• 제목/요약/키워드: serial arrangement

검색결과 20건 처리시간 0.024초

연속간행물 관리에 적용되는 업무조직 구조의 유형 (Organizational patterns for serial management)

  • 구자영
    • 한국문헌정보학회지
    • /
    • 제12권
    • /
    • pp.87-120
    • /
    • 1985
  • The present study aims at identifying the nature of the organizational patterns for serial management and thus providing an assitance for decision-making in regards to how the serials in an individual library be processed. The premise of the paper is that effective management is ensued from adopting proper organizational arrangement. In the first part. attempts are made to bring to the fore the problems inherent in serial management and the efforts made for possible solutions. The main portion of the paper eximines the two outstanding patterns; namely, the decentralized arrangement patterned after the traditional functions of a library and the centralized one integrating such functions as acquisition, cataloging and information service. Both are examined in light of nature, development, applicability, strengths and weeknesses. Automation is viewed as a strong force for a change in organizing serial work as it has already brought about organizational change in some large libraries. The general conclusion is that a large collection(5,000 active titles or more) has much to benefit from a separate, specialized department. which integrates the related functions; and the smaller collection can be effectively treated like the rest of the library materials, assigning a specific unit responsible for serial work and promoting an informal communication activities which would bring about coordination and coorperation for the free flow of serial work.

  • PDF

현장시험에 의한 소수력발전용 튜블러수차시스템 성능계측 (Performance Measurement of a Tubular Type Turbine System for Small Hydropower by Field Test)

  • 황영호;이영호;최영도
    • 한국유체기계학회 논문집
    • /
    • 제14권6호
    • /
    • pp.5-10
    • /
    • 2011
  • Recently, small hydropower attracts attention because of its renewable, clean and abundant energy resources to develop. Therefore, a tubular type hydro turbine is proposed for small hydropower in this study because the turbine has relatively simple structure and high possibility of applying to small hydropower. The purpose of this study is to investigate the performance characteristics of the turbine by field test. Field test iss conducted using one tubular turbine system as well as serial arrangement system by two tubular turbines taking into consideration of actual operation conditions. The results show that efficiency of test turbine changes considerably by the runner vane angle. Best efficiency of one turbine arrangement is higher than that of two turbine serial arrangement.

저전압 대변위 고정도 구동을 위한 근육모사 직렬연결 디지털 구동기 (Muscle-Inspired Serially-Connected Digital Actuators for Low-Voltage, Wide-Range, High-Precision Displacement Control)

  • 이재용;이원철;조영호
    • 대한기계학회논문집A
    • /
    • 제32권1호
    • /
    • pp.1-6
    • /
    • 2008
  • This paper presents muscle-inspired serial digital actuators, achieving the improvement of the range-to-precision and range-to-voltage performance. We propose a weight-balanced design for the serial actuators with serpentine springs using serial arrangement of digital actuators. We have measured the displacement range, precision, and drive voltage at unit and serial actuation of 1Hz. The serial digital actuators produce a full range displacement of $28.44{\pm}0.02{\mu}m$, accumulating the unit displacement of $2.8{\pm}0.5{\mu}m$ at the operating voltage of $4.47{\pm}0.07V$. In addition, the serial digital actuators having the displacement precision of $37.94{\pm}6.26nm$ do not accumulate the precision of the unit actuators, $36.0{\pm}17.7nm$. We experimentally verify that the serial digital actuators achieve the range-to-squared-voltage ratio of $1.423{\mu}m/V^2$ and the range-to-precision ratio of 749.6.

Taxonomic Considerations on the Bast Fibres in the Genus Sida L. (Malvaceae) in Nigeria

  • Oladele, F.A.
    • Journal of Plant Biology
    • /
    • 제29권2호
    • /
    • pp.135-143
    • /
    • 1986
  • The distributional pattern of the bast fibres strands or bundles in the stems of Sida species represented in Nigeria is studied. Three major patterns of arrangement are recognized, namely aggregation of fibre strands into units with wedge-shaped, or triangular, rectangular, rhomboidal, square and trapezoid outlines; serial arrangement of fibre strands into rings or circular, ovoid, semi-circular or crescentic rows; and intermediate pattern in which both fibre strands-aggregates and serial rows of strands patterns are combined. The first pattern is found in S. linifolia, S. urens and S. scabrida, the second in S. cordifolia, S. pilosa, S. ovata, S. rhombifolia and S. spinosa, and the third in S. garckeana, and S. acuta. A dichotomous key based on these features is presented. Dimensional characteristics of the bast fibre cells are also given.

  • PDF

팽창실과 파퍼 실린더의 배열형태에 따른 복합소호 모델 가스차단부의 열적회복특성 비교 (Comparison of Thermal Recovery Characteristics of Hybrid Type Model Gas Interrupters According to the Arrangement of Thermal Expansion Chamber and Puffer Cylinder)

  • 송기동;정진교;박경엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권12호
    • /
    • pp.725-731
    • /
    • 2004
  • In this study, the three type hybrid interrupters according to the arrangement of the thermal expansion chamber and the puffer cylinder(they are called 'serial type', 'parallel/exchanged type', and 'parallel/separated type' respectively in this work) were designed and manufactured. This paper presents the tested results of the thermal recovery characteristics on the interrupters using a simplified synthetic test facility. The 'serial type' hybrid interrupter which is to obtain more easily the pressure rise for the thermal recovery compared with the others has the best capability in the thermal recovery characteristics. In order to investigate the stress on the operating mechanism, the distortion of the stroke wave in on-load test was examined to the stroke curve in no-load test. The biggest distortion was occurred in the 'parallel/exchanged type' hybrid interrupter. Finally, the small interruption capability on the three type interrupters was estimated by a theoretical form and the 'parallel/separated type' hybrid interrupter has the advantage of the others in the view of structure.

