• Title/Summary/Keyword: separation efficiency

Search Result 1,116, Processing Time 0.028 seconds

Models for Measurement of Efficiency of Free Flight Separation Assurance (자유비행 분리보증 효율성 측정모델 연구)

  • Lee, Dae-Yong;Young, Kang-Ja
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.6
    • /
    • pp.977-985
    • /
    • 2011
  • Airborne separation assurance is a key requirement for Free Flight Airspace operations, This paper study the feasibility of airborne separation assurance for free flight Airspaces operations by evaluating the efficiency measurement models. Three qualitatively different methods are utilized; one based Ground and Air conflict probability model, other based Dynamic Density model. the other based Direct operating cost model. The evaluation is Direct Operating Cost model and Two metrics are utilized for the efficiency measurements; airborne separation assurance performed quite well in the Free Flight evaluation; (1) 2 scenario of the conflict situations are resolved; (2) The MD-80 flight peformed separation assurance and efficiency, Not only appling for geometric method algorithm is more efficiently than potential method, but also the most efficiently geometric combined method.

Particle Separation Characteristics and Harvesting Efficiency of Spirulina platensis Using Micro-bubble (미세기포를 이용한 Spirulina platensis의 입자 부상분리 특성 및 수거효율)

  • Gwak, Gyu-Dong;Kim, Mi-Sug;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.621-629
    • /
    • 2013
  • Since algae had been issued an environmental problem, water blooms, deepened due to increase of retention water basin in Korea as well as a biomass resource for producing biofuel, this study conducted a series of experiments for Spirulina platensis using the flotation process with micro-bubble. To elevate utilization of collected-algae, this study focused on omitting or minimizing coagulant's doses as changing a cultivation period and condition affected on physical property change of algae. Two coagulants, PAC and Chitosan, were used to test the collecting rate of algae and the result found no difference between two rates. For flotation experiments without adding the coagulant, dried algae weight (passing 14 days after cultivation for 20 days) detected high separation efficiency 98.2 % and it (passing 7 days after long-term cultivation for 28 days) presented good separation efficiency 91.9 %. Chlorophyll's separation efficiency showed a similar tendency with the case of the dried algae weight. In endogeny conditions, a light source and a carbon source were not considerably affected on the flotation separation efficiency. Thus, this study confirms that algae biomass may be collected without the coagulant during the endogeny condition period after enough cultivation time, 3 weeks.

Continuous Microalgae Separation Process Using Ultrasonic Waves (초음파를 이용한 미세조류 연속분리공정)

  • Kim, Sung Bok;Jeong, Sang Hwa
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.4
    • /
    • pp.407-413
    • /
    • 2015
  • Research for renewable energy is being performed since it has the merits of little pollution of the environment and sustainable energy resources. Microalgae is attractive as a renewable energy resource. Biomass of the microalgae can be produced by mass culturing, and bulk harvest technology of is needed to produce biomass continuously. Recently, ultrasonic waves were used to harvest the cultivated microalgae continuously. In this study, the separation process using ultrasonic waves was performed to effectively harvest the microalgae. An ultrasonic wave separation resonator was designed and manufactured based on the acoustic field analysis. Separation experiments using design of experiment were carried out, and the influence of experimental variables from the ultrasonic wave separation process was investigated. Mixing conditions of variables were estimated to obtain high separation efficiency and a large microalgae harvest. Experimental results for suitable mixing conditions were compared with simulation results calculated from the state equation.

Utilization of functionalized magnetic nanoparticles for high throughput DNA separation

  • Jang, Jeong-Ho
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.12.2-12.2
    • /
    • 2009
  • The work describes anoptimized process to highly efficient and convenient preparation in highthroughput magnetic human DNA separation with chemically functionalizedsilica-coated magnetic nanoparticles. The effect of nanoparticle's size and the surface's hydrophilicity change were studied for magnetic DNA separation process, inwhich the optimum efficiency was explored via the function of the amino-groupnumbers, particle size, the amount of the nanoparticles used, and theconcentration of NaCl salt. The DNA adsorption yields were high in terms of theamount of triamino-functionalized nanoparticles used, and the average particlesize was 25 nm. The adsorption efficiency of aminofunctionalized nanoparticleswas the 4-5 times (80-100%) higher compared to silica-coated nanoparticles only(10-20%). DNA desorption efficiency showed an optimum level of over 0.7 M ofthe NaCl concentration. To elucidate the agglomeration of nanoparticles afterelectrostatic interaction, the Guinier plots were calculated from small angleX-ray diffractions in a comparison of the results of electron diffraction TEM,and confocal laser scanning microscopy. Additionally, the direct separation ofhuman genomic DNA was achieved from human saliva and whole blood with highefficiency.

