• 제목/요약/키워드: sensitivity and specificity

검색결과 2,186건 처리시간 0.034초

Clinical Impact and Reliability of Carbonic Anhydrase XII in the Differentiation of Malignant and Tuberculous Pleural Effusions

  • Liu, Yun-Long;Jing, Li-Ling;Guo, Qi-Sen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권1호
    • /
    • pp.351-354
    • /
    • 2013
  • Objective: To assess the practical utility of pleural fluid carbonic anhydrase XII (CAXII) quantification for differential diagnosis of effusions. Materials and Methods: Fluid was collected prospectively from fifty patients presenting with lymphocytic pleural effusions for investigation and CAXII was quantified by ELISA. Results: Pleural fluid CAXII concentrations were significantly higher in lung cancer patients (n=30) than in tuberculous controls (n=20). The sensitivity and specificity of this biomarker were 60%and 75%, respectively. CAXII measurement was not inferior to cytological examination in the diagnosis and exclusion of pleural effusions from lung cancer patitents (sensitivity 60% vs. 57%; specificity 75% vs. 100%; positive predictive value 77%; negative predictive value 54%). In patients with negative cytology, it offered a sensitivity of 54%. Conclusions: Pleural fluid CAXII is elevated in pleural effusions from lung cancer patients. Measurement of CAXII may be used in the future as a valuable adjunct to cytology in the diagnostic assessment of patients with pleural effusions related to lung cancer, especially when cytological examination is inconclusive.

낙상 위험 선별검사 Timed Up and Go test의 예측 타당도 메타분석 (A Meta-analysis of the Timed Up and Go test for Predicting Falls)

  • 박성희;이언석
    • 한국의료질향상학회지
    • /
    • 제22권2호
    • /
    • pp.27-40
    • /
    • 2016
  • Purpose: Globally, falls are a major public health problem. The study aimed to evaluate the predictive validity of the Timed Up and Go test (TUGT) as a screening tool for fall risk. Methods: An electronic search was performed Medline, EMBASE, CINAHL, Cochran Library, KoreaMed and the National Digital Science Library and other databases, using the following keywords: 'fall', 'fall risk assessment', 'fall screening', 'mobility scale', and 'risk assessment tool'. The QUADAS-II was applied to assess the internal validity of the diagnostic studies. Thirteen studies were analyzed using meta-analysis with MetaDisc 1.4. Results: The selected 13 studies reporting predictive validity of TUGT of fall risks were meta-analyzed with a sample size of 1004 with high methodological quality. Overall predictive validity of TGUT was as follows. The pooled sensitivity 0.72 (95% confidence interval [CI]: 0.67-0.77), pooled specificity 0.58 (95% CI: 0.54-0.63) and sROC AUC was 0.75 respectively. Heterogeneity among studies was a moderate level in sensitivity. Conclusion: The TGUT's predictive validity for fall risk is at a moderate level. Although there is a limit to interpret the results for heterogeneity between the literature, TGUT is an appropriate tool to apply to all patients at a potential risk of accidental fall in a hospital or long-term care facility.

Array-based Nano-amplification Technique Was Applied in Detection of Hepatitis E Virus

  • Liu, Hui-Hui;Cao, Xuan;Yang, Yong;Liu, Ming-Gui;Wang, Ye-Fu
    • BMB Reports
    • /
    • 제39권3호
    • /
    • pp.247-252
    • /
    • 2006
  • A rapid method for the detection of Hepatitis E Virus (HEV) was developed by utilizing nano-gold labeled oligonucleotide probes, silver stain enhancement and the microarray technique. The 5'-end -$NH_2$ modified oligonucleotide probes were immobilized on the surface of the chip base as the capture probe. The detection probe was made of the 3'-end -SH modified oligonucleotide probe and nano-gold colloid. The optimal concentrations of these two probes were determined. To test the detection sensitivity and specificity of this technique, a conservative fragment of the virus RNA was amplified by the RT-PCR/PCR one step amplification. The cDNA was hybridized with the capture probes and the detection probes on microarray. The detection signal was amplified by silver stain enhancement and could be identified by naked eyes. 100 fM of amplicon could be detected out on the microarray. As the results, preparation of nano-gold was improved and faster. Development time also was shortened to 2 min. Thus, considering high efficiency, low cost, good specificity and high sensitivity, this technique is alternative for the detection of HEV.

