• 제목/요약/키워드: sewage treatment system

검색결과 371건 처리시간 0.022초

Open System 수열반응을 통한 하수슬러지 소각 비산재의 Zeolite 합성가능성 (Synthesis of Zeolite from Sewage Sludge Incinerator Fly Ash by Hydrothermal Reaction in Open System)

  • 이제승;엄석원;최한영
    • 한국환경보건학회지
    • /
    • 제33권4호
    • /
    • pp.317-324
    • /
    • 2007
  • The sewage treatment sludge disposal has become a serious environmental problem because of restricted direct land-filling and oceandumping in spite of their large amounts discharged. So the recycling of sewage treatment sludge is very useful alternative for waste management. Here, we studied the feasibility of zeolite synthesis in open system from the sewage treatment sludge incinerator fly ash by means of hydrothermal synthesis. We considered the concentration of NaOH, reaction time, reaction temperature and reaction step as synthesis variables. The phase of zeolite products was identified by X-ray diffractometer(XRD) and ammonium ion exchange test was performed for the raw fly ash and two zeolite products(Z-3 and Z-5). In leaching test of the raw fly ash, hazard metal is detected very low level compared with regulatory leaching test standard. But in total recoverable test, the total contents of the fly ash were very high in terms of the standard for waste-derived fertilizer. Through hydrothermal reaction, small amount of zeolite P was synthesied in 1 N of NaOH solution and relatively large amount of hydroxysodalite was synthesied in 3 N and 5 N of NaOH solution with similar peak intensity. Addition of an aging step in the synthesis didn't increase the amount of zeolite phase. Maximum $NE_4^+-N$ exchange capacity is 1.49 mg $NH_4^+-N/g$ in Z-3 and 1.38 mg $NH_4^+-N/g$ in Z-5. Most of the ammonium ion is exchanged in 30 minutes and disorption did not occur until 5 hours.

다단토양층을 이용한 하수처리에 관한 연구 (Study of Sewage Treatment using Multi-soil-layering System)

  • 손대희;정윤철;신정훈;정진영;안대희
    • 한국물환경학회지
    • /
    • 제20권3호
    • /
    • pp.215-222
    • /
    • 2004
  • The sewages produced from small villages, rural community, drinking water reservation area and park which doesn't have sewage piping system can be caused a serious water pollution at the restricted areas. The objective of this research was to suggest an economical and effective sewage treatment method by investigating the removal of the organics, nitrogen, and phosphorus in the multi-soil-layering reactor. Soil, natural zeolite, and iron slag were used as a supporting media of multi-soil-layering in this research. The purpose of natural zeolite addition was to maintain the consistent ammonium exchange capacity by providing a sequential environment, and that of iron slag addition was to remove phosphorus by adsorption. Continuous experiment of lab-scale single-soil-layering (S-1), multi-soil-layering (S-2), and mixed-soil-layering (S-3) methods were studied to compare and optimize three different types of the reactors. The organic removal efficiencies showed more than 90% in all three reactors. While S-1 and S-3 reactors showed about T-N removal of 31%, 45%, respectively, the average T-N removal efficiency of the S-2 reactor represented an 87%. In conclusion, that results suggest that the multi-soil-layering reactor could be effectively utilized as a plant for treatment of small village sewage.

The Characteristics with HRT Variation on InSub Pilot Plant for Advanced Sewage Treatment

  • Kang, Jin-Young;Huh, Mock
    • Environmental Engineering Research
    • /
    • 제14권3호
    • /
    • pp.174-179
    • /
    • 2009
  • The InSub system(applied for a patent) was developed, as it combined the indirectly aerated submerged biofiltration(InSub) reactor and Anaerobic/ Anoxic reactor. This system which can eliminate organism and nutrient materials at the same time, which is safe and economical to be maintained and managed is more simple process than the complicated existing biological advanced sewage treatment system. The most suitable HRT of this study showed 9 hours. As looking into the effluent concentration and removal efficiency of each item at 9 hours of HRT, each effluent concentration for $SS,\;BOD5,\;COD_{Mn},\;and\;COD_{Cr}$ was 1.46 mg/L, 7,09 mg/L, 9.84 mg/L and 16.42 mg/L. And their removal efficiency was 96.98%. 90.59%, 77.18% and 83.92%, respectively. Each effluent concentration of T-N and T-P was 10.42 mg/L and 1.04 mg/L. Their removal efficiency was 73.38% and 61.62%, respectively. This pilot plant experiment(the state was without the internal recycling.) followed a variety of HRT. The results confirmed that it was to be advanced sewage treatment system with high efficiency when it combined with the internal recycling.

