• Title/Summary/Keyword: self-imaging

Search Result 206, Processing Time 0.032 seconds

Effects of Practical Training Using 3D Printed Structure-Based Blind Boxes on Multi-Dimensional Radiographic Image Interpretation Ability (3D 프린팅 구조물 기반 블라인드박스를 이용한 실습교육이 다차원 방사선영상해독력에 미치는 효과)

  • Youl-Hun, Seoung
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.131-139
    • /
    • 2023
  • In this study, we are purposed to find the educational effect of practical training using a 3D printed structure-based blind box on multidimensional radiographic image interpretation. The subjects were 83 (male: 49, female: 34) 2nd year radiological science students who participated in the digital medical imaging practice that was conducted for 3 years from 2020 to 2022. The learning method used 3D printing technology to print out the inside structure of the blind box designed by itself. After taking X-rays 3 times (x, y, z axis), the structure images in the blind box were analyzed for each small group. We made the 3D structure that was self-made with clay based on our 2D radiographic images. After taking X-rays of the 3D structure, it was compared whether it matches the structural image of the blind box. The educational effect for the practical training surveyed class faithfulness, radiographic image interpretation ability (attenuation concept, contrast concept, windowing concept, 3-dimensional reading ability), class satisfaction (interest, external recommendation, immersion) on a 5-point Likert scale as an anonymous student self-writing method. As a result, all evaluation items had high positive effects without significant differences between males and females. Practical education using blind boxes is a meaningful example of radiology education technology using 3D printing technology, and it is expected to be used as content to improve students' problem-solving skills and increase satisfaction with major subjects.

Convergence Comparison of Metal Artifact Reduction Rate for Pacemaker Insertion of CT Imaging Phantoms in the Raw Data with MAR Algorithm (심박조율기 삽입 팬텀의 CT영상 원시데이터에 금속인공물감소 알고리즘 적용 시 금속인공물 감소율의 융합적 비교)

  • Kim, Hyeon-ju;Yoon, Joon
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2017
  • In the analyzed cardiac CT algorithm applied when comparing the MAR self-made metal artifact reduction in pacemaker inserted phantom degree. Result of comparing the energy value by CT showed a decrease in the CT value in the case of BKG 40 KeV in WSA maximum decreased to 663.2% in the case of 140 KeV BHA were increased a maximum of 56.2%. In addition, the maximum was decreased by approximately 145% based on a 70 KeV artifacts in CT value comparison by type WSA, BHA was to increase up to approximately 46.38%. MAR Algorithm is believed to provide a more quality cardiac CT image if the energy changes, or have the effect that by type and irrespective of reduced metal artifacts occurrence of artifacts applied to the pacemaker when tracking a heart CT scan after inserting MAR algorithm.

In situ UHV TEM studies on nanobubbles in graphene liquid cells

  • Shin, Dongha;Park, Jong Bo;Kim, Yong-Jin;Kim, Sang Jin;Kang, Jin Hyoun;Lee, Bora;Cho, Sung-Pyo;Novoselov, Konstantin S.;Hong, Byung Hee
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.102-102
    • /
    • 2016
  • Water, which is most abundant in Earth surface and very closely related to all forms of living organisms, has a simple molecular structure but exhibits very unique physical and chemical properties. Even though tremendous effort has been paid to understand this nature's core substance, there amazingly still lefts much room for scientist to explore its novel behaviors. Especially, as the scale goes down to nano-regime, water shows extraordinary properties that are not observable in bulk state. One of such interesting features is the formation of nanoscale bubbles showing unusual long-term stability. Nanobubbles can be spontaneously formed in water on hydrophobic surface or by decompression of gas-saturated liquid. In addition, the nanobubbles can be generated during electrochemical reaction at normal hydrogen electrode (NHE), which possibly distorts the standard reduction potential at NHE as the surface nanobubble screens the reaction with electrolyte solution. However, the real-time evolution of these nanobubbles has been hardly studied owing to the lack of proper imaging tools in liquid phase at nanoscale. Here we demonstrate, for the first time, that the behaviors of nanobubbles can be visualized by in situ transmission electron microscope (TEM), utilizing graphene as liquid cell membrane. The results indicate that there is a critical radius that determines the long-term stability of nanobubbles. In addition, we find two different pathways of nanobubble growth: i) Ostwald ripening of large and small nanobubbles and ii) coalescence of similar-sized nanobubbles. We also observe that the nucleation and growth of nanoparticles and the self-assembly of biomolecules are catalyzed at the nanobubble interface. Our finding is expected to provide a deeper insight to understand unusual chemical, biological and environmental phenomena where nanoscale gas-state is involved.

