• 제목/요약/키워드: separation ratio

검색결과 1,111건 처리시간 0.027초

종축 실린더의 항력에 대한 수치 해석적 연구 (A Numerical Study on the Drag of Axial Cylinder)

  • 이현배;최정규;김형태
    • 대한조선학회논문집
    • /
    • 제49권6호
    • /
    • pp.512-520
    • /
    • 2012
  • In this study, the numerical analysis for the flows around an axial cylinder is carried out in order to investigate the basic characteristics of drag of blunt body. A variation of drag and flow separation for the axial cylinder is investigated according to the length-diameter ratio. Also, the flow separation around the head is removed by rounding-off the front edge of the body to analyze the effect of drag reduction. Most of the drag turns out to be a pressure drag component and the variation of drag is caused by the change of pressure and velocity which is affected strongly by the flow separation at the edges of the axial cylinder. Especially, it is found that the pressure drag component acting on the back of axial cylinder, as known as the base drag, mainly changes the drag. As the length-diameter ratio of axial cylinder increases, the drag sharply decreases and the minimum is shown when the length-diameter ratio is about 2.4. Also, as the length-diameter ratio increases further above 2.4, the drag increases at a slower rate. The pressure drag is almost constant when the length-diameter ratio is greater than 8, but the increase of friction drag component is the reason for the increase of the drag. When flow separation is removed completely at the front edge of the axial cylinder, the pressure drag component is reduced to 12~17%, but the total drag is reduced to only 17%~32% due to the friction drag component that increases linearly proportional to the length-diameter ratio.

공기공급 시스템에 적용되는 Vortex Tube의 에너지 분리특성에 관한 연구(I) -저온출구 orifice의 직경변화에 의한 영향- (A Study for Energy Separation of Vortex Tube using Air Supply System (I) - the effect of diameter of cold end orifice -)

  • 이병화;추홍록;상희선
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.9-18
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air supply system. The phenomena of energy separation through the vortex tube was investigated experimentally. This study is focused on the effect of the diameter of cold end orifice diameter on the energy separation. The experiment was carried out with various cold end orifice diameter ratio from 0.22 to 0.78 for different input pressure and cold air flow ratio. The experimental results were indicated that there are an optimum diameter of cold end orifice for the best cooling performance. The maximum cold air temperature difference was appeared when the diameter ratio of the cold end orifice was 0.5. The maximum cooling capacity was obtained when the diameter ratio of the cold end orifice was 0.6 and cold air flow ratio was 0.7.

  • PDF

의약분업 전.후 병원재무구조 평가 (Analysis of Financial Structure of Hospitals Before and After The Separation of Prescription and Drug Dispensing Policy)

  • 박호순;류규수;이창은
    • 한국병원경영학회지
    • /
    • 제8권3호
    • /
    • pp.118-142
    • /
    • 2003
  • This study is aimed at evaluating the financial structure of hospitals before and after the separation of prescription and drug dispensing policy started to be implemented in July 2000 and at making a suitable hospital managerial strategy through the verification of the factors which have effect on their profitability. This study investigated the hospitals which have passed the accredition review to be designated as a accredited training hospital each year for three years from 1999 to 2001. Those hospitals were selected from members of the Korea Hospital Association. 106 hospitals were targeted for analysis except for the hospitals whose financial statements and managerial performance were not reported faithfully. The financial indicators used in this study were stability indicators(liability to total assets, ratio of debt to fund balance, fixed ratio), liquidity indicators(current ratio, quick ratio), activity indicators(total assets turnover, fixed assets turnover), profitability indicators(net profit to total assets, net profit to net worth, operating margin), and operating expenses to patient revenues indicators(drug and supplies costs/payroll/overhead expenses). The result of this study are as follows: First, the analysis of the increase of loss-making hospitals before and after. The separation of prescription and drug dispensing policy shows that the number of loss-making hospitals increase after the separation(22.6% before the separation; 31.1% after the separation). However, there was no significant statistical difference. Second, the analysis of operating expenses to patient revenues indicators showed that the ratio of drug and supplies cost became lower in all hospitals but the ratio of payroll/overhead expenses became higher. Additionally, the factor which have the greatest effect on profitability was operating expenses to patient revenues indicators (drug and supplies costs/payroll/overhead expenses). Third, the analysis of managerial performance by four types of loss-loss, loss-profit, profit-loss and profit-profit compared the results before the separation with those after the separation revealed as follows : Reliance on liability to total assets became higher in the profit-loss type($56.2%{\rightarrow}66.4%$), lower in the loss-profit type($82.7%{\rightarrow}74.5%$). Total assets turnover became higher in the profit-profit type($1.3{\rightarrow}1.5$), but lower in the loss-profit type($0.8{\rightarrow}0.7$). Operating margin decreased to minus 5.9% from 4.3% in the profit-loss type, but increased to 7.2% from minus 7.8% in the loss-profit type. Forth, operating expenses to revenues indicators showed that the increase of payroll was the biggest in the profit-loss type($39.2%{\rightarrow}49.9%$) and that overhead cost decreased in the loss-profit type but that rather increased in other types.