신경망 분석을 활용한 하수처리장 데이터 분석 기법 연구 (Wastewater Treatment Plant Data Analysis Using Neural Network)

  • 서정식;김태욱;이해각;윤종호
    • 한국환경과학회지
    • /
    • 제31권7호
    • /
    • pp.555-567
    • /
    • 2022
  • With the introduction of the tele-monitoring system (TMS) in South Korea, monitoring of the concentration of pollutants discharged from nationwide water quality TMS attachments is possible. In addition, the Ministry of Environment is implementing a smart sewage system program that combines ICT technology with wastewater treatment plants. Thus, many institutions are adopting the automatic operation technique which uses process operation factors and TMS data of sewage treatment plants. As a part of the preliminary study, a multilayer perceptron (MLP) analysis method was applied to TMS data to identify predictability degree. TMS data were designated as independent variables, and each pollutant was considered as an independent variables. To verify the validity of the prediction, root mean square error analysis was conducted. TMS data from two public sewage treatment plants in Chungnam were used. The values of RMSE in SS, T-N, and COD predictions (excluding T-P) in treatment plant A showed an error range of 10%, and in the case of treatment plant B, all items showed an error exceeding 20%. If the total amount of data used MLP analysis increases, the predictability of MLP analysis is expected to increase further.

갈대(Phragmites australls)수초를 적용한 바이오필터에서의 하수처리시설 악취저감기술 (Odor Reduction Technology in Sewage Treatment Facility Using Biofilter with Reed Grass(Phragmites australls))

  • 정진도;김규열
    • 상하수도학회지
    • /
    • 제27권3호
    • /
    • pp.373-382
    • /
    • 2013
  • In this study, a biological odor treatment system was proposed to remove odor(foul smell) materials causing several problems in the closed sewage treatment plant. This odor treatment system was composed of a two-step biofilter system in one reactor. The two-step biofilter reactor was constructed with natural purification layer in upper part and artificial purification layer in lower part. The reed grasses of water purification plants were planted in the surface area and mixed porous ceramic media were filled with the lower part of biofilter reactor. By using the above experimental apparatus, the ammonia gas removal efficiency was attained to 98.3 % and the hydrogen sulfide gas removal efficiency was appeared more than 97.7 % which shows more effective than the conventional odor removal process.

오염처리장의 처리효율 개선연구 (A Study on Improvement of Sewage Treatment System)

  • 성일화
    • 한국환경보건학회지
    • /
    • 제19권3호
    • /
    • pp.36-40
    • /
    • 1993
  • The objective of this research was to retrofit an on-site sewage treatment system suitable to current situation of Korea to reduce the pollution loading and preserve the invaluable water resources. Operation at the F/M ratio of 0.1 kg. BOD/kg MLSS day showed 87.1% BOD removal efficiency and 84.5% COD removal efficiency, and its effluent concentration was 6.4 mg/l as BOD and 21.7 mg/l as COD. Average removal of total nitrogen showed high removal efficiency of 80%.

