• Title/Summary/Keyword: section of image analysis

Search Result 212, Processing Time 0.024 seconds

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

Social Network Analysis of author's interest area in Journals about Computer (컴퓨터 분야 논문지에서 저자의 관심분야에 대한 소셜 네트워크 분석)

  • Lee, Ju-Yeon;Park, Yoo-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.1
    • /
    • pp.193-199
    • /
    • 2016
  • Recently there are many researches about analyzing the interaction between entities by social network analysis in various fields. In this paper, we are going to analyze the author's interests area at the biography section in Journal of the Korea Institute of Information and Communication Engineering by social network analysis. The results show that many authors in that journal are mainly focusing on embedded, security, image processing, wireless network, big data, USN, network, RFID.

Analysis of Images According to the Fluid Velocity in Time-of-Flight Magnetic Resonance Angiography, and Contrast Enhancement Angiography

  • Kim, Eng-Chan;Heo, Yeong-Cheol;Cho, Jae-Hwan;Lee, Hyun-Jeong;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.185-191
    • /
    • 2014
  • In this study we evaluated that flow rate changes affect the (time of flight) TOF image and contrast-enhanced (CE) in a three-dimensional TOF angiography. We used a 3.0T MR System, a nonpulsatile flow rate model. Saline was used as a fluid injected at a flow rate of 11.4 cm/sec by auto injector. The fluid signal strength, phantom body signal strength and background signal strength were measured at 1, 5, 10, 15, 20 and 25-th cross-section in the experienced images and then they were used to determine signal-to-noise ratio and contrast-to-noise ratio. The inlet, middle and outlet length were measured using coronal images obtained through the maximum intensity projection method. As a result, the length of inner cavity was 2.66 mm with no difference among the inlet, middle and outlet length. We also could know that the magnification rate is 49-55.6% in inlet part, 49-59% in middle part and 49-59% in outlet part, and so the image is generally larger than in the actual measurement. Signal-to-noise ratio and contrast-to-noise ratio were negatively correlated with the fluid velocity and so we could see that signal-to-noise ratio and contrast-to-noise ratio are reduced by faster fluid velocity. Signal-to-noise ratio was 42.2-52.5 in 5-25th section and contrast-to-noise ratio was from 34.0-46.1 also not different, but there was a difference in the 1st section. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s. Consequently, 3D TOF MRA tests show that the faster fluid velocity decreases the signal-to-noise ratio and contrast-to-noise ratio, and basically it can be determined that 3D TOF MRA and 3D CE MRA are displayed larger than in the actual measurement.

Structural Character of Two-Dimensional Crystal of the S-Layer Glycoprotein from Methanoplanus limicola (Methanoplanus limicola S-Layer 당단백질 2차원 결정의 구조적 특성)

  • Cheong, Gang-Won;Kwack, Dae-Oh;Joo, Woo-Hong
    • Applied Microscopy
    • /
    • v.24 no.1
    • /
    • pp.102-113
    • /
    • 1994
  • A thin section of the methanogenic archaebacterium, Methanoplanus limicola, shows that the surface glycoprotein array (S-layer) is separated from plasma membrane by a distinct inter-space, approximately 4.0-6.0nm wide. We report our structural study of the S-layer by electron crystallographic techniques. Image analysis and thin sections of the S-layer treated with and without triton disclosed that retention of the single layer crystal requires the presence of detergent to avoid hydrophobic bonding.

  • PDF

Microstructure and Properties of Mortar Containing Synthetic Resin using Image Analysis (이미지 분석을 활용한 합성수지 혼입 모르타르의 특성 및 미세구조 분석)

  • Lee, Binna;Min, Jiyoung;Lee, Jong-Suk;Lee, Jang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.1
    • /
    • pp.59-65
    • /
    • 2016
  • Commercial synthetic resins with great amount of hydrogen atoms were investigated for neutron shielding aggregates. Total three types of resins were considered in this study: high density polyethylene (HDPE), polypropylene (PP), and ultra molecular weight polyethylene (UPE). When these resins replaced 20, 40, 60 vol% of fine aggregates, mechanical properties were first evaluated including compressive and tensile strengths, and then image/microstructure analyses such as cross-section analysis, SEM, and X-ray CT were performed. The results showed that the compressive and tensile strengths decreased with the increase of replacement ratio of HDPE and PP, which was found through image analysis that it was closely related to the distribution of resins at the failure surface of test specimens. The strength reduction of UPE was quite small compared to HDPE and PP but it abruptly increased when the replacement level exceeded 60 vol%. The results of microstructure analyses indicated that the replacement level significantly affected the amount of air void so that it is critical to determine the reasonable amount of UPE to make cementitous materials for neutron shielding.

Simultaneous Measurement of CH-OH PLIF and Stereoscopic PIV in Turbulent Premixed Flames (CH-OH PLIF와 Stereoscopic PIV계측법을 이용한 난류예혼합화염의 관찰)

  • Choi Gyung-Min;Tanahashi Mamoru;Miyauchi Toshio.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.102-103
    • /
    • 2004
  • Simultaneous CH and OH planar laser induced fluorescence(PLIF) and stereoscopic particle image velocimetry(PIV) measurements have been developed to investigate the local flame structure of turbulent premixed flames. The developed simultaneous two radical concentrations and three component velocity measurements on a two-dimensional plane was applied for relatively high Renolds number turbulent premixed flames in a swirl stabilized combustor. All measurements were conducted for methane-air premixed flames in the corrugated flamelets regime. Strong three-dimensional fluctuation implies that misunderstanding of the flame/turbulent interactions would be caused by the analysis of two-component velocity distribution in a cross section. Furthermore, comparisons of CH-OH PLIF and three-component velocity field show that the burned gases not always have high-speed velocity in relatively high Renolds number turbulent premixed flame.

