Browse > Article
http://dx.doi.org/10.7314/APJCP.2014.15.17.7187

Comparison of Pre-Operation Diagnosis of Thyroid Cancer with Fine Needle Aspiration and Core-needle Biopsy: a Meta-analysis  

Li, Lei (Zhenjiang Key Laboratory of Molecular Endocrinology, Affiliated Hospital of Jiangsu University)
Chen, Bao-Ding (Zhenjiang Key Laboratory of Molecular Endocrinology, Affiliated Hospital of Jiangsu University)
Zhu, Hai-Feng (Zhenjiang Key Laboratory of Molecular Endocrinology, Affiliated Hospital of Jiangsu University)
Wu, Shu (Zhenjiang Key Laboratory of Molecular Endocrinology, Affiliated Hospital of Jiangsu University)
Wei, Da (Department of General Surgery, Jiangsu Cancer Hospital)
Zhang, Jian-Quan (Department of Ultrasound Diagnosis, Shanghai Changzheng Hospital)
Yu, Li (Zhenjiang Key Laboratory of Molecular Endocrinology, Affiliated Hospital of Jiangsu University)
Publication Information
Asian Pacific Journal of Cancer Prevention / v.15, no.17, 2014 , pp. 7187-7193 More about this Journal
Abstract
Background: The aim of this meta-analysis was to compare sensitivities and specificities of fine needle aspiration (FNA) and core needle biopsy (CNB) in the diagnosis of thyroid cancer. Materials and Methods: Articles were screened in Medline, the Cochrane Library, EMBASE and Google Scholar, and subsequently included and excluded based on the patient/problem-intervention-comparison-outcome (PICO) principle. Primary outcome was defined in terms of diagnostic values (sensitivity and specificity) of FNA and CNB for thyroid cancer. Secondary outcome was defined as the accuracy of diagnosis. Compiled FNA and CNB results from the final studies selected as appropriate for meta-analysis were compared with cases for which final pathology diagnoses were available. Statistical analyses were performed for FNA and CNB for all of the selected studies together, and for individual studies using the leave-one-out approach. Results: Article selection and screening yielded five studies for meta-analysis, two of which were prospective and the other three retrospective, for a total of 1,264 patients. Pooled diagnostic sensitivities of FNA and CNB methods were 0.68 and 0.83, respectively, with specificities of 0.93 and 0.94. The areas under the summary ROC curves were 0.905 (${\pm}0.030$) for FNA and 0.745 (${\pm}0.095$) for CNB, with no significant difference between the two. No one study had greater influence than any other on the pooled estimates for diagnostic sensitivity and specificity. Conclusions: FNA and CNB do not differ significantly in sensitivity and specificity for diagnosis of thyroid cancer.
Keywords
Thyroid; cancer; diagnosis; fine needle aspiration; core-needle biopsy; ultrasound-guided;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Alexander EK, Marqusee E, Orcutt J, et al (2004). Thyroid nodule shape and prediction of malignancy. Thyroid, 14, 953-8.   DOI   ScienceOn
2 Bain G, Bearcroft PW, Berman LH, Grant JW (2000). The use of ultrasound-guided cutting-needle biopsy in paediatric neck masses. Eur Radiol, 10, 512-5.   DOI
3 Mansor M, Okasha H, Esmat S, et al (2012). Role of ultrasound elastography in prediction of malignancy in thyroid nodules. Endocr Res, 37, 67-77.   DOI
