• Title/Summary/Keyword: semi-closed

Search Result 309, Processing Time 0.025 seconds

The study on performance evaluation of heat resistance and smoke control system using air-curtain system in tunnel (터널용 에어커튼 시스템의 내열 및 제연 성능 평가 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Yang-Kyun;Kim, Hwi-Seong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.4
    • /
    • pp.743-755
    • /
    • 2018
  • Tunnel is a semi-closed structure similar to underground space where the smoke generated from fire fills the space fast while escaping from the space slow. Because of such characteristics, when the fire breaks out by traffic accident, the vehicles are jammed making it difficult for the people to evacuate from the scene as well as for the fire engine to gain access to the scene. For such reasons, tunnels are globally categorized into some disaster classes for differentiated facilities and operation approaches. In Korea, less than a 1 km-long tunnel accounts for 80.0% and such a short tunnel which is categorized into Class III is not required to have smoke control system. In this study, a full-scale fire test was conducted in a bid to apply air curtain system using heat-resistant sirocco fan to a less than 1 km-long tunnel. To that end, heat resistance test to verify the normal operation at $250^{\circ}C$ for 60 minutes was conducted. Consequently, despite of rapid rising-temperature and increasing-carbon dioxide inside the air curtain (direction of fire in tunnel), initial condition was found to have been sustained outside the air curtain (opposite direction of fire in tunnel).

Development of Success Attribution Scale for Body Guard in Korea (한국 경호원의 성공귀인 측정도구 개발)

  • Kim, Sang Jin
    • Convergence Security Journal
    • /
    • v.17 no.2
    • /
    • pp.173-183
    • /
    • 2017
  • This study is for presenting the factors about success attribution that fit the korean security service conditions and developing the actual analysis of measurement tools by investigating the success factors of the security service agents. To this end, conducted a meeting from the fully open questionnaire at first, and then formed the semi-structured questionnaire, finally carried out the survey from the closed questionnaire and analyzed data from SPSS 21.0, AMOS 21.0 and developed the measurements. It was conducted from December, 2014 to June, 2015. This survey was conducted of 170 security guards after the verification of the content validity though the pilot survey and presented the success attribution factors and standards on the basis of the result form this survey. At the first and second analysis process, the success attribution factors of the guards consisted of inner qualities, external qualities, induction factors for inner qualities, and induction factor for external qualities. On analysis of the final data and documents, however, at the third analysis, the success attribution factors of the guards consisted of 'martial arts and physical ability'(4 questions), 'attitudes to work'(3 questions), 'support for the working environment'(3 questions), 'organized business skills'(3 questions), 'attitudes to the duty'(3 questions), and 'coping with crises(2 questions).

Review on the Regional Cooperative Activities for Marine Environmental Conservation in Northeast Asia: with Special Reference to the Northwest Pacific Action Plan (NOWPAP) (동북아시아 해양환경보전을 위한 국제협력활동의 현황과 발전방향: 북서태평양보전실천계획(NOWPAP)을 중심으로)

  • Kang Chang-Gu;Kang Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.6 no.1
    • /
    • pp.30-43
    • /
    • 2003
  • The geography, circulation pattern, and ecology show that the semi-closed seas of Northwest Pacific be managed as one complete system. Ongoing multilateral cooperative efforts relevant to marine environmental protection in the Northwest Pacific area, include the Working Group for the Western Pacific (WESTPAC) established under the auspices of WNESCO's Intergovernmental Oceanographic Commissions, the UNDP/GEF Programme on Prevention and Management of Marine Pollution in East Asian Seas (PEMSEA), the North Pacific Marine Science Organization(PICES), and the United Nations Environment Programme(WNEP)'s Northwest Pacific Action Plan(NOWPAP). The present report firstly describes the current situations on the existing regional cooperative regimes for marine environmental conservation in the Northwest Pacific region, with a special respect to the Northwest Pacific Action Plan(NOWPAP) which was adopted in 1994 by Japan, People's Republic of China, Republic of Korea and Russian Federation. Then, problems of the existing regimes are also discussed, together with the suggestion of the possible solutions, focusing on NOWPAP. Suggestions include: 1) the Northeast Asian countries should understand the importance of legally-binding regional convention, and should build up any legally-binding instrument which can function as a big umbrella for real regional cooperation without prejudice to the rights of the States, 2) At present stage, it will be possible to make a regional convention flexible without prejudice to the sovereign right of the States or territorial issues; 3) taking into account that the region often faces many generic political problems that often inhibit the effective collective actions on environmental issues, the leadership from UNEP or other international organizations is required; 4) strong institutional and financial framework should be made, and 5) multilateral efforts to respond to the new marine environmental threats should be taken at the regional level in order to protect the coastal and marine environments in the Northwest Pacific.

