• 제목/요약/키워드: section capacity

검색결과 1,067건 처리시간 0.027초

Flexural behaviour of square UHPC-filled hollow steel section beams

  • Guler, Soner;Copur, Alperen;Aydogan, Metin
    • Structural Engineering and Mechanics
    • /
    • 제43권2호
    • /
    • pp.225-237
    • /
    • 2012
  • This paper presents an experimental investigation of the flexural behavior of square hollow steel section (HSS) beams subjected to pure bending. Totally six unfilled and nine ultra high performance concrete (UHPC)-filled HSS beams were tested under four-point bending until failure. The effects of the steel tube thickness, the yield strength of the steel tube and the strength of concrete on moment capacity, curvature, and ductility of UHPC-filled HSS beams were examined. The performance indices named relative ductility index (RDI) and strength increasing factor (SIF) were investigated with regard to different height-to-thickness ratio of the specimens. The flexural strengths obtained from the tests were compared with the values predicted by Eurocode 4, AISC-LRFD and CIDECT design codes. The results showed that the increase in the moment capacity and the corresponding curvature is much greater for thinner HSS beams than thicker ones. Eurocode 4 and AISC-LRFD predict the ultimate moment capacity of the all UHPC-filled HSS beams conservatively.

하이브리드 보의 휨성능에 관한 연구 (An Study on the flexural capacity of 'Hybrid Beam')

  • 홍성걸;양동현;정종현;임병호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.301-304
    • /
    • 2006
  • This study was performed to suggest a theoretical method of flexural capacity of 'Hybrid Beam'. Since the center of 'Hybrid Beam' is composed of embedded composite beam section, a theoretical method of embedded composite beam could be applied to estimation of flexural capacity of 'Hybrid Beam'. In this study, a theoretical evaluation method for flexural capacity of embedded composite beam, which is suggested by KBC 2005, is chosen and its applicability is evaluates as comparing theoretical results with experimental results. In results, for estimation of theoretical ultimate strength, it is proper method that both effects due to concrete and rebar are considered and whole section is assumed to be plastic. and for estimation of theoretical strength at yielding stste, it is proper to apply allowable stress design.

  • PDF

A NOTE ON MODULUS METHOD AND CAPACITY

  • CHUNG Bo-HYUN
    • Journal of applied mathematics & informatics
    • /
    • 제20권1_2호
    • /
    • pp.647-655
    • /
    • 2006
  • We consider the applications of modulus to the boundary behavior of meromorphic functions in connection with the singularities. The proofs are based on the method of modulus. The relations between the moduli and the logarithmic capacities shall be introduced and we have shown that the conformal capacity is related to the modulus.

Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (II): Theoretical study

  • Li, Guo-Qiang;Gu, Fulin;Jiang, Jian;Sun, Feifei
    • Steel and Composite Structures
    • /
    • 제23권4호
    • /
    • pp.409-420
    • /
    • 2017
  • This paper theoretically studies the cyclic behavior of hybrid connections between steel coupling beams and concrete shear walls with embedded steel columns. Finite element models of connections with long and short embedded steel columns are built in ABAQUS and validated against the test results in the companion paper. Parametric studies are carried out using the validated FE model to determine the key influencing factors on the load-bearing capacity of connections. A close-form solution of the load-bearing capacity of connections is proposed by considering the contributions from the compressive strength of concrete at the interface between the embedded beam and concrete, shear yielding of column web in the tensile region, and shear capacity of column web and concrete in joint zone. The results show that the bond slip between embedded steel members and concrete should be considered which can be simulated by defining contact boundary conditions. It is found that the loadbearing capacity of connections strongly depends on the section height, flange width and web thickness of the embedded column. The accuracy of the proposed calculation method is validated against test results and also verified against FE results (with differences within 10%). It is recommended that embedded steel columns should be placed along the entire height of shear walls to facilitate construction and enhance the ductility. The thickness and section height of embedded columns should be increased to enhance the load-bearing capacity of connections. The stirrups in the joint zone should be strengthened and embedded columns with very small section height should be avoided.

DSP를 이용한 자동고장구분개폐기의 제어장치 개발 (The Development of ASS Controller Using DSP)

  • 우천희;한태환
    • 전기학회논문지P
    • /
    • 제53권3호
    • /
    • pp.142-147
    • /
    • 2004
  • In this study, We developed the microprocessor based controller for Auto Section Switch(ASS). This is installed at consumer's medium-high voltage(load capacity is below 4,000 kVA) switchgear. This function is cooperate with protection device of fault section and automatically dividing the section. And It is designed by Air putter type extinction structure and adopt the mechanism and breaking part module of existing Load Breaker Switch. In addition, We successfully conducted the operation test and checked main function of proto-type.

중력하중을 받는 SRC기둥-합성보 접합부 실험 (Test of SRC Column-to-Composite Beam Connection under Gravity Loading)

  • 김영주;배재훈;안태상;장성훈
    • 한국강구조학회 논문집
    • /
    • 제26권5호
    • /
    • pp.441-452
    • /
    • 2014
  • 본 논문에서는 중력하중을 받는 SRC기둥과 합성보 접합부의 정적실험을 수행하였다. 합성보는 H형단면과 U형단면으로 구성되어 있다. 모두 5개의 실대형 실험체를 설계하여 실험변수, 즉, H형단면 크기, 스터드커넥터의 유무, 스티프너와 상부근의 유무 등이 접합부의 거동에 미치는 영향을 조사하였다. 또한 H형단면과 U형단면의 용접접합부의 구조성능을 초기강성, 내력 및 변형능력을 중심으로 기술하였다.