Mammography and Ultrasonography Reports Compared with Tissue Diagnosis - An Evidence Based Study in Iran, 2010

  • Akbari, Mohammad Esmaeil;Haghighatkhah, Hamidreza;Shafiee, Mohammad;Akbari, Atieh;Bahmanpoor, Mitra;Khayamzadeh, Maryam
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권5호
    • /
    • pp.1907-1910
    • /
    • 2012
  • Background: Breast cancer is the most prevalent cancer and the fifth cause of cancer death in Iranian women. Early detection and treatment are important for appropriate management of this disease. Mammography and ultrasonography are used for screening and evaluation of symptomatic cases and the main diagnostic test for breast cancer is pathological. In this study we evaluated mammography and ultrasonography as diagnostic tools. Methods: In this cross-sectional study 384 mammography and ultrasonography reports for 255 women were assessed, divided into benign and malignant groups. Suspected cases were referred for pathology evaluation. The radiologic and pathologic reports were compared and also comparison was performed based on age groups (more and less than 50 years old), history of breastfeeding and gravidity. Statistical analysis was performed by SPSS. Results: The mean ages of malignant and benign cases were $49{\pm}11.6$ and $43{\pm}11.2$ years, respectively. Sensitivity and specificity for mammography were 73% and 45%, respectively. Sensitivity and specificity for ultrasonography were 69% and 49%, respectively. There were statistical differences between specificity of mammography in patients based on factors such as history of gravidity, breastfeeding and sensitivity in patients equal or more than 50 years old and less. Conclusion: Factors affecting different results in mammography and ultrasonography reports were classified into three groups, consisting of skill, experience and training of medical staff, and setting of instruments. It is recommended that health managers in developing countries pay attention the quality of setting and man power more than current status. Policy-makers and managers must establish guidelines regarding breast imaging in Iran.

Diagnostic accuracy of a combination of salivary hemoglobin levels, self-report questionnaires, and age in periodontitis screening

  • Maeng, You-Jin;Kim, Bo-Ra;Jung, Hoi-In;Jung, Ui-Won;Kim, Hee Eun;Kim, Baek-Il
    • Journal of Periodontal and Implant Science
    • /
    • 제46권1호
    • /
    • pp.10-21
    • /
    • 2016
  • Purpose: This study evaluated the predictive performance of a combination of self-report questionnaires, salivary hemoglobin levels, and age as a non-invasive screening method for periodontitis. Methods: The periodontitis status of 202 adults was examined using salivary hemoglobin levels, responses to 10 questions on a self-report questionnaire, and the Community Periodontal Index (CPI). The ability of those two variables and the combination thereof with age to predict the presence of CPI scores of 3-4 and 4 was assessed using logistic regression and receiver operating characteristic (ROC) curve analysis. Results: CPI scores of 3-4 and 4 were present among 79.7% and 46.5% of the sample, respectively. The area under the ROC curves (AUROCs) of salivary hemoglobin levels for predicting prevalence of CPI scores of 3-4 and 4 were 0.63 and 0.67, respectively (with sensitivity values of 71% and 60% and specificity values of 56% and 72%, respectively). Two distinct sets of five questions were associated with CPI scores of 3-4 and 4, with AUROCs of 0.73 and 0.71, sensitivity values of 76% and 66%, and specificity values of 63% and 69%. The combined model incorporating both variables and age showed the best predictive performance, with AUROCs of 0.78 and 0.76, sensitivity values of 71% and 65%, and specificity values of 68% and 77% for CPI scores of 3-4 and 4, respectively. Conclusions: The combination of salivary hemoglobin levels and self-report questionnaires was shown to be a valuable screening method for detecting periodontitis.