  • PDF

A Study on the Pollution of Bisphenol A in Surface Sediment around Gwangyang Bay (광양만 주변해역의 표층퇴적물 중 Bisphenol A의 오염에 관한 연구)

  • Cho Hyeon-Seo;Kim Yong-Ok;Shin Tai-Sun;Horiguchi Toshihiro
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.2
    • /
    • pp.104-110
    • /
    • 2004
  • This study was carried out to survey the pollution of bisphenol A(BPA) and total organic carbon(TOC) in surface sediments around Gwangyang bay. BPA is suspected chemicals as endocrine disruption. Gwangyang bay Is located on the mid south coast of Korea. It is a semi-closed bay which Yeosu petrochemical industrial complex, POSCO(Pohang Steel Company) and Gwangyang container harbor are located. The surface sediments were collected at 15 stations with gravity corer at October, 1999, February, May and August, 2000. Also, the stream and intertidal sediment were collected at 5 sites at August, 2000. Concentrations of BPA in surface sediments were in the range of 0.46 to 24.59 ng/g dry wt.. Seasonal range(mean value) of BPA are 0.59 to 9.00(1.88) ng/g dry wt. at October, 0.99 to 2.97(1.57) ng/g dry wt. at February, 0.46 to 24.59(2.53)ng/g dry wt. at May and 0.54 to 2.46 (1.29)ng/g dry wt. at August. BPA was seasonally fluctuated, and the highest mean value and range were detected at May, 2000. BPA was highly distributed in the inner part of Kwangyang bay than Yosu sound. Concentrations of BPA in stream and intertidal sediments showed the highest value in downstream near Yochon petrochemical industrial complex and Yondung stream. It suggests that the source of BPA are industrial wastewater and municipal sewage. TOC in surface sediments were in the range of 0.09∼1.22%. There was no any correlation between the BPA and TOC.

  • PDF

Apparent Densification Rate and Initial Permeability of NiCuZn Ferrite Depended on Relative Packing Density (NiCuZn Ferrite의 겉보기 고화속도와 초기투자율의 충진율 의존성에 관한 연구)

  • 류병환;이정민;고재천
    • Resources Recycling
    • /
    • v.7 no.4
    • /
    • pp.27-34
    • /
    • 1998
  • In this research, the processing control of NiCuZn Ferrite (NCZF) had been studied. NiCuZn Ferrite, which calcined at $700^{\circ}C$ for 3 bours, was ball milled for about 60 hours to ill김ke a size of $0.5\mu\;extrm{m}$ followed by granulation using spray dryer Apparent densincatioo rate and initial permeability of NiCuZn Ferrite with an initial packing density had been investigated as f follows. 1.The relative packing density of NCZF green body increas$\xi$d in the range of 48.6-56.8% with an increased forming pressure of 20-170 MPa. 2. The higher the relative pac퍼ng density of NCZF and the sintering temperature are, the higher the initial densification rate. The increased bulk rlcnsity of NCZF was attributed to the densification rate with decreased open pore and increased closed pore as the relative packing density, sintering temperature, and sinteriog tim$\xi$ increased. 3. The initial P permeability of NCZF with constant composition is logarithmically proportional to the bulk density of NCZF sintered at $875~925^{\circ}C$ for 0-5h, and strongly depended on the relative packing density of NCZF green body. The empirical equation is as f follows; log $\mu$i=$G1{\times}BD$+$G2{\times}RPD$+b(0);where, G1, G2; gradient, B.D: bulk density, RPD; relative packing density, b(0); intercept.

  • PDF

CFD analysis of the effect of hydrogen jet flame in road tunnel (도로 터널 내 수소 제트 화염에 대한 CFD 해석 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Hwiseong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.629-636
    • /
    • 2022
  • Domestic eco-friendly vehicles currently account for 5.8% of the total registered vehicles in Korea. Hydrogen vehicles, one of the representative eco-friendly vehicles, have grown rapidly as they have been expanded to the market based on the government's policy to boost the hydrogen industry. Therefore, it is time to expand the safety review of hydrogen vehicles in various directions according to the increase in supply. In this study, the effect of internal heat damage was analyzed when a jet flame was generated by a hydrogen car in a road tunnel. It was simulated using Fluent, and the amount of jet flame injection was selected in consideration of the hydrogen tank capacity of commercial hydrogen vehicles for road tunnels. In addition, the study was conducted with the direction of the jet flame and the nozzle distance from the tunnel wall as variables. From the results, when the jet flame erupted in the road tunnel, high radiant heat emission of more than 20 kW/m2 was generated in most areas within ±5 m in the longitudinal direction based on the vehicle (spray nozzle) and 5 to 7 m in the lateral direction based on the adjacent tunnel wall.

