• 제목/요약/키워드: sewage treatment system

검색결과 372건 처리시간 0.028초

하수처리시설의 슬러지 수거 일정계획 수립 및 수거차량 경로결정 (The Sludge Collection Scheduling and Vehicle Routing Strategies)

  • 조종무;노의수;김민제;허은정;최경현
    • 산업경영시스템학회지
    • /
    • 제30권1호
    • /
    • pp.105-114
    • /
    • 2007
  • In this paper, we propose sludge collection strategies which allocate each sewage store of village to sewage treatment plants and decide the schedule of sludge collection in order to collect sludge efficiently. The strategies aim to decrease transportation cost with deciding proposed vehicle routing and scheduling the sludge collection. When we decide route of vehicles, we consider the collection time in sewage store of village, distance between sewage store of villages and vehicle information as average velocity of vehicle, operation time of vehicle driver. We also develop the SCMS (Sludge Collection Management System) based on windows system with real data which is used in certain circumstance. And we experiment to figure out vehicle route and transportation cost throughout changing input data.

강우시 저농도 고수리부하가 회분식 반응조 제거효율에 미치는 영향 (Effects of Inflow Fluctuation on the Removal Efficiency in Low Strength Sewage Treatment using Sequencing Batch Reactor Process during Rainfall)

  • 어성욱;김건하;손봉호
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.91-96
    • /
    • 2006
  • Many small scale Sewage Treatment Plants (STPs) are currently being constructed at many rural areas. The STPs in rural area suffer from low concentration and large inflow quantity fluctuation during wet weather mainly due to illicit combined sewer system. Sequencing Batch Reactor (SBR) is a process effectively coping with these obstacles. The main objective of this study was to evaluate SBR with high hydraulic loading and low inflow concentration. The operating conditions tested were: organic loading rate = $0.17-0.42KgBOD/m^3/d$, hydraulic loadings = $12.1-61.5m^3/m^2/d$, average MLSS concentration = 2500 mg/L, F/M ratio = 0.026-0.17 KgBOD/Kg MLSS, HRT = 9-12 hr HRT, and SRT = 5.6-33.6 days. Organic loading rate on SBR did not impact significantly on BOD and SS removal efficiencies. To increase treatment efficiencies, low hydraulic loading rate with low concentration was required. The results suggested that low influent concentration with high inflow rates during wet weather requires extended time for settling.

일체형 완속교반침전조와 섬유여과기를 이용한 반류수 인 제어시스템의 경제성 연구 (Economic Assesment of Phosphorus Control System for Reject Water using a Integral Type Slow Mixing/Sedimentation Tank and Fiber Filter)

  • 김미란;김정숙;장정국
    • Korean Chemical Engineering Research
    • /
    • 제55권6호
    • /
    • pp.822-829
    • /
    • 2017
  • 하수처리장에서의 총 인 저감을 위한 방안으로 완속교반/침전 섬유여과시스템을 적용하여 하수 방류수와 반류수를 제어하는 방법에 대해 비교 검토하였다. 물질수지를 통해 인의 최종 농도를 강화된 기준치인 0.2 mg/L로 낮추기 위해서는 약 92.4 kg T-P/day를 제거해야 되는 것으로 분석되었으며, 이를 위한 총 인 제거효율은 하수 방류수는 96%, 반류수(탈수여액)은 69.2% 이상이 되어야 한다. 총 인 제거 목표치를 달성하기 위한 시스템 운영비용을 검토하였으며, 하수방류수를 처리하는 것보다 유량은 적으나 고농도의 인을 함유한 반류수를 처리하는 것이 약품비용은 약 1/2.4, 전력비용은 약 1/120 정도로 절감되는 것으로 나타났다. 한편 반류수 처리를 위해 개발시스템인 완속교반/침전 섬유여과시스템과 일반적인 응집침전시스템을 적용하는 경우에 대한 경제성을 검토하였으며, 완속교반/침전 섬유여과시스템이 일반적인 응집침전시스템에 비해 설치면적이 약 1/7로 작고 약품소요량 및 전력비를 포함한 연간운전비용은 약 1/1.7 소요되어 개발시스템이 보다 경제성이 있는 것으로 평가되었다.