Comparison of Diagnostic Accuracies of Serum HE-4 Levels and 3D Power Doppler Angiography Parameters between Benign Endometrial Pathologies and Endometrial Cancer

  • Erenel, Hakan;Bese, Tugan;Sal, Veysel;Demirkiran, Fuat;Arvas, Macit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권5호
    • /
    • pp.2507-2511
    • /
    • 2016
  • Purpose: To study the diagnostic accuracies of serum human epididymis protein 4 (HE-4) levels, virtual organ computer-aided analysis (VOCAL) parameters and endometrial volume in endometrial cancer cases. Materials and Methods: One hundred and seven patients (37 with endometrial cancer and 70 with benign endometrial pathology) were included in this study. VOCAL parameters and serum HE-4 levels were compared between the groups. Results: Area under the curve (AUC) values were 0.702, 0.658, 0.706 for vascularization index (VI), the flow index (FI) and the vascularization flow index (VFI), respectively. A cut off value of 0.568 for VI demonstrated 70% sensitivity, 72% specificity, 56% positive predictive value (PPV) and a81% negative predictive value (NPV). A cut off value of 25.8 for showed a senitivith of 70% and a specificity of 58% with aPPV of 46% and NPV of 78%, and with a cut off value of 0.12 for VFI 70%, 69%, 54% and 81%, respectively. The area under the curve for HE-4 was 0.814. A cut off value of 458 pmol/L was predictive of malignancy with 86% sensitivity and 63% specificity. Conclusions: VOCAL parameters and serum HE-4 levels were statistically significantly higher in the endometrial cancer patients. Serum HE-4 levels provided a greater sensitivity compared to power doppler angiography for predicting malignancy or benign endometrial pathology.

Rapid Identification of Candida albicans Using Colorimetric Method

  • Kim, Shin Young;Park, Hun-Hee
    • 대한임상검사과학회지
    • /
    • 제45권4호
    • /
    • pp.149-153
    • /
    • 2013
  • Candidiasis is a fungal infection of the most common causes; generally, opportunistic infections occur often in patients with weakened immune systems. Because of high rates in fungal infection patients and increasing frequency of being isolated from clinical materials, quickly identifying of Candida albicans is critical. By identifying 404 yeast cell strains of referred samples via API 20C kits, NGL and PRO tests and Germ tube (GT) test were conducted and compared. In the 3.0 McFarland yeast cells, 0.1% ${\rho}-nitrophenyl-N-acetyl-{\beta}-D-galactosaminide$ (NGL) and 0.04% ${\small{L}}$-proline ${\beta}$-naphtylamide (PRO) were each put in test tubes and incubated at $35^{\circ}C$ for 15, 30, 60 and 90 minutes. Afterwards, 1 drop of 2% NaOH was applied, and if the color turned yellow; it was positive for NGL test. Afterwards, 1% ${\rho}$-dimethylaminocinnamaldehyde was applied, and if the upper layer turned pink or red, it was positive for PRO test. NGL and PRO tests were conducted for all C. albicans and identified accurately within 30 minutes. In NGL, PRO test, false-positive, negative were not seen, whereas, GT test showed false-positive in 1 strain and false-negative in 3 strains. Therefore, sensitivity and specificity of NGL, PRO tests were 100% and 99.5%, respectively, and positive and negative predictive rate were 99.5% and 100%, respectively. However, GT test sensitivity and specificity were 98.5% and 99.5%, respectively, and positive and negative predictive rates were 99.5% and 98.5%, respectively. In conclusion, NGL, PRO tests are better than GT tests for sensitivity and specificity, therefore, these reliable tests will be useful in clinical laboratories.

  • PDF

Assessment of vertical root fracture using cone-beam computed tomography

  • Moudi, Ehsan;Haghanifar, Sina;Madani, Zahrasadat;Alhavaz, Abdolhamid;Bijani, Ali;Bagheri, Mohammad
    • Imaging Science in Dentistry
    • /
    • 제44권1호
    • /
    • pp.37-41
    • /
    • 2014
  • Purpose: The aim of this study was to investigate the accuracy of cone-beam computed tomography (CBCT) in the diagnosis of vertical root fractures in a tooth with gutta-percha and prefabricated posts. Materials and Methods: This study selected 96 extracted molar and premolar teeth of the mandible. These teeth were divided into six groups as follows: Groups A, B, and C consisted of teeth with vertical root fractures, and groups D, E, and F had teeth without vertical root fractures; groups A and D had teeth with gutta-percha and prefabricated posts; groups B and E had teeth with gutta-percha but without prefabricated posts, and groups C and F had teeth without gutta-percha or prefabricated posts. Then, the CBCT scans were obtained and examined by three oral and maxillofacial radiologists in order to determine the presence of vertical root fractures. The data were analyzed using IBM SPSS 20.0 (IBM Corp., Armonk, NY, USA). Results: The kappa coefficient was $0.875{\pm}0.049$. Groups A and D showed a sensitivity of 81% and a specificity of 100%; groups E and B, a sensitivity of 94% and a specificity of 100%; and groups C and F, a sensitivity of 88% and a specificity of 100%. Conclusion: The CBCT scans revealed a high accuracy in the diagnosis of vertical root fractures; the accuracy did not decrease in the presence of gutta-percha. The presence of prefabricated posts also had little effect on the accuracy of the system, which was, of course, not statistically significant.