A numerical analysis study on the flammable volume by leakage of hydrogen fuel vehicles in parking lot (지하주차장 내 수소연료차의 수소 방출시 가연체적에 관한 수치해석적 연구)

  • Lee, Ho-Hyung;Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.439-449
    • /
    • 2021
  • The recent reduction in greenhouse gases, interest in environmental pollution such as low-carbon emission policies is increasing. Accordingly, the penetration rate of eco-friendly vehicles, including hydrogen battery vehicles capable of reducing carbon emission, is increasing, and thus it is required for disaster prevention and safety-related measures. In this study, the degree of risk for the concentration distribution of hydrogen when leaking hydrogen fuel vehicles according to ventilation conditions was analyzed through numerical analysis, limited to places in parking lots. As a result, when only one hydrogen tank was released, the combustible volume ratio of hydrogen in the underground parking lot was up to 8.6%, and as ventilation continued, the volume ratio of combustible hydrogen decreased to less than 1% after 150 seconds, indicating that mechanical ventilation is essential. In the case of simultaneous release or stage release of three hydrogen tanks, the final combustible volume ratio of hydrogen is similar, but the increase in the combustible volume ratio of hydrogen in the early stage of release is low, and further research is expected.

A Case Study on Vocal Aerobic Treatment Voice Therapy Development and Application for Classical Singers (성악가를 위한 VAT 음성치료 개발 및 적용 사례연구)

  • Yoo, Jae-Yeon;Lee, Ha-Na
    • 재활복지
    • /
    • v.22 no.1
    • /
    • pp.157-168
    • /
    • 2018
  • The purpose of this study is to investigate the impact of semi-closed vocal training-based Vocal Aerobic Treatment on the voice improvement of soprano. Study subject was one soprano who appealed to the suffering of her voice problem due to vocal cord nodule. A study method of conducting pre/post acoustic evaluation and subjective voice evaluation to compare the measures was used; Vocal Aerobic Treatment was carried out twice a week for a total of 32 session. In the acoustic evaluation, MDVP (multi-dimensional voice program) and VRP (voice range profile) were used to evaluate the pitch, voice quality, and voice range; in the subjective voice evaluation, SVHI (singing voice handicap index) was used to assess voice satisfaction. As a result of the pitch evaluation, the soprano maintained a proper Fo. As a result of the voice quality evaluation, the jitter, shimmer, and the noise harmonic ratio numbers decreased compared to the numbers shown before the treatment. As a result of the voice range evaluation, the scope of the range was broadened, with the number of semitone increasing from 30 to 35. As for the subjective voice evaluation, the result of the total score obtained after the survey report divided by the number of questions showed a decrease from 3.6 to 0.6. The soprano herself reported of having a minor extent of a voice problem. The summary of the above results reflects that Vocal Aerobic Treatment is useful in the voice improvement of vocalists However, as this study is case research regarding the Vocal Aerobic Treatment effect on one soprano, further research on the treatment effect covering many other vocalists is necessary. Also, there is a need for follow-up studies regarding voice management and voice treatment program on not only the vocalists but also the voice users in many other professions.

The attribution of the security guard failure and grope for efficient operational measures of security guard through the analysis of failures : propensity eduction of failure-factors of security guard and patterns of danger and injury (경호실패귀인과 실패사례 분석을 통한 효율적인 경호운용방안 모색 : 경호환경의 실패요인과 위해패턴 성향 도출)

  • Kim, Sang Jin
    • Convergence Security Journal
    • /
    • v.18 no.1
    • /
    • pp.143-155
    • /
    • 2018
  • The purpose of this study is to extract the failure attributions to identify the failure factors of the security guards and to derive the risk factor factors through failure cases analysis. Failure attributions were prepared by using semi-structured questionnaires(17) and closed questionnaires(179) starting from the fully open questionnaires(8), and processed through SPSS 21.0 and AMOS 21.O statistical packages. As a result of summarizing the causal relationship between the failure attribution and the failure case (patrol failure pattern factor), In Park Jung-Hee's assassination, lack of experience(2), negative mind(1), lack of work ability(1), lack of experience(2), organizational non-system activeness(2), lack of awareness of mission(1) Failure(2), lack of consciousness(2), and 14 failure patterns were found. Aung-San National Cemetery explosion occurred in eight failure patterns including insecurity(1), negative mind(1), lack of work skills(2), lack of experience(2), individualism(1), There were eight failure patterns in the case of Mr. Yook Young-Su 's sniping, including insincerity(2), negative mind (1), lack of experience(2), lack of awareness of mission(2) and failure to share work(1).

