• 제목/요약/키워드: selective

검색결과 7,978건 처리시간 0.038초

이하선 기능 보존을 위한 심층엽의 선택적 절제술: 증례보고 (SELECTIVE DEEP LOBE PAROTIDECTOMY FOR PRESERVATION OF PAROTID FUNCTION: A CASE REPORT)

  • 정승원;최세경;남웅;차인호;김형준
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권5호
    • /
    • pp.384-387
    • /
    • 2009
  • Tumors of the deep lobe of parotid gland are rare. These benign tumors have usually been treated by total parotidectomy, which has functional and esthetic side effects. Recently, there has been a trend for operations of parotid gland benign tumors to be less radical and selective deep lobe parotidectomy has been introduced. This technique preserves the superficial lobe and facial nerve when tumor is located in the deep lobe. Selective deep lobe parotidectomy preserves parotid salivary function, minimizes the incidence of facial nerve damage and gustatory sweating (Frey's syndrome) and improves cosmetic outcome. We report a case of pleomorphic adenoma of the deep lobe that was successfully treated by selective deep lobe parotidectomy with satisfactory result.

Comparison Analysis of Resonant Controllers for Current Regulation of Selective Active Power Filter with Mixed Current Reference

  • Yi, Hao;Zhuo, Fang;Li, Yu;Zhang, Yanjun;Zhan, Wenda
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.861-876
    • /
    • 2013
  • Instead of extracting every selected harmonic component, the current reference of selective active power filter (APF) can be also obtained by filtering out the fundamental component from distorted load current for computation efficiency. This type of mixed current reference contains kinds of harmonic components and easily involves noises. In this condition, selective harmonic compensation must be realized by the current controller. With regard that selectivity is the most significant feature of controller, this paper presents specific comparison analysis between two types of resonant controllers: proportional-resonant (PR) controller and vector-resonant (VR) controller. The comparison analysis covers the relations, performances, and stability of both controllers. Analysis results conclude that the poorer selectivity of the PR controller could be relatively improved, but limitations from system stability make the improvement hardly realized. By contrast, the VR controller exhibits excellent selectivity and is more suitable for selective APF with mixed current reference. Experimental results from laboratory prototype validate the reasonability of analysis. And the features of each resonant controller are concluded.

금속 구조 변화에 따른 선택 화학기상증착 W Plug의 접합 신뢰성 연구 (The Effects of Metal Structure on the Junction Stability of Sub-micron Contacts Using Selective CVD-W Plug)

  • 최경근;김춘환;박흥락;고철기
    • 전자공학회논문지A
    • /
    • 제31A권5호
    • /
    • pp.94-100
    • /
    • 1994
  • The junction failure mechanism of W plugs has not been fully understood while the selective W deposition has been widely used for plugging interconnection lines. In this paper, the thermal stability and junction failure mechanism of sub-micron contacts using selective CVD-W plugs were intensively studied with the metal lines of AISiCu, Ti/AISiCu and TiN/AISiCu. The experimental results showed that the contact chain resistance and leakage current in the AISiCu and Ti/AISiCu metallizations were significantly degraded after annealing. From the SEM analysis, it was found that the junction spiking, due to the Al atoms diffusion along the porous interface between selective CVD-W and contactside wall, caused the junction failure. In constast, there was no degradation of the contact resistance and junction leakage current in TiN/AISiCu metal structu-re. It is believed that the TiN barrier layer could prevent AI(Ti) atoms Fromdiffusing. Therefore, TiN barrier between W plug and Al should be used to impro-ve the thermal stability of sub-micron contacts using the selective CVD-W plugs.

  • PDF

요추부 선택적 신경근 차단술 이후 발생한 Wallenberg's Syndrome의 한방복합치료 1례 (Treatment of Wallenberg's Syndrome Following Selective Nerve Root Block: A Case Report)

  • 박서현;권정국;박재원;금동호
    • 한방재활의학과학회지
    • /
    • 제26권4호
    • /
    • pp.107-115
    • /
    • 2016
  • The occurrence of brain stem stroke after lumbar selective nerve root block seem to be an uncommon event comparing it to after cervical selective nerve root block. We recently experienced a 60-year-old man who were diagnosed as left lateral medullary infarction (Wallenberg's syndrome) after lumbar selective nerve root block. He was treated by traditional Korean medicine with acupunture, Pulsed electromagetic therapy (PEMT), herb medicine. The range of motion of upper and lower extremity, manual muscle test, Korean version of Berg balance scale (K-BBS) and Korean version of Barthel index (K-MBI) were adopted to measure the resulting recovery after 4 weeks treatment. Traditional Korean medicine was effective for rehabilitation of patient. Further studies are needed to set up and Korean medical protocol for Wallenberg's syndrome.

