LC-MS/MS를 이용한 마비성패류독소 분석조건 검토 (Paralytic Shellfish Poisoning (PSP) Analysis using Liquid Chromatography-Tandem Mass Spectrometry)

  • 송기철;이가정;유홍식;목종수;김지회;임근식;이미애
    • 한국수산과학회지
    • /
    • 제46권2호
    • /
    • pp.154-159
    • /
    • 2013
  • The AOAC Mouse Bioassay method (MBA) has been widely used for routine monitoring of paralytic shellfish poisoning (PSP) for more than 50 years. However, this method has low sensitivity and experiences interference from other components in the extract. Also, ethical issues have been raised against the continued use of this live-mouse assay. To establish an alternative method for PSP analysis, we attempted to develop PSP analysis conditions using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The LC-MS/MS analysis of reference material showed very reasonable accuracy, and the analysis time was just 15 min. However, the recovery rate of toxin spike samples using the LC-MS/MS analysis was 59.4-91.0%. We also attempted to remove the matrix effect using shellfish extracts, but recoveries of C1 and C2 did not improve. A comparison between the results of MBA and LC-MS/MS analysis revealed good correlations, with values of 0.8878 and 0.9211 for oyster and mussel matrices, respectively.

Highly Sensitive Gas Sensors Based on Nanostructured $TiO_2$ Thin Films

  • 장호원;문희규;김도홍;심영석;윤석진
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.16.1-16.1
    • /
    • 2011
  • $TiO_2$ is a promising material for gas sensors. To achieve high sensitivities, the material should exhibit a large surface-to-volume ratio and possess the high accessibility of the gas molecules to the surface. Accordingly, a wide variety of porous $TiO_2$ nanomaterials synthesized by wet-chemical methods have been reported for gas sensor applications. Nonetheless, achieving the large-area uniformity and comparability with well-established semiconductor production processes of the methods is still challenging. An alternative method is soft-templating which utilizes nanostructured inorganic or organic materials as sacrificial templates for the preparation of porous materials. Fabrication of macroporous $TiO_2$ films and hollow $TiO_2$ tubes by soft-templating and their gas sensing applications have been reported recently. In these porous materials composed of assemblies of individual micro/nanostructures, the form of links or necks between individual micro/nanostructures is a critical factor to determine gas sensing properties of the material. However, a systematic study to clarify the role of links between individual micro/nanostructures in gas sensing properties of a porous metal oxide matrix is thoroughly lacking. In this work, we have demonstrated a fabrication method to prepare highly-ordered, embossed $TiO_2$ films composed of anatase $TiO_2$ hollow hemispheres via soft-templating using polystyrene beads. The form of links between hollow hemispheres could be controlled by $O_2$ plasma etching on the bead templates. This approach reveals the strong correlation of gas sensitivity with the form of the links. Our experimental results highlight that not only the surface-to-volume ratio of an ensemble material composed of individual micro/nanostructures but also the links between individual micro/nanostructures play a critical role in evaluating the sensing properties of the material. In addition to this general finding, the facileness, large-scale productivity, and compatability with semiconductor production process of the proposed fabrication method promise applications of the embossed $TiO_2$ films to high-quality sensors.

  • PDF

Reverse transcription loop-mediated isothermal amplification assay for the rapid and simultaneous detection of H5 and other subtypes of avian influenza viruses

  • Park, Yu-Ri;Kim, Eun-Mi;Han, Do-Hyun;Kang, Dae-Young;Yeo, Sang-Geon;Park, Choi-Kyu
    • 한국동물위생학회지
    • /
    • 제40권1호
    • /
    • pp.15-20
    • /
    • 2017
  • A two-tube reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was designed for the rapid visual detection of the M gene of all subtypes of avian influenza virus (AIV) and the H5 gene of the H5 subtype of highly pathogenic AIV (HPAIV). The reaction carried out in two tubes in a single step at $58^{\circ}C$ for 40 min, and the assay results could be visually detected by using hydroxynaphthol blue dye. Using M or H5 gene-specific primers, the assay successfully detected all subtypes or H5 subtypes of AIVs, including the Korean representative H5N1 and H5N8 HPAIVs. The detection limit of the assay was approximately $10^{2.0}$ $EID_{50}/reaction$ for the M and H5 genes of H5N1 HPAIV, respectively, and was more sensitive than that of previously reported RT-LAMP and comparable to that of real-time RT-PCR. These results suggest that the present RT-LAMP assay, with its high specificity, sensitivity, and simplicity, will be a useful diagnostic tool for surveillance of currently circulating H5 HPAIVs and other subtypes of AIV in bird population, even in under-equipped laboratories.