기존 채널형 복공판과 새로운 복공판 모델에 관한 비교분석 연구 (A Comparative Analysis of Existing Channel-Type Lining Board and New-Type lining Board Models)

  • 김두환;김영세
    • 한국안전학회지
    • /
    • 제19권3호
    • /
    • pp.78-83
    • /
    • 2004
  • The channel-type lining board that partial welded on many partition frames is used to normal servicing lining board type. On this study is to investigate existing channel-type lining board's capacity by using the static loading test. From this study, to develop new-type lining board which reflect well cross section area and sectional modulus of existing channel-type lining board. Six types FEM model are adopted. The accumulated test results of stress conditions and deflections by section shapes will be used to analyzed the relation between the capacity and the section shape. With the comparing the results of static loading test and FEM analysis.

Mechanical behaviour of concrete filled double skin steel tubular stub columns confined by FRP under axial compression

  • Wang, Jun;Liu, Weiqing;Zhou, Ding;Zhu, Lu;Fang, Hai
    • Steel and Composite Structures
    • /
    • 제17권4호
    • /
    • pp.431-452
    • /
    • 2014
  • The present study focuses on the mechanical behaviour of concrete filled double skin steel tubular (CFDST) stub columns confined by fiber reinforced polymer (FRP). A series of axial compression tests have been conducted on two CFDST stub columns, eight CFDST stub columns confined by FRP and a concrete-filled steel tubular (CFST) stub column confined by FRP, respectively. The influences of hollow section ratio, FRP wall thickness and fibre longitudinal-circumferential proportion on the load-strain curve and the concrete stress-strain curve for stub columns with annular section were discussed. The test results displayed that the FRP jacket can obviously enhance the carrying capacity of stub columns. Based on the test results, a new model which includes the effects of confinement factor, hollow section ratio and lateral confining pressure of the outer steel tube was proposed to calculate the compressive strength of confined concrete. Using the present concrete strength model, the formula to predict the carrying capacity of CFDST stub columns confined by FRP was derived. The theoretically predicted results agree well with those obtained from the experiments and FE analysis. The present method is also adapted to calculate the carrying capacity of CFST stub columns confined by FRP.

Experimental study of the behavior of composite timber columns confined with hollow rectangular steel sections under compression

  • Razavian, Leila;Naghipour, Morteza;Shariati, Mahdi;Safa, Maryam
    • Structural Engineering and Mechanics
    • /
    • 제74권1호
    • /
    • pp.145-156
    • /
    • 2020
  • There are separate merits and demerits to wood and steel. The combination of wood and steel as a compound section is able to improve the properties of both and ultimately increase their final bearing capacity. The composite cross-section made of steel and wood has higher hardness while showing more ductility and the local buckling of steel is delayed or completely prevented. The purpose of this study is to investigate the behavior of composite columns enclosed in wooden logs and the hollow sections of steel that will be examined in a laboratory environment under the axial load to determine the final bearing capacity and sample deformation. In terms of methodology, steel sheet and carbon fiber reinforced polymer sheet (FRP) are tested to construct hollow rectangular sections and reinforce timber. Besides, the method of connecting hollow sections and timber including glue and screw has been also investigated. As a result, timber lumber enclosed with carbon fiber-reinforced polymer sheets in which fibers are horizontally located at 90° are more resistant with better ductility.

SHN 형강 보-기둥 접합부의 내진성능 평가 (Seismic Performance Evaluation of Welded Beam-Column Connections abricated with SHN Steel Sections)

  • 김태진;박종원;조정혁;김희동
    • 한국강구조학회 논문집
    • /
    • 제20권6호
    • /
    • pp.829-838
    • /
    • 2008
  • 국내 현실에 적합한 내진 접합부 상세 개발과 평가를 위하여 국내 중저층 철골건물에 적용되는 단면을 갖는 보와 기둥으로 구성 된 접합부 실험체를 선정하여 반복재하 실험을 수행하였다. 실험변수는 접합부 형식과 강종이며 새로 개발된 내진용 형강(SHN490)과 기존 형강 (SM490)의 성능 차이를 비교하였다. 소재인장시험결과에 의하면 SHN490 형강의 항복강도와 인장강도의 분포는 SM490형강의 분포보다 균일한 것으로 평가되었다. 접합부 실험체의 용접부에서의 취성파괴는 관찰되지 않았고 소정의 소성변형 능력을 발휘한 후 보 플랜지의 열영향부나 용 접접근공의 응력집중부위에서 파단이 발생하였다. 동일한 강종으로 구성된 실험체의 경우, 보의 웨브가 볼트에 의하여 기둥에 연결된 접합부 (WUF-B)보다는 용접에 의하여 연결된 접합부(WUF-W)의 회전과 에너지 소산능력이 더 컸다. 또한 동일한 접합부 형식의 실험체에서는 SM490 형강으로 구성된 실험체보다는 SHN490 실험체의 회전과 에너지 소산능력이 더 컸다.