• 제목/요약/키워드: section resistance factor

검색결과 66건 처리시간 0.026초

Review on the Fire Resistance and Pumpability Performance of Fiber Reinforced High Strength Concrete

  • Kwon, Hae-Won;Kim, Young-Su
    • 한국건축시공학회지
    • /
    • 제13권1호
    • /
    • pp.58-65
    • /
    • 2013
  • Currently, many high-rise buildings are built in Korea for land-efficient utilization and vista. In high-rise buildings this tall, the use of high-strength concrete is essential to reduce the cross-section of structure members and secure axial load. However, this high strength concrete is vulnerable to spalling by fire, due to the water vapor pressure caused by the very high temperature in fire. To prevent this, the main method used is to reinforce the concrete with fiber. However, there has been little research on the pumpability of fiber reinforced high strength concrete. For this reason, this study features a performance review based on the properties and pumpability of fiber reinforced high strength concrete. In addition, the parameter of rheology was measured by extracting mortar from the concrete, and friction factor was measured through a 400 m horizontal pipe pumping test using the fiber reinforced high strength concrete. The basic information on fiber reinforced high strength concrete that we obtain through the experiments and review will contribute to the field.

대구경 현장타설말뚝의 설계 사례 (Design of Large-scale Drilled Shaft)

  • 임철오;최영석;곽기석;장학성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.545-553
    • /
    • 2009
  • A lot of long-span marine bridge, which connects land to island or island to island, are being designed and constructed lately in south-west coast in South Korea. In the past, caisson foundations in marine were mainly adopted in construction and stability aspect, however, nowadays with development of pile construction technology, drilled shaft foundations are mainly adopted. As the long span cable stayed bridge and suspension bridge applied with lots of loads are being designed, the scale of pile foundations are getting larger. As the construction cost of substructure including foundation in marine bridges is too high, the appropriate evaluation of the axial bearing capacity of pile becomes a core factor to decide the construction cost of foundation if the drilled shaft is adopted as foundation type of bridge. The evaluation values of skin friction and end bearing capacity of drilled shaft in weathered rock suggested in south Korea are only to introduce the foreign specifications, and most of them are designed in a kind of hard soil layer. Also the allowable load of pile section is less than the expected bearing capacity of pile in the soil condition since the allowable capacity of pile is undervalued. Recently in order to improve this factor the bi-axial hydraulic load test of pile was taken, the data of load transfer analysis of pile, unit of skin friction and end bearing capacity are accumulated. In our country, the design of piles are made with ASD, however, LRFD considering service, strength and extreme state was adopted in Incheon Grand Bridge implemented with BTL, and the research to systematize the resistance coefficient appropriate at home country are being progressed.

  • PDF

LRFD에 의한 2경간 연속 강교량 주부재의 최적화 설계 (Optimal Design of I-type Girder in 2 Span Continuous Steel Bridges by LRFD)

  • 국중식;신영석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.78-85
    • /
    • 1999
  • In this study, I-type girders used as main members of a two span continuous steel bridge, are optimally designed by a Load and Resistance Factor Design method(LRFD) using an numerical optimization method. The width, height web thickness and flange thickness of the main girder are set as design variables, and light weight design is attempted by choosing the cross-sectional area as an object function. The main program is coded with C++ and connected with optimization modul ADS, which is coded with FORTRAN. The results of the program show that the stress constraints of noncomposite section during the initial construction stage become active in the positive moment area and the service limit state constaints become active in the negative moment area.

  • PDF

불평형 요소 변화에 따른 지중 송전선로의 시스순환전류 분석 (Analysis of Sheath Circulating Current in Underground Transmission Power Cables according to Unbalanced Factor)

  • 최수현;김규호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.294-295
    • /
    • 2015
  • Many unbalanced factors of underground transmission power cable, such as burying types and the length difference of the cable between each minor section, etc will cause the impedance unbalance and excessive circulating current between cables. So this paper presents the analysis of sheath circulating current in accordance with the distance between the center conductors and phase arrangement. ground resistance value changes on 154kV transmission system. Based on these simulation results, this paper will contribute to the reduction method of sheath circulation current.