Plasma Lipidomics as a Tool for Diagnosis of Extrahepatic Cholangiocarcinoma in Biliary Strictures: a Pilot Study

  • Prachayakul, Varayu;Thearavathanasingha, Phataraphong;Thuwajit, Chanitra;Roytrakul, Sittiruk;Jaresitthikunchai, Janthima;Thuwajit, Peti
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권8호
    • /
    • pp.4155-4161
    • /
    • 2016
  • Biliary obstruction is a common clinical manifestation of various conditions, including extrahepatic cholangiocarcinoma. However, a screening test for diagnosis of extrahepatic cholangiocarcinoma in patients with biliary obstruction is not yet available. According to the rationale that the biliary system plays a major role in lipid metabolism, biliary obstruction may interfere with lipid profiles in the body. Therefore, plasma lipidomics may help indicate the presence or status of disease in biliary obstruction suspected extrahepatic cholangiocarcinoma. This study aimed to use plasma lipidomics for diagnosis of extrahepatic cholangiocarcinoma in patients with biliary obstruction. Plasma from healthy volunteers, patients with benign biliary obstruction extrahepatic cholangiocarcinoma, and other related cancers were used in this study. Plasma lipids were extracted and lipidomic analysis was performed using matrix-assisted laser desorption ionization time-of-flight mass spectrometry. Lipid profiles from extrahepatic cholangiocarcinoma patients showed significant differences from both normal and benign biliary obstruction conditions, with no distinction between the latter two. Relative intensity of the selected lipid mass was able to successfully differentiate all extrahepatic cholangiocarcinoma samples from patient samples taken from healthy volunteers, patients with benign biliary obstruction, and patients with other related cancers. In conclusion, lipidomics is a non-invasive method with high sensitivity and specificity for identification of extrahepatic cholangiocarcinoma in patients with biliary obstruction.

Diagnosis and prediction of periodontally compromised teeth using a deep learning-based convolutional neural network algorithm

  • Lee, Jae-Hong;Kim, Do-hyung;Jeong, Seong-Nyum;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제48권2호
    • /
    • pp.114-123
    • /
    • 2018
  • Purpose: The aim of the current study was to develop a computer-assisted detection system based on a deep convolutional neural network (CNN) algorithm and to evaluate the potential usefulness and accuracy of this system for the diagnosis and prediction of periodontally compromised teeth (PCT). Methods: Combining pretrained deep CNN architecture and a self-trained network, periapical radiographic images were used to determine the optimal CNN algorithm and weights. The diagnostic and predictive accuracy, sensitivity, specificity, positive predictive value, negative predictive value, receiver operating characteristic (ROC) curve, area under the ROC curve, confusion matrix, and 95% confidence intervals (CIs) were calculated using our deep CNN algorithm, based on a Keras framework in Python. Results: The periapical radiographic dataset was split into training (n=1,044), validation (n=348), and test (n=348) datasets. With the deep learning algorithm, the diagnostic accuracy for PCT was 81.0% for premolars and 76.7% for molars. Using 64 premolars and 64 molars that were clinically diagnosed as severe PCT, the accuracy of predicting extraction was 82.8% (95% CI, 70.1%-91.2%) for premolars and 73.4% (95% CI, 59.9%-84.0%) for molars. Conclusions: We demonstrated that the deep CNN algorithm was useful for assessing the diagnosis and predictability of PCT. Therefore, with further optimization of the PCT dataset and improvements in the algorithm, a computer-aided detection system can be expected to become an effective and efficient method of diagnosing and predicting PCT.

