• Title/Summary/Keyword: selectivity

Search Result 3,009, Processing Time 0.031 seconds

Korean welfare regime in the conservative administration, 2008-2016 (역진적 선별성의 지속과 확장성의 제약, 2008~2016: 이명박·박근혜 정부시기 한국복지체제의 특성)

  • Yoon, Hongsik
    • 한국사회정책
    • /
    • v.25 no.4
    • /
    • pp.163-198
    • /
    • 2018
  • This study analyzed the change of the Korean welfare regime during the conservative government. It is clear that the welfare expanded during the conservative government, but this expansion was the process of realizing the constraint of expansion that reduces future welfare expenditure in Korea. In addition, as the public welfare centered on social insurance expanded after 10 years of liberal government, the backward selectivity of the Korean welfare regime strengthened in the conservative administration. Expanding social insurance itself does not reinforce the backward selectivity of the Korean welfare regime. However, the industrial structure created by the export-led growth system has intensified the fragmentation of the labor market, and expanding social insurance designed based on regular workers under these conditions has forced the backward selectivity of the social security system. It is for this reason that the backward selectivity has been reinforced during the conservative government.

Hydrogen Perm-Selectivity Properties of the Pd-Ni-Ag Alloy Hydrogen Separation Membranes with Various Surface Nickel Composition (표면 니켈 조성에 따른 팔라듐-니켈-은 합금 수소분리막의 수소투과선택 특성)

  • Lim, Da-Sol;Kim, Se-Hong;Kim, Do-Hui;Cho, Seo-Hyun;Kim, Dong-Won
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.5
    • /
    • pp.277-290
    • /
    • 2018
  • In this study, Pd-Ni-Ag alloy hydrogen separation membranes were fabricated by Pd/Ag/Pd/Ni/Pd multi-layer sputter deposition on the modified MIM(Metal Injection Molding)-PSS(Porous Stainless Steel) support and followed heat treatment. Nickel, used as an alloying element in Pd alloy membranes, is inexpensive and stable material in a hydrogen isotope environment at high temperature up to 1123 K. Hydrogen perm-selectivity of Pd-Ni-Ag alloy membranes is affected not only by composition of membrane films but also by other factors such as surface properties of PSS support, microstructure of membrane films and inter-diffused impurities from PSS support. In order to clarify the effect of surface Ni composition on hydrogen perm-selectivity of Pd-Ni-Ag alloy membranes, the other effects were significantly minimized by the formation of dense and homogeneous Pd-Ni-Ag alloy membranes. Hydrogen permeation test showed that hydrogen permeability decreased from $7.6{\times}10^{-09}$ to $1.02{\times}10^{-09}mol/m{\cdot}s{\cdot}Pa^{0.5}$ as Ni composition increased from 0 to 16 wt% and the selectivity for $H_2/N_2$ was infinite.

Gas Separation Properties of PTMSP-GO Composite Membrane (PTMSP-GO 복합막의 기체분리 특성)

  • Lee, Seul Ki;Hong, Se Ryeong
    • Membrane Journal
    • /
    • v.28 no.2
    • /
    • pp.105-112
    • /
    • 2018
  • In this study, PTMSP-GO composite membranes were prepared by the addition of GO (graphene oxide) into PTMSP [poly (1-trimethylsilyl-1-propyne)] having high gas permeability, to study of gaseous membrane using GO. Gas permeation properties for $N_2$, $CH_4$, $CO_2$ were investigated by increasing the amount of GO in the PTMSP. PTMSP-GO composite membranes had higher gas permeability in the order of $N_2$ < $CH_4$ < $CO_2$. The gas permeation tendency of $N_2$, $CH_4$, and $CO_2$ increased as the content of GO increased from 0 to 10 wt%, but the gas permeability decreased as increased from 10 to 30 wt%. In the range of low GO contents, the gas permeability decreased due to the decrease of diffusivity because GO acts as a barrier in the composite membrane, and the gas permeability increased due to the void at the interface above the content range. And $CO_2$ has an affinity with -COOH of GO, the selectivity ($CO_2/N_2$) and the selectivity ($CO_2/CH_4$) gradually increase with increasing GO content. And the selectivity($CO_2/N_2$) showed the highest selectivity at 10.6 for PTMSP-GO 10 wt% and the selectivity ($CO_2/CH_4$) showed the highest selectivity at 3.4 for PTMSP-GO 20 wt%. However, above a certain amount of GO, selectivity ($CO_2/N_2$) and selectivity ($CO_2/CH_4$) decreased because the coagulation phenomenon between GO was increased and the solubility effect of $CO_2$ decreased. The PTMSP-GO 20 wt% composite membrane exhibited enhanced gas permeation characteristics with increased $CO_2$ permeability and selectivity ($CO_2/CH_4$) over PTMSP membrane.

