• Title/Summary/Keyword: shaking method

Search Result 390, Processing Time 0.03 seconds

Comparison of Results According to Reaction Conditions of Thyroglobulin Test (Thyroglobulin 검사의 반응조건에 따른 결과 비교 분석)

  • Joung, Seung-Hee;Lee, Young-Ji;Moon, Hyung-Ho;Yoo, So-yoen;Kim, Nyun-Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.39-43
    • /
    • 2017
  • Purpose Thyroglobulin (Tg) is a biologic marker of differentiated thyroid carcinoma (DTC), produced by normal thyroid tissue or thyroid cancer tissue. Therefore, the Tg values of DTC patients is the most specific indicator for judging whether recurrence occur or whether the remaining thyroid cancer is present. Thyroid cancer is currently the most common cancer in Korea, of which 90% is differentiated thyroid cancer. The number of patients with thyroid disease of this application also increased, and an accurate and prompt results are required. However, the incubation time of the Tg commonly takes about 24 hours in our hospital, and the result reporting time is delayed, and We could not satisfied with the requirements of clinical departments and patients. In order to fulfill these requirements, experiments were conducted by shortening the incubation time between company B's Kit currently in use and company C's Kit used in other hospitals. Through these experiments, we could perform the correlation with the original method and shortening method, and could find the optimum reaction time to satisfy the needs of the departments and the patients, and we will improve the competitiveness with the EIA examination. Materials and Methods In September 2016, we tested 65 patients company B's kit and company C's kit by three incubation ways. First method $37^{\circ}C$ shaking 2hr/2hr, Second method RT shaking 3hr/2hr, Third method 1hr/1hr shaking at $37^{\circ}C$. Fourth method RT shaking 3hr method which is the original method of Company C's Kit. Fifth method, the incubation time was shortened under room temperature shaking 2hr, Sixth method $37^{\circ}C$ shaking 2hr. And we performed and compared the correlation and coefficient of each methods. Results As a result of performing shortening method on company B currently in use, when comparing the Original method of company B kit, First method $37^{\circ}C$ shaking 2hr/2hr was less than Tg 1.0 ng/mL and the ratio of $R^2=0.5906$, above 1.0 ng/mL In the value, $R^2=0.9597$. Second method RT shaking 3hr/2hr was $R^2=0.7262$ less than value of 1.0 ng/mL, $R^2=0.9566$ above than value of 1.0 ng/mL. Third method $37^{\circ}C$ shaking 1hr/1hr was $R^2=0.7728$ less than value of 1.0 ng/mL, $R^2=0.8904$ above than value of 1.0 ng/mL. Forth, Company C's The original method, RT shaking 3hr was $R^2=0.7542$ less than value of 1.0 ng/mL, and $R^2=0.9711$ above than value of 1.0 ng/mL. Fifth method RT shaking 2hr was $R^2=0.5477$ less than value of 1.0 ng/mL, $R^2=0.9231$ above than value of 1.0 ng/mL. Sixth method $37^{\circ}C$ shaking 2hr showed $R^2=0.2848$ less than value of 1.0 ng/mL, $R^2=0.9028$ above than value of 1.0 ng/mL. Conclusion Samples with both values of 1.0 ng/mL or higher in both of the six methods showed relatively high correlation, but the correlation was relatively low less than value of 1.0 ng/mL. Especially, the $37^{\circ}C$ shaking 2hr method of company C showed a sharp fluctuation from the low concentration value of 1.0 ng/mL or less. Therefore, we are planning to continuously test the time, equipment, incubation temperature and so on for the room temperature shaking 2hr method and $37^{\circ}C$ shaking 1hr/1hr of company C which showed a relatively high correlation. After that, we can search for an appropriate shortening method through additional experiments such as recovery test, dilution test, sensitivity test, and provide more accurate and prompt results to the department of medical treatment, It is competitive with EIA test.

  • PDF

Studies on the Extraction Efficiency of Polyacetylene from Korean Ginseng (추출방법에 따른 인삼의 Polyacetylene 성분 회수율 비교 연구)

  • 박찬엘;박창호
    • KSBB Journal
    • /
    • v.16 no.3
    • /
    • pp.264-268
    • /
    • 2001
  • The extraction efficiencies of panaxynol and panaxydol were optimal at 80$^{\circ}C$ with soxhlet method. The extraction efficiencies increased up to 45$^{\circ}C$ with shaking method. Amounts of panaxynol and panaxydol were determined by gas chromatography. Extracted quantities of panaxynol and panaxydol using the shaking method increased over a period of 14 hours. The efficiencies of panaxynol and panaxydol extraction by soxhlet and shaking methods were higher for smaller particle sizes. Upon water swelling treatment, extraction efficiencies of panaxynol and panaxydol decreased gradually with time for both methods.