4 Morrison SA, Suh H, Hodin RA (2014). The surgical management of thyroid cancer. Rambam Maimonides Med J, 5, 8.
5 Moses LE, Shapiro D, Littenberg B (1993). Combining independent studies of a diagnostic test into a summary roc curve: Data-analytic approaches and some additional considerations. Stat Med, 12, 1293-316.   DOI   ScienceOn
6 Na DG, Kim JH, Sung JY, et al (2012). Core-needle biopsy is more useful than repeat fine-needle aspiration in thyroid nodules read as nondiagnostic or atypia of undetermined significance by the bethesda system for reporting thyroid cytopathology. Thyroid, 22, 468-75.   DOI
7 Nachiappan AC, Metwalli ZA, Hailey BS, et al (2014). The thyroid: Review of imaging features and biopsy techniques with radiologic-pathologic correlation. Radiographics, 34, 276-93.   DOI
8 Park KT, Ahn SH, Mo JH, et al (2011). Role of core needle biopsy and ultrasonographic finding in management of indeterminate thyroid nodules. Head Neck, 33, 160-5.   DOI   ScienceOn
9 Quinn SF, Nelson HA, Demlow TA (1994). Thyroid biopsies: Fine-needle aspiration biopsy versus spring-activated core biopsy needle in 102 patients. J Vasc Interv Radiol, 5, 619-23.   DOI
10 Renshaw AA, Pinnar N (2007). Comparison of thyroid fineneedle aspiration and core needle biopsy. Am J Clin Pathol, 128, 370-4.   DOI
11 Ridder GJ, Technau-Ihling K, Boedeker CC (2005). Ultrasoundguided cutting needle biopsy in the diagnosis of head and neck masses. Laryngoscope, 115, 376-7.   DOI
12 American Cancer Society (2013). Cancer facts & figures 2013. Available at: http://www.cancer.org/acs/groups/content/@epidemiologysurveilance/documents/document/acspc-036845.pdf. Accessed August 21, 2014.
13 Rosman AS, Korsten MA (2007). Application of summary receiver operating characteristics (sroc) analysis to diagnostic clinical testing. Adv Med Sci, 52, 76-82.
14 Screaton NJ, Berman LH, Grant JW (2003). Us-guided coreneedle biopsy of the thyroid gland. Radiology, 226, 827-32.   DOI   ScienceOn
15 Sipos JA, Mazzaferri EL (2010). Thyroid cancer epidemiology and prognostic variables. Clin Oncol (R Coll Radiol), 22, 395-404.   DOI   ScienceOn
16 Sung JY, Na DG, Kim KS, et al (2012). Diagnostic accuracy of fine-needle aspiration versus core-needle biopsy for the diagnosis of thyroid malignancy in a clinical cohort. Eur Radiol, 22, 1564-72.   DOI
17 Sutton AJ, Duval SJ, Tweedie RL, Abrams KR, Jones DR (2000). Empirical assessment of effect of publication bias on metaanalyses. BMJ, 320, 1574-7.   DOI   ScienceOn
18 Tandon S, Shahab R, Benton JI, et al (2008). Fine-needle aspiration cytology in a regional head and neck cancer center: Comparison with a systematic review and meta-analysis. Head Neck, 30, 1246-52.   DOI
19 Vidal-Casariego A, Lopez-Gonzalez L, Jimenez-Perez A, et al (2012). Accuracy of ultrasound elastography in the diagnosis of thyroid cancer in a low-risk population. Exp Clin Endocrinol Diabetes, 120, 635-8.   DOI
20 Wells GA, Shea B, O'Connell D, et al (2000). The newcastleottawa scale (nos) for assessing the quality of nonrandomized studies in meta-analyses. The 3rd symposium on systematic reviews: Beyond the basics. Oxford, England.
