• Title/Summary/Keyword: self-expandable stent

Search Result 61, Processing Time 0.032 seconds

Serious Complications after Self-expandable Metallic Stent Insertion in a Patient with Malignant Lymphoma

  • Cho, Sung Bae;Cha, Seon Ah;Choi, Joon Young;Lee, Jong Min;Kang, Hyeon Hui;Moon, Hwa Sik;Kim, Sei Won;Yeo, Chang Dong;Lee, Sang Haak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.1
    • /
    • pp.31-35
    • /
    • 2015
  • An 18-year-old woman was evaluated for a chronic productive cough and dyspnea. She was subsequently diagnosed with mediastinal non-Hodgkin lymphoma (NHL). A covered self-expandable metallic stent (SEMS) was implanted to relieve narrowing in for both main bronchi. The NHL went into complete remission after six chemotherapy cycles, but atelectasis developed in the left lower lobe 18 months after SEMS insertion. The left main bronchus was completely occluded by granulation tissue. However, the right main bronchus and intermedius bronchus were patent. Granulation tissue was observed adjacent to the SEMS. The granulation tissue and the SEMS were excised, and a silicone stent was successfully implanted using a rigid bronchoscope. SEMS is advantageous owing to its easy implantation, but there are considerable potential complications such as severe reactive granulation, stent rupture, and ventilation failure in serious cases. Therefore, SEMS should be avoided whenever possible in patients with benign airway disease. This case highlights that SEMS implantation should be avoided even in malignant airway obstruction cases if the underlying malignancy is curable.

Endoscopic ultrasound-guided gastrojejunostomy with a direct technique without previous intestinal filling using a tubular fully covered self-expandable metallic stent

  • Hakan Senturk;Ibrahim Hakki Koker;Koray Kochan;Sercan Kiremitci;Gulseren Seven;Ali Tuzun Ince
    • Clinical Endoscopy
    • /
    • v.57 no.2
    • /
    • pp.209-216
    • /
    • 2024
  • Background/Aims: Endoscopic ultrasonography-guided gastrojejunostomy is a minimally invasive method for the management of gastric outlet obstruction. Conventionally, a lumen-apposing metal stent (LAMS) is used to create an anastomosis. However, LAMS is expensive and not widely available. In this report, we described a tubular fully covered self-expandable metallic stent (T-FCSEMS) for this purpose. Methods: Twenty-one patients (15 men [71.4%]; median age, 66 years; range, 40-87 years) were included in this study. A total of 19 malignant (12 pancreatic, 6 gastric, and 1 metastatic rectal cancer) and 2 benign cases were observed. The proximal jejunum was punctured with a 19 G needle. The stomach and jejunum walls were dilated with a 6 F cystotome, and a 20×80 mm polytetrafluoroethylene T-FCSEMS (Hilzo) was deployed. Oral feeding was initiated after 12 to 18 hours and solid foods after 48 hours. Results: The median procedure time was 33 minutes (range, 23-55 minutes). After two weeks, 19 patients tolerated oral feeding. In patients with malignancy, the median survival time was 118 days (range, 41-194 days). No serious complications or deaths occurred. All patients with malignancy tolerated oral food intake until they expired. Conclusions: T-FCSEMS is safe and effective. This stent should be considered as an alternative to LAMS for gastric outlet obstruction.

Practical Experiences of Unsuccessful Hemostasis with Covered Self-Expandable Metal Stent Placement for Post-Endoscopic Sphincterotomy Bleeding

  • Michihiro Yoshida;Tadahisa Inoue;Itaru Naitoh;Kazuki Hayashi;Yasuki Hori;Makoto Natsume;Naoki Atsuta;Hiromi Kataoka
    • Clinical Endoscopy
    • /
    • v.55 no.1
    • /
    • pp.150-155
    • /
    • 2022
  • We reviewed 7 patients with unsuccessful endoscopic hemostasis using covered self-expandable metal stent (CSEMS) placement for post-endoscopic sphincterotomy (ES) bleeding. ES with a medium incision was performed in 6 and with a large incision in 1 patient. All but 1 of them (86%) showed delayed bleeding, warranting second endoscopic therapies followed by CSEMS placement 1-5 days after the initial ES. Subsequent CSEMS placement did not achieve complete hemostasis in any of the patients. Lateral-side incision lines (3 or 9 o'clock) had more frequent bleeding points (71%) than oral-side incision lines (11-12 o'clock; 29%). Additional endoscopic hemostatic procedures with hemostatic forceps, hypertonic saline epinephrine, or hemoclip achieved excellent hemostasis, resulting in complete hemostasis in all patients. These experiences provide an alert: CSEMS placement is not an ultimate treatment for post-ES bleeding, despite its effectiveness. The lateral-side of the incision line, as well as the oral-most side, should be carefully examined for bleeding points, even after the CSEMS placement.