하수도 시스템의 효율적인 운영 및 유지관리를 위한 시스템다이내믹스 모형의 개발 (Development of a System Dynamics Model for the Efficient Operation and Maintenance of Sewerage Systems)

  • 박수완;이태근;김봉재;김태영
    • 한국수자원학회논문집
    • /
    • 제45권1호
    • /
    • pp.101-111
    • /
    • 2012
  • 본 논문에서는 시스템 다이내믹스(System Dynamics, SD) 방법론에 입각하여 하수도 시스템의 운영지표들과 이에 영향을 미치는 외부변수들로 구성된 피드백 루프 메커니즘(Feedback Loop Mechanism)을 관로유지관리와 연관하여 규명하고, 외부변수의 변화에 따른 운영지표의 변화를 예측함으로써 하수도 시스템의 효율적인 운영 및 유지관리 방안을 모색할 수 있는 SD 컴퓨터 모의 모형(Computer Simulation Model)을 개발하였다. 개발된 모형에 부산광역시 하수도 시스템의 과거 운영 자료를 적용함으로써 모형을 검증하였고, 미래의 운영 상황을 예측하였다. 그 결과, 하수도보급률은 이미 목표치에 거의 도달하여 큰 변동이 없을 것으로 예측되었으며, 하수처리효율과 하수처리량, 요금현실화율은 점차 증가할 것으로 예측되었다. 또한 정책 지렛대의 발견을 위해 시스템에 큰 영향을 미치는 주요 운영지표를 선정하여 외부변수의 변화에 대한 민감도 분석을 수행하였는데, 그 결과 관로 유지관리와 연관된 외부변수는 하수처리효율의 변화뿐만 아니라 시설이용률, 하수처리량 등의 변화에도 큰 영향을 미치는 것으로 분석되었다.

울산지역에서 자생하는 갈대, 부들, 갈풀을 이용한 Reed-Bed의 생활하수 정화능력 연구 (Effect of Reed-Bed using Ulsan-habitated P.australis, T.orientalis, and P.aundinacea L. on Removing Pollutants from Sewage)

  • 심우섭;한인섭
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.117-122
    • /
    • 1998
  • We examined whether several reeds, which are found around Ulsan area, could be used for downflow reed-bed to remove pollutants of sewage. Three kinds of reed, such as Phagnltes auspuis, ha orientdls, and Phduis aundinacea L., were collected from their habitats near the Taehwa River in Ulsan City. In the minimized model system of dowMlow reed-bed, P.auskdls appeared to reduce BOD more than others did but s119h11y Increase total amount of nitrogen(N). When p. auspdis were placed in the sterilized water. total nitrogen was found to be signincantly increased dependent on the number of experimental plant In the sterilized state, but it was rather decreased in the non-sterilized state. With these results, nlicroorganisms attached to p.auspuis roots can be thought to work for removal of pollutants. Therefore, these microorganisms and their habitat, p. auskdis reed bed, together can be used for sewage treatment It was suggested that oxygen Is produced by photosynthesis reaction of P ecustrdis. The increased oxygen may help microorganisms in their habitats to work on the removal of pollutants.

  • PDF

불완전 분류식 하수처리구역의 강우에 의한 하수도시설의 침입수/유입수 영향 분석 (Effect of infiltration/inflow by rainfall for sewerage facilities in the area with partially separate sewer system)

  • 신정섭;한상원;육준수;이춘구;강선홍
    • 상하수도학회지
    • /
    • 제33권3호
    • /
    • pp.177-190
    • /
    • 2019
  • The purpose of this study was to analyze the effects of sewerage facilities through I/I analysis by rainfall by selecting areas where storm overflow diverging chamber is remained due to the non-maintenance drainage equipment when the sewerage system was reconstructed as a separate sewer system. Research has shown that wet weather flow(WWF) increased from 106.2% to 154.8% compared to dry weather flow(DWF) in intercepting sewers, and that the WWF increased from 122.4% to 257.6% in comparison to DWF in storm overflow diverging chamber. As a result, owing to storm overflow diverging chamber of partially separate sewer system with untreated tributary of sewage treatment plant, rainfall-derived infiltration/inflow(RDII) has been analyzed 2.7 times higher than the areas without storm overflow diverging chamber. Meanwhile, infiltration quantity of this study area was relatively higher than that of other study areas. Therefore, it is necessary to reduce infiltration quantity through sewer pipe maintenance nearby river. Drainage equipment maintenance should be performed not to operate storm overflow diverging chamber in order to handle the appropriate sewage treatment plant capacity for rainfall because it is also expected that RDII due to rain will occur after maintenance. In conclusion, it is necessary to recognize aRDII(allowance of rainfall-derived infiltration/inflow) and to be reflected it on sewage treatment plant capacity because aRDII can occur even after maintenance to the complete separate sewer system.

