• Title/Summary/Keyword: separation type

Search Result 1,035, Processing Time 0.025 seconds

An Analysis on Achievement-assessing Style for Serious Game (기능성게임의 성취도 평가 유형 분석)

  • Yoon, Seon-Jeong
    • Journal of Korea Game Society
    • /
    • v.12 no.1
    • /
    • pp.15-24
    • /
    • 2012
  • Serious games are purposive game. So game-developers want to achieve the desired purposes, and game-users also want to play to achieve the goals of playing games. The function of achievement-assessing is an important area of serious game. In this study, achievement-assessing style was defined as three types, that is, 'all-in-one', 'complex', and 'separation'. Accordingly, we analyzed which type of serious games use which type of achievement-assessing style. As a result, the survey shows that those who want to play game itself preferred 'all-in-one' above all, and those who want to stick to the purpose of game preferred 'separation' or 'complex'. In addition, the investigation of preference of achievement-assessing function shows that users, as a whole, preferred 'all-in-one'. We hope this study will be useful data to design of achievement-assessing function which achieve the purpose of game and provide users with higher satisfaction.

Fabrication and Vibration Characterization of a Partially Etched-type Artificial Basilar Membrane

  • Kang, Hanmi;Jung, Youngdo;Kwak, Jun-Hyuk;Song, Kyungjun;Kong, Seong Ho;Hur, Shin
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.373-378
    • /
    • 2015
  • The structure of the human ear is divided into the outer ear, the middle ear, and the inner ear. The inner ear includes the cochlea that plays a very important role in hearing. Recently, the development of an artificial cochlear device for the hearing impaired with cochlear damage has been actively researched. Research has been carried out on the biomimetic piezoelectric thin film ABM (Artificial Basilar Membrane) in particular. In an effort to improve the frequency separation performance of the existing piezoelectric thin film ABM, this paper presents the design, fabrication, and characterization of the production and performance of a partially etched-type ABM material. $O_2$ plasma etching equipment was used to partially etch a piezoelectric thin film ABM to make it more flexible. The mechanical-behavior characterization of the manufactured partially etched-type ABM showed that the overall separation frequency range shifted to a lower frequency range more suitable for audible frequency bandwidths and it displayed an improved frequency separation performance. In addition, the maximum magnitude of the vibration displacement at the first local resonant frequency was enhanced by three times from 38 nm to 112 nm. It is expected that the newly designed, partially etched-type ABM will improve the issue of cross-talk between nearby electrodes and that the manufactured partially etched-type ABM will be utilized for next-generation ABM research.

A Study on the Hidden Type Separation Device for Missile Umbilical Connector (발사 후 은닉형 배꼽연결기 분리장치에 관한 연구)

  • Ahn, Soo-Hong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.598-606
    • /
    • 2013
  • After the missile is launched, the umbilical connector should be separated from it without any physical interference. The umbilical separation device, for this purpose, was developed by means of new concept. Using the investigation of various methods to separate the umbilical connector, a suitable method was selected and a corresponding device was designed and manufactured. To ensure the performance of the developed device, numerical analysis and performance test were conducted and correction was followed. The umbilical separation device was applied to real system operation test and its operation performance was tested. In consequence, several problems were founded, however, good results were generally obtained.

Hydrogen Separation by Compact-type Silica Membrane Process (컴팩트 타입 실리카막 공정을 이용한 수소 분리)

  • Moon, Jong-Ho;Bae, Ji-Han;Lee, Sang-Jin;Chung, Jong-Tae;Lee, Chang-Ha
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.336-339
    • /
    • 2006
  • With the steady depletion off fossil fuel reserves, hydrogen based energy sources become increasingly attractive. Therefore hydrogen production or separation technologies, such as Bas separation membrane based on adsorption technology, have received enormous attention in the industrial and academic fields. In this study, the transport mechanisms of the MTES (methyltriethoxysilane) templating silica/a-alumina composite membrane were evaluated by using unary, binary and quaternary hydrogen gas mixtures permeation experiments at unsteady- and steady-states. Since the permeation flux in the MTES membrane, through the experimental and theoretical study, was affected by molecular sieving effects as well as surface diffusion properties, the kinetic and equilibrium separation should be considered simultaneously in the membrane according to molecular properties. In order to depict the transient multi-component permeation on the templating silica membrane, the GMS (generalized Maxwell-Stefan) and DGM (dust Bas model) were adapted to unsteady-state material balance

  • PDF

A PRACTICAL METHOD FOR THE DISPOSAL OF RADIOACTIVE ORGANIC WASTE

  • Kim, Kil-Jeong;Shon, Jong-Sik;Ryu, Woo-Seog
    • Nuclear Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.731-736
    • /
    • 2007
  • Radioactive organic wastes containing acetone, alcohol, and particularly tributyl phosphate (TBP)/dodecane contaminated with uranium are extracted from the PUREX process and the decontamination of related equipment. An evaporation method that utilizes existing DU oxidation apparatuses and ventilation systems and a typical muffle furnace installed with an aspirating system are adopted. A separation method using phosphoric acid especially for the TBP/dodecane waste is also studied and evaluated. The results show that a simple evaporation process is utilizable for wastes containing acetone or alcohol with a lower boiling point. A modified muffle furnace is more appropriate to dispose directly of organic wastes having a higher boiling point, such as TBP/dodecane, without generating a condensed waste solution. It is recommended that, when the uranium concentration of TBP/dodecane waste is much higher than stipulated levels, separation technology should be applied to remove uranium from the mixture. Each type of solvent after separation can then be considered disposable below the regulatory limit in the modified furnace discussed in this study.

