• 제목/요약/키워드: shaking table study

검색결과 357건 처리시간 0.027초

Seismic rehabilitation of RC frame using epoxy injection technique tested on shaking table

  • Yu, Jiangtao;Zhang, Yuanmiao;Lu, Zhoudao
    • Structural Engineering and Mechanics
    • /
    • 제52권3호
    • /
    • pp.541-558
    • /
    • 2014
  • A 1/4-scale two-bay eight-storey reinforced concrete frame was tested on shaking table. Initial shaking table tests were carried out through a set of real seismic excitations to investigate the seismic behavior of the RC frame. Subsequently, the damaged frame was repaired using epoxy injection technique, and then subjected to the tests with the same records. The purpose of this study was to investigate experimentally the dynamic characteristics, cracking pattern and lateral inter-story stiffness of RC frames using epoxy injection technique. The test results indicate that epoxy-injection technique appears to be a satisfactory method for repairing earthquake-damaged structure.

진동대실험을 통한 축소 아치구조물의 고유진동주기 분석 (Natural Vibration Period of Small-scaled Arch Structure by Shaking Table Test)

  • 김기철;강주원
    • 한국공간구조학회논문집
    • /
    • 제15권4호
    • /
    • pp.107-114
    • /
    • 2015
  • Large spatial structures can not easily predict the dynamic behavior due to the lack of construction and design practices. The spatial structures are generally analyzed through the numerical simulation and experimental test in order to investigate the seismic response of large spatial structures. In the case of analysis for seismic response of large spatial structure, the many studies by the numerical analysis was carried out, researches by the shaking table test are very rare. In this study, a shaking table test of a small-scale arch structure was conducted and the dynamic characteristics of arch structure are analyzed. And the dynamic characteristics of arch structures are investigated according to the various column cross-section and length. It is found that the natural vibration periods of the small-scaled arch structure that have large column stiffness are very similar to the natural vibration period of the non-column arch structure. And in case of arch structure with large column stiffness, primary natural frequency period by numerical analysis is very similar to the primary natural frequency period of by shaking table test. These are because the dynamic characteristics of the roof structure are affected by the column stiffness of the spatial structure.

지진시 앵커기초의 한계성능 평가를 위한 진동대 실험 (Shaking Table Test for an Evaluation of the Limit State Capacity of an Anchor Foundation in the case of a Seismic Event)

  • 김민규;최인길;권형오
    • 한국지진공학회논문집
    • /
    • 제14권5호
    • /
    • pp.23-31
    • /
    • 2010
  • 본 연구에서는 지진시 앵커기초의 파괴한계성능을 평가하기 위하여 진동대 실험을 수행하였다. 앵커기초에 발생 가능한 열화현상인 균열의 영향을 평가하기 위하여 균열이 없는 시편, 관통균열 시편 그리고 파괴예상면 내에 측면균열이 있는 시편을 제작하여 각각의 파괴한계성능을 평가하였다. 우선적으로 임팩트 해머에 의한 가진 실험을 통하여 동특성분석실험을 수행하여 실험모형의 동특성을 분석하였으며, 앵커기초의 파괴 시까지 진동대 실험을 수행하여 극한거동을 평가하였다. 최종적으로 앵커기초의 설계기준과 비교하여 거동특성을 분석하였다.

Experimental damage evaluation of prototype infill wall based on forced vibration test

  • Onat, Onur
    • Advances in concrete construction
    • /
    • 제8권2호
    • /
    • pp.77-90
    • /
    • 2019
  • This paper aims to investigate vibration frequency decrease (vibration period elongation) of reinforced concrete (RC) structure with unreinforced infill wall and reinforced infill wall exposed to progressively increased artificial earthquake load on shaking table. For this purpose, two shaking table experiments were selected as a case study. Shaking table experiments were carried on 1:1 scaled prototype one bay one storey RC structure with infill walls. The purpose of this shaking table experiment sequence is to assess local behavior and progressive collapse mechanism. Frequency decrease and eigen-vector evolution are directly related to in-plane and out-of-plane bearing capacities of infill wall enclosure with reinforced concrete frame. Firstly, frequency decrease-damage relationship was evaluated on the base of experiment results. Then, frequency decrease and stiffness degradation were evaluated with applied Peak Ground Acceleration (PGA) by considering strength deterioration. Lastly, eigenvector evolution-local damage and eigenvector evolution-frequency decrease relationship was investigated. Five modes were considered while evaluating damage and frequency decrease of the tested specimens. The relationship between frequency decrease, stiffness degradation and damage level were presented while comparing with Unreinforced Brick Infill (URB) and Reinforced Infill wall with Bed Joint Reinforcement (BJR) on the base of natural vibration frequency.

