• Title/Summary/Keyword: section loss

Search Result 562, Processing Time 0.033 seconds

Experimental Study on the Behavior of Psudo Circular Concrete Column (원형기둥 콘크리트 구멍손실 단면적의 압축거동에 관한 축소모델 실험적 연구)

  • 손기상
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.3
    • /
    • pp.89-98
    • /
    • 2001
  • There have been a lot of studies about repair & strengthening of the concrete structure. But there has almost not been my study on section damage effect due to holes drilled out for installing additional facilities or equipment, such as rack on the wall of building or underground culvert system, plumbing system through the column or wall of it, after being occupied. This study is to find out how much the section loss due to holes will give loss of section strength. We cm determine if we repair or reinforce it completely or not, using strength loss from the hole. Hole size of diameter 3cm, 2cm, lcm, depth of 3cm, 5cm, 10cm, and position of each hole has been considered as variables of this study. It is concluded that section loss 30% results in 53% of strength damage.

  • PDF

Design of optical power splitters and couplers composed of deeply etched multimode interference section (깊이 식각된 다중모드 간섭 영역으로 구성된 광전력 분배기 및 결합기의 설계)

  • 김정욱;정영철
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.4
    • /
    • pp.62-72
    • /
    • 1997
  • The optical power splitter/couplers based on MMI(multimode interference) in GaAs/AlGaAs are studied. We presetn a design of optical power splitter/couplers, which have deeply etched multimode waveguide. The properties and fabrication tolerance on the etching depth, multimode waveguide width are simulatedusing a FD-BPM (finite difference beam propgation method). Proposed 1*N optical of designed device is 0.7dB smaller than the optical power splitter with a shallowly etched MMI section. For 0.5dB excess loss, the predicted fabrication tolerance is 0.6.mu.m on the multimode waveguide width of the 14 optical power splitter with a deeply etched MMI section. Also excess loss and uniformity of poposed 32*32 optical power coupler are below 0.3dB. The excess loss of proposed 32*32 optical power coupler is 2dB smaller than the optical power coupler with a shallowly etched MMI section. It is shown that the optical power splitters/couplers with a deeply etched mMI section have low loss, good uniformity, and improved fabriction tolerance.

  • PDF

Effect of Air Gap Thickness on Top Heat Loss of a Closed-loop Oscillating Heat Pipe Solar Collector

  • Nguyen, Kim-Bao;Choi, Soon-Ho;Yoon, Doo-Ho;Choi, Jae-Hyuk;Oh, Cheol;Yoon, Seok-Hun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.7
    • /
    • pp.994-1002
    • /
    • 2009
  • In this paper, effect of air gap thickness between absorber plate and glass cover on top heat loss of a closed loop oscillating heat pipe (CLOHP) solar collector was investigated. The CLOHP, which is made of copper with outer diameter of 3.2mm and inner diameter of 2.0mm, comprises 8 turns with heating, adiabatic and cooling section. The heating section of the heat pipe was attached to absorber plate which heated by solar simulator simulated by halogen lamps. The cooling section of the heat pipe was inserted into collector's cooling section that made of transparent acrylic. Temperatures of absorber plate, glass cover, and ambient air measured by K-type thermocouple and were recorded by MV2000-Yokogawa recorder. Top heat loss coefficients and top heat loss of the collector corresponding to some cases of air gap thickness were determined. The result of experiment shows the optimal air gap thickness for minimum top heat loss of this solar collector.

Transmission Loss Prediction of KHST's Wall Section (KHST 차량 벽면의 투과손실값 예측)

  • Kim, Kwan-Ju;Yoon, Tae-Jung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.104-109
    • /
    • 2002
  • The purpose of this study is to calculate transmission loss of KHST passenger vehicle's wall section accurately Typical transmission loss measurement of wall in the laboratory condition was carried out in advance, which is easier than KHST. Transmission loss results were compared with those by statistical acoustic method. Transmission loss values of KHST calculated by experimental method are compared with those from closed form solution.

