• 제목/요약/키워드: series-parallel system

검색결과 416건 처리시간 0.028초

단기 시계열 제품의 전이함수를 이용한 수요예측과 마케팅 정책에 미치는 영향에 관한 연구 (A Study on the Demand Forecasting by using Transfer Function with the Short Term Time Series and Analyzing the Effect of Marketing Policy)

  • 서명율;이종태
    • 산업공학
    • /
    • 제16권4호
    • /
    • pp.400-410
    • /
    • 2003
  • Most of the demand forecasting which have been studied is about long-term time series over 15 years demand forecasting. In this paper, we set up the most optimal ARIMA model for the short-term time series demand forecasting and suggest demand forecasting system for short-term time series by appraising suitability and predictability. We are going to use the univariate ARIMA model in parallel with the bivariate transfer function model to improve the accuracy of forecasting. We also analyze the effect of advertisement cost, scale of branch stores, and number of clerk on the establishment of marketing policy by applying statistical methods. After then we are going to show you customer's needs, which are number of buying products. We have applied this method to forecast the annual sales of refrigerator in four branch stores of A company.

2중 컨버터 구조를 갖는 계통 연계형 UPS의 DC 충전 알고리듬에 관한 연구 (A Study on DC Changing Algorithm of the Line-Interactive UPS with Dual Converter Structure)

  • 이우철;유동상
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.27-34
    • /
    • 2005
  • 본 논문에서는 2개의 컨버터 구조를 갖는 삼상 계통 연계형 UPS에 대하여 연구한다. 삼상UPS시스템은 2개의 능동 전력 보상기 구조로 이루어져 있다. 하나는 직렬형으로 .전원전압과 동상의 전압원으로 동작하여 전원전압의 변동, 왜곡시에도 정현파 전원전류와 고역률을 갖도록 동작한다. 병렬형은 전원전압과 위상을 맞춘 종전의 정현파 전압원으로 동작하여 부하에 안정되고 낮은 THD를 갖는 정현파 전압을 공급한다. 본 논문에서는 직렬형, 병렬형 능동보상기에서 전원전압의 크기에 따라 충전 방법에 대하여 제시한다. 종전의 계통 연계형 UPS는 DC 충전과 출력전압을 동시에 제어하였는데, 2개의 컨버터 구조를 갖는 UPS 시스템에서는 직렬형 보상기도 DC 충전을 할 수 있어 직렬형과 병렬형을 사용한 충전 알고리듬을 연구할 필요가 있다. 따라서 DC link단의 전압을 안정시켜 본래의 직렬형, 병렬형 구조의 보상기의 안정성 향상에 기여할 수가 있다. 제안된 방법의 타당성은 시뮬레이션과 실험 결과를 통하여 입증된다.

A Hybrid Metaheuristic for the Series-parallel Redundancy Allocation Problem in Electronic Systems of the Ship

  • Son, Joo-Young;Kim, Jae-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.341-347
    • /
    • 2011
  • The redundancy allocation problem (RAP) is a famous NP.complete problem that has beenstudied in the system reliability area of ships and airplanes. Recently meta-heuristic techniques have been applied in this topic, for example, genetic algorithms, simulated annealing and tabu search. In particular, tabu search (TS) has emerged as an efficient algorithmic approach for the series-parallel RAP. However, the quality of solutions found by TS depends on the initial solution. As a robust and efficient methodology for the series-parallel RAP, the hybrid metaheuristic (TSA) that is a interactive procedure between the TS and SA (simulated annealing) is developed in this paper. In the proposed algorithm, SA is used to find the diversified promising solutions so that TS can re-intensify search for the solutions obtained by the SA. We test the proposed TSA by the existing problems and compare it with the SA and TS algorithm. Computational results show that the TSA algorithm finds the global optimal solutions for all cases and outperforms the existing TS and SA in cases of 42 and 56 subsystems.

PLL을 이용한 공진부하 MOSFET 인버어터의 주파수 추종제어계 (Frequency Follow-up Control System of Resonant Load MOSFET Inverter using PLL)

  • Kim, Joon-Hong;Joong-Hwan kim
    • 대한전기학회논문지
    • /
    • 제35권7호
    • /
    • pp.272-277
    • /
    • 1986
  • The system that follows to the resonance frequency of high frequency MOSFET inverter and varies according to the changes of load characteristics is proposed. Also we suggested a method how to select the resonant load type between series and parallel circuit for a given inverter type. It leads to the conclusion that in the case of high impedance loads, parallel resonant circuits are preferable, on the other hand, for low impedance loads, series resonant circuits are more preferable. For frequency tracking, a PLL circuit is used as main control element to detect the phase difference of current and voltage of load. The realized apparatus composed of control circuit and voltage type full-bridged MOSFET elements as main parts of inverter. A stable frequency follow-up characteristics are obtained for 1.2MHz, 1.5KW high frequency output and power is always supplied to the load with unity power factor.