업데이트된 집중질량스틱모델과 진동대실험 지진응답 비교 (Comparison of Seismic Responses of Updated Lumped-Mass Stick Model and Shaking Table Test Results)

  • 선휘창;홍상현;노화성
    • 한국지진공학회논문집
    • /
    • 제23권4호
    • /
    • pp.231-238
    • /
    • 2019
  • A conventional lumped-mass stick model is based on the tributary area method to determine the masses lumped at each node and used in earthquake engineering due to its simplicity in the modeling of structures. However the natural frequencies of the conventional model are normally not identical to those of the actual structure. To solve this problem, recently an updated lumped-mass stick model is developed to provide the natural frequencies identical to actual structure. The present study is to investigate the seismic response accuracy of the updated lumped-mass stick model, comparing with the response results of the shaking table test. For the test, a small size four-story steel frame structure is prepared and tested on shaking table applying five earthquake ground motions. From the comparison with shaking table test results, the updated model shows an average error of 3.65% in the peak displacement response and 9.68% in the peak acceleration response. On the other hand, the conventional model shows an average error of 5.15% and 27.41% for each response.

철근콘크리트 축소모형의 유사동적실험과 진동대 실험을 위한 상사법칙 연구 (A Study on Similitude Law for Pseudodynamic Tests and Shaking Table Tests on Small-scale R/C Models)

  • 양희관;서주원;조남소;장승필
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.545-552
    • /
    • 2006
  • Small-scale models have been frequently used for seismic performance tests because of limited testing facilities and economic reasons. However, there are not also enough studies on similitude law for analogizing prototype structures accurately with small-scale models, although conventional similitude law based on geometry similitude is not well consistent in their inelastic seismic behaviors. When fabricating prototype and small-scale model of reinforced concrete structures by using the same material, added mass is demanded from a volumetric change and scale factor could be limited due to aggregate size. Therefore, it is desirable to use different materials for small-scale model. In our recent study, a modified similitude law was derived depending on geometric scale factor, equivalent modulus ratio and ultimate strain ratio. And quasi-static and pseudo-dynamic tests on the specimens are carried out using constant and variable modulus ratios, and correlation between prototype and small-scale model is investigated based on their test results. In this study, tests on scaled model of different concrete compressive strength aye carried out. In shaking table tests, added mass can not be varied. Thus, constant added mass on expected maximum displacement was applied and the validity was verified in shaking table tests. And shaking table tests on non-artificial mass model is carried out to settle a limitation of acceleration and the validity was verified in shanking table tests.

  • PDF

소형선형 평면뼈대모형의 진동대실험을 통한 하이브리드실험 기법의 검증 (Verification of Hybrid Structural Test Technique by Shaking Table Test of a Linear 2-Dimensional Frame Model)

  • 조성민;최인규;정대성;김철영
    • 한국지진공학회논문집
    • /
    • 제14권6호
    • /
    • pp.33-43
    • /
    • 2010
  • 본 논문은 지진에 의한 구조물의 거동을 평가하기 위한 실험방법 중 최근 국내에 도입되어 연구되고 있는 하이브리드실험에 대한 시스템을 구축하고, 그에 따른 모델개발과 하이브리드실험을 실시하여 하이브리드실험기법의 타당성과 정확도를 평가하기 위함이다. 이를 위해 NEESgrid의 미니모스트 시스템을 벤치마킹하여 여건에 맞게 수정, 보완하였으며 2차원 평면뼈대모형을 개발하여 실험에 적용하였다. 그리고 하이브리드실험 결과의 평가를 위해 국내에서는 거의 시도되지 않았던 진동대실험과 비교를 함으로써 결과의 신뢰도를 높였다. 진동대실험에는 하이브리드실험과 동일한 크기의 실물모형을 제작, 실험하여 크기효과의 영향을 최소화하였다. 두 실험의 결과는 거의 비슷한 것으로 나타나 하이브리드실험이 진동대실험을 대체할 수 있을 것으로 판단된다.