  • PDF

Seasoning of Commercial Wood Using Solar Energy (태양에너지를 이용한 유용목재의 건조)

  • Jung, Hee-Suk;Lee, Hyoung-Woo;Lee, Nam-Ho;Lee, Sang-Bong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.10-39
    • /
    • 1988
  • This study investigated the temperatures and relative humidities in the semi-greenhouse type solar dryer with a black rock-bed heat storage and without heat storage and outdoor temperature and relative humidity at 9 a.m. and 2 p.m.. A comparison was made of the drying rates, final moisture contents, moisture content distributions, casehardening stresses, drying defects, volumetric shrinkage of dried lumber for solar- and air-drying from the green condition of mixtures of Douglas-fir, lauan, taun, oak and sycamore 25mm- and 50 mm-thick lumber during the same period for four seasons, and heat efficiencies for solar dryer with and without the heat storage for saving of heat energy and the cost of lumber drying using the solar energy. The results from this study were summarized as follows: I. The mean weekly temperatures in the solar dryers were 3 to $6^{\circ}C$ at 9 a.m. and 9 to $13^{\circ}C$ at 2 p.m. higher than mean outdoor temperature during all the drying period. 2. The mean weekly relative humidities in the solar dryers were about 1 to 19% at 9 a.m. higher than the outdoor relative humidity. and the difference between indoor and outdoor relative humidity in the morning was greater than in the afternoon. 3. The temperatures and relative humidities in the solar dryer with and without the heat storage were nearly same. 4. The overall solar insolation during the spring months was highest and then was greater in the order of summer, atumm, and winter month. S. The initial rate of solar drying was more rapid than that of air drying. As moisture content decreased, solar drying rate became more rapid than that of air drying. The rates of solar drying with and without heat storage were nearly same. The drying rate of Douglas-fir was fastest and then faster in the order of sycamore, lauan, taun and oak. and the faster drying rate of species, the smaller differences of drying rates between thicknesses of lumber. The drying rates were fastest in the summer and slowest in the winter. The rates of solar drying during the spring were more slowly in the early stage and faster in the later stage than those during the autumn. 6. The final moisture contents were above 15% for 25mm-thick air dried and about 10% for solar dried lumber, but the mean final MCs for 50mm-thick lumber were much higher than those of thin lumber. The differences of final MC between upper and lower course of pile for solar drying were greater than those of pile for air drying. The differences of moisture content between the shell and the core of air dried lumbers were greater than those of solar dried lumber, smallest in the drying during summer and greatest in the drying during winter among seasons. 7. Casehardening stresses of 25mm- and 50mm-thick dried lumber were slight, casehardening stress of solar dried lumber was severer than that of air dried lumber and was similar between solar dried lumber with and without heat storage, Casehardening stresses of lumber dried during spring were slightest and then slighter in the order of summer, autumn, and winter. Casehardening stresses of Douglas -fir, sycamore and lauan were slight, comparing with those of taun and oak. 8. Maximum initial checks of 25mm-thick lumber occurred above and below fiber saturation point and those of 50mm-thick lumber occurred in the higher moisture content than thin lumber. As the moisture content decreased, most of checks were closed and didn't show distinct difference of the degree of checks among drying methods. The degree of checks were very slight in case of Douglas-fir and lauan, and severe in case of taun and oak. The degree of checks for 50mm-thick lumber were severer than those for 25mm-thick lumber. 9. The degree of warpage showed severe in case of oak and sycamore lumber, but no warping was found in case of Douglas-fir, lauan and taun. 10. The volumetric shrinkages of taun and oak were large and medium in case of Douglas-fir, lauan and sycamore. 11. Heat efficiencies of solar dryer with heat storage were 6.9% during spring, 7.7% during summer, 12.1% during autumn and 4.1% during winter season. Heat efficiency of solar dryer with heat storage was slightly greater than that of without heat storage. As moisture content of lumber decreased, heat efficiency decreased.

  • PDF