• Title/Summary/Keyword: serial arrangement

Search Result 20, Processing Time 0.02 seconds

Organizational patterns for serial management (연속간행물 관리에 적용되는 업무조직 구조의 유형)

  • Koo Jayoung
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.12
    • /
    • pp.87-120
    • /
    • 1985
  • The present study aims at identifying the nature of the organizational patterns for serial management and thus providing an assitance for decision-making in regards to how the serials in an individual library be processed. The premise of the paper is that effective management is ensued from adopting proper organizational arrangement. In the first part. attempts are made to bring to the fore the problems inherent in serial management and the efforts made for possible solutions. The main portion of the paper eximines the two outstanding patterns; namely, the decentralized arrangement patterned after the traditional functions of a library and the centralized one integrating such functions as acquisition, cataloging and information service. Both are examined in light of nature, development, applicability, strengths and weeknesses. Automation is viewed as a strong force for a change in organizing serial work as it has already brought about organizational change in some large libraries. The general conclusion is that a large collection(5,000 active titles or more) has much to benefit from a separate, specialized department. which integrates the related functions; and the smaller collection can be effectively treated like the rest of the library materials, assigning a specific unit responsible for serial work and promoting an informal communication activities which would bring about coordination and coorperation for the free flow of serial work.

  • PDF

Performance Measurement of a Tubular Type Turbine System for Small Hydropower by Field Test (현장시험에 의한 소수력발전용 튜블러수차시스템 성능계측)

  • Hwang, Yeong-Ho;Lee, Young-Ho;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.6
    • /
    • pp.5-10
    • /
    • 2011
  • Recently, small hydropower attracts attention because of its renewable, clean and abundant energy resources to develop. Therefore, a tubular type hydro turbine is proposed for small hydropower in this study because the turbine has relatively simple structure and high possibility of applying to small hydropower. The purpose of this study is to investigate the performance characteristics of the turbine by field test. Field test iss conducted using one tubular turbine system as well as serial arrangement system by two tubular turbines taking into consideration of actual operation conditions. The results show that efficiency of test turbine changes considerably by the runner vane angle. Best efficiency of one turbine arrangement is higher than that of two turbine serial arrangement.

Muscle-Inspired Serially-Connected Digital Actuators for Low-Voltage, Wide-Range, High-Precision Displacement Control (저전압 대변위 고정도 구동을 위한 근육모사 직렬연결 디지털 구동기)

  • Lee, Jae-Yong;Lee, Won-Chul;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • This paper presents muscle-inspired serial digital actuators, achieving the improvement of the range-to-precision and range-to-voltage performance. We propose a weight-balanced design for the serial actuators with serpentine springs using serial arrangement of digital actuators. We have measured the displacement range, precision, and drive voltage at unit and serial actuation of 1Hz. The serial digital actuators produce a full range displacement of $28.44{\pm}0.02{\mu}m$, accumulating the unit displacement of $2.8{\pm}0.5{\mu}m$ at the operating voltage of $4.47{\pm}0.07V$. In addition, the serial digital actuators having the displacement precision of $37.94{\pm}6.26nm$ do not accumulate the precision of the unit actuators, $36.0{\pm}17.7nm$. We experimentally verify that the serial digital actuators achieve the range-to-squared-voltage ratio of $1.423{\mu}m/V^2$ and the range-to-precision ratio of 749.6.

Taxonomic Considerations on the Bast Fibres in the Genus Sida L. (Malvaceae) in Nigeria

  • Oladele, F.A.
    • Journal of Plant Biology
    • /
    • v.29 no.2
    • /
    • pp.135-143
    • /
    • 1986
  • The distributional pattern of the bast fibres strands or bundles in the stems of Sida species represented in Nigeria is studied. Three major patterns of arrangement are recognized, namely aggregation of fibre strands into units with wedge-shaped, or triangular, rectangular, rhomboidal, square and trapezoid outlines; serial arrangement of fibre strands into rings or circular, ovoid, semi-circular or crescentic rows; and intermediate pattern in which both fibre strands-aggregates and serial rows of strands patterns are combined. The first pattern is found in S. linifolia, S. urens and S. scabrida, the second in S. cordifolia, S. pilosa, S. ovata, S. rhombifolia and S. spinosa, and the third in S. garckeana, and S. acuta. A dichotomous key based on these features is presented. Dimensional characteristics of the bast fibre cells are also given.

  • PDF

Comparison of Thermal Recovery Characteristics of Hybrid Type Model Gas Interrupters According to the Arrangement of Thermal Expansion Chamber and Puffer Cylinder (팽창실과 파퍼 실린더의 배열형태에 따른 복합소호 모델 가스차단부의 열적회복특성 비교)

  • Song Ki-Dong;Chong Jin-Kyo;Park Kyong-Yop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.12
    • /
    • pp.725-731
    • /
    • 2004
  • In this study, the three type hybrid interrupters according to the arrangement of the thermal expansion chamber and the puffer cylinder(they are called 'serial type', 'parallel/exchanged type', and 'parallel/separated type' respectively in this work) were designed and manufactured. This paper presents the tested results of the thermal recovery characteristics on the interrupters using a simplified synthetic test facility. The 'serial type' hybrid interrupter which is to obtain more easily the pressure rise for the thermal recovery compared with the others has the best capability in the thermal recovery characteristics. In order to investigate the stress on the operating mechanism, the distortion of the stroke wave in on-load test was examined to the stroke curve in no-load test. The biggest distortion was occurred in the 'parallel/exchanged type' hybrid interrupter. Finally, the small interruption capability on the three type interrupters was estimated by a theoretical form and the 'parallel/separated type' hybrid interrupter has the advantage of the others in the view of structure.