  • PDF

직렬-병렬 시스템의 중복 설계 문제의 전역 최적화 해법에 관한 연구 (A Study on A Global Optimization Method for Solving Redundancy Optimization Problems in Series-Parallel Systems)

  • 김재환;유동훈
    • 해양환경안전학회지
    • /
    • 제6권1호
    • /
    • pp.23-33
    • /
    • 2000
  • This paper is concerned with finding the global optimal solutions for the redundancy optimization problems in series-parallel systems related with system safety. This study transforms the difficult problem, which is classified as a nonlinear integer problem, into a 0/1 IP(Integer Programming) by using binary integer variables. And the global optimal solution to this problem can be easily obtained by applying GAMS (General Algebraic Modeling System) to the transformed 0/1 IP. From computational results, we notice that GA(Genetic Algorithm) to this problem, which is, to our knowledge, known as a best algorithm, is poor in many cases.

  • PDF

고조파 전류원에 의한 콘덴서 임피던스 특성 해석 (Analysis of Impedance Performance for Condenser by Harmonic Current Source)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.

Multiple-Mode Structural Vibration Control Using Negative Capacitive Shunt Damping

  • Park, Chul-Hue;Park, Hyun-Chul
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1650-1658
    • /
    • 2003
  • This paper deals with a novel shunt circuit, which is capable of suppressing multimode vibration amplitudes by using a pair of piezoceramic patches. In order to describe the characteristic behaviors of a piezoelectric damper connected with a series and a parallel resistor-negative capacitor branch circuit, the stiffness ratio and loss factor with respect to the non-dimensional frequency are considered. The mechanism of the shunt damper is also described by considering a shunt voltage constrained by shunt impedance. To obtain a guideline model of the piezo/beam system with a negative capacitive shunting, the governing equations of motion are derived through the Hamilton's principle and a piezo sensor equation as well as a shunt-damping matrix is developed. The theoretical analysis shows that the piezo/beam system combined with a series and a parallel resistor-negative capacitor branch circuit developed in this study can significantly reduce the multiple-mode vibration amplitudes over the whole structural frequency range.

슈퍼커패시터를 이용한 전기차량용 회생제동 에너지 저장장치 개발 (Development of Regenerative Energy Storage System for An Electric Vehicle Using Super-Capacitors)

  • 정대원
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.544-551
    • /
    • 2011
  • This paper presents the circuit arrangement and effective control method of regenerative energy storage system for an electric vehicle using super-capacitors as the braking energy storage element. A bi-directional controlled current flow of the DC-DC converters with the capacitor bank is connected in parallel with battery, and is controlled so that the whole of the braking energy is effectively absorbed into the capacitors and released back to the electric motor upon acceleration. The converter needs the series-parallel switching circuit for making the best use of the series capacitors and for limiting the step-up ratio of the boost converter. The proposed methods are verified by computer simulation and experimental set-up. They are usefully applied to the electric vehicles such as green cars, electric motorcycles, bike, etc which are power- supplied by the electric batteries.

$\cdot$병렬 공진형컨버터를 이용한 비접촉전원 (Contact-less Power Supply Using Series-Parallel Rasonant Converter)

  • 김은수;구대현;김종무;강도현;신병철;공영수;양승철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.103-107
    • /
    • 2002
  • A contact-less power supply system (CPS) allows electrical energy to supply to mobile consumers without any electrical or mechanical contact. CPS works in the same principle as a transformer, with the track litz cable forming the primary circuit and the pickup as the secondary. The track power supply generates the high frequency alternating current in the track cable. The captured AC magnetic field generated by the track conductors produces electrical energy in the pickup coil and the pickup rectifier converts the high frequency AC power to DC while regulating the power to the load. This paper presents the theoretical analysis, simulation and experiment리 results of the series-parallel resonant converter working as contact-less power supply system.

  • PDF

Sabotage of Intruder Alarm System Loop

  • Karel Burda
    • International Journal of Computer Science & Network Security
    • /
    • 제23권7호
    • /
    • pp.23-31
    • /
    • 2023
  • This article discusses the sabotage of loops of intruder alarm systems. Although loop alarm systems are now gradually being replaced by digital alarm systems, they are still significantly present in practice. This paper describes two experimentally verified techniques for sabotaging balanced loops. The first technique is based on the jump replacement of the balancing resistor by a fake resistor. The second technique is based on inserting a series-parallel combination of two rheostats into the loop. By alternately changing the resistance of these rheostats, a state is reached where the balancing resistor is shorted by the parallel rheostat and replaced by the series rheostat. Sabotage devices for both attacks are technically simple and inexpensive, so they can be made and used by an amateur. Owners of loop alarm systems should become find out about this threat.