• Title/Summary/Keyword: separation method of precipitation

Search Result 72, Processing Time 0.027 seconds

A review on Separation Technologies for Lithium Recovery from Waste Solutions in Recycling Process of Waste Battery (폐배터리 재활용 공정 폐액 중 리튬 회수를 위한 분리 기술 고찰)

  • Song, Daesung;Kim, Eunkyu;Vu, Thang-Toan
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.473-477
    • /
    • 2022
  • In this study, candidate technologies for lithium recovery from the process waste liquid generated in the waste battery recycling process were reviewed, and technologies applicable to the process from the commercialization point of view were reviewed from a qualitative point of view. The evaporation method is difficult to apply because it requires a large-scale land and shows a low recovery rate due to the loss of Li during the concentration process. In the case of precipitation, a commercially available technology shows a high recovery rate due to the high Li/Na selectivity of phosphoric acid, but there are disadvantages in that the process is complicated due to the use of expensive phosphoric acid, requiring a recovery step, and continuous operation is impossible because solids are handled in the Li concentration process. In the case of solvent extraction, if we find an inexpensive extractant with high Li/Na selectivity, continuous operation is possible with the method used in extraction of other metals in the previous step, and when Li is concentrated, continuous operation is possible because it is in a liquid state. If it shows a similar recovery rate compared to precipitation technology, commercialization will be the most likely.

Studies on Separation and Determination of Korean Bovine Serum Protein by Colorimetric Method (비색법에 의한 한우 혈청단백질의 분획정량 시험)

  • Cho, J.H.
    • Korean Journal of Veterinary Research
    • /
    • v.11 no.2
    • /
    • pp.145-148
    • /
    • 1971
  • Serum Samples from adult of Korean cattles including 40 females and 20 males were analyzed by sodium salt precipitation and colorimetric method in the purpose of the determination of total serum protein, albumin, globulin, ${\alpha}$-globulin, ${\beta}$-globulin and ${\gamma}$-globulin. The results obtained arc summarized as follows: 1. Mean value of total serum protein showed a slight variation from 7.6%, and its regional and sex differences were not found to be significant. 2. Contents of albumin in serum showed lower level than that of globulin as low level of A/G ratio 0.4 in proportion. 3. Contents of Serum ${\alpha}$-globulin showed 1.4w/v% and $1.51{\pm}0.46$w/v% in each group of female, and $1.31{\pm}0.26$w/v%, in the group of male. 4. Contents of serum ${\beta}$-globulin showed 1.74w/v%, 1.95w/v%, in each group of female, and 1.82w/v% in the group of male. 5. Contents of serum ${\gamma}$-globulin showed 2.32w/v%, 2.30w/v% in each group of female, and 2.30w/v%, in the group of male.

  • PDF

Experimental study on treatment of waste slurry by vacuum preloading with different conditioning agents

  • Wu, Yajun;Jiang, Haibo;Lu, Yitian;Sun, Dean
    • Geomechanics and Engineering
    • /
    • v.17 no.6
    • /
    • pp.543-551
    • /
    • 2019
  • In China, serious environmental problems are induced by the extremely soft construction waste slurries in many urban areas, and there is no appropriate method to treat it presently. In this paper, four model tests were conducted to investigate the efficiency of waste slurry treatment by combining three conditioning agents which can change characteristics of the slurries with a traditional vacuum preloading method. The tests of size analysis of particle aggregate were conducted to investigate the influence of different conditioning agents on the size distributions of particle aggregate. During the model test, the discharged water volumes were monitored. The pore-size distribution and void ratio of the waste slurries after the vacuum preloading were measured by mercury intrusion porosimetry (MIP). It is found that 1) During the natural precipitation, volume of water out of the organic agent is higher than that of the mixed agent, but it is smaller than that of the mixed agent in the vacuum preloading stage; 2) the mixed agent has a higher total volume of water out than the organic agent and the inorganic agent after test, while the organic agent and the inorganic agent have little difference with respect to the drainage effect. The results demonstrate that the combination of mixed conditioning agent and vacuum preloading for the solid-liquid separation in waste slurry has a satisfactory effect and can be applied in engineering practice.

