• 제목/요약/키워드: sensorML

검색결과 105건 처리시간 0.028초

QPSK 신호 입력시스템에서의 유한 알파벹 기반 ML 블라인드 신호 추정 비교 (A Consideration on ML Blind Signal Estimation based on Finite-Alphabet Characteristic in QPSK Modulation)

  • 권순만;김석주;이종무;김춘경;천종민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.685-688
    • /
    • 2003
  • In this paper, a performance comparison between two blind signal estimation algorithms in a LTI channel is considered. The two algorithms, Iterative Least-Squares with Projection (ILSP) and a modified ILSP, are based on the finite-alphabet property of input symbols. This case typically arises in a multiple access system with a sensor array antenna at the receiving end. We start with the formulation of a maximum-likelihood (ML) estimation problem under an additive white Gaussian noise assumption. A blind ML estimator is derived with its iterative algorithm for calculation. Then we narrow down the consideration of this problem to QPSK case so that a modified algorithm is proposed for $\pi$/4-QPSK case. The modified version is compared with the original ILSP algorithm in terms of the rate of the convergence to global minima. A computer simulation shows that the modified algorithm gives a better performance. This result implies that the performance of the blind separation algorithms may be greatly improved by adopting a smart coding scheme with rich structure.

  • PDF

미소 유량 측정을 위한 마이크로 전자 유량 센서의 제작 (Fabrication of a Micro Electromagnetic Flow Sensor for Micro Flow Rate Measurement)

  • 윤현중;김순영;양상식
    • 센서학회지
    • /
    • 제9권5호
    • /
    • pp.334-340
    • /
    • 2000
  • 본 논문에서는 패러데이의 전자기 유도 법칙을 응용한 마이크로 전자 유량 센서를 제작하였다. 마이크로전자 유량 센서는 열 발생이 없고 빠른 응답 속도를 가지고 있고 압력 손실이 없는 장점을 가지고 있다. 전도성 유체가 영구 자석 자장 내의 유로를 통과할 때, 유속에 비례하는 유도 기 전력이 발생하게 되는데, 발생된 기 전력은 유로 벽에 제작된 전극으로 검출된다. 마이크로 전자 유량 센서는 유로를 가지고 있는 두 장의 실리콘 웨이퍼 기판과 전극, 그리고 두 개의 영구 자석으로 구성되어 있다. 두 장의 실리콘 웨이퍼 기판을 이방성 식각 공정으로 유로를 제작하고, Cr/Au를 증착하여 전극을 제작한다. 제작된 마이크로 전자 유량 센서에 유량을 변화시킬 때, 발생되는 기 전력을 측정한다.

  • PDF

단백질 측정용 SH-SAW 센서 개발 (Development of an SH-SAW Sensor for Protein Measurement)

  • 권용준;김재호;고광락;노용래
    • 한국음향학회지
    • /
    • 제23권1호
    • /
    • pp.1-7
    • /
    • 2004
  • 본 연구에서는 항원-항체 결합반응을 통해 액상의 단백질 분자를 감지할 수 있는 SH형 SAW센서를 개발하였다. 측정하고자 하는 항원으로는 anti-Human-immune-globulin (anti-HigG) 단백질을, 이에 대응하는 항체로는 HigG를 채택하였다. 압전 단결정 LiTaO₃를 사용하여 100 MHz로 발진되는 센서를 제작하고, 센서의 지연선 위에 Ti/Au층을 증착하였다. 증착된 Au층 위에 SAM (self assembled monolayer)을 형성시켜서 추가되는 항원의 농도에 의한 센서의 주파수 변화를 측정하였다. 개발된 센서의 최소검출단위는 노이즈 레벨 400 Hz 이하 값에 10.8 ng/ml/Hz의 민감도를 가지며, anti-HigG 항원의 질량하중 효과에 대해 안정적인 반응을 보였다.

