• Title/Summary/Keyword: sectioning method

Search Result 67, Processing Time 0.027 seconds

A Study of the Internal and External Morphology in the Mandibular first Premolar of the Middle-Aged Korean Using a Microcomputed Tomography (미세단층촬영기를 이용한 중년 한국인 하악 제1소구치의 내 외부 형태학 연구)

  • Chun, K.J.;Lee, H.J.;Lee, Jong-Yeop
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.254-261
    • /
    • 2005
  • Dental statistics for Koreans are far from complete and the majority of previous researches have adopted techniques such as radiological analysis and sectioning of teeth for morphological information, which are time-consuming, less accurate and destructive. Thus, a new nondestructive method is necessary to get precise dental standardization data for Koreans. For the above purpose, each of the first premolars was scanned by a micro-CT (SkyScan, Belgium) with a resolution of $21.31{\mu}m$ at an interval of 0.022mm along the plane horizontally parallel to an occlusion plane. Internal and external morphological sections were measured and compared to the values in the average tooth size table for permanent teeth presented by G. V Black.

A Study on the Structural Behavior of Profiled Composite Beams (박판 냉간성형강 합성보의 구조적 거동에 관한 연구)

  • Yang, Gu Rok;Hwang, Young Seo;Song, Jun Yeup;Kwon, Young Bong
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.2 s.39
    • /
    • pp.143-151
    • /
    • 1999
  • An analytical study on the behavior of composite beams, which are composed of cold-formed profiled steel sheeting and normal strength concrete, is described. An analytical method to trace the nonlinear behavior of a composite beam is developed to include the nonlinear material properties of steel sheeting, reinforcing steel bar and concrete. A simple Power Model has also been proposed for the nonlinear moment-curvature relation of the composite beam. The model, which has been originally used to predict the flexural capacity of the beam to column connections, is adapted to the composite beams. The load-deflection behavior of the beams has been simulated by the step-by-step numerical integration using the moment-curvature relation obtained by the Power Model. The results have been compared with test results.

  • PDF

Restoration of Blink Function in the Paralyzed Rabbit Using Electroactive Polymer (안면신경마비 동물모델에서 전기활성고분자를 이용한 눈 깜박임 기능의 회복)

  • Kwon, Seong-Keun;Sung, Myung-Whun;Kim, Kwang-Hyun;Kim, Hee-Chan
    • Korean Journal of Bronchoesophagology
    • /
    • v.12 no.2
    • /
    • pp.19-25
    • /
    • 2006
  • There have been numerous modalities to recover blink function of orbicularis oculi muscle in patients with facial paralysis. However, there is still no optimal method for reanimation of eyelid. In this study, we tried to recover blink function of paralyzed rabbit's eyelid with the ion polymer metal composite (IPMC) which is one of the electroactive polymers that is spotlighted as artificial muscle. We manufactured IPMC by plating the platinum over perfluorosulphonic acid polymer ($Nafion^{(R)}$). IPMC was coated by Norland optical adhesive for the purpose of insulation and keeping it from dry. IPMC modifications by roughening the surface of Nafion, repetitive plating (maximum 4 times) with platinum, and lengthening the width of IPMC were done. The facial paralysis was induced in the rabbit by sectioning of facial nerve at the main trunk. After minimum period of 4 weeks, IPMC was inserted in the paralyzed rabbit's eyelid. By modification, the force generated by IPMC was enhanced. Restoration of blink function in paralyzed rabbit was achieved on electrical stimulation of the IPMC by 5 voltage direct current. IPMC can be promising option for facial reanimation, but further studies are needed to enhance the efficiency of IPMC.

  • PDF

A Quantitative Study of the Quality of Deconvolved Wide-field Microscopy Images as Function of Empirical Three-dimensional Point Spread Functions

  • Adur, Javier;Vicente, Nathalie;Diaz-Zamboni, Javier;Izaguirre, Maria Fernanda;Casco, Victor Hugo
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.252-263
    • /
    • 2011
  • In this work, for the first time, the quality of restoration in wide-field microscopy images after deconvolution was analyzed as a function of different Point Spread Functions using one deconvolution method, on a specimen of known size and on a biological specimen. The empirical Point Spread Function determination can significantly depend on the numerical aperture, refractive index of the embedding medium, refractive index of the immersion oil and cover slip thickness. The influence of all of these factors is shown in the same article and using the same microscope. We have found that the best deconvolution results are obtained when the empirical PSF utilized is obtained under the same conditions as the specimen. We also demonstrated that it is very important to quantitatively check the process' outcome using several quality indicators: Full-Width at Half-Maximum, Contrast-to-Noise Ratio, Signal-to-Noise Ratio and a Tenengrad-based function. We detected a significant improvement when using an indicator to measure the focus of the whole stack. Therefore, to qualitatively determinate the best deconvolved image between different conditions, one approach that we are pursuing is to use Tenengrad-based function indicators in images obtained using a wide-field microscope.