  • PDF

미량오염물질 관리를 위한 산화 및 흡착 기반 하수 방류수 강화처리 기술의 연구 동향 및 시사점 (Enhanced sewage effluent treatment with oxidation and adsorption technologies for micropollutant control: current status and implications)

  • 최상기;이웅배;김영모;홍석원;손희종;이윤호
    • 상하수도학회지
    • /
    • 제36권2호
    • /
    • pp.59-79
    • /
    • 2022
  • Conventional wastewater treatment plants (WWTPs) do not fully remove micropollutants. Enhanced treatment of sewage effluents is being considered or implemented in some countries to minimize the discharge of problematic micropollutants from WWTPs. Representative enhanced sewage treatment technologies for micropollutant removal were reviewed, including their current status of research and development. Advanced oxidation processes (AOPs) such as ozonation and UV/H2O2 and adsorption processes using powdered (PAC) and granular activated carbon (GAC) were mainly discussed with focusing on process principles for the micropollutant removal, effect of process operation and water matrix factors, and technical and economic feasibility. Pilot- and full-scale studies have shown that ozonation, PAC, and GAC can achieve significant elimination of various micropollutants at economically feasible costs(0.16-0.29 €/m3). Considering the current status of domestic WWTPs, ozonation and PAC were found to be the most feasible options for the enhanced sewage effluent treatment. Although ozonation and PAC are all mature technologies, a range of technical aspects should be considered for their successful application, such as energy consumption, CO2 emission, byproduct or waste generation, and ease of system construction/operation/maintenance. More feasibility studies considering domestic wastewater characteristics and WWTP conditions are required to apply ozonation or PAC/GAC adsorption process to enhance sewage effluent treatment in Korea.

하수도 업무추진체계 개선 (Improvement of Sewerage Treatment System)

  • 이찬희
    • 수도
    • /
    • 제24권5호통권86호
    • /
    • pp.5-15
    • /
    • 1997
  • This year the Ministry of Environment(MOE) made a fifth amendment to the Sewerage Act, which was enacted in August 1966. The first objective of this amendment is to introduce small public sewerage system that is designed to treat wastewater produced in rural areas. Before small public sewerage system was introduced to the Act through this amendment, only urban areas were covered by public sewerage system. Because small sewerage system was introduced, wastewater generated in urban areas as well as rural areas can now be treated by public sewage treatment plants. In addition to this, some authorities on sewerage affairs were moved from the MOE to local governments by this amendment in order to enhance the power and responsibility of local governments in relation to sewerage affairs. Also, this amendment enabled local governments to entrust the authority to establish and manage sewage treatment plants to private companies, and enabled the MOE to organize an advisory committee on sewerage to review economic and technical aspects ofsewage treatment plants. This amendment went into effect September 8, 1997.

  • PDF

음식물찌꺼기 산발효산물과 하수슬러지의 혼합비 및 유기물부하가 병합처리에 미치는 영향 (Effects of Mixing Ratio and Organic Loading Rate of Acid Fermented Food Wastes and Sewage Sludge on the Anaerobic Digestion Process)

  • 안철우;박진식;장성호
    • 한국환경농학회지
    • /
    • 제25권3호
    • /
    • pp.247-256
    • /
    • 2006
  • 본 연구에서는 실험실 규모의 혐기성 소화 실험을 통하여 고온산발효를 거친 음식물찌꺼기 산발효액과 하수슬러지의 적정 혼합비와 유기물 부하율에 따른 반응조 운전특성을 분석하여 실제 플랜트에 적용가능성을 검토하여 얻은 결론은 다음과 같다. 음식물지꺼기 고온 산발효액과 하수슬러지를 혼합하여 반연속식으로 혐기성 소화실험을 실시한 결과 유기물 부하율 3.3 gVS/L.d(혼합비 1:1)에서 최적인 것으로 평가되었는데, 이때 SCOD 제거효율은 평균 74.2%, VS 제거효율은 73.6%, 주입된 VS당 생성된 가스량은 $0.440{\ell}/g\;Vs_{add}.d$였으며 평균 메탄 함량은 66.5%로 나타났다. 이는 기존에 음식물찌꺼기를 하수처리장의 중온 소화조에서 처리할 때의 유기물 부하보다 높아 효율성, 경제성에서 유리한 것으로 판단되었다.

정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구 (A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process)

  • 국영롱;주재영;배윤선;이혜인;정인호;박철휘
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.595-601
    • /
    • 2010
  • It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.