FET형 요소 감지 소자 (FET type Urea Sensor)

  • 문병준;이종현;손병기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.490-492
    • /
    • 1987
  • Urea-Sensor was fabricated by immobilizing urease on ISFET's gate using BSA(bovine serum albumin) and glutaraldehyde, and its characteristics were examined. This sensor showed approximately linear characteristic in the urea concentration range of $3{\times}10^{-5}-10^{-9}$ (g/ml). Fast response time was obtained and minute amounts of expensive enzyme were used in comparison to general electrode type biosensors.

  • PDF

SSNO 기반 시공간 시맨틱 센서 웹 (Spatio-Temporal Semantic Sensor Web based on SSNO)

  • 신인수;김수정;김정준;한기준
    • Spatial Information Research
    • /
    • 제22권5호
    • /
    • pp.9-18
    • /
    • 2014
  • 유비쿼터스 컴퓨팅 환경이 발전함에 따라 GeoSensor와 같이 GPS 기능을 보유한 센서로부터 생성된 시공간 센서 데이터 활용이 증가하고 있으며, 시공간 센서 데이터를 사용해 사용자에게 다양한 서비스를 효율적으로 제공해주기 위한 시맨틱 센서 웹이 연구되고 있다. 특히, W3C에서는 OGC의 SWE(Sensor Web Enablement)와 같은 센서 관련 표준들을 활용하고, 센서 데이터를 온톨로지로 표현할 수 있는 SSNO(Semantic Sensor Network Ontology)를 개발하였다. 그러나 이러한 연구들은 비시공간 센서 데이터에 대한 질의 처리는 가능하지만 시간과 공간 정보를 포함하는 시공간 센서 데이터를 효율적으로 처리하기 어렵다는 문제점이 존재한다. 따라서, 본 논문에서는 OGC의 "OpenGIS Simple Feature Specification for SQL"에서 제시한 공간 데이터 타입과 공간 연산자를 확장하여 시공간 데이터 타입과 시공간 연산자를 지원하는 SSNO 기반의 시공간 시맨틱 센서 웹을 개발하였다. SSNO 기반의 시공간 시맨틱 센서 웹은 시공간 센서 데이터인 SensorML(Sensor Model Language)과 O&M(Observations and Measurements) 스키마를 분석하여 SSNO 문서로 변환 및 저장하고, 시공간 연산자와 시공간 추론 규칙을 적용하여 효율적인 질의 처리를 수행한다. 마지막으로, 이러한 SSNO 기반의 시공간 시맨틱 센서 웹을 가상 시나리오에 적용해 봄으로써 본 시스템의 효용성을 검증하였다.

μFIA 바이오 센서를 이용한 포도당 농도 측정 (Measurement of Glucose Concentration Using a μFIA Biosensor)

  • 송대빈
    • Journal of Biosystems Engineering
    • /
    • 제28권5호
    • /
    • pp.465-468
    • /
    • 2003
  • A microdialysis coupled flow injection amperometric biosensor was calibrated to measure the concentration of glucose using 7 standard samples from 10ml to 70ml of glucose solution. The output of the sensor increased linearly with an increase in the glucose concentration with an $R^2$ correlation of 0.99. The amperometric biosensor was then applied to measure the. glucose concentration of 2 commercial samples(Orange and Pineapple juice) and the results compared with HPLC. Around 12% error was observed in glucose concentration measurements of the samples analyzed. The sensor has potential in rapid measurement once the calibration is done. Potential for on-line sensing is also discussed.

μFIA 바이오센서를 이용한 자당 농도 측정 (Measurement of Sucrose Concentration Using a μFIA Biosensor)

  • 송대빈
    • Journal of Biosystems Engineering
    • /
    • 제29권6호
    • /
    • pp.553-557
    • /
    • 2004
  • A microdialysis coupled flow injection amperometric $({\mu}FIA)$ biosensor was calibrated to measure the concentration of sucrose using 11 standard samples from 2 ml to 70 ml of sucrose solution. The output of the sensor increased linearly with an increase in the sucrose concentration with an $r^2$ correlation of 0.99. The amperometric biosensor was then applied to measure the sucrose concentration of 4 commercial samples (Orange and Pineapple juices, Pepsi, Sprite) and the results compared with those by HPLC. Around $20\~30\%$ error was observed in sucrose concentration measurements of the samples analyzed. The sensor has potential in rapid measurement once the calibration is done. Potential for on-line sensing is also discussed.