A Fast Determination of Globotriaosylsphingosine in Plasma for Screening Fabry Disease Using UPLC-ESI-MS/MS

  • Yoon, Hye-Ran
    • Mass Spectrometry Letters
    • /
    • v.6 no.4
    • /
    • pp.116-119
    • /
    • 2015
  • Globotriaosylsphingosine (lyso-Gb3) is considered as one of the biological marker for Fabry disease. To date, a reliable biomarker that reflects disease severity and progression has not been discovered to guide the management of Fabry disease. A new method included a simple protein precipitation with acetonitrile in 100 μL of plasma following analyte separation on an Phenomenex Kintex- C18 column using a gradient elution (0.1% formic acid in 5-90% acetonitrile). Total run time was within 12 min including sample preparation and MS/MS analysis. The limit of detection and limit of quantitation were 1 ng/mL and 2 ng/mL, respectively. The calibration curve was linear over the concentration range of 2.0-200.0 ng/mL (r2 = 0.9999). Inter-day accuracy and precision at 7 level were 93.4-100.7% with RSD of 0.55-5.97%. Absolute recovery was 97.6-98.6%. The method was applied to human and mice plasma, proved the suitability for quantification of lyso-Gb3 for screening, diagnosis and therapeutic monitoring of Fabry disease patients.

A study on the color controlled of painter's work (페인트 도장공사의 색관리에 관한 연구)

  • Shim, Myung-Sup;Lee, Hyun-Jeong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.1
    • /
    • pp.107-114
    • /
    • 2003
  • This study aims to find methods that prevents aging of buildings paint coating and that limits defects in construction. Defects in painting can occur in four stages: pure paint, during painting, after the paint coating has dried, and after some period of time has passed after coating. Paint may become bad due to precipitation of pigments, formation of membranes, and seeding during manufacturing. Therefore, it is important that the paint is well mixed and kept airtight at a cool, dark place. Indents, paint brush strokes, orange peel, separation of colors, and paint running and spreading during the paint work process can be prevented by using high quality materials and applying a high-level of construction method. After the paint coating has dried, boiling, yellowing, poor drying, poor bonding, and/or glen deficiency may occur. These are influenced by the levels of cleanness of the dried product, drying temperature and hydration. Then, when the coating has been left dried for some period of time, cracking, peeling, scaling, swelling, discoloring, and/or rusting may develop due to the ultraviolet and contaminants in the air. Since these defects occur due to inappropriate construction schedule and/or hot and humid condition, one must use weatherproof materials. Furthermore, poor paint color may be caused by contamination in the sample plate, discoloration, and/or discrepancies in colors which are due to material differences, level of glossiness, degree of dispersion, dual color property of metallic colors, precipitation of pigments, etc. One should achieve reduction in construction cost and effectiveness in paint work by limiting contaminations in the construction site and strictly observing to construction regulations.

A Study on the Compatibility of Polycarbonate/Polyamide 6 Blends (Polycarbonate/Polyamide 6 블랜드의 상용성에 관한 연구)

  • Park, Tae-Wook;Lee, Chi-Giu;Haw, Jung-Rim
    • Applied Chemistry for Engineering
    • /
    • v.4 no.3
    • /
    • pp.601-615
    • /
    • 1993
  • A series of polycarbonate(PC)/polyamide 6(PA6) blends were prepared by three different blending methods to investigate their compatibility. From the DSC results, all of these blends have two Tg's in their own Tg regions, and there was no significant depression of the melting point and the crystallization temperature of PA6. With respect to the microstructure of the blends by SEM, the phase separation occurred at very low blend compositions, PC/PA6=95/5 and 5/95, already. In addition, a method is proposed to determine the Flory-Huggins polymer-polymer interaction parameter(${\chi}_{12}$) in polymer blend systems by using the experimentally determined Tg's. The values of ${\chi}_{12}$ obtained were 0.0381, 0.0411, 0.0418, for solution casting, solution precipitation, and extrusion blending methods, respectively. These values were higher than the critical value of ${\chi}_{12}$,($({\chi}_{12})_c$, 0.0271). Therefore it was concluded that the PC/PA6 blend system have little compatibility.

  • PDF

Synthesis of Cd1-xZnxS/K4Nb6O17 Composite and its Photocatalytic Activity for Hydrogen Production

  • Liang, Yinghua;Shao, Meiyi;Liu, Li;Hu, Jinshan;Cui, Wenquan
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.4
    • /
    • pp.1182-1190
    • /
    • 2014
  • $Cd_{1-x}Zn_xS$-sensitized $K_4Nb_6O_{17}$ composite photocatalysts (designated $Cd_{1-x}Zn_xS/K_4Nb_6O_{17}$) were prepared via a simple deposition-precipitation method. The samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive X-ray spectrometry (EDS), $N_2$ sorption, ultraviolet-visible light diffuse reflectance spectroscopy (UV-Vis DRS), photoluminescence measurements (PL), and X-ray photoelectron spectroscopy (XPS). The $Cd_{0.8}Zn_{0.2}S$ particles were scattered on the surface of $K_4Nb_6O_{17}$, and had a relatively uniform size distribution around 50 nm. The absorption edge of $K_4Nb_6O_{17}$ was shifted to the visible light region and the recombination of photo-generated electrons and holes suppressed after $Cd_{0.8}Zn_{0.2}S$ loading. The $Cd_{0.8}Zn_{0.2}S$(25 wt %)/$K_4Nb_6O_{17}$ composite possessed the highest photocatalytic activity for hydrogen production under visible light irradiation, evolving 8.278 mmol/g in 3 h. Recyclability tests were performed, and the composite photocatalysts were found to be fairly stable. The mechanism of charge separation between the photogenerated electrons and holes at the $Cd_{0.8}Zn_{0.2}S/K_4Nb_6O_{17}$ composite was discussed.

