• Title/Summary/Keyword: selective

Search Result 7,978, Processing Time 0.033 seconds

Optical Properties and Structure of Black Cobalt Solar Selective Coatings (흑색 코발트 태양 선택흡수막의 광학적특성과 구조)

  • Lee, Kil-Don
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.48-56
    • /
    • 2011
  • Black cobalt solar selective coatings were prepared by thermal oxidation of electroplated cobalt metal on copper and nickel substrates. The optical properties and structure of the black cobalt selective coating for solar energy utilizations were characterized by glow discharge spectrometry (GDS), ultraviolet-visible-near infrared (UV-VIS-NIR) spectrometer, atom force microscopy(AFM) and X-ray photoelectron spectroscopy(XPS). The optical properties of optimum black cobalt selective coating prepared on copper substrate were a solar absorptance of 0.82 and a thermal emittance of 0.01. From the GDS depth profile analysis of these coatings, the concentration of cobalt particles near the interface was higher than at the surface, but oxygen concentration at the surface was higher than at the interface. These results suggest that the selective absorption was dominated by this chemical composition variation in the coating. The surface of this film exhibited morphology with root-mean-square(rms) roughness of about 144.3nm. XPS measurements data showed that several phases of Co coexist($Co_3O_4$,CoO) in the film.

Cr-Co removable partial denture treatment fabricated by selective laser melting: a case report (Selective Laser Melting을 이용한 코발트-크롬 가철성 국소의치의 수복 증례)

  • Yim, Ji-Hun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.1
    • /
    • pp.39-47
    • /
    • 2021
  • Compared to conventional method, if metal framework of removable partial denture is fabricated by selective laser melting, various laboratory works are omitted, saving time and simplifying the process. In addition, metal framework with homogeneous density can be obtained, expecting excellent mechanical properties, especially resistance to fatigue fracture. In these cases, impression were taken using conventional methods in partial edentulous patients, master casts were fabricated and scanned to obtain digital data. After designing the metal frameworks on the scanned data, removable partial dentures were fabricated using selective laser melting methods. Through these procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

Recognition of Superimposed Patterns with Selective Attention based on SVM (SVM기반의 선택적 주의집중을 이용한 중첩 패턴 인식)

  • Bae, Kyu-Chan;Park, Hyung-Min;Oh, Sang-Hoon;Choi, Youg-Sun;Lee, Soo-Young
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.5 s.305
    • /
    • pp.123-136
    • /
    • 2005
  • We propose a recognition system for superimposed patterns based on selective attention model and SVM which produces better performance than artificial neural network. The proposed selective attention model includes attention layer prior to SVM which affects SVM's input parameters. It also behaves as selective filter. The philosophy behind selective attention model is to find the stopping criteria to stop training and also defines the confidence measure of the selective attention's outcome. Support vector represents the other surrounding sample vectors. The support vector closest to the initial input vector in consideration is chosen. Minimal euclidean distance between the modified input vector based on selective attention and the chosen support vector defines the stopping criteria. It is difficult to define the confidence measure of selective attention if we apply common selective attention model, A new way of doffing the confidence measure can be set under the constraint that each modified input pixel does not cross over the boundary of original input pixel, thus the range of applicable information get increased. This method uses the following information; the Euclidean distance between an input pattern and modified pattern, the output of SVM, the support vector output of hidden neuron that is the closest to the initial input pattern. For the recognition experiment, 45 different combinations of USPS digit data are used. Better recognition performance is seen when selective attention is applied along with SVM than SVM only. Also, the proposed selective attention shows better performance than common selective attention.

Thallium(Ⅰ)-Selective Membrane Potentiometric Sensor Based on Dibenzyldiaza-18-Crown-6

  • Khayatian, Gholamreza;Shariati, Satar;Salimi, Abdollah
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.4
    • /
    • pp.421-425
    • /
    • 2003
  • A new thallium(Ⅰ) selective electrode based on dibenzylidaza-18-crown-6 as mambrane carrier was successfully prpared. The electrode exhibitis a near-Nernstian response for $ T1^+$ ions over a wide concentration range from $1.0×10^{15}-1.0×10^{-1}$M at 25℃, and was found to be selective, precise and useable within the pH range 4.0-11.0. The electrode was successfully used as an indicator electrode in potentiometric titration of thallium ions.

Selective Inhibitory Effect of New Phosphodiesterase Inhibitors on PDE Isozymes in Guinea pig Cardiac Muscle

  • Lee, Sun-Kyeong;Kwon, Kwang-Il;Zee, Ok-Pyo
    • Archives of Pharmacal Research
    • /
    • v.12 no.4
    • /
    • pp.276-281
    • /
    • 1989
  • Selective inhibition of seven new PDE inhibitors on cyclic nucleotide PDE isozymes was investigated. Three PDE isozymes (PDE I, II and III) of guinea pig left ventricular muscles were used. All tested agents inhibited cyclic AMP hydrolysis by PDE III IN A concentration-dependent manner. Some agents represented more potent and selective inhibitory effect on PDE III than that of imazodan.

  • PDF

Loop Selective Direction Measurement for Distance Protection

  • Steynberg, Gustav;Koch, Geyhard
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.423-426
    • /
    • 2006
  • Distance relays achieve selective tripping by measurement of all short circuit fault conditions inside set reaches. The direction of the fault, forward or reverse is commonly determined with a dedicated measurement to ensure selectivity under all conditions. For the direction decision (measurement) a number of alternatives are available. This paper describes a loop selective direction measurement and illustrates by means of a typical fault why this is superior to a non loop selective direction measurement such as that based on negative sequence quantities.