BM 미생물제제를 이용한 크루즈선 오·폐수 고도처리 (Advanced Treatment of Shipboard Sewage by SBR Process with BM)

  • 김인수;장재수;이언승;고성철
    • 한국항해항만학회지
    • /
    • 제36권8호
    • /
    • pp.643-649
    • /
    • 2012
  • 본 연구에서는 크루즈선에서 발생하는 오 폐수의 고도처리를 위하여 SBR공정에 유효미생물을 주입하는 변법을 이용하여 실험실 규모의 실험을 수행하였다. 질소 인의 고도 처리 효율과 크루즈선이라는 특수 환경과의 접목성을 검토한 결과 SBR공정에 유효미생물을 주입하는 변법은 선박환경에 매우 적합한 것으로 평가되었다. 또한 기존의 활성슬러지에 유효미생물의 주입함으로써 슬러지 팽화 등의 문제를 해결할 수 있어 슬러지의 안정성을 확보할 수 있었으며, 미생물 관찰 결과 고도처리에 유리한 미생물종의 출현으로 질소 인의 처리 효율이 높아지는 것을 확인할 수 있었다. 이로 인해 총질소와 인의 제거 효율은 74%, 75%로 나타났으며 이러한 결과로 미루어 강화되어가는 해양오염기준을 충만족시킬 수 있을 공정으로 판단된다.

A Study on the Odor Removal Control System of Sewage Sludge

  • KIM, Su-Hye;LEE, So-Hee;YUN, Yeo-Jin;CHOI, Soo-Young;JUNG, Min-Jae;KWON, Woo-Taeg
    • 웰빙융합연구
    • /
    • 제4권2호
    • /
    • pp.19-25
    • /
    • 2021
  • Purpose: The purpose of this study is to reduce odor complaints by identifying problems with odor management at the site of the water regeneration center and researching odor management methods. Due to the high population density of Korea, sewage treatment facilities are adjacent to residential and industrial areas. According to previous studies, the main malodor-emitting facilities of sewage treatment facilities were preliminary treatment facilities (2,220 times), sedimentation basins (4,628 times), and sludge treatment facilities (9,616 times). Research design, data and methodology: Compound malodors and designated malodor-producing substances were collected from five site boundaries of the water regeneration center and analyzed according to the official methods to test malodor, and a total of two times (August and September 2020) were conducted. Results: As a result of the measurement, in the green area in front of the center office, compound malodors were detected at a maximum of 8 times and at least 3 times during the dawn time. As for the designated malodor-producing substances, 0.1ppm of ammonia was detected in the green area in front of the center office and the park golf course. This is within 15 times the maximum allowable emission level of compound malodors and within 1ppm of the maximum allowable emission level of ammonia. Conclusions: Even if the dilution rate of the compound malodors did not exceed the maximum allowable emission level, the odor could be recognized, and more research is needed in the future to establish effective reduction measures according to the subjective and individual and seasonal odor characteristics.

하수처리장 방류수의 응집 및 정밀여과 처리공정에 관한 연구 (A Study on Coagulation and MF Membrane Process for the Reuse of Sewage Effluent)

  • Paik, Ke-Jin
    • 환경위생공학
    • /
    • 제20권3호
    • /
    • pp.36-43
    • /
    • 2005
  • 하수처리장 방류수의 재이용을 위해 2004년 1월$\~$12월까지 수질상태를 조사하였다. BOD, SS, 탁도, 총인과 색도의 월별로 조사한 연평균은 각각 4.1mg/L, 2.9mg/L, 0.8NTU, 1.3mg/L, 27unit이었다. 쟈테스트는 급속혼화 5분, 완속교반 15분, 침전 1시간의 조건하에서 오염물질의 제거율을 조사하였다. 사용된 응집제는 Alum과 폴리염화알루미늄이고, 방류수 중의 색도, 탁도, 총인, 총유기탄소 등을 제거하는데 효과가 있었다. 특히 폴리염화알루미늄을 사용시 탁도와 용존성인의 제거 효과가 좋았다. 응집공정과 연속한 정밀여과 공정에 의한 유기물의 제거효과를 조사한 결과, 분자량 1,000 Dalton 이상의 범위에 있는 물질의 제거가 잘 이루어진 반면, 소독부산물의 생성에 영향을 주는 분자량 500 Dalton 이하 물질의 제거율은 낮은 것으로 조사되었다. 따라서 복합공정에서 이 범위 분자량의 물질을 제거하기 위해 흡착공정 등의 추가공정이 필요할 것으로 본다.