Three dimensional structural analysis between dental arch and basal bone in normal occlusion (정상교합자의 치열궁과 기저골 형태에 대한 3차원적 연구)

  • Kim, Jee-Tae;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.41 no.4
    • /
    • pp.224-236
    • /
    • 2011
  • Objective: The purpose of this study was to analyze the dental and basal arch forms in patients with normal occlusion using the computed tomography (CT) imaging method. Methods: CT images were taken from 27 normal occlusion subjects (male, 15; female, 12) and these images were reconstructed into three-dimensional models. A 3D-coordinate system was formed by setting the middle of the facial axis (FA) point of the maxillary central incisors as the origin. The morphology of the maxilla and mandibular dental and basal arches were analyzed by sectioning parallel to the maxillary occlusal plane. Results: There was no significant difference between A point and B point and between the maxillary 1st molars in both sides of the maxillary and mandibular basal bone. The dental arch was located more labially than the basal arch in the anterior portion. The bucco-lingual crossover of the dental arch and basal arch was formed at the molar region in the maxilla, and at the premolar region in the mandible. Conclusions: This study will help provide three-dimensional diagnostic information about the relationship between basal and dental arches in patients who have severe dental compensation and inappropriate jaw relationships.

The Effect of Abnormal Intermetallic Compounds Growth at Component on Board Level Mechanical Reliability (컴포넌트에서의 비정상적인 금속간화합물 성장이 보드 레벨 기계적 신뢰성에 미치는 영향)

  • Choi, Jae-Hoon;Ham, Hyon-Jeong;Hwang, Jae-Seon;Kim, Yong-Hyun;Lee, Dong-Chun;Moon, Jeom-Ju
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.2
    • /
    • pp.47-54
    • /
    • 2008
  • In this paper, we studied how and why did abnormal IMC growth at component affect on board level mechanical reliability. First, interfacial reactions between Sn2.5Ag0.5Cu solder and electrolytic Ni/Au UBM of component side were investigated with reflow times and thermal aging time. Also, to compare mechanical reliability of component level, shear energy was evaluated using the ball shear test conducted with variation of shear tip speed. Finally, to evaluate mechanical reliability of board level, we surface-mounted component fabricated with each condition on PCB side. After conducting of 3 point bending test and impact test, we confirmed solder joint crack mode using cross-sectioning and dye & pry penetration method.

  • PDF

Effect of soldering techniques and gapdistance on tensile strength of soldered Ni-Cr alloy joint

  • Lee, Sang-Yeob;Lee, Jong-Hyuk
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.4
    • /
    • pp.117-121
    • /
    • 2010
  • PURPOSE. The present study was intended to evaluate the effect of soldering techniques with infrared ray and gas torch under different gap distances (0.3 mm and 0.5 mm) on the tensile strength and surface porosity formation in Ni-Cr base metal alloy. MATERIALS AND METHODS. Thirty five dumbbell shaped Ni-Cr alloy specimens were prepared and assigned to 5 groups according to the soldering method and the gap distance. For the soldering methods, gas torch (G group) and infrared ray (IR group) were compared and each group was subdivided by corresponding gap distance (0.3 mm: G3 and IR3, 0.5 mm: G5, IR5). Specimens of the experimental groups were sectioned in the middle with a diamond disk and embedded in solder blocks according to the predetermined distance. As a control group, 7 specimens were prepared without sectioning or soldering. After the soldering procedure, a tensile strength test was performed using universal testing machine at a crosshead speed 1 mm/min. The proportions of porosity on the fractured surface were calculated on the images acquired through the scanning electronic microscope. RESULTS. Every specimen of G3, G5, IR3 and IR5 was fractured on the solder joint area. However, there was no significant difference between the test groups (P > .05). There was a negative correlation between porosity formation and tensile strength in all the specimens in the test groups (P < .05). CONCLUSION. There was no significant difference in ultimate tensile strength of joints and porosity formations between the gas-oxygen torch soldering and infrared ray soldering technique or between the gap distance of 0.3 mm and 0.5 mm.