  • PDF

Bycatch Reduction by Experimental Shaking Codend Attached with Canvas in a Bottom Trawl

  • Kim, Yonghae
    • Fisheries and Aquatic Sciences
    • /
    • v.18 no.3
    • /
    • pp.325-332
    • /
    • 2015
  • An active stimulating method for juvenile fishes to drive escaping from mesh of the codend was examined by shaking canvas in the bottom trawl followed by shrimp beam trawl. Field fishing trials by a bottom trawl were carried out between the Geomoondo and Jejudo in west of South sea, Korea by conver-net methods to examine the effect on the reduction of juvenile fish as a discard catch by generating a shaking movement of the codend using two pieces of asymmetrical semi-circular canvas. The mean period of the shaking motion with the round canvas was 10-15 s, and the range of amplitude as a vertical depth change was up to 0.4-0.6 m when towing speed 3.4-4.3 k't as estimated by peak event analysis. The escape rate of juvenile fish in conver-net by total juvenile bycatch (codend and cover-net) in 14 trials increased from 20% in a steady codend to 34% using a shaking codend in the bottom trawl, while the marketing catch or total bycatch was similar between steady and shaking cod ends. There was no difference in the body size of the fish and species composition between the steady and shaking cod ends. Above results demonstrate a new method for bycatch reduction actually up to 18% using an active stimulating device, although further experiments are needed to increase an effective shaking motion of the codend in amplitude and period for more bycatch reduction.

Shaking table test on soil-structure interaction system (1) : Superstructure with foundation on half-space soil (건물-지반 시스템에 관한 진동대실험 (1) : 반무한지반위의 구조물)

  • Lee Sung-Kyung;Masato Motosaka;Min Kyung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.538-547
    • /
    • 2005
  • This paper presents the shaking table testing method, only using building specimen as an experimental part taking into account the dynamic soil-structure interaction based on the substructure method. The Parmelee's soil stiffness is used as an assumed soil model in here. The proposed methodologies are summarized as: (1) Acceleration feedback method is the one that the shaking table is driven by the motion, corresponding to the acceleration at foundation of the total SSI system. This is found by observing the fed-back accelerations of superstructure and using the interaction force based on the acceleration formulation. (2) Velocity feedback method is the one that the shaking table is driven by the motion, corresponding to the velocity at foundation of the total SSI system. This is found by observing the fed-back accelerations of superstructure and using the interaction force based on the velocity formulation. The applicability of the proposed methodologies to the shaking table test is investigated and experimentally verified in this paper.

  • PDF

Shaking Table Testing Method Considering the Dynamic Soil-Structure Interaction (건물과 지반의 동적상호작용을 고려한 진동대 실험법에 관한 연구)

  • Lee, Sung-Kyung;Lee, Sang-Hyun;Chung, Lang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.184-191
    • /
    • 2010
  • This paper proposes the shaking table testing method for replicating the dynamic behavior of soil-structure interaction (SSI) system, without any physical soil model and only using superstructure model. Applying original SSI system to the substructure method produces two substructures; superstructure and soil model corresponding to experimental and numerical substructures, respectively. Interaction force acting on interface between the two substructures is observed from measuring the accelerations of superstructure, and the interface acceleration or velocity, which is the needed motion for replicating the dynamic behavior of original SSI system, is calculated from the numerical substructure reflecting the dynamic soil stiffness of soil model. Superstructure is excited by the shaking table with the motion of interface acceleration or velocity. Analyzing experimental results in time and frequency domains show the applicability the proposed methodologies to the shaking table test considering dynamic soil-structure interaction.

  • PDF

Numerical Simulation on the Shaking Table Test considering Soil Structure Interaction (구조물과 지반의 동적 상호작용을 고려한 진동대 시험에 관한 수치 시뮬레이션)

  • Lee, Sung-Kyung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.5 s.45
    • /
    • pp.21-28
    • /
    • 2005
  • This paper proposes a shaking table test considering the dynamic soil strcuture interaction (SSI) by using the accelerations measured from superstructure and shaking table. The proposed method based on the substructure method is that only superstructure is used as an experimental model and dynamic soil stiffness is reflected on the controller of shaking table for soil model. At the moment, an experimental superstructure is excited by a shaking table with the motion required to emulate the dynamic behavior of total SSI system. First, the validity of the proposed method is verified by the verification model of numerical simulation, which is derived from the equation of motion of SSI system under consideration. Also, the applicability of the proposed method to shaking table test is numerically verified from the simulation model incorporating the transfer function of shaking table.