Micromechanical 시험법과 AE를 이용한 PVDF 함침 고분자 복합재료의 계면손상감지능 및 비파괴적 평가 연구 (Nondestructive Evaluation and Interfacial Damage Sensing of PVDF embedded Polymer Composites using Micromechanical Techniques and Acoustic Emission)

  • Kong, Jin-Woo;Park, Joung-Man;Kim, Ki-Bok;Yoon, Dong-Jin
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 추계학술발표대회 논문집
    • /
    • pp.216-219
    • /
    • 2002
  • Conventional piezoelectric lead-zirconate-titanate (PZT) senor has high sensitivity, but it is very brittle. Recently polymer films such as polyvinylidene fluoride (PVDF) have been used use as a sensor. The advantages of PVDF are the flexibility and mechanical toughness. Simple process and possible several shapes are also additional advantages. PVDF sensor can be directly embedded and attached to a structure. In this study, PVDF sensor was embedded in single glass fiber/epoxy composites whereas PZT sensor with AE was attached to single fiber composites (SFC). Piezoelectric sensor responds to interfacial damage of SFC. The signals measured by PVDF sensor were compared to PZT sensor. PZT sensor detected the signals of fiber fracture, matrix crack, interfacial debonding and even sensor delamination, whereas PVDF sensor only detected fiber fracture signals so far, because PZT sensor is much more sensitive than current PVDF sensor. Wave voltage of fiber fracture measured by PVDF sensor was lower than that of PZT sensor, but the results of fast Fourier transform (FFT) analysis were same. Wave velocity using two PZT sensors was also studied to know the internal and surface damage effect of epoxy specimens.

  • PDF

투과형 광탄성 실험법에 의한 지능성 FRP의 파괴지연 효과에 관한 연구 (A Study on the Effect of Fracture Delay of Intelligent FRP by Transparent Photoelastic Experimental Method)

  • 이효재;황재석
    • 대한기계학회논문집A
    • /
    • 제23권11호
    • /
    • pp.1904-1911
    • /
    • 1999
  • The most effective material in the shape memory alloy(SMA) is the TiNi alloy, because its shape recovery characteristics are very excellent. We molded the composite material with shape memory function. The fiber of it is $Ti_{50}-Ni_{50}$ shape memory alloy and matrix of it is epoxy resin(Araldite B41, Hardner HT903. Ciba Geigy), its adhesive and optical sensitivity are very excellent. It was assured that the composite material could be used as model material of photoelastic experiment for intelligent materials or structures. In this research, the composite material with shape memory function is used as model material of photoelastic experiment. Photoelastic experimental hybrid method is developed in this research, it is assured that it is useful on the obtaining stress intensity factor and the separation of stress components from only isochromatic data. The measuring method of stress intensity factor of intelligent material by photoelastic experiment is introduced. In the mode I state, we can know that stress intensity factors are decreased more than 50% of stress intensity factor of room temperature when temperature of fiber is greater than 4$0^{\circ}C$, prestrain greater than 5% and fiber volume ratio greater than 0.42% and that stress intensity factors are decreased by 100% when fiber volume ratio is greater than 0.84%, prestrain greater than 5% and temperature greater than 60 $^{\circ}C$.

Detection of MicroRNA-21 Expression as a Potential Screening Biomarker for Colorectal Cancer: a Meta-analysis

