• Title/Summary/Keyword: shade device

Search Result 21, Processing Time 0.023 seconds

Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study

  • Kim, Hee-Kyung
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.252-258
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS. The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (${\alpha}=.05$). RESULTS. A high level of measurement repeatability (ICC>0.90) among $L^*$, $a^*$, and $b^*$ color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were $2.28{\pm}1.61$ ${\Delta}E_{00}$ for in-vivo readings. Regarding the clinical matching accuracy of both devices, ${\Delta}E_{00}$ values between teeth and matching shade tabs were $3.05{\pm}1.19$ and $2.86{\pm}1.02$, respectively. CONCLUSION. Although two EasyShade V devices with different serial numbers show high repeatability of CIE $L^*$, $a^*$, and $b^*$ measurements, they could provide different color values and shade for the same tooth.

Evaluation of Lighting Environment about the Characteristics of Shading Device (차양장치 특성에 따른 조명환경 평가)

  • Hong, Seong-Kwan;Lim, Ji-Sun;Jung, Yeon-Hong;Kim, Yu-Sin;Choi, An-Seop;Kwun, Joon-Bum
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.153-156
    • /
    • 2008
  • According to the conversion of building into skyscraper, most buildings have curtain wall structures, so the shading device of building is required. The types of shading systems are a roller shade, venetian bind, and vatical blind and so on. A miler shade is mostly used among the shading systems. An experimental evaluation was verified whether there was an effect of shading materials(Perforated panel, Fabric) in each condition by an experiment with artificial lighting and daylight.

  • PDF

A Study of Simplified Calculation Methods for Outside Vertical Illuminance using VBA (VBA(Visual Basic for Applications)를 활용한 실외 수직면 조도 간이계산법에 관한 연구)

  • Yun, Su-In;Kim, Kang-Soo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.12
    • /
    • pp.65-72
    • /
    • 2018
  • The purpose of this study is to predict vertical illuminance accurately at the design stage of a building without the help of simulation tools. Comparing two well-known vertical illuminance prediction algorithms with measured values, it is verified that the Igawa model is more consistent with the measured values than the Perez model. Using the DIVA program, we simulated the vertical illuminance at 30-degree intervals from south to north, compared with the vertical illuminance calculated with the Igawa model. The result of calculation values were verified from 120 degrees east to 120 degrees west. The vertical illuminance values with each of three shade devices were calculated using the Igawa model, and compared with the vertical illuminance simulated by DIVA program. As a result, all the errors when installing horizontal / vertical / grid shade divices were included in the error standard specified by ASHRAE.

Color discrepancy of single-shade composites at different distances from the interface measured using cell phone images

  • Marcia Luciana Carregosa Santana;Gabriella de Jesus Santos Livi;Andre Luis Faria-e-Silva
    • Restorative Dentistry and Endodontics
    • /
    • v.49 no.1
    • /
    • pp.7.1-7.11
    • /
    • 2024
  • Objectives: This study aimed to evaluate the impact of substrate color and interface distance on the color adjustment of 2 single-shade composites, Vittra APS Unique and Charisma Diamond One. Materials and Methods: Dual disc-shaped specimens were created using Vittra APS Unique or Charisma Diamond One as the center composite, surrounded by shaded composites (A1 or A3). Color measurements were taken with a spectrophotometer against a gray background, recording the color coordinates in the CIELAB color space. Illumination with a light-correcting device and image acquisition using a polarizing filter-equipped cell phone were performed on specimens over the same background. Image processing software was used to measure the color coordinates in the center and periphery of the inner composite and in the outer composite. The color data were then converted to CIELAB coordinates and adjusted using data from the spectrophotometer. Color differences (ΔE00) between the center/periphery of single-shade and outer composites were calculated, along with color changes in single-shade composites caused by different outer composites. Color differences for the inner composites surrounded by A1 and A3 were also calculated. Data were analyzed using repeated-measures analysis of variance (α = 0.05). Results: The results showed that color discrepancies were lowest near the interface and when the outer composite was whiter (A1). Additionally, Charisma Diamond One exhibited better color adjustment ability than Vittra APS Unique. Conclusions: Color discrepancies between the investigated single-shade composites diminished towards the interface with the surrounding composite, particularly when the latter exhibited a lighter shade.

A Study on Structural Analysis of Color Discerning Device for the Performance Enhance (Color Discerning Device의 구조해석을 통한 성능향상에 대한 연구)

  • Kim, Sung-Hyun;Lee, Kyu-Ho;Chung, Jin-Tai
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.571-576
    • /
    • 2006
  • A Color Discerning Device(CDD) is the equipment to use in Rice Processing Complex(RPC). By use a high-speed charge-coupled device camera, CDD can sorting discolored grain according to light and shade. The existing CDD's driving performance is not so good as overseas machine. Besides, transportation process causes a defect in the mechanism from impact or harmonic excitation or etc. This study is represented the problem of CDD through modal analysis and static analysis by using ANSYS workbench. To analysis the problem of driving condition, devide each part of CDD for performed modal analysis. The problem of driving condition and transportation process solved by carry out modal analysis and static analysis.

