• Title/Summary/Keyword: separator.

Search Result 743, Processing Time 0.033 seconds

Vibration Reduction Method for Discharge Line of Moisture Separator Reheater (습분분리재열기 배수관 진동저감방안)

  • 이준신;손석만;김태룡
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.688-694
    • /
    • 2001
  • The 84m discharge line of moisture separator reheater(MSR) in Kori-2 had been suffered by excessive vibration from the beginning of power generation. In 1993, a complementary measure was taken to reduce the vibration level by adding several supports in the MSR pipeline. However, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of MSR pipeline and the countermeasure for abnormal vibration was investigated. Among the several vibration reduction methods, piping layout change by smoothing the pipeline was applied to the MSR pipeline in Kori-2. Applying the countermeasure, the vibration level was found to dramatically reduce from 17cm/sec to l.0cm/sec at the full-power operation condition.

  • PDF

Magnetic Separation of FCC Equilibrium Catalyst by HGMS

  • Xiang, Fazhu;He, Pingbo;Chen, Jin
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.770-775
    • /
    • 2001
  • Effects of magnetic field and carrier gas velocity on the magnetic separation of FCC catalyst by a high gradient magnetic separator were studied. The activities of the equilibrium catalyst, the magnetic particles and the nonmagnetic particles were evaluated in a fixed bed microreactor The results showed that heavy metal contaminated catalyst can be selectively separated by means of high gradient magnetic separation at magnetic field 0.5T and carrier gas velocity 0.3m.s$^{-1}$ , and lightly metal contaminated catalyst retained high catalytic activity.

  • PDF

Numerical Study of Axial-flow Cyclone Cluster for Subway Station HVAC system (지하역사 공기조화기용 축류형 사이클론 클러스터의 수치해석적 성능 평가 연구)

  • Kim, Myeoung-Joon;Kim, Ho-Joong;Kim, Jin-Kwan;Kwon, Soon-Bark;Kim, Tae-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.757-761
    • /
    • 2009
  • Axial-flow cyclone separator cluster can be used for a dust removal device inside a heating, ventilation, and air conditioning(HVAC) system of subway station. In this study, 3-dimensional computational fluid dynamics(CFD) analysis was performed to compare single unit axial-flow cyclone with couple unit axial-flow cyclone cluster. It is shown that the performance of cyclone separator is not influenced by number of single units but influenced by ability of single unit.

  • PDF

The Study on the Technical Trends of ESS(Energy Storage System) (ESS(Energy Storage System) 기술동향에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Kwon, Soon-Do;Lee, Eun-Young;Cho, Kyu-Man;Eom, Tae-Min;Hong, Sung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.637-638
    • /
    • 2015
  • This paper review the technical trends of ESS(Energy Storage System). The ESS has been displaced by cathode, anode, electrolyte, and separator. The lithium-ion battery is getting the most attention in the ESS. In this paper, we especially want to review a look at technology trends of the cathode and the separator for lithium-ion battery.

  • PDF

Numerical Simulation on the Performance of Axial Vane Type Gas-Liquid Separator with Different Guide Vane Structure

  • Yang, Fan;Liu, Ailan;Guo, Xueyan
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.1
    • /
    • pp.86-98
    • /
    • 2017
  • In order to obtain high efficiency and low resistance droplet separation apparatus, axial vane type gas-liquid separators with different guide vanes were designed, and the RNG $k-{\varepsilon}$ model as well as discrete phase model (DPM) were used to investigate the flow pattern inside the separators. It was shown that the tangential velocity distribution under different guide vanes have Rankine vortex characteristics, pressure distribution exhibits a high similarity which value becomes big as the increase of the blade outlet angle and the decrease of the guide vane numbers. The increase of the guide vane numbers and the decrease of the blade outlet angle could make separation improve significantly. The separation efficiency is almost 100% when the droplet diameter is bigger than $40{\mu}m$.