  • PDF

Separation of Cd(II) from Aqueous Solutions by A New Consecutive Process Consisting of Supported Liquid Membrane and Electrodialysis

  • Altin, Sureyya;Altin, Ahmet
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.14-21
    • /
    • 2019
  • Supported liquid membrane process usually is used for recovering or enrichment of valuable metals in the industrial wastewater. But, even if the metals in the wastewater was separated with high chemical selectivity, it cannot be enough concentrated since separation performance of supported liquid membrane (SLM) process is limited by concentration gradient between feed solution and stripping solution. If metal concentration in the stripping solution to be enough low, transport of metal through membrane can be accomplishment constantly. Therefore, Electrodialysis (ED) has been placed after SLM process and the stripping solution of SLM was used as the feed solution for the ED process. Transport of ions in the solutions is successfully performed by ED process. Thus, the metal concentration in the stripping solution does not rise as to stop ion transport. Besides, valuable metals easily are concentrated by ED process for re-use. In this study, effects of operation parameters like initial Cd(II) concentration, HCl concentration in the feed solution of SLM and applied voltage are investigated on separation efficiency, flux and permeability of the both processes. As the feed solution concentration increased, all performance values has increased. When initial concentration of 100 mg/L is used, separation performances (SP) are 55% and 70%, for SLM and consecutive process, respectively. The best HCl concentration in the feed solution of SLM has determined as 2 M, in this conditions SP are 64% and 72%, for SLM and consecutive process, respectively. With increased of applied voltage on ED process, SP of the consecutive process has been raised from 72% to 83%. According to the obtained experimental data, consecutive process has better separation performance than SLM. When the separation performances of both processes were compared for the same operating conditions, it was determined higher the separation efficiency, permeability and flux values of the consecutive process, 8%, 9% and %10.6, respectively. Consequently, the use of the consecutive process increases the performance efficiency of both processes. The consecutive process studied has quite a good chemical separation efficiency, and enrichment capability. Moreover, this process requires few water and energy.

Analysis of Broken Rice Separation Efficiency of a Laboratory Indented Cylinder Separator

  • Kim, Myoung Ho;Park, Seung Je
    • Journal of Biosystems Engineering
    • /
    • v.38 no.2
    • /
    • pp.95-102
    • /
    • 2013
  • Purpose: Using a laboratory indented cylinder separator, broken rice separation experiments were conducted and the characteristics of the separation process were studied to provide information for developing a prototype indented cylinder broken rice separator. Methods: Rice (Ilmi variety) milled in a local RPC was used for the experiment. Rice kernels were classified into four groups according to their length l; whole kernels (I > 3.75 mm), semi-whole kernels (2.5 < I < 3.75 mm), broken kernels (1.75 < I < 2.5 mm), and foreign matters (I < 1.75 mm). A laboratory grain cleaner, Labofix '90 (Schmidt AG, Germany) was used for the experiments. Experiments were designed as a $4{\times}4$ factorial arrangement in randomized blocks with three replications. Cylinder rotational speeds (17, 34, 51, 68 rpm) and trough angles (15, 37.5, 60, $82.5^{\circ}$) were the two factors and feed rates (25, 50 kg/h), indent shapes (Us, $S_1$ type), and indent sizes (2.5, 3.75 mm) were treated as the blocks. Two 125 g samples and one 125 g sample were taken at the cylinder outlet and from the trough, respectively. The whole, semi-whole, and broken kernel weight ratio of the samples and feed was determined by a rice sizing device. From these weight ratios, purities, degrees of extraction and coefficient of separation efficiency were calculated. Results: Trough angle, cylinder speed, and their interaction on the coefficient of separation efficiency were statistically significant. Cylinder speed of 17, 34, and 51 rpm made the most effective separation when the trough angle was $15^{\circ}$ or $37.5^{\circ}$, $60^{\circ}$, and $82.5^{\circ}$, respectively. Maximum values of coefficient of separation efficiency were in the range of 60 to 70% except when the indent size was 2.5 mm and were recorded for the combinations of low cylinder speed (17 rpm) with medium trough angle ($37.5^{\circ}$ or $60^{\circ}$). Indent shape did not appear to make any noticeable difference in separation efficiency. Conclusions: Due to the interaction effect, the trough angle needs to be increased appropriately when an increase in cylinder speed is made if a rapid drop of effectiveness of separation should be avoided. In commercial applications, $S_1$ type indents are preferred because of their better manufacturability and easier maintenance. For successful separation of broken kernels, the indent size should be set slightly bigger than the actual sizes of broken kernels: an indent size of 3.0 mm for separating broken kernels shorter than 2.5 mm.