A Study of the Effect of the Permeability and Selectivity on the Performance of Membrane System Design (분리막 투과도와 분리도 인자의 시스템 설계 효과 연구)

  • Shin, Mi-Soo;Jang, Dongsoon;Lee, Yongguk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.656-661
    • /
    • 2016
  • Manufacturing membrane materials with high selectivity and permeability is quite desirable but practically not possible, since the permeability and selectivity are usually inversely proportional. From the viewpoint of reducing the cost of $CO_2$ capture, module performance is even more important than the performance of membrane materials itself, which is affected by the permeance of the membrane (P, stagecut) and selectivity (S). As a typical example, when the mixture with a composition of 13% $CO_2$ and 87% of $N_2$ is fed into the module with 10% stage cut and selectivity 5, in the 10 parts of the permeate, $CO_2$ represents 4.28 parts and $N_2$ represents 5.72 parts. In this case, the $CO_2$ concentration in the permeate is 42.8% and the recovery rate of $CO_2$ in this first separation appears as 4.28/13 = 32.9%. When permeance and selectivity are doubled, however, from 10% to 20% and from 5 to 10, respectively, the $CO_2$ concentration in the permeant becomes 64.5% and the recovery rate is 12.9/13 = 99.2%. Since in this case, most of the $CO_2$ is separated, this may be the ideal condition. For a given feed concentration, the $CO_2$ concentration in the separated gas decreases if permeance is larger than the threshold value for complete recovery at a given selectivity. Conversely, for a given permeance, increasing the selectivity over the threshold value does not improve the process further. For a given initial feed gas concentration, if permeance or selectivity is larger than that required for the complete separation of $CO_2$, the process becomes less efficient. From all these considerations, we can see that there exists an optimum design for a given set of conditions.

Unbiasedness or Statistical Efficiency: Comparison between One-stage Tobit of MLE and Two-step Tobit of OLS

  • Park, Sun-Young
    • International Journal of Human Ecology
    • /
    • v.4 no.2
    • /
    • pp.77-87
    • /
    • 2003
  • This paper tried to construct statistical and econometric models on the basis of economic theory in order to discuss the issue of statistical efficiency and unbiasedness including the sample selection bias correcting problem. Comparative analytical tool were one stage Tobit of Maximum Likelihood estimation and Heckman's two-step Tobit of Ordinary Least Squares. The results showed that the adequacy of model for the analysis on demand and choice, we believe that there is no big difference in explanatory variables between the first selection model and the second linear probability model. Since the Lambda, the self- selectivity correction factor, in the Type II Tobit is not statistically significant, there is no self-selectivity in the Type II Tobit model, indicating that Type I Tobit model would give us better explanation in the demand for and choice which is less complicated statistical method rather than type II model.

Optimization of Selective Epitaxial Growth of Silicon in LPCVD

  • Cheong, Woo-Seok
    • ETRI Journal
    • /
    • v.25 no.6
    • /
    • pp.503-509
    • /
    • 2003
  • Selective epitaxial growth (SEG) of silicon has attracted considerable attention for its good electrical properties and advantages in building microstructures in high-density devices. However, SEG problems, such as an unclear process window, selectivity loss, and nonuniformity have often made application difficult. In our study, we derived processing diagrams for SEG from thermodynamics on gas-phase reactions so that we could predict the SEG process zone for low pressure chemical vapor deposition. In addition, with the help of both the concept of the effective supersaturation ratio and three kinds of E-beam patterns, we evaluated and controlled selectivity loss and non-uniformity in SEG, which is affected by the loading effect. To optimize the SEG process, we propose two practical methods: One deals with cleaning the wafer, and the other involves inserting dummy active patterns into the wide insulator to prevent the silicon from nucleating.