  • PDF

A Study on the Design of Free-Fall Simulator using concept of Vertical Wind Tunnel (수직형 풍동을 응용한 고공강하 시뮬레이터의 설계에 대한 연구)

  • Choi, Sang-Gil;Cho, Jin-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.447-452
    • /
    • 2000
  • In this study, the design of Free-Fall Simulator was carried out using concept of vertical wind tunnel. Free-Fall Simulator is not an experimental equipment but a training equipment. Therefore Free-Fall Simulator needs a large training section compared with test section of wind tunnel and has critical limit of height. These limits bring about the difficulty of design for a return passage. Due to small area ratio, the downstream flow of training section with high speed is not decelerated adequately to the fan section. High-speed flow leads to great losses in the small area ratio diffuser and corner. So design of diffusers and corners located between training section and fan section has a great effect on the Free-Fall Simulator performance. This study used an estimation method of subsonic wind tunnel performance. It considered each section of Free-Fall Simulator as an independent section. Therefore loss of one section didn't affect loss of other sections. Because losses of corner with vane and $1^{st}$ diffuser are most parts of overall Free-Fall Simulator, this study focused on the design of these sections.

  • PDF

Early radiographic diagnosis of peri-implantitis enhances the outcome of peri-implantitis treatment: a 5-year retrospective study after non-surgical treatment

  • Chang, Hee-Yung;Park, Shin-Young;Kim, Jin-Ah;Kim, Young-Kyun;Lee, Hyo-Jung
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.3
    • /
    • pp.82-93
    • /
    • 2015
  • Purpose: This retrospective study evaluated the relationship between the timing of peri-implantitis diagnosis and marginal bone level after a 5-year follow-up of non-surgical peri-implantitis treatment. Methods: Thirty-three patients (69 implants) were given peri-implantitis diagnosis in 2008-2009 in Seoul National University Bundang Hospital. Among them, 31 implants from 16 patients were included in this study. They were treated non-surgically in this hospital, and came for regular maintenance visits for at least 5 years after peri-implantitis treatment. Radiographic marginal bone levels at each interval were measured and statistical analysis was performed. Results: Timing of peri-implantitis was one of the significant factors affecting initial bone loss and total bone loss not additional bone after peri-implantitis diagnosis. Patients with cardiovascular disease and diabetic mellitus were positively influenced on both initial bone loss and total bone loss. Patients who needed periodontal treatment after implant placement showed a negative effect on bone loss compared to those who needed periodontal treatment before implant placement during entire periods. Implant location also significantly influenced on amounts of bone loss. Mandibular implants showed less bone loss than maxillary implants. Among surgical factors, combined use of autogenous and xenogenic bone graft materials showed a negative effect on bone loss compared to autogenous bone graft materials. Use of membrane negatively affected on initial bone loss but positively on additional bone loss and total bone loss. Thread exposure showed positive effects on initial bone loss and total bone loss. Conclusions: Early peri-implantitis diagnosis led to early non-surgical intervention for peri-implantitis treatment, which resulted in the maintenance of the bone level as well as preservation of the implant.

Research on the Transmission Loss Analysis of the Honeycomb Structure's Floor Section (허니콤 구조물을 갖는 차체 바닥의 투과손실 해석기법 연구)

  • Kim, Kwan-Ju;Kim, Sang-Su;Park, Jin-Kyu
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • Sound transmission characteristics are investigated on the test specimen for the railway vehicle's floor section. Transmission loss on the honeycomb structure has been examined experimentally with the reverberation chamber. Predicted transmission loss values using NASTRAN, AUTOSEA2, are compared with measured Haloes and the effect of resonance on the transmission loss is identified. Transmission loss of different shapes of honeycomb structure are predicted.

A New Broadband Microstrip-to-SIW Transition Using Parallel HMSIW

  • Cho, Dae-Keun;Lee, Hai-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.2
    • /
    • pp.171-175
    • /
    • 2012
  • In this work, a new microstrip-to-substrate integrated waveguide (SIW) transition using the parallel half-mode substrate integrated waveguide (HMSIW) is proposed. The proposed transition consists of three sections : a microstrip, parallel HMSIWs, and an SIW. By inserting the parallel HMSIWs section between the microstrip section and the SIW section, the proposed transition can improve the return loss characteristics of the near cut-off frequency because the HMSIWs section has a lower cut-off frequency than the SIW section (8.6 GHz). The lower cut-off frequency is achieved through gradual electromagnetic field mode changes for a low reflection. The measured return loss is less than 20 dB in the of 9.1~16.28 GHz freqeuncy range for the back-to-back transition. The measured insertion loss is within 1.6 dB for the back-to-back transition. The proposed transition is expected to play an important role in wideband SIW circuits fed by a microstrip.