Sodium Ion-Selective Membrane Electrode Based on Dibenzopyridino-18-Crown-6

  • Tavakkoli, Nahid
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1474-1476
    • /
    • 2004
  • A sodium ion- selective electrode based on dibenzopyridino-18-crown-6 as membrane carrier was successfully prepared. The electrode exhibits a Nernstian response for $Na^+$ ions within the concentration range of $1.0\;{\times}\;10^{-4}-1.0\;{\times}\;10^{-1}$ M. The response time of the sensor is 20 s. The sodium ion-selective electrode exhibited comparatively good selectivities with respect to alkali, alkaline earth and some transition metal ions.

Analysis of Wireless Signal Strength in Indoor Environment with Film-Type Dual-Band Frequency Selective Structure (필름형 이중 대역 주파수 선택 구조가 적용된 실내 환경의 무선신호강도 분석)

  • Cho, Sung-Sil;Lee, Sang-Hwa;Yoon, Sun-Hong;Hong, Ic-Pyo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • In this paper, we propose a film-type dual-band frequency selective structure for improving the wireless communication environment in a building. The proposed frequency-selective structure is a miniaturized structure that can control the resonant frequencies of 2.4 GHz and 5 GHz dual band through simple design parameters. We fabricated the frequency-selective surface by screen printing using conductive ink on a thin transparent film and confirmed its performance by measurement. We analyzed the attenuation performance of the unnecessary signal from the outside when the frequency-selective structure designed using the software to analyze the propagation environment performance is applied to the building. To verify the analytical results, the signal strength of the indoor environment was measured by applying the frequency-selective film fabricated on the inner wall of the actual building. The measurement results show that the dual-band frequency-selective film has 29.4 dB and 15.94 dB attenuation performance in the 2.4 GHz and 5 GHz, respectively.

Impact of Selective Health Benefit on Medical Expenditure and Provider Behavior: Case of Gastric Cancer Surgery (선별급여 도입이 위암수술의 건강보험 진료비 및 진료행태에 미치는 영향)

  • Cho, Su-Jin;Ko, Jung-Ae;Choi, Yeonmi
    • Health Policy and Management
    • /
    • v.26 no.1
    • /
    • pp.63-70
    • /
    • 2016
  • Background: Selective health benefit was introduced for decreasing economic burden of patients. Medical devices with economic uncertainty have been covered as selective health benefit by National Health Insurance since December 2013. We aimed to analyze impact of selective health benefit to medical expenditure and provider behavior focused on electrosurgery (ultrasonic shears, electrothermal bipolar vessel sealers) for gastric cancer patients covered since December 2014. Methods: We used the National Health Insurance claims data of 2,698 patients underwent gastric cancer surgery between August 2014 and March 2015. Medical cost and patient sharing per inpatient day were analyzed to verify that covering electrosurgery increased medical expenditure and changed provider behavior from open surgery to endoscopic or laparoscopic surgery. Additionally, we analyzed the claim rate of medical device or goods relating gastric endoscopic and laparoscopic surgery. Results: Medical cost and patient sharing per inpatient day were increased after covering electosurgery as selective health benefit (39,724/1,421 won). However, there were no medical expenditure increases after adjusting claim of electosurgery and patient sharing was decreased 1,057 won especially. The coverage of selective health benefit did not increase the claim rate of medical device or goods related endoscopic or laparoscopic surgery, either. Conclusion: Covering electosurgery decreased patient economic burden and did not change of provider behavior. Expanding selective health benefit is needed to decrease economic burden of severe patients. Further study should evaluate the long term effect with accumulated data.

The Change of 'Attention Resources' and 'Space-Memory' by Lighting focusing on 'Selective Attention (선택적 주의 관점에서 본 조명에 의한 주의 자원과 공간 기억의 변화)

  • Seo, Ji-Eun
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.2
    • /
    • pp.41-49
    • /
    • 2016
  • The purpose of this study is to analyze the change and to compare to the difference of 'selective elements' and 'space-memory' focusing on the theory, 'selective attention' through the survey results. In this study, In this study, the lighting is considered a important factor in the change of 'selective elements'. this survey is to find the selective elements of participants and to measure the spatial sensitivity of respondents through 'self- test'. The analysis in this study is conducted by descriptive statistics, t-test and one way ANOVA by SPSS program 22. The results of this study are as following; Firstly, 'attention-element' could be classified with 4 types, 'shape', 'material', 'contrast' and 'combination'. 'shape' could divide into 'structure' and' furniture and object'. In case of 'material', it could section with 'pattern' and 'color'. Secondly, through the results of study, 'attention-element' is different each space during the day in detail. But we could know that 'shape' is the important element of the 'attention-elements' during the day through comparison of this result. That means users consider this as a important factor when they evaluate the space. Therefore, it is effective way designers to consider 'shape' as the first element when they want to conduct the special sensitivity of users in the space through planning. On the other hand, what selective elements of users are different by the lighting situation should be acknowledged by designers. And they should think the kinds of selective elements are more various when lighting turns on than turns off.. Thirdly, through the results such as the meaningful difference of space-memory of users according to the change of 'attention-elements', designers should judge about which kind of feeling of users to the space do you want lead in the design process. For the effective feedback between spaces and users to induce the same emotion of users, designers need to consider the unified design and the individual design both. Also, we will regard the differences in the users' emotion to the space according to the lighting situation when we design the space.