Temporary Semi-Jailing Technique for Coil Embolization of Wide-Neck Aneurysm with Small Caliber Parent Artery Following Incomplete Clipping

  • Byun, Jun Soo;Kim, Jae Kyun;Lee, Hwa Yeon;Hwang, Sung Nam
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.4
    • /
    • pp.241-244
    • /
    • 2013
  • The authors describe the use of a self-expandable stent in a temporary deployment for treatment of a very wide-neck A1 segment of anterior cerebral artery (ACA) aneurysm following incomplete clipping. A 39-year-old hypertensive man presenting with seizure-like movement underwent computed tomography, which showed acute subarachnoid hemorrhage and an A1 segment of ACA aneurysm with superior and inferior projection. He underwent surgical clipping of the aneurysm, but superior and posterior portion of wide-neck aneurysm remained. We decided to treat the remnant aneurysm using an endovascular modality. After selection of the aneurysm, coil packing was performed assisted by the temporary semi-jailing technique. The Enterprise stent (Cordis Neurovascular, Miami, FL, USA) was deployed and recaptured repeatedly for angiography to ensure safety of the small caliber parent artery. Successful semi-deployment and recapture of the stent allowed subtotal coil occlusion of the aneurysm with good anatomic and clinical results. No complications were encountered. The stent could be recaptured up to the point where the proximal end of the stent marker was aligned with distal marker band of the microcatheter, approximately 70% of the stent length. The temporary semi-jailing technique is feasible for wide-neck aneurysm with small caliber parent artery.

Y-Stenting Endovascular Treatment for Ruptured Intracranial Aneurysms : A Single-Institution Experience in Korea

  • Lee, Woo Joo;Cho, Chun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.3
    • /
    • pp.187-192
    • /
    • 2012
  • Objective : Stent-assisted coiling on intracranial aneurysm has been considered as an effective technique and has made the complex aneurysms amenable to coiling. To achieve reconstruction of intracranial vessels with preservation of parent artery the use of stents has the greatest potential for assisted coiling. We report the results of our experiences in ruptured wide-necked intracranial aneurysms using Y-stent coiling. Methods : From October 2003 to October 2011, 12 patients (3 men, 9 women; mean age, 62.6) harboring 12 complex ruptured aneurysms (3 middle cerebral artery, 9 basilar tip) were treated by Y-stent coiling by using self-expandable intracranial stents. Procedural complications, clinical outcome, and initial and midterm angiographic results were evaluated. The definition of broad-necked aneurysm is neck diameter over than 4 mm or an aneurysm with a neck diameter smaller than 4 mm in which the dome/neck ratio was less than 2. Results : In all patients, the aneurysm was successfully occluded with no apparent procedure-related complication. There was no evidence of thromboembolic complication, arterial dissection and spasm during procedure. Follow-up studies showed stable and complete occlusion of the aneurysm in all patients with no neurologic deficits. Conclusion : The present study did show that the Y-stent coiling seemed to facilitate endovascular treatment of ruptured wide-necked intracranial aneurysms. More clinical data with longer follow-up are needed to establish the role of Y-stent coiling in ruptured aneurysms.

Celiac Artery Dissection after Abdominal Blunt Trauma (복부 둔상 후 발견된 복강동맥 박리 1례)

  • Suh, Yun Suhk;Kim, Seong Chun;Ra, Hwan Do;Han, Ho-Seong
    • Journal of Trauma and Injury
    • /
    • v.19 no.2
    • /
    • pp.196-200
    • /
    • 2006
  • We report a case of celiac artery dissection after abdominal blunt trauma. A 29-year-old man visited the emergency room for acute left periumbilical pain after abdominal blunt trauma from his child. Computed tomography showed a wedge-shaped splenic infarction with splenic artery thrombus. He was hospitalized for careful observation, and after two days, follow-up computed tomographic angiography showed a progressed celiac artery dissection that involved common hepatic artery and an increased extent of splenic infarction. He underwent conventional angiography, and a self-expandable stent was placed between the celiac axis and the common hepatic artery. After two days, follow-up computed tomographic angiography showed good hepatic arterial blood flow via the stent and no progression of splenic infarction. After ten days, he was discharged without complications.