  • PDF

Membrane for the Removal of Volatile Organic Compounds from Air (대기중의 휘발성 유기물 제거용 분리막)

  • Deng, S.;Lang, K.;Wang, J.;Tremblay, A.;Matsuura, T.
    • Membrane Journal
    • /
    • v.7 no.1
    • /
    • pp.22-30
    • /
    • 1997
  • Porous asymmetric membranes were prepared from polyetherimide polymer by the phase-inversion technique under different conditions. The performance of the membranes was tested for the removal of acetone vapour from nitrogen. A membrane which showed a high acetone permeability and a high selectivity was chosen and tested further for the separation of different organic vapours from nitrogen. The molecular structure of organic vapours and the selectivity were correlated. A strong correlation was also found between the chromatographic retention time of the organic vapour and the selectivity. These experimental results led to the conclusion that the sorption is the factor governing the separation of volatile organic compounds from nitrogen. A membrane was also prepared by coating the surface of a porous polyetherimide membrane with silicone rubber. The performance of membranes with and without silicone rubber coating was compared.

  • PDF

Redesigning Taguchi Sensor

  • Hossein-Babaei Faramarz;Park, Won-Kyu
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.1
    • /
    • pp.11-15
    • /
    • 2005
  • The configuration of the main components and the physical structure of the Taguchi sensor, the first ceramic gas sensor mass produced, has remained virtually unaltered since its appearance 40 years ago. This device owns an excellent combination of the quality factors but is non-selective. The research efforts carried out to enhance the selectivity in this resistive gas sensor are briefly reviewed. A novel design, Capillary-attached Gas Sensor (CGS), is introduced, which employs the same ceramic components used for the fabrication of a classical Taguchi sensor but in altered geometries. CGS presents remarkable advantages from the view point of selectivity over the original design. While the steady state response of a CGS has the same significance as that of the Taguchi sensor, its transient response presents valuable diagnostic information. Fabrication and test of a prototype CGS is reported.

Dry Etching of Polysilicon in Hbr/O2 Inductively Coupled Plasmas (Hbr/O2 유도결합 플라즈마를 이용한 폴리실리콘 건식식각)

  • 범성진;송오성;이혜영;김종준
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • Dry etch characteristics of polysilicon with HBr/O$_2$ inductively coupled plasma (ICP) have been investigated. We determined etch late, uniformity, etch profiles, and selectivity with analyzing the cross-sectional scanning electron microscopy images obtained from top, center, bottom, right, and left positions. The etch rate of polysilicon was about 2500 $\AA$/min, which meets with the mass production for devices. The wafer level etch uniformity was within $\pm$5 %. Etch profile showed 90$^{\circ}$ slopes without notches. The selectivity over photoresist was between 2:1∼4.5:1, depending on $O_2$ flow rate. The HBr-ICP etching showed higher PR selectivity, and sharper profile than the conventional Cl$_2$-RIE.

Wavelength and polarization selectivity of a side-polished fiber contacted with a metal-clad planar waveguide (금속 클래드 평면 도파로와 결합된 측면 연마 광섬유의 파장 및 편광 선택성)

  • 김광택;황중호;이준옥;김철호;황보승
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.2
    • /
    • pp.134-139
    • /
    • 2002
  • We report an experimental investigation of the wavelength and polarization selectivity of a side-polished fiber in contact with a metal-clad planar waveguide. The influences of the structural parameters of the planar waveguide, including refractive index of the superstrate and metal thickness, on the optical transmission characteristics of the device were measured and explained. The conditions for high wavelength and polarization selectivity wore predicted and demonstrated experimentally.