• Title/Summary/Keyword: sewage drainage

Search Result 60, Processing Time 0.02 seconds

Analysis of Factors Affecting Peak Loading Coefficient of Sewer Works in Korea (우리나라 하수도시설의 첨두부하율 영향요소 분석)

  • Hyun, In-Hwan;Lee, Young-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.877-884
    • /
    • 2011
  • Although peak loading coefficient is one of critical design factors for sewer works, its detailed affecting factors were not analyzed because of limited data availability. This study analyzed the affecting factors on peak loading coefficient with plenty data obtained from several newly constructed sewer works. Simple and multiple regression analysis methods were adopted to analyze the relationships of each variable with or without data filtering. Drainage population, drainage area, population density, and daily sewage flow per person showed very weak relationships under diverse characteristics of cities. However, daily sewage flow per person showed stronger relationships with peak loading when daily sewage flow per person was splitted into two ranges. Population density (i.e., drainage population divided by drainage area) and daily sewage flow per person considerably were related with peak loading coefficient when daily sewage flow per person is less than about 400 Lpcd.

산성광산폐수 처리를 위한 반응벽체의 반응물질로서 산업부산물 적용에 관한 연구

  • 한완수;최재규;이재영;최상일
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.260-265
    • /
    • 2004
  • Acid mine drainage(AMD) is one of the most serious environmental concerns associated with the mining industry around the world. The objective of this study is to assess the potential of sewage sludge as a carbon source for sulfate reducing bacteria and waste lime and steel slag as a neutralize agent for acid mine drainage bioremediation for use in permeable reactive materials. The study was performed using synthetic AMD in six column experiments. The effluent solution was systematically analysed throughout the experiments. The results of the study indicated that sewage sludge, waste lime and steel slag were the most effective for the AMD treatment as a permeable reactive materials.

  • PDF

Detection and phylogenetic analysis of norovirus from individual septic tanks in the drainage basin of the coastal area located in the Jaran Bay of Korea

  • Ham, In Tae;Kim, Byeo Ri;Park, Yu Jeong;Jung, Yeun Joong;Park, Kunbawui;Kwon, Ji Young;Mok, Jong Soo;Yu, Hongsik
    • Fisheries and Aquatic Sciences
    • /
    • v.24 no.1
    • /
    • pp.10-18
    • /
    • 2021
  • Norovirus (NoV) prevalence was investigated in 100 sewage samples collected from 35 individual septic tanks around the drainage basin of Jaran Bay, Korea in January, May, and July of 2017. Genotypes and diversity of NoV strains detected in sewage samples were also assessed using the conventional RT-PCR and phylogenetic analysis. NoV GI or GII were detected in 22 (22.0%) and 24 (24.0%) samples, respectively. Thirteen genotypes were identified with three dominant genotypes (GI.9, GII.5 and GII.17) and GII.17 showed relatively higher prevalence during the survey period. GII.17 strains were clustered into recombinant type variant or NoV GII.17 Kawasaki variant. NoV GII.17 strains were considered emergent epidemic variants with widespread circulation. NoV surveillance strategy should include both environmental (sewage) and clinical data to reveal minor NoV genotypes likely cause of asymptomatic or underreported infections in the local population.

Climate change effect on storm drainage networks by storm water management model

  • Hassan, Waqed Hammed;Nile, Basim Khalil;Al-Masody, Batul Abdullah
    • Environmental Engineering Research
    • /
    • v.22 no.4
    • /
    • pp.393-400
    • /
    • 2017
  • One of the big problems facing municipalities is the management and control of urban flooding where urban drainage systems are under growing pressure due to increases in urbanization, population and changes in the climate. Urban flooding causes environmental and infrastructure damage, especially to roads, this damage increasing maintenance costs. The aim of the present study is to develop a decision support tool to identify the performance of storm networks to address future risks associated with climate change in the Middle East region and specifically, illegal sewer connections in the storm networks of Karbala city, Iraq. The storm water management model has been used to simulate Karbala's storm drainage network using continuous hourly rainfall intensity data from 2008 to 2016. The results indicate that the system is sufficient as designed before consideration of extra sewage due to an illegal sewer connection. Due to climate changes in recent years, rainfall intensity has increased reaching 33.54 mm/h, this change led to flooding in 47% of manholes. Illegal sewage will increase flooding in the storm system at this rainfall intensity from between 39% to 52%.