  • Jiang, Jian-Xin;Zhang, Na;Liu, Zhong-Min;Wang, Yan-Ying
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권18호
    • /
    • pp.7583-7588
    • /
    • 2014
  • Background: Colorectal cancer (CRC) is a major cause of cancer-related death and cancer-related incidence worldwide. The potential of microRNA-21 (miR-21) as a biomarker for CRC detection has been studied in several studies. However, the results were inconsistent. Therefore, we conducted the present meta-analysis to systematically assess the diagnostic value of miR-21 for CRC. Materials and Methods: Using a random-effect model, the pooled sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were calculated to evaluate the diagnostic performance of miR-21 for CRC. A summary receiver operating characteristic (SROC) curve and an area under the curve (AUC) were also generated to assess the diagnosis accuracy of miR-21 for CRC. Q test and I2 statistics were used to assess between-study heterogeneity. Publication bias was evaluated by the Deeks' funnel plot asymmetry test. Results: A total of 986 CRC patients and 702 matched healthy controls from 8 studies were involved in the meta-analysis. The pooled results for SEN, SPE, PLR, NLR, DOR, and AUC were 57% (95%CI: 39%-74%), 87% (95%CI: 78%-93%), 4.4 (95%CI: 2.4-8.0), 0.49 (95%CI: 0.32-0.74), 9 (95%CI: 4-22), and 0.83 (95%CI: 0.79-0.86), respectively. Subgroup analyses further suggested that blood-based studies showed a better diagnostic accuracy compared with feces-based studies, indicating that blood may be a better matrix for miR-21 assay and CRC detection. Conclusions: Our findings suggest that miR-21 has a potential diagnostic value for CRC with a moderate level of overall diagnostic accuracy. Hence, it could be used as auxiliary means for the initial screening of CRC and avoid unnecessary colonoscopy, which is an invasive and expensive procedure.

흑염소 간-조직과 Ferrocene 매개체를 사용한 과산화수소정량 전류법 바이오센서 (Amperometric Biosensor for Hydrogen Peroxide Determination Based on Black Goat Liver-Tissue and Ferrocene Mediation)

  • 권효식;박인근;김양숙
    • 대한화학회지
    • /
    • 제48권5호
    • /
    • pp.491-498
    • /
    • 2004
  • 흑염소의 간-조직과 ferrocene을 탄소반죽 전극에 고정하여 과산화수소를 정량할 수 있는 전극을 만들었다. Ag/AgCl 전극에 대하여 $-0.3{\sim}+0.0\;V$의 전위 범위에서 전극의 감도를 관찰하였으며 전극의 감응시간은 12 s로 나타났다. 전극의 검출한계는 2.25${\times)10^{-6}M$ (S/N=3)이었으며,1.0${\times}10^{-2 }$M 과산화수소를 이용해 15회 반복 측정한 결과, 상대표준편차는 1.87%이었다. 또한, 방해물질의 영향도 없는 것으로 나타났다. 효소전극의 감도는 19일 사용 후 50%로 감소하였다.

철도 구조물용 맞대기 용접시편 가공에 의한 피로수명 영향 및 용접부 형상을 이용한 피로수명 예측 연구 (A Study on the Effects of the Fatigue Life due to the Processing of the Butt Weld Specimens and the Fatigue Life Estimation due to the Weld Zone Profiles)

  • 김재훈
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.371-378
    • /
    • 2006
  • This study investigates the effects of the material properties and the fatigue behaviors in the SM490A material butt weld specimens due to the heat-treatment and the grinding. In the fatigue behavior, the heat-treatment affects the fatigue life. The S-N curves of both matrix specimen and butt weld specimen are reversed at some cycle by the existence or nonexistence of heat-treatment. The grinding on the bead makes the fatigue limit decrease in the all specimens. But the reinforcement removed, the fatigue limit increases at the high cycle. Also, this study investigates the fatigue life estimation by examining butt weld bead profiles. The butt weld beads, which are welded by semi-robot method, have non-uniform bead profiles described by $\theta,\;\rho$ and h. The stress concentration factors $K_t$, are changed by each different $\theta,\;\rho$ and h from 1.395 to 2.863. Hence, the sensitivity of $K_t$ is changed by each $\theta,\;\rho$ and h. As $\theta$ becomes lower and $\rho$ and h become higher, $K_t$ increases. The fatigue life can he estimated very closely for the AAY specimens without residual stress using only butt weld bead profiles. But, fur the AAN specimens with residual stress, the fatigue life must be estimated by considering both the weld bead profiles and the residual stress data.