  • PDF

합류부 하상고 불일치에 의한 분리구역 특성분석 (An Analysis on the Characteristics of Separation Zone Due to a Bed Discordance at Confluence)

  • 최흥식;모선재
    • 한국수자원학회논문집
    • /
    • 제48권8호
    • /
    • pp.625-634
    • /
    • 2015
  • 합류부에서의 지류의 합류각, 지류와 본류의 유량비에 추가하여, 본류 준설에 의한 하상고 불일치에 따른 다양한 양상의 분리구역의 특성을 CCHE2D 모형을 사용하여 분석하였다. 분리구역은 지류가 합류되어진 직후 단면에서의 유속이 0(영)인 경계로 정의하였다. 합류각 $30^{\circ}$ 이하에서는 분리구역이 형성되지 않았다. 유량비와 합류각 증가에 따른 분리구역의 크기는 일반적으로 증가하는 양상으로 나타났다. 준설 깊이비 증가에 따른 분리구역의 크기는 합류부 수용체의 증가에 기인한 지류에서의 상대적인 운동량의 감소로 인하여 감소되었다. 유량비와 합류각의 변화에 따른 분리구역의 수축지수를 규명하였고, 통수기능의 저하에 따른 배수영향을 확인하였다. 합류각, 유량비, 준설 깊이비에 따른 분리구역의 형상지수의 관계식을 제안하였다.

의약분업이후 대학병원 경영수지변화 비교 분석 (D지역 대학병원 사례를 중심으로) (An Analysis of the Changes in the Financial Performance of Teaching Hospitals after the Implementation of the Separation Policy of Prescription and Drug Dispensing: A case of the teaching hospitals in D area)

  • 은종성;윤경일
    • 한국병원경영학회지
    • /
    • 제8권1호
    • /
    • pp.64-80
    • /
    • 2003
  • The separation policy of prescription and drug dispensing which has been implemented since the 1st of July, 2000, has brought about great changes in patients flow within the healthcare delivery system. The changes in the patients flow, in turn, resulted in the change in the distribution of financial resources among the participating entities in the healthcare delivery system: pharmacies, clinics, small hospitals, general hospitals, and teaching hospitals. The purpose of this study is to shed some light in the change in the financial performance of teaching hospitals under the separation policy that has created environmental changes such as the decrease in the number of out patients visits, the increase in the capital expenditures, the rapid increase in labor costs and so on. For the purpose, this study has compared and analyzed the balance sheets, the income statements and other operational data of three teaching hospitals located in D area. The data include two periods: before(year 1999) and after(year 2001) the implementation of the separation policy. The analysis was conducted with an emphasis on the changes in the financial ratios such as liquidity, turnover ratio, performance ratio. and capitalization ratio. The results show that the financial performances of the hospitals under study were weaker than before the implementation of the separation policy, and that, while the operating expenses have increased remarkably, there was no tendency to corresponding increase in revenue. And the result of analysis of other operational indicators also show that the performance of the hospitals is getting worse. Based on the results, this study has suggested the directions of the healthcare policies. This study suggests to improve the current model of separation of prescription and drug dispensing, to grant subsidies for the training of residents in teaching hospitals, and to lower the rate of patients' out of porket payment in teaching hospitals.

  • PDF

CASA 기반 음성분리 성능 향상을 위한 형태 분석 기술의 응용 (Application of Shape Analysis Techniques for Improved CASA-Based Speech Separation)

  • 이윤경;권오욱
    • 대한음성학회지:말소리
    • /
    • 제65호
    • /
    • pp.153-168
    • /
    • 2008
  • We propose a new method to apply shape analysis techniques to a computational auditory scene analysis (CASA)-based speech separation system. The conventional CASA-based speech separation system extracts speech signals from a mixture of speech and noise signals. In the proposed method, we complement the missing speech signals by applying the shape analysis techniques such as labelling and distance function. In the speech separation experiment, the proposed method improves signal-to-noise ratio by 6.6 dB. When the proposed method is used as a front-end of speech recognizers, it improves recognition accuracy by 22% for the speech-shaped stationary noise condition and 7.2% for the two-talker noise condition at the target-to-masker ratio than or equal to -3 dB.

  • PDF

PERMEATION OF CARBON DIOXIDE AND NITROGEN GASES THROUGH POLY(AMIDE-IMIDE)/POLYURETHANE AND POLYCARBONATE/POLYURETHANE BLEND MEMBRANES

  • Kim, Min-Joung;Sea, Bong-Kuk;Park, You-In;Youm, Kyung-Ho;Lee, Kew-Ho
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2003년도 The 4th Korea-Italy Workshop
    • /
    • pp.87-89
    • /
    • 2003
  • Thermoplastic polyurethane(PU)-based blend membranes were prepared by the solvent evaporation process. The gas sorption, diffusion, and permeation properties of PU-based blend membranes have been studied. The morphology of PU-based blend membranes was investigated by SEM. The result showed that phase separation occurred with increasing blend ratio. $CO_2$ permeation behaviors of blend membranes were affect by blend composition. Thermoplastic polyurethane(PU)-based membranes showed high $CO_2$ permeation and $CO_2$/$N_2$ selectivity of the blend membrane was improved with increasing the blend ratio.