A Study on the Separation of Mixed Waste Plastics by Trioboelectrification (마찰대전을 이용한 혼합폐플라스틱 분리에 관한 연구)

  • Lee, Jong-Ho;Shin, Jin-Hyuk;Kim, Doo-Hyun;Kim, Jang-Woo;Lee, Jae-Keun
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.538-543
    • /
    • 2000
  • The purpose of this study is to develope electrostatic separation system for recycling of mixed waste plastics. The electrostatic separation system is designed and investigated the separation efficiency for separating of mixed waste plastics. Electrostatic separation system consisted of a tribocharger, separator (two electrode), collector (5 tray) and controller (positive/negative high voltage power supply). The tribocharger is a fluidized bed using tribo-electrification mechanism between particles and particles. In experimental results, the tribocharger of the fluidized bed was more effective separation efficiency. It showed the purity of $85{\sim}99\;%$ and the recovery of $80{\sim}98\;%$ from the powder of mixed plastics such as LDPE, HDPE, PP, PS, PET and PVC. Especially, In the separation experiment of Polyvinylchloride(PVC) which generates hazardous hydrogen chloride gas in case of the combustion. its purity was over 99 % and recovery was over 95 %.

  • PDF

Analysis of High Volume Slit Type Two-Stage Virtual Impactor for Particle Size Classification (특정크기 입자농축을 위한 대유량 슬릿형 2단 가상충돌기의 성능분석)

  • 박성호;김상수;오명도
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.285-291
    • /
    • 1991
  • A two-stage slit type virtual impactor based on the concept of the single stage virtual impactor has been designed, fabricated, and evaluated for the purpose of concentrating the suspended particles in the air with the size range of 1.8-4.5 .mu.m and handling large flow volume. Monodisperse methylene blue particles have been generated with vibrating orifice aerosol generator (VOAG). The separation efficiency and concentration efficiency have been measured by the UV-visible absorption spectrometry. Previous study for a single stage virtual impactor were used to determine the design parameters such as 50% cut-off sizes and dimensions of the two stage virtual impactor. The separation efficiency curve and 50% cut-off Stokes number(cut-off sizes) are not sensitive to the nozzle Reynolds number, but sensitive to the ratio between the minor flow rate and the total flow rate, The measured concentration efficiency was compared with the maximum concentration efficiency determined by the separation efficiencies of the first and the second stages. The differences between the measured and the maximum concentration efficiencies result from the wall loss due to the deposited particles on the internal walls inside the impactor.

Development of Physical Treatment Technology for Stall Wastewater

  • Oh, In-Hwan;Park, Jeung-Hyun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.728-736
    • /
    • 1996
  • Solid/Liquid(S/L) separation is crucial for biological treatment of animal wastewater. Liquid portion from S/L separation has less BOD-load and proper post-strip treatment can be obtained . Screen or declined sieve was normally used to separate the solid parts. For better separating efficiency a vibration and a cylindrical separator were constructed and tested. The results are summarized as follows : Solids removal efficiency and moisture content of separated solid were 15-26% and 85-88%, respectively for the vibration separator. For the cylindrical separator, solid removal efficiency and moisture content of solid were 16-39% and 86-89% , respectively. The greatest amount of drymatter was obtained when operating vibration separator with 10。 inclination and 100% vibrating power. For the cylindrical separator maximum efficiency was obtained with 40rpm and 19 inclination . The vibration and the cylindrical separator have shown 21% and 26% in BOD removal, respectively. These two types of separator were proved to be applicable methods for animal wastewater separation.

  • PDF

Superconducting magnetic separation of ground steel slag powder for recovery of resources

  • Kwon, H.W.;Kim, J.J.;Ha, D.W.;Choi, J.H.;Kim, Young-Hun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.1
    • /
    • pp.22-25
    • /
    • 2017
  • Steel slag has been considered as an industrial waste. A huge amount of slag is produced as a byproduct and the steel slag usually has been dumped in a landfill site. However the steel slag contains valuable resources such as iron, copper, manganese, and magnesium. Superconducting magnetic separation has been applied on recovery of the valuable resources from the steel slag and this process also has intended to reduce the waste to be dumped. Cryo-cooled Nb-Ti superconducting magnet with 100 mm bore and 600 mm of height was used as the magnetic separator. The separating efficiency was evaluated in the function of magnetic field. A steel slag was ground and analyzed for the composition. Iron containing minerals were successfully concentrated from less iron containing portion. The separation efficiency was highly dependent on the particle size giving higher separating efficiency with finer particle. The magnetic field also effects on the separation ratio. Current study showed that an appropriate grinding of slag and magnetic separation lead to the recovery of metal resources from steel slag waste rather than dumping all of the volume.