Re-distribution of Welding Residual Stress Due to Tensile Pre-load and Its Effects on Fatigue Strength in Padding Plate Weldment (Padding plate 용접구조의 인장 정하중 이력에 의한 용접잔류응력 변화 및 피로강도에의 영향)

  • S.W. Kang;Y.W. Kim;W.S. Kim;D.H. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.38 no.4
    • /
    • pp.75-82
    • /
    • 2001
  • Static loadings on ship structure induced either by water pressure before service such as a tank test and ballasting or by cargo pressure during first laden voyage cause relatively much greater stress than dynamic loadings induced by wave. With these static pre-loadings, the initial residual stresses around welded joint, where fatigue strength is concerned(in most cases, where stress concentration occurs) are expected to be shaken-down in a great extent by the elasto-plastic deformation behavior of material. Therefore, it is more resonable to assess the fatigue strength of ship structure with S-N data which have taken into account the effect of shaken-down residual stresses(re-distributed stresses) on the fatigue strength. In this research work, the re-distribution of residual stresses by the tensile pre-loading is measured using an ordinary sectioning method for specimens of padding plate weldment. Fatigue tests are performed also to evaluate the fatigue strength of the both as-welded and pre-loaded specimens.

  • PDF

Study on methodology for the assessment of internal and marginal adaptation on fixed dental prosthesis (고정성 보철물의 내면 및 변연적합도를 평가하는 방법에 대한 고찰)

  • Pyo, Se-Wook;Lee, Jun-Jae;Han, Jung-Suk;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.158-168
    • /
    • 2016
  • This article is to review various methods used to investigate internal and marginal adaptation of fixed dental prostheses, and to summarize a merit, worth, and limitation of each method, using some results of previous studies. The methods of measuring internal and marginal gap are divided into two categories in this study; in vivo and in vitro. In vivo methods are clinical evaluations, including exploration, radiography, and impression technique. In vitro methods are laboratory evaluations such as direct view, cross-sectioning, and silicone replica technique using microscope. Measuring by micro computed tomography (CT) or profilometer is also in vitro methods. In recent years, the development of scanning systems is able to analyze 3-dimensional internal and marginal space in detail. As measuring and analyzing technology become more advanced, the ability to thoroughly examine crown adaptation is becoming both simpler and more efficient.

A COMPARATIVE STUDY ON THE APICAL LEAKAGE OF RETROFILLING AFTER APICAL CAVITY PREPARATION WITH ULTRASONIC INSTRUMENT (초음파 기구에 의한 치근단 와동형성후 역충전의 밀폐성에 대한 연구)

  • Lee, Hyeong-Il;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.197-204
    • /
    • 1993
  • This study was conducted to evaluate and compare the apical leakage in the following retrofilling techniques after apical resection; No apical cavity preparation and no retrofilling(control group), Amalgam(group I) or silver glass ionomer cement(group II) retrofilling after apical cavity preparation with mini contra-angle and bur, Amalgam(group III) or silver glass ionomer cement(group N) retrofilling after apical cavity preparation with ultrasonic micro endo tip. Extracted ninety upper anterior and lower canine teeth were fixed in skull simulators and root canals were prepared with step-back method and obturated with gutta-percha and zinc oxide eugenol sealer. Obturated roots were resected 2mm from apical ends and apical cavities of 1mm width and 2mm depth were prepared and retrofilled by above mentioned methods. After application of nail varnish on all surface except resected surface, apical 1/3 of the roots were placed in 1% methylene blue solution for 3 days. After longutudinal sectioning to expose central parts of filled materials, depths of penetrated dye were measured by measuring microscope and were analyzed statistically. The results were as follows. 1. Having no relation with instruments used in apical cavity preparation, amalgam retrofilling groups(group I and II) showed less apical leakage which was not significant statistically than no retrofilling group(control group) (P<0.05), but silver glass ionomer cement retrofilling gruoups(group II and IV) showed significantly less apical leakage than no retrofilling group(control group) (P<0.01). 2. In the groups retrofilled with the same material, the apical leakage in cavities prepared with ultrasonic micro endo tip (group III and IV) was less than that in cavities prepared with mini contra-angle and bur(group I and II), but not significant statistically(P>0.05). 3. When apical cavities were prepared with same instrument. the egroups retrofilled with silver glass ionomer cement(group II and IV) showed significantly less apical leakage than the groups retrofilled with amalgam(group I and III)(<0.01).

  • PDF