  • PDF

Brazilian young dental practitioners' use and acceptance of digital radiographic examinations

  • Rovaris, Karla;de Faria Vasconcelos, Karla;do Nascimento, Eduarda Helena Leandro;Oliveira, Matheus Lima;Freitas, Deborah Queiroz;Haiter-Neto, Francisco
    • Imaging Science in Dentistry
    • /
    • v.46 no.4
    • /
    • pp.239-244
    • /
    • 2016
  • Purpose: The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that have occurred over the past 5 years. Materials and Methods: Dental practitioners enrolled in extension courses at the Piracicaba Dental School, University of Campinas, Brazil, responded to a self­administered questionnaire in the years 2011 and 2015. They were asked about sociodemographic factors and their knowledge and use of digital radiographic examinations. Descriptive analysis was performed, as well as the chi-square and Fisher exact tests, with a significance level of 5% (${\alpha}=0.05$). results: A total of 181 participants responded to the questionnaire in the years 2011 and 2015. Most of the respondents worked in private practice, had graduated within the last 5 years, and were between 20 and 30 years old. In 2011, 55.6% of respondents reported having ever used digital radiographic examinations, while in 2015 this number increased significantly to 85.4% (p<.0001), out of which 71.4% preferred it to conventional images. Moreover, 21.4% of respondents reported having used digital radiographic examinations for more than 3 years. A significant increase in use of intraoral digital radiography (p = 0.0316) was observed in 2015. In both years, image quality and high cost were indicated, respectively, as the main advantage and disadvantage of digital radiographic examinations. conclusion: This study showed that digital radiology has become more common in Brazil over the past 5 years. Most of the Brazilian dental practitioners evaluated in 2015 used digital radiographic examinations.

Radiographic Classification and its Clinical Features for Metaphyseal Cortical Defect of the Distal Femur (대퇴골 원위부 골간단의 피질골 결손에 대한 방사선학적 분류 및 그에 따른 임상적 경과관찰)

  • Park, Il-Hyung;Oh, Chang-Wug;Min, Woo-Kie
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.5 no.1
    • /
    • pp.17-22
    • /
    • 1999
  • Over 60 cases were enlisted, but only 31 cases among 24 patients were eligible with a minimum follow-up of 1 year and complete medical documents with imaging data. There were 18 boys and 6 girls, and 7 patients had bilateral lesions. The age of the patients ranged from 2 to 20 years(mean:10.5 years). At their first visit, most lesions had a highly characteristic location and radiographic appearance of radiolucent lesion(s) ranging from 1 to 3cm, except for one case of 5.5 cm in the posteromedial comer of distal femoral metaphysis. The margins were generally well-defined, although some were ill-defined. After reviewing our cases from the viewpoint of clinical course and radiographic patterns, we divided these lesions into two types. Type I is the osteolytic lesion excavated into the posteromedial aspect of the distal femur without cortical defect; and type II is the buldged out lesion of the femur with cortical irregularity into the surrounding soft tissues. Both types have distinctive clinical courses. Type I lesions were easy to make a definite diagnosis with plain radiographs alone, but in type II, it was sometimes very difficult to differentiate it from malignant tumors or chronic localized osteomyelitis. For this lesion, Gd-enhanced MRI was the most effective method for differential diagnosis. In this study, biopsy was not necessary to confirm the diagnosis. Clinical symptoms of type I were very minor or even absent. Many of them were accidentally found after minor trauma around the knee joint. Clinical symptoms disappeared far earlier than radiographical lesions. No treatment such as restriction of activity or drugs was necessary. For type II, the clinical symptoms were more accentuated and lasted longer, and it was necessary to restrict the activity for a certain period in many cases. However, all were self-limited.

  • PDF

Prevalence of considering revision rhinoplasty in Saudi patients and its associated factors

  • Alsubeeh, Najlaa Abdulrahman;AlSaqr, Mayar Abdulsalam;Alkarzae, Mohammed;Aldosari, Badi
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.59.1-59.10
    • /
    • 2019
  • Background: Primary rhinoplasty outcomes may not meet individual expectations. Consequently, reoperation may be advocated to improve results. This study examines the prevalence of individuals considering revision rhinoplasty, while identifying the main cosmetic and functional complaints and factors associated. Methodology: This is a cross-sectional study conducted in Saudi Arabia using a self-reported online questionnaire distributed through social media channels. The sample included 1370 participants who were all Saudi nationals over the age of 16 who had undergone primary rhinoplasty at least 1 year prior. Results: The prevalence of individuals considering revision rhinoplasty was 44.7%. The primary reason for considering it was the desire for further esthetic improvement in an already acceptable result (50.16%). The most common cosmetic complaints subjectively reported were poorly defined nasal tip (32.35%). The most prevalent nasal function symptom was nasal obstruction (56.9%). Significant factors associated with considering revision rhinoplasty included the physician not understanding the patient's complaints, short consultation time, low monthly income, inadequate information about the expected results, not using computer imaging to predict outcomes, lack of rapport with the surgeon, and inadequate information about the risks and complications. Conclusions: A thorough understanding of patient concerns and expectations, as well as thoughtful consideration of risk factors, may help surgeons achieve more successful outcomes and potentially reduce the incidence of revision rhinoplasties. Level of evidence: III.

