DOI QR코드

DOI QR Code

Effect of Air Gap Thickness on Top Heat Loss of a Closed-loop Oscillating Heat Pipe Solar Collector

  • Nguyen, Kim-Bao (Graduate School of Marine System Engineering, Korea Maritime University) ;
  • Choi, Soon-Ho (R&D Center of DHP Company) ;
  • Yoon, Doo-Ho (Busan Campus of Korea Polytechnic. VII) ;
  • Choi, Jae-Hyuk (Division of Marine System Engineering, Korea Maritime University) ;
  • Oh, Cheol (Division of Marine System Engineering, Korea Maritime University) ;
  • Yoon, Seok-Hun (Division of Marine System Engineering, Korea Maritime University)
  • Published : 2009.11.30

Abstract

In this paper, effect of air gap thickness between absorber plate and glass cover on top heat loss of a closed loop oscillating heat pipe (CLOHP) solar collector was investigated. The CLOHP, which is made of copper with outer diameter of 3.2mm and inner diameter of 2.0mm, comprises 8 turns with heating, adiabatic and cooling section. The heating section of the heat pipe was attached to absorber plate which heated by solar simulator simulated by halogen lamps. The cooling section of the heat pipe was inserted into collector's cooling section that made of transparent acrylic. Temperatures of absorber plate, glass cover, and ambient air measured by K-type thermocouple and were recorded by MV2000-Yokogawa recorder. Top heat loss coefficients and top heat loss of the collector corresponding to some cases of air gap thickness were determined. The result of experiment shows the optimal air gap thickness for minimum top heat loss of this solar collector.

Keywords

References

  1. S. Rittidech et al, "Experiment study of the performance of a solar collector by oscillating heat pipe", Applied Thermal Engineering 27, pp. 1978-1985, 2007 https://doi.org/10.1016/j.applthermaleng.2006.12.005
  2. Piyanun Charaensawan et al, "Thermal performance of horizontal closed loop oscillating heat pipes", Applied Thermal Engineering 28, pp. 460-466, 2008 https://doi.org/10.1016/j.applthermaleng.2007.05.007
  3. S. Rittidech et al, "Correlation to predict heat transfer characteristics of a oscillating heat pipe at normal operating condition", Applied Thermal Engineering 23, pp. 495-510, 2003 https://doi.org/10.1016/S1359-4311(02)00215-6
  4. R. R. Avezov et al, "Thermal optimization of closed air layer of a light-absorbing heat exchange panel-transparent cover system of water-heating flat-plate solar collectors", Applied Solar Energy, vol. 43, No. 4, pp. 207-210, 2007 https://doi.org/10.3103/s11949-007-4003-y
  5. M. Mahasudan et al, "Optimization of heat losses in normal and reverse flat-plate collector configurations: Analysis and performance", Energy Con.& Mgmt vol. 21, pp. 191-198, 1981 https://doi.org/10.1016/0196-8904(81)90014-5
  6. Seok-Hun Yoon et al, "A study on the Heat transfer characteristics of self-oscillating heat pipe", KSME international Journal, Vol. no. 3, pp. 354-362, 2002
  7. G.N. Tiwari, "Solar energy fundamental, design, modeling and application", Center for Energy Study, Indian Institute of Technology, Delhi, New Delhi-110 016, India, 2002