  • PDF

횡유입에 의한 합류부 홍수특성 분석 (Analysis of Flood Characteristics at Confluence by Lateral Inflow)

  • 최흥식;조민석;박용섭
    • 한국방재학회 논문집
    • /
    • 제6권1호
    • /
    • pp.59-68
    • /
    • 2006
  • 합류부는 유량의 변화, 흐름방향의 전환으로 순환흐름의 분리구역의 발생에 의한 통수단면의 축소에 의한 통수능의 저하와 이에 따른 배수의 영향이 야기된다. 지류와 본류와의 유량비와 합류각을 달리하면서 실험한 결과를 이용하여 분리구역의 특성을 규명하였다. 분리구역의 정의는 유함수를 이용하여 그 값이 0(영)인 유선을 분리구역으로 정의하여 그 길이와 폭을 본류 하천폭으로 나눈 무차원 길이비와 무차원 폭비로 하였고, 유선에 의한 분리구역의 연구결과가 기존의 실험들과 비교적 잘 맞는 것으로 나타났다. 작은 유량비와 합류각 30도에서는 분리구역이 나타나지 않아서 유량비와 합류각에 의한 분리구역의 출현경계식을 만들었다. 분리구역에 대한 고찰로 합류각, 유량비, 그리고 본류 하류에서의 Froude수에 의한 분리구역의 무차원 길이비와 폭비에 대한 기존의 실험식을 수정하였고, 수굴계수와 형상지수의 수리적 특성을 분석하였다. 일반적으로 유량비와 합류각이 커질수록 분리구역이 크게 나타났다. 합류부를 전후한 상하류 구간에서 수면의 추적에서 유량비와 합류각이 커질수록 배수위의 영향이 크게 나타났고, 합류부가 접하는 내측보다 외측의 배수영향이 크게 나타났다. 하류부 유량에 의해 등류수심을 산정하여 합류가 시작되는 점에서부터 하류의 등류수심에 이르는 곳까지의 거리를 $X_l$로 보고 합류각과 유량비와 단면폭 및 수축계수간의 상관관계식을 산출하였다. 유량비와 합류각에 따른 수로내의 배수위에 의한 최대수위와 분리구역에서의 최소수심과의 비를 분석하였다.

2차원 직사각형 덕트 내부에 돌기부를 갖는 흐름의 동결특성에 관한 연구 (Freezing Characteristics in a Horizontal Rectangular Channel with the Two-Dimensional Protuberances)

  • 오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권6호
    • /
    • pp.721-727
    • /
    • 2003
  • Freezing of turbulent water flow between two horizontal cooled parallel plates with the separated region has been investigated experimentally. The flow separation was induced by vertical plates (two-dimensional plates) situated at the inlet of the rectangular channel. The degree of flow separation was varied by employing vertical thin plates with various heights. Three kinds of the vertical plates with 8.0, 9.8 and 12.5 mm in height were utilized. The Reynolds number and cooling temperature ratio were ranged from $3.45\times10^3 to 1.73\times10^4$ and 7.0 to 20.0 respectively, The measurements show that the flow separation influenced remarkably on the local ice formation characteristics. The location of the first ice layer and the average heat transfer at the ice surface were found be correlated as a function of the Reynolds number, the cooling temperature ratio, and the orifice height ratio.

Performance Analysis of a Hydrodynamic Separator for Treating Particulate Pollutants in Highway Rainfall Runoff

  • Yu, Jianghua;Yi, Qitao;Kim, Young-Chul
    • Environmental Engineering Research
    • /
    • 제14권4호
    • /
    • pp.262-269
    • /
    • 2009
  • This study examined the separation characteristics of particles in the rainfall runoff from paved roads using a ${\varphi}7.5$ cm hydrocyclone. The volume fraction and total suspended solids concentrations in the overflow and underflow from the hydrocyclone, as well as the separation efficiency were determined. The results indicated that the overflow volume increased with increasing operational pressure, but decreased with decreasing ratio of underflow outlet to inlet sizes ($D_u/D_i$), while the underflow to overflow volumes showed contrary behavior. The total suspended solid (TSS) concentration ratio between the overflow and inflow ($TSS_{over/in}$) decreased as a function of the operational pressure, while the corresponding ratio of underflow to inflow ($TSS_{under/in}$) increased. There was no visible difference in the $TSS_{over/in}$ with increasing $D_u/D_i$ ratio, but the $TSS_{under/in}$ decreased sharply. The particle removal efficiency was mainly affected by the particle size.