Pentafluorophenylprophyl Ligand-based Liquid Chromatography-Tandem Mass Spectrometric Method for Rapid and Reproducible Determination of Metformin in Human Plasma

  • Yang, Jeong Soo;Oh, Hyeon Ju;Jung, Jin Ah;Kim, Jung-Ryul;Kim, Tae-Eun;Ko, Jae-Wook;Lee, Soo-Youn;Huh, Wooseong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3284-3288
    • /
    • 2013
  • This paper describes first development and validation of pentafluorophenylprophyl ligand-based liquid chromatography coupled to tandem mass spectrometry (PFPLC-MS/MS) method to determine metformin, a highly polar compound, in human plasma. Metformin and Phenformin (internal standard) were extracted from human plasma 50 ${\mu}L$ with a single-step protein precipitation. The chromatographic separation was performed using a linear gradient elution of mobile phase involving 5.0 mM ammonium formate solution with 0.1% formic acid (A) and acetonitrile (B) over 3.0 min of run time on a Phenomenex Luna PFP column. The detection was performed using a triple-quadrupole tandem mass spectrometer (Waters Quattro micro) with electrospray ionization in the mode of positive ionization and multiple-reaction monitoring (MRM). The developed method was validated with 5.0 ng/mL of lower limit of quantification (LLOQ). The calibration curve was linear over 5-3000 ng/mL of the concentration range ($R^2$ > 0.99). The specificity, selectivity, carry-over effect, precision, accuracy and stability of the method met the acceptance criteria. The method developed in this study had had rapidness, simplicity and ruggedness. The reliable method was successfully applied to high throughput analysis of real samples for a practical purpose of a pharmacokinetic study.

Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study

  • Yang, Jeong Soo;Cho, Eun Gi;Huh, Wooseong;Ko, Jae-Wook;Jung, Jin Ah;Lee, Soo-Youn
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2425-2430
    • /
    • 2013
  • A simple, fast and robust analytical method was developed to determine imatinib in human plasma using liquid chromatography-tandem mass spectrometry with electrospray ionization in the positive ion mode. Imatinib and labeled internal standard were extracted from plasma with a simple protein precipitation. The chromatographic separation was performed using an isocratic elution of mobile phase involving 5.0 mM ammonium formate in water-5.0 mM ammonium formate in methanol (30:70, v/v) over 3.0 min on reversed-stationary phase. The detection was performed using a triple-quadrupole tandem mass spectrometer in multiple-reaction monitoring mode. The developed method was validated with lower limit of quantification of 10 ng/mL. The calibration curve was linear over 10-2000 ng/mL ($R^2$ > 0.99). The method validation parameters met the acceptance criteria. The spiked samples and standard solutions were stable under conditions for storage and handling. The reliable method was successfully applied to real sample analyses and thus a pharmacokinetic study in 27 healthy Korean male volunteers.

Imporoved Method for the Preparation of Silk Fibroin Hyoysates

  • Shukhrat Madyarov;Lee, kawng-Gill;Yeo, Joo-Hong;Jin Nam;Lee, Yong-Woo
    • Journal of Sericultural and Entomological Science
    • /
    • v.41 no.2
    • /
    • pp.108-115
    • /
    • 1999
  • An improvement of methods in fibroin hydrolysates preparat significantly enlarges their applications to practical use. Acidic hydrolysis by hydrohloric acid is one of the methods for silk fibroin depolymeriza6tion. A low yield of final product and long time of the process are the demerits of this method. Possibility of preparation of water-soluble silk hydrolysates with more yield and less expenses is investigated in this study. Such possibility is occurred with the increasing tratment temperature and simultaneously decreasing treatment time, concentration of hydrochoric acid respectively, the concentration of sodium hydroxide used for neutraliza6tion of hydolysates after hydrolysis. Colour is decreased in this case and a small amount of activated, too. Protection of hydrolysates against precipitation after neutraliza6tion, and separation and during concentrating process is the other merit of this method. Creamy-coloured insoluble silk powder is the remainder of hydrolyzed fibroin. This is the only the immobiliza6tion of enzymes and other physiological active substances. Fine particles of this powder can be used as additives for artificial diets and cultural media, as well as raw materials for polymer membranes, etc.

  • PDF