Triple rail-coding 입력과 기호치환을 이용한 변형부호화자리수 가산기 구현 (Implementation of the modified-signed digit(MSD) number adder using triple rail-coding input and symbolic substitution)

  • 신창목;김수중;서동환
    • 대한전자공학회논문지SD
    • /
    • 제41권6호
    • /
    • pp.43-51
    • /
    • 2004
  • 본 논문에서는 입력패턴을 triple rail-coding 방식으로 표현한 후 입력의 직렬연결 방법으로 기호치환을 수행하는 광 병렬 변형부호화자리수 가산 시스템을 제안하였다. Triple rail-coding 방식으로 변형부호화자리수 입력을 표현할 때 중복연산 결과가 나오는 입력들은 동일한 패턴으로 전처리하여 기호치환과정의 규칙수를 줄였고, 광 구현시 공간 이동된 입력패턴을 직렬로 연결하여 광을 통과시킴으로써 공간 이동 연산, NOR 연산, 그리고 문턱치 연산과정이 필요 없는 광 가산기를 구현하였다.

구형 3자유도 병렬 메커니즘의 기구학 해석 및 구현 (Kinematic Analysis and Implementation of a Spherical 3-Degree-of-Freedom Parallel Mechanism)

  • 이석희;김희국;오세민;소병록;이병주
    • 한국정밀공학회지
    • /
    • 제22권11호
    • /
    • pp.72-81
    • /
    • 2005
  • A new spherical-type 3-degree-of-freedom parallel mechanism consisting of a two degree-of-freedom parallel module and a serial module is proposed. Two alternative designs for the serial sub-chain are suggested and compared. The first design employs RU joint arrangement for the serial sub chain structure. The second design incorporates a gear chain to drive the distal revolute joint of the serial sub-chain from the base platform of the mechanism. This modification significantly improves kinematic characteristics of the mechanism within its workspace. Firstly, the closed-form solutions of both the forward and the reverse position analysis are derived. Secondly, the first-order kinematic model with respect to three inputs which are located at the base is derived. Thirdly, it is confirmed through simulation that the modified mechanism has much more improved isotropic characteristic throughout the workspace of the mechanism. Lastly, the proposed mechanism is implemented to verify the results from this analysis.

차단부 형태에 따른 소전류 차단성능 비교 (Comparison of Small Current Interruption Capability Depending on the Type of Interrupter)

  • 송기동;정진교;김홍규
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권7호
    • /
    • pp.362-368
    • /
    • 2006
  • This paper presents the results of a small capacitive current interruption test for the three types of interrupter which are called 'serial type', 'parallel/separated type' and 'puffer type' according to the arrangement of the thermal expansion chamber and the puffer cylinder. After the preconditioning test the small current interruption capability of the 'puffer type' decreased, on the contrary, that of the hybrid interrupters increased. A number of reignition have been occurred in the 'serial type' hybrid interrupter and the change of small current interruption capability after preconditioning test is mainly influenced by the structure of interrupter. Finally it has been proved that the 'parallel/separated type' hybrid interrupter has the best interruption performance through the verification tests.

A new insight into design of acoustic liner arrays arrangement in the presence of a grazing flow

  • Hadi Dastourani ;Iman Bahman-Jahromi
    • Advances in Computational Design
    • /
    • 제8권4호
    • /
    • pp.273-293
    • /
    • 2023
  • This study evaluated the acoustic performance of two configurations of serial HR arrays and lined HR arrays in the presence of grazing flow using a 3D numerical simulation. The dual, triple, and quad HR arrays were compared to the conventional HR array. The simulation results showed that the number of resonant frequencies increased with the number of serial HR arrays. The CTL did not significantly change with the number of serial HR arrays. The acoustic performance of the two, three, and four-lined HR arrays was compared to the conventional HR array. The results showed that the resonant frequency and TLmax increased with the number of lined HR arrays. The CTL also increased with the number of lined HR arrays. The effect of the grazing flow Mach number (Ma) was investigated on the four-lined HR array configuration and compared to the conventional HR configuration. TLmax and CTL decreased for both configurations with increasing Ma. The four-lined HR array configuration had significantly better acoustic performance than the conventional HR configuration. The TLmax and CTL increased by more than 300% when the configuration was changed from the conventional HR to the four-lined HR array at Ma = 0.The increment percentage decreased with increasing Ma.

관류형 증기발생기를 사용한 복합발전용 초임계압 하부시스템의 성능 설계해석 (Performance Design Analysis of the Supercritical Pressure Bottoming System of Combined Cycle Power Plants Using Once-Through Steam Generator)

  • 양진식;김동섭;노승탁
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1370-1377
    • /
    • 2002
  • This study analyzed the design performance of the bottoming system of combined cycle power plants using a once-through heat recovery steam generator. For a parallel arrangement of the main heater and reheater, parametric analyses were carried out to present the criteria for determining the reheater pressure and the location of the starting point of the reheater in the HRSG. The performance of the bottoming system was presented fer a range from high subcritical to supercritical pressure. The steam turbine power is as high as that of conventional triple-pressure bottoming systems. The serial arrangement of heat exchangers with division of each heater into several segments can achieve similar power level.