Effects on bycatch reduction in a shaking cod end generated by canvas in a shrimp beam trawl

  • Kim, Yonghae;Whang, Dae-Sung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.3
    • /
    • pp.342-350
    • /
    • 2014
  • An active stimulating device, such as a fluttering net or canvas attached to the end of a cod end generating a shaking motion, could help to encourage the escape of juvenile fish positioned passively near the net. Field fishing trials using a shrimp beam trawl were carried out to examine the effect on the reduction of juvenile fish or other discard catch by generating a shaking movement of the cod end using an unbiased cap-like round canvas. The mean period of the shaking motion with the round canvas was ~14 s, and the mean amplitude was 0.4 m as measured by peak event analysis and the global wavelet method. The bycatch of juvenile fish in 14 trials decreased by ~30% and by ~25% using a steady cod end for the total bycatch using a shaking cod end in the shrimp beam trawl, while the marketing catch was similar between steady and shaking cod ends. There was no difference in the body size of the shrimp or fish and species composition between the steady and shaking cod ends. Above results demonstrate a new method for bycatch reduction using an active stimulating device, although more detailed studies are needed.

Applicability of the HPLC Method for the Estimation of Octanol/water Partition Coefficient to Pesticides of Domestic Use (국내 사용 농약을 대상으로 한 HPLC 방법에 의한 옥탄올/물 분배계수 추정법의 적용성 검토)

  • Kim, Kyun;Kwon, Jin-Wook;Kim, Yong-Hwa
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.4
    • /
    • pp.189-196
    • /
    • 2001
  • Octanol/water partition coefficients of 52 chemicals were calculated using RP-HPLC estimation method and predicted by computer program, PCHEM. The result showed relationship between literature values and RP-HPLC observed values (relative coefficient r$^2$=0.916), but the relationship of PCHEM values with literature values was lower than RP-HPLC value (relative coefficient r$^2$=0.795). The average difference in partition coefficient between the RP-HPLC method and flask-shaking method was log Kow=0.54, while the average difference between the values predicted form the computer program and flask- shaking method was log Kow = 0.36 Compared to octanol/water partition coefficients by 3 methods (Flask-shaking, RP-HPLC, computer prediction), the octanol/water partition coefficient values based on the flask-shaking method were very similar to the literature values, while the octanol/water partition coefficient values by RP-HPLC method without to consider the dead time, and computer prediction values did not significantly differ with the literature values.

  • PDF

Performance Evaluation of Controlling Seismic Responses of a Building Structure with a Tuned Liquid Column Damper using the Real-Time Hybrid Testing Method (실시간 하이브리드 실험법을 이용한 동조액체기둥감쇠기가 설치된 구조물의 지진응답 제어성능 평가)

  • Chung, Hee-San;Lee, Sung-Kyung;Park, Eun-Churn;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.669-673
    • /
    • 2007
  • In this study, real-time hybrid test using a shaking table for the control performance evaluation of a U-shaped TLCD controlling the response of earthquake-excited building structure is experimentally implemented. In the test, the building structure is used as a numerical part, on which a U-shaped TLCD adopted as an experimental part was installed to reduceits response. At first, the force that is acting between a TLCD and building structure is measured from the load cell attached on shaking table and is fed-back to the computer to control the motion of shaking table. Then, the shaking table is so driven that the error between the interface acceleration computed from the numerical building structure with the excitations of earthquake and the fed-back interface force and that measured from the shaking table. The control efficiency of the TLCD used in this paper is experimentally confirmed by implementing this process of shaking table experiment on real-time.

  • PDF

Automatic Jitter Evaluation Method from Video using Optical Flow (Optical Flow를 사용한 동영상의 흔들림 자동 평가 방법)

  • Baek, Sang Hyune;Hwang, WonJun
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.8
    • /
    • pp.1236-1247
    • /
    • 2017
  • In this paper, we propose a method for evaluating the uncomfortable shaking in the video. When you shoot a video using a handheld device, such as a smartphone, most of the video contains unwanted shake. Most of these fluctuations are caused by hand tremors that occurred during shooting, and many methods for correcting them automatically have been proposed. It is necessary to evaluate the shake correction performance in order to compare the proposed shake correction methods. However, since there is no standardized performance evaluation method, a correction performance evaluation method is proposed for each shake correction method. Therefore, it is difficult to make objective comparison of shake correction method. In this paper, we propose a method for objectively evaluating video shake. Automatically analyze the video to find out how much tremors are included in the video and how much the tremors are concentrated at a specific time. In order to measure the shaking index, we proposed jitter modeling. We applied the algorithm implemented by Optical Flow to the real video to automatically measure shaking frequency. Finally, we analyzed how the shaking indices appeared after applying three different image stabilization methods to nine sample videos.