21 Cheng P, Chen ED, Zheng HM, He QX, Li Q (2013). Ultrasound score to select subcentimeter-sized thyroid nodules requiring ultrasound-guided fine needle aspiration biopsy in eastern China. Asian Pac J Cancer Prev, 14, 4689-92.   과학기술학회마을   DOI
22 Baloch ZW, Cibas ES, Clark DP, et al (2008). The national cancer institute thyroid fine needle aspiration state of the science conference: A summation. Cytojournal, 5, 6.   DOI
23 Bongiovanni M, Spitale A, Faquin WC, Mazzucchelli L, Baloch ZW (2012). The bethesda system for reporting thyroid cytopathology: A meta-analysis. Acta Cytol, 56, 333-9.   DOI   ScienceOn
24 Bukhari MH, Niazi S, Hanif G, et al (2008). An updated audit of fine needle aspiration cytology procedure of solitary thyroid nodule. Diagn Cytopathol, 36, 104-12.   DOI   ScienceOn
25 Cheung YC, Wan YL, Lui KW, Lee KF (2000). Sonographically guided core-needle biopsy in the diagnosis of superficial lymphadenopathy. J Clin Ultrasound, 28, 283-9.   DOI
26 Cooper DS, Doherty GM, Haugen BR, et al (2009). Revised american thyroid association management guidelines for patients with thyroid nodules and differentiated thyroid cancer. Thyroid, 19, 1167-214.   DOI   ScienceOn
27 Davies L, Welch HG (2006). Increasing incidence of thyroid cancer in the united states, 1973-2002. JAMA, 295, 2164-7.   DOI   ScienceOn
28 Gharib H, Papini E, Paschke R, et al (2010). American association of clinical endocrinologists, associazione medici endocrinologi, and europeanthyroid association medical guidelines for clinical practice for the diagnosis and management of thyroid nodules. Endocr Pract, 16, 1-43.
29 Hahn SY, Shin JH, Han BK, Ko EY, Ko ES (2013). Ultrasonography-guided core needle biopsy for the thyroid nodule: Does the procedure hold any benefit for the diagnosis when fine-needle aspiration cytology analysis shows inconclusive results? Br J Radiol, 86, 20130007.   DOI
30 Ha EJ, Baek JH, Lee JH, et al (2014). Core needle biopsy can minimise the non-diagnostic results and need for diagnostic surgery in patients with calcified thyroid nodules. Eur Radiol, 24, 1403-9.   DOI
31 Hakala T, Kholova I, Sand J, Saaristo R, Kellokumpu-Lehtinen P (2013). A core needle biopsy provides more malignancyspecific results than fine-needle aspiration biopsy in thyroid nodules suspicious for malignancy. J Clin Pathol, 66, 1046-50.   DOI
32 Hanley JA, McNeil BJ (1983). A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology, 148, 839-43.   DOI
33 Harvey JN, Parker D, De P, Shrimali RK, Otter M (2005). Sonographically guided core biopsy in the assessment of thyroid nodules. J Clin Ultrasound, 33, 57-62.   DOI   ScienceOn
34 Karstrup S, Balslev E, Juul N, Eskildsen PC, Baumbach L (2001). Us-guided fine needle aspiration versus coarse needle biopsy of thyroid nodules. Eur J Ultrasound, 13, 1-5.
35 Li N, Du XL, Reitzel LR, Xu L, Sturgis EM (2013). Impact of enhanced detection on the increase in thyroid cancer incidence in the united states: Review of incidence trends by socioeconomic status within the surveillance, epidemiology, and end results registry, 1980-2008. Thyroid, 23, 103-10.   DOI
36 Liu Q, Castelli M, Gattuso P, Prinz RA (1995). Simultaneous fine-needle aspiration and core-needle biopsy of thyroid nodules. Am Surg, 61, 628-32.
37 Novoa E, Gurtler N, Arnoux A, Kraft M (2012). Role of ultrasound-guided core-needle biopsy in the assessment of head and neck lesions: A meta-analysis and systematic review of the literature. Head Neck, 34, 1497-503.   DOI
38 Yassa L, Cibas ES, Benson CB, et al (2007). Long-term assessment of a multidisciplinary approach to thyroid nodule diagnostic evaluation. Cancer, 111, 508-16.   DOI   ScienceOn
39 Yeon JS, Baek JH, Lim HK, et al (2013). Thyroid nodules with initially nondiagnostic cytologic results: The role of coreneedle biopsy. Radiology, 268, 274-80.   DOI
40 Zamora J, Abraira V, Muriel A, Khan K, Coomarasamy A (2006). Meta-disc: A software for meta-analysis of test accuracy data. BMC Med Res Methodol, 6, 31.   DOI
41 Tamsel S, Demirpolat G, Erdogan M, et al (2007). Power doppler us patterns of vascularity and spectral doppler us parameters in predicting malignancy in thyroid nodules. Clin Radiol, 62, 245-51.   DOI   ScienceOn