The Effective Factors of n Foam Generation Using Foam Condensate (포말 농축물에 의한 포말 생성의 영향인자)

  • SUH Kuen-Hack;SHIN Jeong-Sik;LEE Ju-Hwa
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.5
    • /
    • pp.509-514
    • /
    • 2003
  • We performed the experiment to determine the effective factors, such as the initial concentration of protein, pore size of air distributor, SAV (superficial air velocity), pH, salts and temperature related to foaming characteristics. The foam height in a foam generator was increased with the increase of the initial protein concentration and the decrease of pore size. As SAV was increased, the foam height was increased, and the optimum SAV was 0.84 cm/sec. The foam height was highest in the acid region and it was increased with the increase of salt concentration of NaCl and $NaHCO_3.$ The removal efficiencies of TSS (total suspended solid) and turbidity decreased with the increase of the initial protein concentration in the batch foam separator.

Feed Water Flow Control of Super Critical Once Through Boiler in Korea Standard Power Plant (한국표준형 초 임계압 관류형 보일러의 급수제어)

  • 김은기;장용창;조수현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.251-251
    • /
    • 2000
  • Tangjin Power Plant is modern Korean standard plant which is made up Once Through Super Critical Boiler, Turbin, Generator and Flue Gas Desulfarization System. INFI-90 system fur control of the 500 MW Korean standard super critical once through boiler Mark-V for Turbine, EX-2000 fer Generator, WDPF for FGD were installed in Tangiin thermal power plant. There were two BFPTs, BFPM, 25% control valve, 35% control valve to control boiler feed water flow. It is very difficult to tune the Separator Tank level control system and change the mode from Wet to Dry. This paper focuses on test results and modification control logic for feed water control system in Tangjin power plant.

  • PDF

Weld Quality of MCFC Separators With Large Active Area (MCFC용 대면적 분리판의 용접부 품질에 관한 고찰)

  • Kim, K.C.;Jun, J.H.;Kim, S.G.;Kuk, S.T.;Lim, H.C.;Jung, B.S.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.135-138
    • /
    • 2009
  • Quality evaluation of laser welded MCFC separator panels with large active area was performed. Lap joint was applied to produce stable air-tight seam weld by employing Nd:YAG laser. Results showed that surface contamination played a key role to form weld defects at the joint interface. However, there was no evidence that weld width at the lap joint changed after the stack operation time of 2,890h. Test results also revealed that the reinforcement values which were measured on the weld line after long time operation, were stable.

  • PDF

Characteristic of HVOF AISI316-WC Coating Layer on Stainless Steel Separator for PEMFC (고분자 전해질 연료전지용 스테인리스강 분리판의 HVOF AISI316-WC 코팅층 특성)

  • Nam, Dae-Geun;Kang, Nam-Hyun;Park, Yeong-Do;Kim, Young-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1-5
    • /
    • 2008
  • Stainless steels have been widely considered as metallic separators, due to their passive surface film, which is good for corrosion resistance. However, the high resistivity of the passive film increases interfacial contact resistance between the separators and electrodes. Stainless steels thermal spray coated with a mixture of tungsten carbide and stainless steel powders showed that the coated layer safely combined with the matrix but they suffered many internal defects including voids and cracks. Many cracks were formed in the coated layer and the interface of the matrix and the coated layer during the rolling process. The coated and rolled stainless steels showed lower interfacial contact resistance and corrosion resistance than bare stainless steel because of low resistivity of tungsten carbide and numerous defects, which caused crevice corrosion, in the coated layer.

  • PDF

Performance of Dual Polarized MIMO System using Six-Port Receiver for Cognitive Radio

  • Lee Sang-Yub;Yang Wan-Cheol;Lee Jeong-Suk;Kim Hak-Sun
    • Broadcasting and Media Magazine
    • /
    • v.11 no.1
    • /
    • pp.78-85
    • /
    • 2006
  • Cognitive radio is a paradigm for wireless communication in which either network of wireless node itself changes particular transmission or reception parameters to execute its tasks efficiently without interfering with the licensed users. This paper represents a performance of the cognitive radio technology on dual polarized MIMO system using six-port receiver. Six-port technology is well known direct conversion receiver. In this paper, a six-port phase discriminator based polarization signal separation is shown. That is, the SER(Symbol Error Rate) performance is improved using polarization separator and simple receiver architecture is proposed applying six-port receiver. The six-port technology has priority to adapt changeable frequency system and variable environments for cognitive radio. In general, dual polarized MIMO system has good capacity and quality using polarization separator [1].