Pexophagy: Molecular Mechanisms and Implications for Health and Diseases

  • Cho, Dong-Hyung;Kim, Yi Sak;Jo, Doo Sin;Choe, Seong-Kyu;Jo, Eun-Kyeong
    • Molecules and Cells
    • /
    • 제41권1호
    • /
    • pp.55-64
    • /
    • 2018
  • Autophagy is an intracellular degradation pathway for large protein aggregates and damaged organelles. Recent studies have indicated that autophagy targets cargoes through a selective degradation pathway called selective autophagy. Peroxisomes are dynamic organelles that are crucial for health and development. Pexophagy is selective autophagy that targets peroxisomes and is essential for the maintenance of homeostasis of peroxisomes, which is necessary in the prevention of various peroxisome-related disorders. However, the mechanisms by which pexophagy is regulated and the key players that induce and modulate pexophagy are largely unknown. In this review, we focus on our current understanding of how pexophagy is induced and regulated, and the selective adaptors involved in mediating pexophagy. Furthermore, we discuss current findings on the roles of pexophagy in physiological and pathological responses, which provide insight into the clinical relevance of pexophagy regulation. Understanding how pexophagy interacts with various biological functions will provide fundamental insights into the function of pexophagy and facilitate the development of novel therapeutics against peroxisomal dysfunction-related diseases.

H$^+$ 선택성 막 전극을 이용한 바이오센서의 감응 특성 (Characteristic Responses of Biosensor Based on $H^+$-Selective Membrance Electrode)

  • 김기묘;박성배;황명석;허문회;안문규
    • 약학회지
    • /
    • 제40권6호
    • /
    • pp.625-631
    • /
    • 1996
  • The $H^+$-selective membrane consists of tridodecylamine, 2-nitrophenyl octyl ether and a little amount of additive in carboxylated PVC matrix, where penicillinase(Pcase ) and glutaraldehyde may be covalently attached to the matrix. When the $H^+$-selective electrode was used as a detector of biosensor, calibration curve calculated from Nernst equation was not linear. So we investigated the characteristic responses of the $H^+$-selective electrode to the product H+ from hydrolysis of penicillin-G(Pc-G) and plotted calibration curve correlating potential to concentration of Pc-G linearly. The optimal concentration of buffer solution was theoretically calculated and was also experimented. We tried to explain the linear curve of potential to concentration of Pc-G by using Henderson-Hasselbach equation. This method is more effective in calibration curve plotting than any other previous methods. The results obtained may help in further developing pH electrodes with improved analytical preformance.

  • PDF

맞물린 나노전극을 가지는 마이크로 캔틸레버의 제작 및 순환전압전류방법을 이용한 DNA의 선택적인 고정화 (DNA Selective Immobilization on a Microcantilever with Nano-Interdigitated Electrodes (Nano-IDEs) Using Cyclic Voltammetry)

  • 이정아;이광철
    • 대한기계학회논문집A
    • /
    • 제32권6호
    • /
    • pp.459-464
    • /
    • 2008
  • We present a novel microcantilever device with nano-interdigitated electrodes (nano-IDEs) and DNA selective immobilization on the nano-IDEs for biosensing applications. Using the nano-IDEs and cyclic voltammetric methods, we have achieved selective immobilization of DNA with submicrometer spatial resolution on a freestanding microcantilever. $70{\sim}500\;nm$-wide gold (Au) nano-IDEs are fabricated on a low-stress SiNx microcantilever with dimensions of $100{\sim}600\;{\mu}m$ in length, and $15{\sim}60\;{\mu}m$ in width, with a $0.5\;{\mu}m$ thickness using electron beam lithography and bulk micromachining. Streptavidin is selectively deposited on one side of the nano-IDEs using cyclic voltammetry at a scan rate of 0.1 V/s with a range of $-0.2{\sim}0.7\;V$ during $1{\sim}5$ cycles. The selective deposition of dsDNA is confirmed by fluorescence microscopy after labeling with YOYO-1 dye.