A novel ceramic GEM used for neutron detection

  • Zhou, Jianrong;Zhou, Xiaojuan;Zhou, Jianjin;Jiang, Xingfen;Yang, Jianqing;Zhu, Lin;Yang, Wenqin;Yang, Tao;Xu, Hong;Xia, Yuanguang;Yang, Gui-an;Xie, Yuguang;Huang, Chaoqiang;Hu, Bitao;Sun, Zhijia;Chen, Yuanbo
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1277-1281
    • /
    • 2020
  • A novel ceramic Gas Electron Multiplier (GEM) has been developed to meet the demand of high counting rate for the neutron detection which is an alternative to 3He-based detector at China Spallation Neutron Source (CSNS). An experiment was performed to measure the neutron transmittance of ceramic-GEM and FR4-GEM at the small angle neutron scattering (SANS) instrument. The result showed the ceramic-GEM has higher transmittance and less self-scattering especially for cold neutrons. One single ceramic GEM could give a gain of 102-104 in the mixture gas of Ar and CO2 (90%:10%) and its energy resolution was about 27.7% by using 55Fe X ray of 5.9 keV. A prototype has been developed in order to investigate the performances of the ceramic GEM-based neutron detector. Several neutron beam tests, including detection efficiency, spatial resolution, two-dimensional imaging, and wavelength spectrum, were carried out at CSNS and China Mianyang Research Reactor (CMRR). The results show that the ceramic GEM-based neutron detector is a good candidate to measure the high intensity neutrons.

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

Evaluation of the Utility of Self Produced MRI Radiofrequency Shielding Material (자체 제작한 자기공명영상 고주파 차폐체의 유용성 평가)

  • Lee, Jin-Hoe;Lee, Bo-Woo
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.89-94
    • /
    • 2020
  • This paper proposes a better shielding method to over sampling technique. The new method uses aluminum foil for RF shielding. As a result of the phantom test, when the over-sampling technique was applied, the aliasing artifact was reduced by about 94% compared to before the application, and the case where the aluminum shielding band was applied was also reduced by about 92% compared to before application. In addition, the scan time also increased by more than 3 times in the case of the over-sampling technique, while it was found that there was no change from before the application of the aluminum shielding band Therefore, it was confirmed that the shielding band using aluminum foil can effectively remove aliasing artifacts without increasing the scan time..

Altered Functional Disconnectivity in Internet Addicts with Resting-State Functional Magnetic Resonance Imaging

  • Seok, Ji-Woo;Sohn, Jin-Hun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.377-386
    • /
    • 2014
  • Objective: In this study, we used resting-state fMRI data to map differences in functional connectivity between a comprehensive set of 8 distinct cortical and subcortical brain regions in healthy controls and Internet addicts. We also investigated the relationship between resting state connectivity strength and the level of psychopathology (ex. score of internet addiction scale and score of Barratt impulsiveness scale). Background: There is a lot of evidence of relationship between Internet addiction and impaired inhibitory control. Clinical evidence suggests that Internet addicts have a high level of impulsivity as measured by behavioral task of response inhibition and a self report questionnaire. Method: 15 Internet addicts and 15 demographically similar non-addicts participated in the current resting-state fMRI experiment. For the connectivity analysis, regions of interests (ROIs) were defined based on the previous studies of addictions. Functional connectivity assessment for each subject was obtained by correlating time-series across the ROIs, resulting in $8{\times}8$ matrixs for each subject. Within-group, functional connectivity patterns were observed by entering the z maps of the ROIs of each subject into second-level one sample t test. Two sample t test was also performed to examine between group differences. Results: Between group, the analysis revealed that the connectivity in between the orbito frontal cortex and inferior parietal cortex, between orbito frontal cortex and putamen, between the orbito frontal cortex and anterior cingulate cortex, between the insula and anterior cingulate cortex, and between amydgala and insula was significantly stronger in control group than in the Internet addicts, while the connectivity in between the orbito frontal cortex and insula showed stronger negative correlation in the Internet addicts relative to control group (p < 0.001, uncorrected). No significant relationship between functional connectivity strength and current degree of Internet addiction and degree of impulsitivy was seen. Conclusion: This study found that Internet addicts had declined connectivity strength in the orbitofrontal cortex (OFC) and other regions (e.g., ACC, IPC, and insula) during resting-state. It may reflect deficits in the OFC function to process information from different area in the corticostriatal reward network. Application: The results might help to develop theoretical modeling of Internet addiction for Internet addiction discrimination.