Modified 'Y-Configured Stents with Waffle Cone Technique' for Broad Neck Basilar Top Aneurysm

  • Cho, Jun-Sung;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.6
    • /
    • pp.517-519
    • /
    • 2011
  • Stent assisted coiling on intracranial broad neck aneurysm has been considered as an effective technique and has made the complex aneurysms amenable to coiling. However, stent navigation and application themselves often have the problems especially when the parent vessel angle (entrance between afferent and efferent vessel) is over 90 degrees. We report here a case of a ruptured broad neck basilar top aneurysm that was successfully coiled using two self-expandable stents (Enterprise and Neuroform) placed in a fashion of modified Y-configured stents with waffle cone technique.

Evaluation of the mechanical properties of current biliary selfexpandable metallic stents: axial and radial force, and axial force zero border

  • Wataru Yamagata;Toshio Fujisawa;Takashi Sasaki;Rei Ishibashi;Tomotaka Saito;Shuntaro Yoshida;Shizuka No;Kouta Inoue;Yousuke Nakai;Naoki Sasahira;Hiroyuki Isayama
    • Clinical Endoscopy
    • /
    • v.56 no.5
    • /
    • pp.633-649
    • /
    • 2023
  • Background/Aims: Mechanical properties (MPs) and axial and radial force (AF and RF) may influence the efficacy and complications of self-expandable metallic stent (SEMS) placement. We measured the MPs of various SEMSs and examined their influence on the SEMS clinical ability. Methods: We evaluated the MPs of 29 types of 10-mm SEMSs. RF was measured using a conventional measurement device. AF was measured using the conventional and new methods, and the correlation between the methods was evaluated. Results: A high correlation in AFs was observed, as measured by the new and conventional manual methods. AF and RF scatterplots divided the SEMSs into three subgroups according to structure: hook-and-cross-type (low AF and RF), cross-type (high AF and low RF), and laser-cut-type (intermediate AF and high RF). The hook-and-cross-type had the largest axial force zero border (>20°), followed by the laser-cut and cross types. Conclusions: MPs were related to stent structure. Hook-and-cross-type SEMSs had a low AF and high axial force zero border and were considered safest because they caused minimal stress on the biliary wall. However, the increase in RF must be overcome.

Impact of sarcopenia on biliary drainage during neoadjuvant therapy for pancreatic cancer

  • Kunio Kataoka;Eizaburo Ohno;Takuya Ishikawa;Kentaro Yamao;Yasuyuki Mizutani;Tadashi Iida;Hideki Takami;Osamu Maeda;Junpei Yamaguchi;Yukihiro Yokoyama;Tomoki Ebata;Yasuhiro Kodera;Hiroki Kawashima
    • Clinical Endoscopy
    • /
    • v.57 no.1
    • /
    • pp.112-121
    • /
    • 2024
  • Background/Aims: Since the usefulness of neoadjuvant chemo(radiation) therapy (NAT) for pancreatic cancer has been demonstrated, recurrent biliary obstruction (RBO) in patients with pancreatic cancer with a fully covered self-expandable metal stent (FCSEMS) during NAT is expected to increase. This study investigated the impact of sarcopenia on RBO in this setting. Methods: Patients were divided into normal and low skeletal muscle index (SMI) groups and retrospectively analyzed. Patient characteristics, overall survival, time to RBO (TRBO), stent-related adverse events, and postoperative complications were compared between the two groups. A Cox proportional hazard model was used to identify the risk factors for short TRBO. Results: A few significant differences were observed in patient characteristics, overall survival, stent-related adverse events, and postoperative complications between 38 patients in the normal SMI group and 17 in the low SMI group. The median TRBO was not reached in the normal SMI group and was 112 days in the low SMI group (p=0.004). In multivariate analysis, low SMI was the only risk factor for short TRBO, with a hazard ratio of 5.707 (95% confidence interval, 1.148-28.381; p=0.033). Conclusions: Sarcopenia was identified as an independent risk factor for RBO in patients with pancreatic cancer with FCSEMS during NAT.