Implementation of the modified-signed digit(MSD) number adder using triple rail-coding input and symbolic substitution (Triple rail-coding 입력과 기호치환을 이용한 변형부호화자리수 가산기 구현)

  • Shin, Chang-Mok;Kim, Soo-Joong;Seo, Dong-Hoan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.6
    • /
    • pp.43-51
    • /
    • 2004
  • An optical parallel modified signed-digit(MSD) number adder system is proposed by using triple rail-coding input patterns and serial arrangement method of symbolic substitution. By combing overlapped arithmetic results. which are produced by encoding MSD input as triple rail-coding patterns. into the same patterns, symbolic substitution rules are reduced and also by using serialized and space-shifted input patterns in optical experiments, the optical adder without space-shifting operation, NOR operation and threshold operation is implemented.

Kinematic Analysis and Implementation of a Spherical 3-Degree-of-Freedom Parallel Mechanism (구형 3자유도 병렬 메커니즘의 기구학 해석 및 구현)

  • Lee, Seok-Hee;Kim, Whee-Kuk;Oh, Se-Min;So, Byung-Rok;Yi, Byung-Ju
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.72-81
    • /
    • 2005
  • A new spherical-type 3-degree-of-freedom parallel mechanism consisting of a two degree-of-freedom parallel module and a serial module is proposed. Two alternative designs for the serial sub-chain are suggested and compared. The first design employs RU joint arrangement for the serial sub chain structure. The second design incorporates a gear chain to drive the distal revolute joint of the serial sub-chain from the base platform of the mechanism. This modification significantly improves kinematic characteristics of the mechanism within its workspace. Firstly, the closed-form solutions of both the forward and the reverse position analysis are derived. Secondly, the first-order kinematic model with respect to three inputs which are located at the base is derived. Thirdly, it is confirmed through simulation that the modified mechanism has much more improved isotropic characteristic throughout the workspace of the mechanism. Lastly, the proposed mechanism is implemented to verify the results from this analysis.

Comparison of Small Current Interruption Capability Depending on the Type of Interrupter (차단부 형태에 따른 소전류 차단성능 비교)

  • Song, Ki-Dong;Chong, Jin-Kyo;Kim, Hong-Kyu
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.7
    • /
    • pp.362-368
    • /
    • 2006
  • This paper presents the results of a small capacitive current interruption test for the three types of interrupter which are called 'serial type', 'parallel/separated type' and 'puffer type' according to the arrangement of the thermal expansion chamber and the puffer cylinder. After the preconditioning test the small current interruption capability of the 'puffer type' decreased, on the contrary, that of the hybrid interrupters increased. A number of reignition have been occurred in the 'serial type' hybrid interrupter and the change of small current interruption capability after preconditioning test is mainly influenced by the structure of interrupter. Finally it has been proved that the 'parallel/separated type' hybrid interrupter has the best interruption performance through the verification tests.

A new insight into design of acoustic liner arrays arrangement in the presence of a grazing flow

  • Hadi Dastourani ;Iman Bahman-Jahromi
    • Advances in Computational Design
    • /
    • v.8 no.4
    • /
    • pp.273-293
    • /
    • 2023
  • This study evaluated the acoustic performance of two configurations of serial HR arrays and lined HR arrays in the presence of grazing flow using a 3D numerical simulation. The dual, triple, and quad HR arrays were compared to the conventional HR array. The simulation results showed that the number of resonant frequencies increased with the number of serial HR arrays. The CTL did not significantly change with the number of serial HR arrays. The acoustic performance of the two, three, and four-lined HR arrays was compared to the conventional HR array. The results showed that the resonant frequency and TLmax increased with the number of lined HR arrays. The CTL also increased with the number of lined HR arrays. The effect of the grazing flow Mach number (Ma) was investigated on the four-lined HR array configuration and compared to the conventional HR configuration. TLmax and CTL decreased for both configurations with increasing Ma. The four-lined HR array configuration had significantly better acoustic performance than the conventional HR configuration. The TLmax and CTL increased by more than 300% when the configuration was changed from the conventional HR to the four-lined HR array at Ma = 0.The increment percentage decreased with increasing Ma.

Performance Design Analysis of the Supercritical Pressure Bottoming System of Combined Cycle Power Plants Using Once-Through Steam Generator (관류형 증기발생기를 사용한 복합발전용 초임계압 하부시스템의 성능 설계해석)

  • 양진식;김동섭;노승탁
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.10
    • /
    • pp.1370-1377
    • /
    • 2002
  • This study analyzed the design performance of the bottoming system of combined cycle power plants using a once-through heat recovery steam generator. For a parallel arrangement of the main heater and reheater, parametric analyses were carried out to present the criteria for determining the reheater pressure and the location of the starting point of the reheater in the HRSG. The performance of the bottoming system was presented fer a range from high subcritical to supercritical pressure. The steam turbine power is as high as that of conventional triple-pressure bottoming systems. The serial arrangement of heat exchangers with division of each heater into several segments can achieve similar power level.