Analysis of Heavy Water Separation Cascade Using Bithermal ${H_2}$/$H_2$O Exchange Process

  • Ahn, Do-Hee;Paek, Seung-Woo;Lee, Han-Soo;Hongsuk Chung;Masami Shimizu
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11b
    • /
    • pp.571-576
    • /
    • 1996
  • The 3-stage cascade composed of the multisection-type bithermal $H_2$/$H_2O$-exchange columns was suggested for heavy water separation. In order to study the separation characteristics for the cascade, a matrix equation with 18 simultaneous equations was composed and the concentrations and flow rates were calculated for the all parts of the cascade. Product D-concentration decreases and extraction yield increases with increasing cut in each stage, which is one of the principal parameters of the separation characteristics. The optimization of the 3-stage cascade can be made by case study using the matrix equation.

  • PDF

The Separation Performance of Disc Plate and Frame Type Reverse Osmosis Modules (원판틀형 역삼투 모듈의 투과성능 비교)

  • 박민수;배성렬;정건용
    • Membrane Journal
    • /
    • v.7 no.2
    • /
    • pp.75-83
    • /
    • 1997
  • The disc plate and frame type modules for reverse osmosis were developed using three different types of baffles: linear (Type 1), curved (Type 2) and parallel shapes (Type 3). Separation performance tests were carried out for the modules using NaCl and sucrose solutions under the various concentrations and operating pressures. The permeation flux and solute rejection ratio for Type 3 module were the highest within operating pressure (35bar) and flow rate (6 l/min). The flux improvement ratio of Type 2 or 3 to Type 1 for NaCl solution decreased as operating pressure increased: flux improvement ratios of Type 3 for 1wt% of NaCl solution were about 100 and 10% at 10 and 35bar, respectively. However, the flux improvement ratio for sucrose solutions varied with the operating pressure and concentration. The permeation flux for Type 3 depended on the flow rate linearly, which is higher than that of turbulent flow region in the smooth channel.

  • PDF

Experimental Study on Flow Characteristic of L-type Groyne (L형 수제주변 흐름특성 변화에 대한 실험연구)

  • Kang, Joon-Gu;Yeo, Hong-Koo;Kim, Sung-Jung
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.7
    • /
    • pp.653-667
    • /
    • 2008
  • The hydraulic model test for the L-type Groynes with "ㄱ" shape were conducted to analyze flow characteristics around these groynes. The results of model tests should be used for the fundamental information to design the L-type Groyne constructed in the field. Main hydraulic factors such as the velocity and thalweg line changes in main channel and separation area were analyzed in this study. The thalweg line is stream line where the maximum velocity occurs, and the separation area is a boundary of main flow and recirculation zone. Model tests with 5 different arm-lengths of the L-type Groynes were conducted changing the velocity. The LSPIV(Large Scale Particle Image Velocimetry) technique was used to measure and analyze the flow variation around the L-type Groynes. The velocity in main channel was increased 1.5 times and there was no effects of different groyne arm-length on the velocity changes. The width of thalweg lines $(T_{CL})$ was changed to $55{\sim}58%$ of chanel width, and the Froude number did not affect on the thalweg line $(T_{CL})$ and separation line $(S_h)$ changes.

Evaluation of Separation Distance from the Temporary Storage Facility for Decontamination Waste to Ensure Public Radiological Safety after Fukushima Nuclear Power Plant Accident (후쿠시마 원전 사고 이후 일반인의 방사선학적 안전성 확보를 위한 제염폐기물 임시저장시설 이격거리 평가)

  • Kim, Min Jun;Go, A Ra;Kim, Kwang Pyo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.3
    • /
    • pp.201-209
    • /
    • 2016
  • The object of this study was to evaluate the separation distance from a temporary storage facility satisfying the dose criteria. The calculation of ambient dose rates took into account cover soil thickness, facility size, and facility type by using MCNPX code. Shielding effects of cover soil were 68.9%, 96.9% and 99.7% at 10 cm, 30 cm and 50 cm respectively. The on-ground type of storage facility had the highest ambient dose rate, followed by the semi-ground type and the underground type. The ambient dose rate did not vary with facility size (except $5{\times}5{\times}2m\;size$) due to the self-shielding of decontamination waste in temporary storage. The separation distances without cover soil for a $50{\times}50{\times}2m\;size$ facility were evaluated as 14 m (minimum radioactivity concentration), 33 m (most probably radioactivity concentration), and 57 m (maximum radioactivity concentration) for on-ground storage type, 9 m, 24 m, and 45 m for semi-underground storage type, and 6 m, 16 m, and 31 m for underground storage type.

A Study on Material Separation of Waste Plastics Beer Bottle by Triboelectrostatic Separation (마찰하전형(摩擦荷電型) 정전선별(靜電選別)에 의한 폐플라스틱 맥주병 재질분리(材質分離)에 관한 연구(硏究))

  • Jeon, Ho-Seok;Delgermaa, Delgermaa;Baek, Sang-Ho;Park, Chul-Hyun;Choi, Woo-Zin
    • Resources Recycling
    • /
    • v.17 no.1
    • /
    • pp.43-50
    • /
    • 2008
  • In this study, we carried out the research on triboelectrostatic separation for materials separation of PET & Nylon recovered to waste plastic beer bottle. From the research on charging characteristic for choice of charging materials, it was found that PMMA was optimum charging material to make high charging amount with opposite polarity for PET & Nylon in waste plastic beer bottle. Therefore, we manufactured a charger of pipe line and cyclone type using PMMA material for separation of PET and Nylon. At optimum test conditions that used PMMA pipe line and cyclone charger developed in this study, we developed a triboelectrostatic separation technique that can separate PET plastic up to grade of 99.6% and recovery of 88.2%. We established new separation technology that can recycle the PET and Nylon recovered from waste plastic beer bottle.