  • PDF

모래지반에 대한 강널말뚝의 진통항타거동 연구 (A Study on Vibratory Behavior of Steel Sheet Pile Installed in Sand Ground)

  • 이승현;이종구;유완규;김병일
    • 한국지반공학회논문집
    • /
    • 제23권4호
    • /
    • pp.79-90
    • /
    • 2007
  • 모래지반에 대하여 계측기를 부착한 강널말뚝을 진동항타하고 항타과정을 통해서 계측된 자료를 분석하여 진동항타시 강널말뚝의 진동항타거동을 살펴보았다. 특히, 강널말뚝에 대한 진동항타시 말뚝에 작용하는 응력, 이론적인 항타력과 실제 말뚝에 전달되는 힘의 차이를 반영하는 효율계수, 강널말뚝의 강체거동 여부, 지반의 동적 저항특성, 강널말뚝의 관입특성 등을 분석하였다. 강널말뚝의 진동관입시 말뚝은 거의 강체로 거동하였으며 말뚝머리부에 작용하는 응력의 최대값은 재료의 인장강도보다 상당히 작았다. 진동관입중 실제 말뚝머리부에 전달되는 최대하중은 이론식에 의해 계산된 값의 72% 정도였다. 가속도-시간이력곡선으로부터 4개의 관입깊이에 대해 유도된 변위-시간이력곡선에서의 변위진폭값은 진동기 공운전시의 진폭값의 약 16$\sim$75% 정도인 것으로 나타났다.

Characteristics of Active Tuberculosis Patients Requiring Intensive Care Monitoring and Factors Affecting Mortality

  • Filiz, Kosar A.;Levent, Dalar;Emel, Eryuksel;Pelin, Uysal;Turkay, Akbas;Aybuke, Kekecoglu
    • Tuberculosis and Respiratory Diseases
    • /
    • 제79권3호
    • /
    • pp.158-164
    • /
    • 2016
  • Background: One to three percent of cases of acute tuberculosis (TB) require monitoring in the intensive care unit (ICU). The purpose of this study is to establish and determine the mortality rate and discuss the causes of high mortality in these cases, and to evaluate the clinical and laboratory findings of TB patients admitted to the pulmonary ICU. Methods: The data of patients admitted to the ICU of Yedikule Chest Diseases and Chest Surgery Education and Research Hospital due to active TB were retrospectively evaluated. Demographic characteristics, medical history, and clinical and laboratory findings were evaluated. Results: Thirty-five TB patients (27 males) with a median age of 47 years were included, of whom 20 died within 30 days (57%). The Acute Physiology and Chronic Health Evaluation II (APACHE II) and Sequential Organ Failure Assessment (SOFA) scores were significantly higher, and albumin and $PaO_2/FIO_2$ levels were significantly lower, and shock, multiple organ failure, the need for invasive mechanical ventilation and drug resistance were more common in the patients who died. The mortality risk was 7.58 times higher in the patients requiring invasive mechanical ventilation. The SOFA score alone was a significant risk factor affecting survival. Conclusion: The survival rate is low in cases of tuberculosis treated in an ICU. The predictors of mortality include the requirement of invasive mechanical ventilation and multiple organ failure. Another factor specific to TB patients is the presence of drug resistance, which should be taken seriously in countries where there is a high incidence of the disease. Finding new variables that can be established with new prospective studies may help to decrease the high mortality rate.

${\pi}$형 거더를 가진 4경간 사장교의 동적거동에 관한 실험적 연구 (An Experimental Study on the dynamic behavior of 4-Span Cable-Stayed Bridge with ${\pi}$-Type Girder)

  • 조재영;김영민;이학은;윤기용
    • 한국방재학회 논문집
    • /
    • 제4권1호
    • /
    • pp.15-24
    • /
    • 2004
  • 일반적으로, 2개의 I형 거더로 이루어진 ${\pi}$형거더는 공기역학적으로 불안하여 내풍설계에 있어 매우 불리 한 것으로 알려져 있다. 공기역학적 진동은 구조물의 강성이나 감쇠의 향상, 단면 형상의 연구 등에 의해 억제될 수 있으므로 본 연구에서는 ${\pi}$ 형단면을 가진 4경간 사장교에 대해 영각과 공기역학적 제진장치의 추가로 인한 단면의 변화에 따른 2차원 진동실험을 통하여 공기역학적 특성을 파악하도록 하였다. 등류와 난류에서의 실험결과 본 교량단면은 기본단면만으로도 내풍안정성을 충분히 갖추고 있기 때문에 페어링(Fairing) 및 베플(Baffle Plate) 등의 추가적인 공기역학적 제진장치가 필요하지 않을 것으로 판단된다. 이는 본 교량의 경우 주경간이 230m인 4경간으로 이루어져 있어 비슷한 단면을 가진 교량에 비하여 수직 및 비틀림 진동수가 크고 강성이 크기 때문에 설계풍속 내에서 공기역학적으로 안정한 것으로 보여진다.

