding system and the scaled model grounding system was to this experiment using a water tank of a stainless steel-hemisphere shape. since mesh electrodes have been widely in the general building, we're tried to analyze that this water tank model and it's simulation as well.
Kim, Jinse;Park, Jong Woo;Park, Seokho;Choi, Dong Soo;Choi, Seung Ryul;Kim, Yong Hoon;Lee, Soo Jang;Park, Chun Wan;Han, Gui Jeung;Cho, Byoung-Kwan
Journal of Biosystems Engineering
/
제41권2호
/
pp.108-115
/
2016
Purpose: Radio frequency (RF) heating is a promising thawing method, but it frequently causes undesirable problems such as non-uniform heating. This can occur because of the food shape, component distribution, and initial temperature differences between food parts. In this study, RF heating was applied to the thawing of cylindrically shaped pork sirloin by changing the shape of electrodes and the surrounding temperature. Methods: Curved electrodes were utilized to increase the thawing uniformity of cylindrically shaped frozen meat. Pork sirloin in the shape of a half-circle column was frozen in a deep freezer at $-70^{\circ}C$ and then thawed by RF heating with flat and curved electrodes. In order to prevent fast defrosting of the food surface by heat transfer from air to the food, the temperature of the thawing chamber was varied by -5, -10, and $-20^{\circ}C$. The temperature values of the frozen pork sirloin during RF thawing were measured using fiber-optic thermo sensors. Results: After multiple applications of curved electrodes resembling the food shape, and a cooled chamber at $-20^{\circ}C$ the half-cylindrically shaped meat was thawed without surface burning, and the temperature values of each point were similarly increased. However, with the parallel electrode, the frozen meat was partially burned by RF heating and the temperature values of center were overheated. The uniform heating rate and heat transfer prevention from air to the food were crucial factors for RF thawing. In this study, these crucial factors were accomplished by using a curved electrode and lowering the chamber temperature. Conclusions: The curved shape of the electrode and the equipotential surface calculated from the modeling of the parallel capacitor showed the effect of uniform heating of cylindrically shaped frozen food. Moreover, the low chamber temperature was effective on the prevention of the surface burning during RF thawing.
In this paper, we describe the development of a non-enzymatic glucose sensor based on copper nanocubes(Cu NCs) electroplated laser induced graphene(LIG) electrodes which can detect a certain range of glucose concentrations. $CO_2$ laser equipment was used to form LIG electrodes on the PI film. This fabrication method allows easy control of the LIG electrode size and shape. The Cu NCs were electrochemically deposited on the LIG electrodes to improve electron transfer rates and thus enhancing electrocatalytic reaction with glucose. The average sheet resistances before and after electroplating were $15.6{\Omega}/{\Box}$ and $19.6{\Omega}/{\Box}$, respectively, which confirmed that copper nanocubes were formed on the laser induced graphene electrodes. The prepared electrode was used to measure the current according to glucose concentration using an electrochemical method. The LIG electrodes with Cu NCs demonstrated a high degree of sensitivity ($1643.31{\mu}A/mM{\cdot}cm^2$), good stability with a linear response to glucose ranging from 0.05 mM to 1 mM concentration, and a limit of detection of 0.05 mM. In order to verify that these electrodes can be used as flexible devices, the electrodes were bent to $30^{\circ}$, $90^{\circ}$, and $180^{\circ}$ and cyclic voltammetry measurements were taken while the electrodes were bent. The measured data showed that the peak voltage was almost constant at 0.42 V and the signal was stable even in the flexed condition. Therefore, it is concluded that these electrodes can be used in flexible sensors for detecting glucose in the physiological sample like saliva, tear or sweat.
International Journal of Precision Engineering and Manufacturing
/
제9권2호
/
pp.23-27
/
2008
As a biofuel source, direct photosynthetic/metabolic biofuel cells (DPBFC) use cyanobacteria whose photosynthesis and metabolization reactions can convert light energy to electricity, In our previous work, we fabricated a prototype micro-DPBFC that could generate a peak current density of $36{\mu}A/cm^{2}$ and a maximum power density of $270nW/cm^{2}$. In this study, we improve on the previous results by using carbon micro electromechanical systems (C-MEMS), formed from the pyrolysis of patterned photoresist, to fabricate carbon electrodes of an arbitrary shape and controlled porosity to increase the surface area. With these new C-MEMS electrodes, the maximum power density of the micro-DPBFC was $516nW/cm^{2}$, a performance twice as good as the results of our previous work.
A classic examples of the abnormal combustions are the knock and misfire, which raise noxious performance and life of the engine. A heavy knock can also cause severe damages to the engine itself, which gives more reason why it must be detected and corrected. With the response of the today's requirements, we have researched the new diagnostic system which uses the breakdown voltage characteristics between electrodes of spark plug. This breakdown voltage depends on the pressure, temperature and even the shape and material of electrodes. But there is no data of breakdown voltage in case of using the spark plug as a electrodes. So, in this study, we show the breakdown voltage characteristic by pressure and temperature in constant volume bomb, which will make it possible to diagnose the engine combustion phenomenon.
In this study, the analysis was carried out for Electrical Discharge Machining (EDM) characteristics of the Cu electrodes by LIGA process. The shape of electrodes has 324 pins for the cavity of BGA(Ball Grid Array) type test socket mold. BGA test sockets are used in the inspection process of the semi-conductor I.C chip manufacturing. In the work, the machining performance for EDM of the electrodes was analyzed on dimensional accuracy and wear rate. The dimensional accuracy was measured for dimension of the pins, pitch size between the pins and the roundness of corner edge using optical measuring machine.
In the micro electrochemical machining (MECM) using ultra short pulses, the machining rate is closely related to the tool electrode area. The machining rate varies according to the machining depth or the immersion depth. When using insulated tool electrodes, those depths do not matter. In addition, micro structures with high machining depth can be fabricated because the machining characteristics do not vary with the machining depth. Another advantage of insulated electrodes is prevention of taper shape. Micro structures with high machining depth or high aspect ratio were fabricated using insulated tool electrodes.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.