전역 초음파 시스템의 선택적 활성화 (Selective Activation for Global Ultrasonic System)

  • 김진원;김용태;황병호;이수영
    • 제어로봇시스템학회논문지
    • /
    • 제12권10호
    • /
    • pp.955-961
    • /
    • 2006
  • The global ultrasonic system for the self-localization of a mobile robot consists of several ultrasonic transmitters fixed at some reference positions in the global coordinates of robot environment. By activating the ultrasonic transmitters, the mobile robot is able to get the distance to the ultrasonic transmitters and compute its own position in the global coordinate. Due to the limitation on the ultrasonic signal strength and beam width as well as the environmental obstacles however, the ultrasonic signals from some generator may not be transmitted to the robot. Thus, instead of activating the all ultrasonic transmitters, it is necessary to select some ultrasonic generators to activate based on the current robot position. In this paper, we propose a selective activation algorithm for self-localization with the global ultrasonic system. The selective activation algorithm gets the meaningful ultrasonic data at every sampling instants, which results in the faster and more accurate response of the self-localization than the conventional sequential activation. Through the self-localization and path following control, we verify the effectiveness of the proposed selective activation algorithm.

고온용 태양 선택흡수막의 제작 (Deposition of Solar Selective Coatings for High Temperature Applications)

  • 이길동
    • 한국태양에너지학회 논문집
    • /
    • 제28권1호
    • /
    • pp.33-42
    • /
    • 2008
  • Zr-O ($Zr-ZrO_2$) cermets solar selective coatings with a double cermets layer film structure were prepared using a DC (direct current) magnetron sputtering method. The typical film structure from surface to bottom substrate were an $Al_2O_3$ anti-reflection layer on a double Zr-O cermets layer on an Al metal infrared reflection layer. Optical properties of optimized Zr-O cermets solar selective coating had an absorptance of ${\alpha}\;=\;0.95$ and thermal omittance of ${\epsilon}\;=\;0.10\;(100^{\circ}C)$. The absorbing layer of Zr-O cermets coatings on glass and silicon substrate was identified as being amorphous by using XRD. AFM showed that ZF-O cermets layers were very smooth and their surface roughness were approximately $0.1{\sim}0.2 nm$. The chemical analysis of the cermets coatings were determined by using XPS. Chemical shift of photoelectron binding energy was occurred due to the change of Zr-O cermets coating structure deposited with increase in oxygen flow rate. The result of thermal stability test showed that the Zr-O cermets solar selective coating was stable for use at temperature below $350^{\circ}C$.

Biologically-Inspired Selective and Sensitive Trinitrotoluene Sensors Using Conjugated Lipid-like Polymer Nanocoatings for CNT-FET Sensors

  • Jaworski, Justyn;Kim, Tae-Hyun;Yokoyama, Keisuke;Chung, Woo-Jae;Wang, Eddie;Lee, Byung-Yang;Hong, Seung-Hun;Majumdar, Arun;Lee, Seung-Wuk;Kwon, Ki-Young
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.495-495
    • /
    • 2011
  • Miniaturized sensors capable of both sensitive and selective real-time monitoring of target analytes are tremendously valuable for various applications ranging from hazard detection to medical diagnostics. The wide-spread use of such sensors is currently limited due to insufficient selectivity for target molecules. We developed selective nanocoatings by combining trinitrotoluene (TNT) receptors bound to conjugated polydiacetylene (PDA) with single-walled carbon nanotube-field effect transistors (SWNT-FET). Selective binding events between TNT molecules and phage display derived TNT receptors were effectively transduced to sensitive SWNT-FET conductance sensors through the PDA coating. The resulting sensors exhibited unprecedented 1 fM sensitivity toward TNT in real time, with excellent selectivity over various similar aromatic compounds. Our biomimetic receptor coating approach may be useful for the development of sensitive and selective micro and nanoelectronic sensor devices for various other target analytes.

  • PDF