  • PDF

An Analysis of Starting Motions in Time 300m Inline Skating (인라인 스케이트 T300m 출발동작 분석)

  • Park, Ki-Beom;Yang, Jeong-Ok;Lee, Joong-Sook
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.2
    • /
    • pp.123-137
    • /
    • 2003
  • This study is to present more effective starting skills through analysis of kinematic characteristics of starting motions in 300m Time Trials of Inline Skating. To achieve this goal, 6 athletes, 3 in the national team and 3 in business teams were chosen and their starting motions were examined with three-dimensional image analyses. The results of analyses in regard of positions and speed of the bodily center and angles, angular velocity, and linear velocity of articulations of lower limbs by sections of starting motions are as follows: In case of the central position, though it is effective to reduce the air resistance by lowering the upper part of the body maximumly, it is reasonable to accelerate by raising the upper part of the body to some degree for the running posture at the lower speed in the starting section. In the starting section, it is efficient to minimize the period of time in touching the ground. for this, it is necessary to train for taking motions without slippage while touching the ground. While 3 athletes in business teams kicked the ground as running right after the starting, the others in the national team slid on the ground. As the number of steps increased, the movable speed changed quickly. Thus the movable speed of athletes in the national team indicated big differences in two to three steps. If these factors are well supported, the push-away starting method might be better than the running starting method in terms of improvement of records.

Simultaneous Measurements of CH-OH PLIF and Stereoscopic PIV in Turbulent Premixed Flames (CH-OH PLIF와 Stereoscopic PIV동시계측에 의한 난류예혼합화염의 관찰)

  • Choi, Gyung-Min;Tanahashi, Mamoru;Miyauchi, Toshio
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.91-96
    • /
    • 2004
  • Simultaneous CH and OH planar laser induced fluorescence(PLIF) and stereoscopic particle image velocimetry (PIV) measurements have been developed to investigate the local flame structure of turbulent premixed flames. The developed simultaneous two radical concentrations and three component velocity measurements on a two-dimensional plane was applied for relatively high Reynolds number turbulent premixed flames in a swirl stabilized combustor. All measurements were conducted for methane-air premixed flames in the corrugated flamelets regime. Strong three-dimensional fluctuation implies that misunderstanding of the flame/turbulent interactions would be caused by the analysis of two-component velocity distribution in a cross section. Furthermore, comparisons of CH-OH PLIF and three-component velocity field show that the burned gases not always have high-speed velocity in relatively high Reynolds number turbulent premixed flame. The Reynolds number dependence of the flame front was clearly captured by the simultaneous CH-OH PLIF and stereoscopic PIV measurements.

  • PDF

Acoustic Target Strength Analysis for Underwater Vehicles Covering Near Field Spherical Wave Source Originated Multiple Bounce Effects (근접장 구면파 소스의 다중 반사 효과를 고려한 수중함의 음향표적강도 해석)

  • Cho, Byung-Gu;Hong, Suk-Yoon;Kwon, Hyun-Wung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.2
    • /
    • pp.196-209
    • /
    • 2010
  • For the analysis of Acoustic Target Strength(TS) that indicates the scattered acoustic intensity from the underwater vehicles, an analysis program that is applicable to scatterers insonified by spherical wave source in near field is developed. In this program, the Physical Optics(PO) method is embedded as a base component. To increase the accuracy of the program, multiple bounce effects based on Geometrical Optics(GO) method are applied. To implement multiple bounce effects, GO method is used together with PO method. In detail, GO method has a concern in the evaluation of the effective area, and PO method is involved in the calculation of Acoustic Target Strength for the final effective area that is evaluated by GO method. For the embodiment of near field spherical wave source originated multiple bounce effects, image source concept is implemented additively to the existing multiple bounce algorithm which assumes plane wave insonification. Various types of models are tested to evaluate the reliability of the developed program and finally, a submarine is analyzed as an arbitrary scatterer.

Face Image Analysis using Adaboost Learning and Non-Square Differential LBP (아다부스트 학습과 비정방형 Differential LBP를 이용한 얼굴영상 특징분석)

  • Lim, Kil-Taek;Won, Chulho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.6
    • /
    • pp.1014-1023
    • /
    • 2016
  • In this study, we presented a method for non-square Differential LBP operation that can well describe the micro pattern in the horizontal and vertical component. We proposed a way to represent a LBP operation with various direction components as well as the diagonal component. In order to verify the validity of the proposed operation, Differential LBP was investigated with respect to accuracy, sensitivity, and specificity for the classification of facial expression. In accuracy comparison proposed LBP operation obtains better results than Square LBP and LBP-CS operations. Also, Proposed Differential LBP gets better results than previous two methods in the sensitivity and specificity indicators 'Neutral', 'Happiness', 'Surprise', and 'Anger' and excellence Differential LBP was confirmed.