Level of Agreement and Factors Associated With Discrepancies Between Nationwide Medical History Questionnaires and Hospital Claims Data

  • Kim, Yeon-Yong;Park, Jong Heon;Kang, Hee-Jin;Lee, Eun Joo;Ha, Seongjun;Shin, Soon-Ae
    • Journal of Preventive Medicine and Public Health
    • /
    • 제50권5호
    • /
    • pp.294-302
    • /
    • 2017
  • Objectives: The objectives of this study were to investigate the agreement between medical history questionnaire data and claims data and to identify the factors that were associated with discrepancies between these data types. Methods: Data from self-reported questionnaires that assessed an individual's history of hypertension, diabetes mellitus, dyslipidemia, stroke, heart disease, and pulmonary tuberculosis were collected from a general health screening database for 2014. Data for these diseases were collected from a healthcare utilization claims database between 2009 and 2014. Overall agreement, sensitivity, specificity, and kappa values were calculated. Multiple logistic regression analysis was performed to identify factors associated with discrepancies and was adjusted for age, gender, insurance type, insurance contribution, residential area, and comorbidities. Results: Agreement was highest between questionnaire data and claims data based on primary codes up to 1 year before the completion of self-reported questionnaires and was lowest for claims data based on primary and secondary codes up to 5 years before the completion of self-reported questionnaires. When comparing data based on primary codes up to 1 year before the completion of selfreported questionnaires, the overall agreement, sensitivity, specificity, and kappa values ranged from 93.2 to 98.8%, 26.2 to 84.3%, 95.7 to 99.6%, and 0.09 to 0.78, respectively. Agreement was excellent for hypertension and diabetes, fair to good for stroke and heart disease, and poor for pulmonary tuberculosis and dyslipidemia. Women, younger individuals, and employed individuals were most likely to under-report disease. Conclusions: Detailed patient characteristics that had an impact on information bias were identified through the differing levels of agreement.

Comparison of Pre-Operation Diagnosis of Thyroid Cancer with Fine Needle Aspiration and Core-needle Biopsy: a Meta-analysis

  • Li, Lei;Chen, Bao-Ding;Zhu, Hai-Feng;Wu, Shu;Wei, Da;Zhang, Jian-Quan;Yu, Li
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권17호
    • /
    • pp.7187-7193
    • /
    • 2014
  • Background: The aim of this meta-analysis was to compare sensitivities and specificities of fine needle aspiration (FNA) and core needle biopsy (CNB) in the diagnosis of thyroid cancer. Materials and Methods: Articles were screened in Medline, the Cochrane Library, EMBASE and Google Scholar, and subsequently included and excluded based on the patient/problem-intervention-comparison-outcome (PICO) principle. Primary outcome was defined in terms of diagnostic values (sensitivity and specificity) of FNA and CNB for thyroid cancer. Secondary outcome was defined as the accuracy of diagnosis. Compiled FNA and CNB results from the final studies selected as appropriate for meta-analysis were compared with cases for which final pathology diagnoses were available. Statistical analyses were performed for FNA and CNB for all of the selected studies together, and for individual studies using the leave-one-out approach. Results: Article selection and screening yielded five studies for meta-analysis, two of which were prospective and the other three retrospective, for a total of 1,264 patients. Pooled diagnostic sensitivities of FNA and CNB methods were 0.68 and 0.83, respectively, with specificities of 0.93 and 0.94. The areas under the summary ROC curves were 0.905 (${\pm}0.030$) for FNA and 0.745 (${\pm}0.095$) for CNB, with no significant difference between the two. No one study had greater influence than any other on the pooled estimates for diagnostic sensitivity and specificity. Conclusions: FNA and CNB do not differ significantly in sensitivity and specificity for diagnosis of thyroid cancer.