정수식생이 존재하는 자연하도에서 1차원 수치모형 (1D Numerical Model for Rivers Flows with Emergent Vegetations on Floodplains and Banks)

  • 송주일;김종우;임창수;윤세의
    • 한국수자원학회논문집
    • /
    • 제44권1호
    • /
    • pp.9-22
    • /
    • 2011
  • 본 연구에서는 에너지 방정식에 기초하여 정수 식생이 존재하는 자연하도에 적용 가능한 1차원 수치모형을 제시하였다. 수위계산을 위한 마찰경사는 Darcy-Weisbach의 마찰식에 의해 계산되었다. 각 단면의 전체 Darcy-Weisbach 마찰계수는 하상조도높이, 식생, 식생구역과 비식생구역 사이의 전단저항, 그리고 홍수터와 주수로의 경계면 전단저항을 고려하여 산정하였다. 경계면 마찰계수는 Mertens방법과 Nuding방법에 의해 계산되었다. 제시된 모형을 가상하도에 적용하고 HEC-RAS모형 모의결과와 비교, 검증하였고, 식생밀도 등에 대하여 마찰계수의 민감도 분석을 실시하였다. 모형의 적용성검토를 위하여 독일 Enz강 일부구간을 대상으로 수치모의를 실시하고 실측수위와 비교하였다. 식생이 존재하는 Enz강의 실측수위와 계산수위를 비교한 결과 식생의 영향을 거의 받지 않고 주수로에 흐름이 형성되는 저유량의 경우와 식생의 영향을 지배적으로 받는 고유량 흐름 모두에서 합리적인 수위를 예측하여 제시된 모형의 적용 가능성을 확인하였다.

포장가속시험을 통한 개질아스팔트 혼합물의 소성변형 저항성 평가 연구 (Evaluation of Rutting Resistance of Modified Asphalt Concrete by Accelerated Pavement Testing)

  • 김준형;서영찬;권수안;조용주
    • 대한토목학회논문집
    • /
    • 제26권2D호
    • /
    • pp.285-292
    • /
    • 2006
  • 본 연구에서는 국내에서 개발된 Full-Scale 포장가속시험기(HAPT; Hanyang Accelerated Pavement Tester)를 소개하고, 이 시험의 시험운영과 함께 개질아스팔트 혼합물과 일반 밀입도 아스팔트 혼합물의 소성변형 저항성 비교 연구를 수행하였다. 포장가속시험은 일반 밀입도와 3종의 개질아스팔트 각각에 대해 3가지 온도조건(25-30, 40, $50^{\circ}C$)에서 소성변형 저항성을 평가하였으며, 이 평가 결과들은 DSR실험등 바인더의 실내실험 결과들과도 비교하였다. 포장가속시험을 통한 소성변형 발생량을 분석한 결과, 시험 대상이 된 모든 개질아스팔트 구간에서 일반 밀입도에 비해 소성변형 저항성이 큰 것으로 나타났다. 특히 고온조건에서는 그 차이가 매우 크게 나타났다. 일반 밀입도 아스팔트포장을 대상으로 포장온도 증가에 따른 소성변형 저항성을 분석한 결과 온도가 어느 이상 되면 소성변형 저항성이 급격히 떨어짐을 알 수 있었다. 또한 소성변형에 관련한 중요한 인자로 제시되는 $G^*/sin{\delta}$는 소성변형 저항성을 잘 나타내고 있는 것으로 나타났다. 반면에 회복탄성계수는 소성변형 저항성을 나타내는 인자로 바람직하지 않음도 확인하였다.

등가조고를 이용한 자갈하천의 하상저항 산정 (Estimation of Bed Resistance in Gravel-bed Rivers Using the Equivalent Roughness Height)

  • 김지성;김용전;이찬주;김원
    • 한국수자원학회논문집
    • /
    • 제42권8호
    • /
    • pp.619-629
    • /
    • 2009
  • 본 연구는 하상마찰의 척도인 등가조고를 이용하여 자갈하천의 하상저항을 산정하는 것이다. 이를 위하여 국내 8개 자갈하천에서 실측을 통하여 마찰계수 f를 산정하였고, 하상재료의 누가입경분포를 조사하였으며, 각 단면의 실측 마찰계수를 나타내기 위하여 대수 연직유속분포를 가정하여 계산된 평균 등가조고와 누가입경분포를 이용하여 계산된 구간 등가조고를 비교하였다. 더불어 등가조고를 사용하여 계산된 Manning 계수를 Strickler 유형의 기존 경험식에 의한 Manning 계수와 비교함으로써, 국내 자갈하천에서 기존 경험식을 이용한 하상저항 산정의 적용성을 검토하였다. 분석결과, 구간 등가조고가 대상구간의 하상특성을 대표할 수 있음을 확인하였고, 구간 등가조고로 계산된 Manning 계수가 실측 자료로부터 계산된 Manning 계수와 비교하여 RMS 오차가 0.003이하로 계산되어 실무 적용에 타당할 것으로 판된되었다. 또한 실제 하천에서 등가조고 $k_s$와 특정입경 $D_i$과의 비례계수 사이의 상관성이 적은 것으로 나타나, 하상 특정입경을 사용하여 Manning 계수를 산정하는 기존 경험식을 적용할 때 적절한 방정식의 선택에 어려움이 있을 것으로 판단된다.