Evaluation of Two Types of Biosensors for Immunoassay of Botulinum Toxin

  • Choi, Ki-Bong;Seo, Won-Jun;Cha, Seung-Hee;Choi, Jung-Do
    • BMB Reports
    • /
    • 제31권1호
    • /
    • pp.101-105
    • /
    • 1998
  • Immunoassay of botulinum toxin (BTX) B type was investigated using two typed of biosensors: light addressable potentiometric sensor (LAPS) and surface plasmon resonance (SPR) sensor. Urease-tagged and immuno-filtration capture method have been used for LAPS. Tag-free and direct binding real-time detection method have been used for SPR sensor. The detection limit of sandwich assay format with LAPS was 10 ng/ml, which was the lowest among methods tested. SPR has the advantage of being more convenient because tag-free direct binding assay can be used and reaction time was reduced, regardless of low sensitivity. This result shows that sandwich assay format with LAPS can be used as an alternative method of BTX mouse bioassay which is known as the most sensitive method for the detection of BTX.

  • PDF

광섬유 소산장을 이용한 식중독균 신속검출용 형광면역센서 (Fiber-optic fluoroimmunosensor for foodborn pathogens using an optical evanescent field)

  • 염세혁;박창섭;김도억;김규진;강병호;강신원
    • 센서학회지
    • /
    • 제16권6호
    • /
    • pp.441-448
    • /
    • 2007
  • In this study, the fiber-optic fluoro-immunosensor was designed to detect foodborne pathogens. The fabricated system is composed of the multimode optical fiber on which antibodies are immobilized. Then, a sandwich immunoassay is applied to the fabricated the fiber-optic fluoro-immunosensor. In the "sandwich" binding format, a primary or "capture" antibody is immobilized on the core surface of the multimode optical fiber and a secondary or named as "tracer" antibody is added to the bulk solution. A tracer is labeled FITC (fluorescein isothiocyanate; ${\lambda}ex$=492 nm, ${\lambda}em$= 520 nm). Different concentrations of antigens are tested in different fibers. The detection limit of the fabricated system is 5.08×103 cfu/ml for Vibrio antigen and $0.1{\mu}g/ml$, $0.05{\mu}g/ml$ in non-labeled monolayer phosphate buffered saline (NMP), non-labeled monolayer carbonate bicarbonate buffer (NMC), respectively.

신속한 BOD 측정장치의 개발과 응용 (Development of Assembly for Fast BOD Estimation and Its Applications)

  • 손무정;김은정;장세용;홍대일
    • 분석과학
    • /
    • 제7권3호
    • /
    • pp.285-291
    • /
    • 1994
  • Trichosporon cutaneum을 투석막과 기체투과막 사이에 고정화시켜 산소전극에 부착함으로써 연속적으로 측정할 수 있는 BOD 센서를 개발하였다. 이 센서의 최적 조건은 pH 7.0, $32{\sim}33^{\circ}C$의 온도, $2{\sim}3ml/min$의 flow rate 및 0.1M phosphate 완충용액이었다. ${\Delta}DO$에 대하여 GGA 표준용액의 농도를 도시하였을 때 GGA 60mg/l 이하에서 직선성을 나타니었으며, 30mg/L의 GGA를 사용하였을 때 재현성은 3%의 오차범위를 나타내었다. DO값은 30일 동안 거의 일정하였으며, 감응시간과 회복시간은 각각 약 5분과 10분이었다. 이 센서를 이용하여 실제 폐수의 BOD를 측정하여 $BOD_5$법과 비하였다.

  • PDF