  • PDF

A Study on Control Algorithms of Efficiency Improvement Device for PV System Operation using Li-ion Battery (리튬이온전지를 이용한 태양광전원의 운용효율향상장치의 제어 알고리즘에 관한 연구)

  • Park, Ji-Hyun;Kim, Byung-Mok;Lee, Hu-Dong;Nam, Yang-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.590-597
    • /
    • 2018
  • Recently, the installation of PV systems has been increasing due to the worldwide interest in eco-friendly and renewable solar energy. On the other hand, the output power of PV systems is influenced strongly by the surrounding weather conditions. In addition, the entire operation efficiency of PV systems may be decreased considerably even if only some of the PV modules are in the shade. In other words, the existing control method at which strings with modules in series are connected to an inverter may be not operated in the case that the string voltage in partial shade is lower than the operating range of the grid connected inverter. To overcome these problems, this paper proposes an operation efficiency improvement device of a PV system using a Li-ion battery, which can compensate for the voltage of each string in the PV system when it is partially shaded. In addition, this paper presents the modeling of the operation efficiency improvement device, including PV strings, Li-ion battery and a 3-Phase grid inverter based on the PSIM S/W. From the simulation results, it was confirmed that the proposed control method can improve the operating efficiency of PV systems by compensating for the string voltage with partial shade.

A Study on the Lighting Energy Performance Analysis of a Shading Device based on Visual Comfort (시각적 쾌적성을 고려한 차양장치의 조명에너지 성능 분석 방법에 관한 연구)

  • Oh, Min-Seok;Lee, Ju-Yoon;Kim, Gi-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.6
    • /
    • pp.1-14
    • /
    • 2018
  • The shading device on the window of the building can be an passive solution to reduce the cooling load and lighting energy, as well as improving the indoor comfort. It is also an architectural element that must be considered for building energy-efficient buildings such as eco-buildings and zero-energy buildings. However, due to various building environments and various shading devices, the installation of excessive shade may lead to the risk of losing the effectiveness of windows. In this study, we propose a method for optimal automatic control of shading device and evaluate its effectiveness by energy analysis of several shading devices.

Measure of shade differences according to the concentration of dental zirconia coloring liquid (치과용 지르코니아 코어에서 착색농도에 따른 색조측정)

  • Bae, Eun-Jeong;Lee, Hee-Jung;Kim, Hae-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.35 no.3
    • /
    • pp.193-200
    • /
    • 2013
  • Purpose: In this study, in order to provide objective standard of the mixed concentration of the zirconia coloring-liquids, compare the shade differences after colored zirconia blocks from different concentrations. Methods: After immersion for 2 minutes zirconia specimen ($1.5{\times}1.5{\times}0.6{\pm}0.01mm$) in coloring-liquids that produced different concentrations, were sintered in furnace dedicated. Then, it was measured in spectrophotometer and Shadepilot. It has been determined mean and standard deviation of the color difference for each group, and verified by one-way ANOVA using the (version12.0) SPSS WIN Program the difference in shade according to the concentration at the significance level of 95% confidence, it conducted a Tukey's multiple range test to post-test. Results: The mean of $L^*$ was decreased toward LN35 group, however the mean of $a^*$ and $b^*$ was increased(p<.05). There is a statistically significant difference in the results of $L^*$ post hoc test of each group was LN15-LN30/LN35, LN20-LN30/LN35, LN25-LN30/LN35, and LN30-LN35 group. The $a^*$ group, it was found that there is a statistically significant difference in all groups for each(p<.05). The $b^*$ group, it was found that there is a statistically significant difference in all groups except the LN25-LN30(p<.05). Conclusion: In order to make effective use of the coloring-liquids of zirconia, the device objective, accurate concentration measurement is required, from the present study, we presented evidence basic to this.

A GEOMETRIC STANDARDIZATION OF PERIAPICAL INTRAORAL RADIOGRAPHY (구내 표준 방사선 사진촬영의 위치 표준화)

  • Choi Bong-In;Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.415-423
    • /
    • 1991
  • This study was performed to evaluate the geometric standardization of periapical intraoral radiography. Image distortion was measured by analysing serial radiography obtained from dry skull using 5 types of bite registration device. After 16 weeks, the angular distortion of Pattern resin was 0.26±0.14 degree(Horizontal angle 0.17±0.14, Vertical angle 0.16±0.11) which was the lowest among the 5 registration device, and that of putty type Exaflex was 0.49±0.35 degree(Horizontal angle 0.42±0.35, Vertical angle 0.17±0.13) which was the highest. The mean amount of distortion variance of Tooth shade acrylic at each experimental period was 0.06±0.08 which was the lowest among the 5 registration device, and that of XCP alone was 0.ll±0.13 which was the highest.

  • PDF

Finite Element Analysis of a Color Discerning Device for Performance Improvement (성능 개선을 위한 곡물 선별기의 유한요소해석)

  • Kim, Sung-Hyun;Lee, Kyu-Ho;Chung, Jin-Tai
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.702-707
    • /
    • 2007
  • A Color Discerning Device(CDD) is the equipment to use in a Rice Processing Complex(RPC). A CDD can sorting discolored grain according to light and shade. The existing a CDD's driving performance is not so good as overseas machine. Besides, transportation process causes a defect in the mechanism from impact or harmonic excitation or etc. This study is represented the problem of CDD through experiment and simulation on a CDD. To analysis the problem of driving condition, devide each part of CDD for performed modal analysis. The problem of driving of driving condition and transportation process solved by carry out modal analysis and static analysis.

  • PDF