적층 구조물의 동적 거동에 관한 실험적 연구 (Experimental Study on the Dynamics of Piled Multi- Block Systems)

  • 김재관;채윤병;조문형
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.275-283
    • /
    • 2002
  • In this study, the shaking table tests of block systems on the rigid base have been performed to identify the seismic response and the dynamic behavior of the piled multi-block systems. To understand the characteristics of seismic response of piled multi-block systems, it is necessary to understand the dynamic behavior of single block system. Therefore, the skating table test of the single block system has been performed first. Moreover, by performing the shaking table tests of multi-block systems, the characteristics of dynamic behavior of piled multi-block systems have been analyzed. Also in this study, the distinct element method(DEM) has been used to analyze the nonlinear behavior of the piled multi-block systems. The results of the shaking table tests show that the response of the multi-block systems is very complicated. But by using DEM, the behavior of piled multi-block systems has been predicted and described well.

  • PDF

Shaking table test of wooden building models for structural identification

  • Altunisik, Ahmet C.
    • Earthquakes and Structures
    • /
    • 제12권1호
    • /
    • pp.67-77
    • /
    • 2017
  • In this paper, it is aimed to present a comparative study about the structural behavior of tall buildings consisting of different type of materials such as concrete, steel or timber using finite element analyses and experimental measurements on shaking table. For this purpose, two 1/60 scaled 28 and 30-stories wooden building models with $40{\times}40cm$ and $35{\times}35cm$ ground/floor area and 1.45 m-1.55 m total height are built in laboratory condition. Considering the frequency range, mode shapes, maximum displacements and relative story drifts for structural models as well as acceleration, displacement and weight limits for shaking table, to obtain the typical building response as soon as possible, balsa is selected as a material property, and additional masses are bonded to some floors. Finite element models of the building models are constituted in SAP2000 program. According to the main purposes of earthquake resistant design, three different earthquake records are used to simulate the weak, medium and strong ground motions. The displacement and acceleration time-histories are obtained for all earthquake records at the top of building models. To validate the numerical results, shaking table tests are performed. The selected earthquake records are applied to first mode (lateral) direction, and the responses are recorded by sensitive accelerometers. Comparisons between the numerical and experimental results show that shaking table tests are enough to identify the structural response of wooden buildings. Considering 20%, 10% and 5% damping rations, differences are obtained within the range 4.03-26.16%, 3.91-65.51% and 6.31-66.49% for acceleration, velocity and displacements in Model-1, respectively. Also, these differences are obtained as 0.49-31.15%, 6.03-6.66% and 16.97-66.41% for Model-2, respectively. It is thought that these differences are caused by anisotropic structural characteristic of the material due to changes in directions parallel and perpendicular to fibers, and should be minimized using the model updating procedure.

기초격리된 구조물의 내진성능평가를 위한 실험기법 (Experimental Techniques for Evaluating Seismic Performance of Base-Isolated Structure)

  • 윤정방;정우정;김남식;김두훈
    • 한국지진공학회논문집
    • /
    • 제1권4호
    • /
    • pp.45-58
    • /
    • 1997
  • 본 연구에서는 다양한 입력지진에 대해서 기초격리된 구조물의 내진성능 평가를 위해서 진동대실험과 유사동적실험을 수행하였다. 본 논문의 목적은 다음과 같다. 하나는 진동대실험을 통하여 강한 지진의 발생시 저층의 구조물에 대한 기초격리시스템의 내진성능을 평가하는 것이고 다음으로는 진동대실험결과와 비교하여 기초격리시스템에 대한 유사동적실험기법의 적용성 및 신뢰성을 증명하는 것이다. 진동대실험은 적층고무받침을 이용하여 기초격리된 1/4 축소모형의 3층 철골구조물의 대상으로 하였다. 유사동적실험에서는 부분구조기법을 사용하여 단지 기초격리시스템만을 대상으로 실험되며 전체구조물의 지진응답은 컴퓨터 내에서 직접적분을 이용하여 계산된다. 진동대실험결과와 비교할 때 부분구조기법을 사용한 유사동적실험은 기초격리된 구조물의 동적응답 평가에 매우 효과적임을 알 수 있었다. 또한 대부분의 하중하에서 기초격리장치가 사용된 구조물의 경우에는 지진응답이 현저히 감소하는 것을 알 수 있었으나, 장주기파의 성분이 강한 지반운동에 대해서는 감소의 폭이 크지 않았다. 그러나 여러 지반조건에 대하여 UBC 시방서에서 규정한 설계하중에 대하여는 진동감소효과가 우수함을 보인다.

  • PDF