A retrospective clinical study of single short implants (less than 8 mm) in posterior edentulous areas

  • Kim, Sang-Yun;Ku, Jeong-Kui;Kim, Hyun-Suk;Yun, Pil-Young;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.191-196
    • /
    • 2018
  • PURPOSE. The goal of this study was to evaluate the clinical outcome of single short implants, less than 8 mm in length, placed in the posterior area. MATERIALS AND METHODS. A total of 128 patients (75 male and 53 female, mean age: $52.6{\pm}11.2years$) with 154 implants participated. Implant marginal bone loss, and survival and success rates were measured. RESULTS. The mean follow-up period was $51.35{\pm}24.97months$. A total of 128 implants, 8 mm in length, were placed in patients who had mean marginal bone loss of 0.75 mm. These implants had a survival rate of 95.3%. Twenty-six implants, 7 mm in length, were placed in areas with a mean marginal bone loss of 0.78 mm and had a survival rate of 96.2%. Both marginal bone loss and survival rate were not statistically different among the groups. In the maxilla, 34 implants showed a mean marginal bone loss of 0.77 mm and a survival rate of 97.1%. In the mandible, 120 implants showed a mean marginal bone loss of 0.75 mm and a survival rate of 95.0%. The average marginal bone loss around all implants was $0.76{\pm}0.27mm$ at the last follow-up review after functional loading. The survival rate was 95.6% and success rate was 93.5%. CONCLUSION. In our study, single short implants less than 8 mm in length in the posterior areas had favorable clinical outcomes.

Analysis of factors affecting crestal bone loss around the implants

  • Park, Ji-Hoon;Kim, Young-Kyun;Yun, Pil-Young;Yi, Yang-Jin;Yeo, In-Sung;Lee, Hyo-Jung;Park, Jin-Young
    • Journal of Korean Dental Science
    • /
    • v.2 no.2
    • /
    • pp.12-17
    • /
    • 2009
  • Purpose : To determine whether peri-implant crestal bone loss could be affected by systemic disease, primary ISQ value, implantation method (submerged vs. non-submerged), surface treatment, and bone density Materials and methods : Patients who underwent fixture installation from June 24, 2005 to October 23, 2008 at Seoul National University Bundang Hospital were evaluated. A total of 157 patients (male: 52, female: 85) had 346 fixtures installed. Among them, 49 patients had periapical radiographs taken 1 year after prostheses were first set. A total of 97 fixtures were implanted. In particular, 30 fixtures were installed in patients with systemic diseases such as diabetes mellitus, cardiovascular disease, hypertension, and liver disease. The immediate stability of implants was measured with $Osstell^{tm}$. Implant surface treatment was classified into two groups (RBM, Cellnest (Anodized)), and bone density, into four groups (D1~D4). The bone resorption on the mesial and distal areas of fixtures was measured with periapical radiographs using the paralleling technique, and the mean value was calculated. The length determination program in IMPAX (AGFA, Belgium) was used. Results : At least 332 out of 346 (96%) installed GS II implants were successfully osseointegrated 1 year after prostheses were first set. The mean value of the bone resorption of the installed GS II implants was 0.44mm. The minimum value was 0mm, and the maximum value, 2.85mm. There was a statistically significant difference between the implantation methods (submerged, non-submerged) with regard to the amount of alveolar bone loss 1 year after prostheses were first set (p<0.05). Non-submerged implants showed less crestal bone loss. Note, however, that other variables had no correlation with crestal bone loss (p>0.05). Conclusion : There was a statistically significant difference between the 1-stage method and 2-stage method with regard to the amount of alveolar bone loss 1 year after prostheses were first set. Systemic disease, primary ISQ value, surface treatment, and bone density were not associated with alveolar bone loss. Other variables were assumed to have a correlation with alveolar bone loss.

  • PDF