Effect of municipal sludge from drainage facility on foul smell (도시내 배수설비 슬러지가 악취에 미치는 영향 연구)

  • Yu, Dae-Hyun;Park, Jihoon;Lee, Yong-Hoon;Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.315-324
    • /
    • 2014
  • The residents' odor complaint is steadily increasing by odor causing from sewage system. A current drainage facilities and septic tank are included in the individual sewerage according to Sewerage Act. However, definitions and legal standards of drainage tank are insufficient. In addition, specifications and maintenance standards related to structure and size are not established. In this research, effect of drainage tank in individual sewage facilities on the odor occurrence was studied and the concentrations of $H_2S$ and composite odor were measured. From the measurements, the concentration of $H_2S$ and composite odor were 1 ppm ~ 5 ppm and 1.04 OU ~ 4.05 OU, respectively, before pump operation. Also, the concentration of $H_2S$ and composite odor were 5 ppm ~ 33 ppm and 5.10 OU ~ 35.04 OU, respectively, after pump operation. The concentration of SS in the effluent from drainage tank was ranged from 840 mg/L to 1,980 mg/L. These high concentration of SS seemed to be the major source of foul smell when high concentrated suspended solids in the public sewerage system were decomposed and then emitted. In this research, correlation coefficient ($R^2$) between $H_2S$ and composite odor before and after pumping were 0.925 and 0.918, respectively.

Analysis of Land Subsidence Risk Factors Considering Hydrological Properties, Geomorphological Parameters, and Population Distribution (수문 및 지형특성과 인구분포를 고려한 지반침하 발생 평가인자 분석)

  • Ye-Yeong Lee;Dahae Lee;Eun-Ji Bae;Chung-Mo Lee;Hanna Choi
    • Journal of Soil and Groundwater Environment
    • /
    • v.28 no.6
    • /
    • pp.45-57
    • /
    • 2023
  • To assess land subsidence estimation and preparedness in the Geum River basin, this study applied GIS techniques and identified six key areas. The Geum River basin has experienced an increase in heavy rainfall since late 2010, and four study areas have shown an increase in groundwater levels. Land subsidence primarily occurred from June to September, with higher rainfall years in 2020 and 2023. Approximately 83.6% of land subsidence in Chungcheongbuk-do province occurred in Cheongju-si, mainly attributed to aging sewage pipes. The regions experiencing population growth have likely led to the construction of underground infrastructures and sewer pipes. Thus, it is considered that various factors, including sewage pipe leaks, precipitation, slope gradient, low drainage density, and groundwater level fluctuations, have contributed to land subsidence. Improving land subsidence estimation involves incorporating additional natural factors and human activities.

Consolidation Analysis of Geotextile Tubes Filled with Highly Compressible Sludge Using Variable Coefficients of Consolidation

  • Kim, Hyeongjoo;Kim, Hyeongsoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.12
    • /
    • pp.25-32
    • /
    • 2021
  • Geotextile tube technology has been perceived as an economical solution for liquid sludge treatment, and analyzing its consolidation behavior is necessary to be able to evaluate the dewatering capabilities of large geotextile tubes filled with contaminated soil, tailings, sewage sludge, and so on. The objectives of this study are to present a method that can adequately convey the consolidation behavior of geotextile tubes filled with sewage sludge, and to investigate the effects of various geotextile tube consolidation parameters. In this study, variable coefficients of consolidation are utilized to analyze the consolidation process of geotextile tubes filled with sewage sludge. The consolidation solution was verified by comparing the measured and predicted data from a hanging bag test conducted in the literature. After verifying the proposed solution, the consolidation parameters of a geotextile tube composed of a woven polypropylene outer layer and a non-woven polypropylene layer filled sewage sludge were obtained. Using the obtained parameters, the consolidation behavior of a large-scale composite geotextiles tube was predicted.